• 제목/요약/키워드: Medical recording

검색결과 311건 처리시간 0.022초

반도체 미세전극을 이용한 말초 신경에서의 신경 신호 기록 (Neural Recordings Obtained from Peripheral Nerves Using Semiconductor Microelectrode)

  • 황은정;김성준;조하원;호우택
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.31-34
    • /
    • 1997
  • A semiconductor microelectrode array has been successfully used in obtaining single unit recordings from medial giant nerve of clay fish, rat saphenous nerve and abdominal ganglia of aplysia. The recording device fabricated using silicon microfabrication techniques is a depth-probe type and, previously, has been mostly used to record from central nerve system of vertebrates. From invertebrates, and also from peripheral nerves of vertebrates, however, the quality of the recorded signal depends heavily on the recording conditions, such as the proximity of the electrode site to the nerve cells and the size of the neuron. We have modeled the signal to noise ratio as unctions of these parameters and compared the experimental data with the calculated values thus obtained.

  • PDF

휴대용 호흡 감시장치의 개발 (Development of Handheld Respiration Monitoring System)

  • 권성훈;김희찬;최성욱
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.183-184
    • /
    • 1998
  • Respiration monitoring is important in many clinical situations due to its relationship to vitality. But present commercial monitoring systems are bulky and expensive, so they are inadequate to be used for long term recording or out-patients application. We have developed a low cost, low power, handhold respiration monitoring system based on airflow measurement. Respiration flow is indirectly detected using a thermister or a themocouple sensor. Real time recording of respiration rate, abnormality detection and apnea alarming are available.

  • PDF

디지털 휴대용 생체 기록계 개발에 관한 연구 (A Study on Developement of Portable Digital Bio-signal Recorder)

  • 이호재;전태의;윤충화;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.109-113
    • /
    • 1993
  • In this paper, we devised a simple portable digital recorder for a day life ECG signal recording. The system are consisted of ECG amp. part, signal conditioning part. A/D converter, data compression part and digital memory part. An ADPCM algorithm used at data compress part for 50% of data reduction. The maximum lengths of recording times take 3 hours in 1 mega byte memory.

  • PDF

신경신호기록용 능동형 반도체미세전극을 위한 CMOS 전치증폭기의 잡음특성 설계방법 (Noise Performance Design of CMOS Preamplifier for the Active Semiconductor Neural Probe)

  • 김경환;김성준
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권5호
    • /
    • pp.477-485
    • /
    • 2000
  • 본 논문에서는 신경신호기록을 위한 반도체 미세전극용 전치증폭기의 잡음특성을 설계하기 위한 체계적인 방법을 제시한다. 세포외기록(extracellular recording)에 의하여 측정된 신경신호와 전형적인 CMOS소자의 저주파 잡음특성을 함계 고려하여 전체 신호대잡음비를 계산하였다. 2단 CMOS 차동증폭기에 대한 해석과 함께 신호대잡음비에 중요한 영향을 끼치는 요소들에 대하여 설명하였다. 출력잡음전력에 대한 해석적인식을 유도하였으며 이로부터 회로설계자가 조절할 수 있는 주파수응답과 소자 파라미터들을 결정하였다. 입력소자의 크기와 트랜스컨덕턴스의 비가 최적영역으로부터 약간 벗어날 경우에 신호대잡음비가 크게 저하됨을 보였다. 이와 함께 만족스런 잡음특성을 위한 증폭이의 설계 변수 값들도 제시하였다.

