• Title/Summary/Keyword: Medical radioisotope

Search Result 115, Processing Time 0.03 seconds

Medical Application of Radiation Internal Dosimetry (방사선 내부흡수선량의 의학적 적용)

  • Kim, Kyeong-Min;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.164-171
    • /
    • 2008
  • Medical internal radiation dosimetry (MIRD) is an important part of nuclear medicine research field using therapeutic radioisotope. There have been many researches using MIRD for the development of new therapeutic approaches including radiopharmaceutical, clinical protocol, and imaging techniques. Recently, radionuclide therapy has been re-focused as new solution of intractable diseases, through to the advances of previous achievements. In this article, the basic concepts of radiation and internal radiation dosimetry are summarized to help understanding MIRD and its application to clinical application.

Development of Good Manufacturing facility for Radiopharmaceuticals (우수방사성의약품 생산시설 개발)

  • Shin, Byung-Chul;Choung, Won-Myung;Park, San-Hyun;Lee, Kyu-Il;Park, Kyung-Bae;Park, Jin-Ho
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.2
    • /
    • pp.145-149
    • /
    • 2003
  • Manufacturing facilities of the pharmaceuticals must meet certain level of the cleanness required so that foreign substances such as dust, moisture, heat, microorganism, or virus do not contaminate the product. In case of radiopharmaceuticals for medical treatment and diagnosis, not only should the operators and environment be protected from radiation but also need to be isolated from the foreign contaminant. Therefore, manufacturing facilities for radiopharmaceuticals must satisfy the design standards of both hot cell and clean room which are specified by GMP. However, standards of maintaining negative pressure for preventing spread of radioactive contaminant in isolated facilities conflict with the standards of maintaining positive pressure for keeping cleanness. To solve this problem, air pressure of hot cell was designed lower than in the adjacent area to meet standards of the radiation safety. To keep higher cleanness in certain part of the hot cell for filling, minimal relative positive pressure allows. In order to effectively maintain the cleanness that is required for production of Tc-99m generator, which takes 70% of whole demand of radiopharmaceuticals, the rooms placed in each side of production room are used as a buffer area and three lead hot cells are installed in production room. In this research, we established the appropriate engineered design concept for Tc-99m generator manufacturing facility, which satisfies both GMP cleanness standard for preventing particles, bacteria, other contaminants and the regulations of radiation safety for supervising and controlling the amount of radiation exposure and exhausted radioactivity. And the concept of multi-barrier buffer zones is introduced to apply negative air pressure for hot cell with first priority and to continue relative positive air pressure for clean room.

Radiological and Ultrasonographic Examination in Diagnosis of Diseases of Biliary system (담도계질환(膽道系疾患)의 방사선(放射線) 및 초음파검사(超音波檢査)에 대한 고찰)

  • Son, Tae-Hyu;Kang, Shin-Hwa
    • The Journal of the Korean life insurance medical association
    • /
    • v.3 no.1
    • /
    • pp.90-102
    • /
    • 1986
  • The gallbladder is a pear-shaped, thin walled sac located on the inferior surface of the liver between the right and quadrate lobe, in a recess called fossa vesicae felleae. It is 7.5cm-12.5 cm in length, 3.5 cm in the largest width, and has a volume of about 45 ml with a remarkable capacity for expansion. There are many kinds of diagnostic methods to evaluate diseases of biliary tract including gallbladder-Plain abdomen, Oral cholecystography. Intravenous cholangiography, Percutaneous transhepatic cholangiography(PTC), Endoscopic retrograde cholangiography(ERCP), Operative or T-tube cholangiography, Ultrasonography, Radioisotope study, Computed tomography, and Angiography. Especially, ultrasonography is the most effective and noninvasive study in these days. Plain abdomen, oral cholecystography, intravenous cholangiography, and ultrasonography have been performed in our clinic. Methods and findings of above mentioned study are discussed with consideration of references.

  • PDF

Synthesis and evaluation of metal purine-type complexes for lung cancer imaging

  • Kang, Kyeung Jun;Ko, In Ok;Park, Ji-Ae;Kim, Jung Young
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.61-68
    • /
    • 2019
  • Purine type compounds has been recently reported to cause the death for lung cancer cell, related to microtubules-targeting agents (MTAs). Therefore it can be used to develop as theranostic radiopharmceuticals in nuclear medicine or gadolinium-based MRI imaging agents by chelate chemistry. In the study, we tried to chemically bind a DOTA chelate on the end of purine compound and obtained a specific conjugate of DOTA-purine for metal coordination. In particular, radiometal like Cu-64, for the development of MRI imaging agents, can be utilized to choice good candidates before the synthesis of gadolinium complexes. By the screening of radioisotope technique, Gd-DOTA-purine type complex was successfully prepared and showed MRI imaging for lung cancer cell into the mouse model.

Self Production of Radioisotope and Radiopharmaceuticals Divider (방사성동위원소 및 방사성의약품 분주장치의 자체제작)

  • Hong, Sung-Tack;Park, Kwang-Seo;Kim, Seok-Ki;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.177-180
    • /
    • 2010
  • Purpose: As PET test came to be covered by the pay system of medical insurance (July 1, 2006) and the needs for it becoming increased for laboratory purpose, it became necessary to purchase expensive medical equipments to solve those problems. However, as most of equipments that are operated by cyclotron are very expensive as to amount from tens of millions up to hundreds of millions of won, it is difficult to purchase those equipments from the point of medical organizations. It may be possible to self manufacture those equipments with least costs if their parts functions that meets the operators demands. The Nuclear Medicine department of National Cancer Center (NCC) is trying to manufacture and use equipments that can be made with least costs, including introducing 2 medical equipments that can improves the operator's works. Materials and Methods: Example 1: Self production of radioisotope($^{18}F$) divider was fabricated. The NCC's Nuclear Medicine department acquired one acrylic panel, seven 3-way valve, tubing etc. that can be found in the market to make the main body of divider in cooperation with biomedical engineering, and placed them inside hot cell, and installed switching box outside of hot cell to