  • PDF

각기 다른 유문-십이지장의 기질적 병변 3증례에 대한 장음 측정 보고 : 장음의 주주파수를 중심으로 (Bowel Sound Recording for Structural Deformity in the Pylorus-Duodenum: Report of 3 Cases)

  • 윤상협
    • 대한한방내과학회지
    • /
    • 제36권3호
    • /
    • pp.276-283
    • /
    • 2015
  • Objectives: The purpose of this study is to report bowel sound patterns recorded in 3 diseases associated with structural deformity of the pylorus-duodenum. Methods: : Bowel sound recording is a useful non-invasive tool for the evaluation of gastrointestinal motility. However, the difficulty in manual attachment of the electronic stethoscope on the abdominal wall and noise production against bowel sound signals have prohibited its widespread use. Therefore, I developed a new apparatus that eliminates the noise; it contains a sound absorbing device and a holder for the head of stethoscope. Using the new bowel sound recording system, bowel sounds of the patients were recorded repeatedly. The endoscopic and abdominal computed tomography findings were obtained from other hospitals' medical record, and all patients were confirmed to have structural deformity in the pylorus-duodenum. The records of each patient were compared and assessed. Results: : Patients had either duodenal ulcer scar, pyloric stricture, or far advanced malignant stomach cancer, as diagnosed by the gastroscopy. Their dominant frequency of bowel sound obtained from the new system was checked more than 2 times at regular intervals. All 8 recordings in the 2 patients with duodenal ulcer scar (5 times) or pyloric stricture (3 times) showed a decrease in postprandial than fasting dominant frequency. One patient with stomach cancer showed no significant change between postprandial and fasting states at 2 recordings. Conclusions: The analysis of dominant frequency in bowel sounds can indicate the existence of pyloric obstruction that could delay gastric emptying.

한방 병원 간호 업무에 대한 환자, 간호사 및 한의사의 인식 비교 연구 (Perceptions of Patients, Nurses and Oriental Medical Doctors About Nursing Activities in Oriental Medical Hospitals)

  • 이애란;양경희;한선희;장혜숙
    • 대한간호학회지
    • /
    • 제23권2호
    • /
    • pp.284-298
    • /
    • 1993
  • This study was carried out to compare perceptions about nursing activities in oriental medical hospital settings. Data were collected from 47 patients hospitalized in an oriental medical hospital, and 41 nurses and 47 oriental medical doctors working in four oriental medical hospitals from July 10th to Sept.20th, 1991. The findings of this study are as follows. 1. There were significant differences in the perceptions about physical nursing activities between patients ( M=44.07) and nurses (M=48.44) (t=-3.09. p=0.003) , and between nurses and oriental medical doctors (M=41.47) (t=-5,20. p=0.000). 2. There were no differences in perceptions about psychological and emotional nursing activities between patients ( M=27.64) and nurses (M=28.52) (t=-1.02, p=0.310), but there were differences between nurses and oriental medical doctors ( M=24. 31) (t=-5.31, p=0.000). 3. There were differences in perceptions about observation, recording and implemention of medical care activities between patients (M=53.65) and nurses (M=57.08) (t=-2.15, p=0.034), but there were no differences between nurses and oriental medical doctors (M=57.28) (t=0.14, p=0.892). 4. There were no differences in perceptions about nursing management activities between patients (M=24.88) and nurses (M=26.42) (t=-1.91, p=0.059), but there were differences between nurses and oriental medical doctors (M=24.25) (t=-3.24, p=0.002).

  • PDF

Telemetry를 통합한 재택 진료시스템의 개발 (Development of Home-care Medical Information System integrating Telemetry)

  • 함지훈;지영준;임상현;박광석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.295-298
    • /
    • 1997
  • We developed the system that enables patients to be treated at home during their daily life through digital telemetry and public communication line. This system records and transfers ECG signals through wireless digital telemetry unhindering the patient's normal activities in long-term recording, and transmits the processed data, which enables real-time remote examination via ISDN phone line. Patient's image, voice, and transmitted signals are transferred to medical experts in remote medical center interactively.

  • PDF

진사탁(陳士鐸)의 심포론(心包論) 연구(硏究) - "외경미언(外經微言)"을 중심으로 - (A Study on Jinsatak(陳士鐸)'s theory of Simpo(心包))

  • 김정철;조은희;금경수
    • 대한한의학원전학회지
    • /
    • 제23권2호
    • /
    • pp.141-155
    • /
    • 2010
  • Simpo(心包. Pericardium) was described early in "Hwangjenaegyeong(黃帝內經)". But there has been a lot of criticisms about this organ. Jinsatak(陳士鐸) is one of famous doctors in Cheong(淸) dynasty. He suggested a creative Oriental medical theory and he did a profound research on Simpo(心包). "Oegyeongmieon(外經微言)" is one of his books recording his oriental medical theory in detail so it is the good documentary record for observing his theory of the Simpo(心包). So we looked into his theory of Simpo(心包) in "Oegyeongmieon(外經微言)" and also referred to his other books. You might be able to get a viewpoint of utilizing Simpo(心包) in several ways through reading this paper.

Responses of Inferior Olive Neurons to Stimulation of Semicircular Canals. II. Vertical Semicircular Canalss

  • Park, Sah-Hoon;Park, Jong-Seong;Park, Jin-Soon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제7권4호
    • /
    • pp.193-198
    • /
    • 2003
  • In the present study, the vestibularly evoked activity of inferior olive (IO) neurons was examined to investigate the vertical vestibular information transmitted through the vestibulo-olivo-cerebellar climbing fiber pathway. The extracellular recording was made in 74 neurons of the IO of cats, while animals were sinusoidally rotated. Most of vestibularly activated IO neurons responded to the vertical rotation (roll) test and were found in or near the ${\beta}$ subnuclei $(IO{\beta})$. The vestibular IO neurons were activated, when the animal was rotated to the side contralateral to the recording site. In contrast to the observation that the gain of responses of yaw sensitive cells (YSC) was not changed by the rotation frequency, that of the roll-sensitive cells (RSC) decreased as the rotation frequency was increased. Regardless of RSC or HSC, IO neurons showed the tendency of phase-lag in their responses. The alternating excitatory and inhibitory phases of responses of RSC were dependent on the direction of head orientation, the characteristics of which are the null response plane (NRP) and the optimal response plane (ORP). The analysis based on the NRP of RSC showed that vestibular inputs from the ipsilateral anterior semicircular canal induced the NRP of the RSC response at about 45 degree counterclockwise to the longitudinal axis of the animal, and that those inputs were distributed to RSC in the rostral part of $IO{\beta}$. On the other hand, those from the posterior semicircular canal were related with the NRP at about 45 degree clockwise and with the caudal part of the $IO{\beta}$. These results suggest that IO neurons receive and encode the vestibular information, the priority of which seems to be the vertical component of the body movement rather than the horizontal ones.

Development of a Web-Based Program for Cross-Calibration and Record Management of Radiation Measuring Equipment

  • Park, So Hyun;Lee, Rena;Kim, Kyubo;Ahn, Sohyun;Lim, Sangwook;Cho, Samju
    • 한국의학물리학회지:의학물리
    • /
    • 제30권2호
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose: To manage radiation measurement equipment, a web-based management program has been developed in this study. Materials and Methods: This program is based on a web service and Java Server Pages (JSP) and employs compatibility and accessibility. Results: The first step in the workflow has been designed to create accounts for each user or organization and to log in. The program consists of two parts: fields for listed instruments, and measurement information. The instruments for measuring radiation listed in this program are as follows: ionization chambers, survey meters, thermometers, barometers, electrometers, and phantoms. Instrument properties can be put in the recording fields and browsing for associated instruments can be performed. The main part of the program is the cross-calibration for each ion chamber. For instance, the ionization chamber to be used as a relative dosimeter can be registered by cross-calibration data with a reference chamber calibrated by an accredited laboratory. This program supports methods using the central axis transfer theory for cross-calibration for the ionization chambers. The reference and field ionization chambers were placed in a solid water phantom along the beam central axis at two different depths, and then the positions were switched. Each measured value was used for calculating the cross-calibration factor. Conclusions: Because many instruments are used and managed in radiation oncology departments, systematic, traceable recording is very important. The web-based program developed in this study is expected to be used effectively in the maintenance of radiation measurement instruments.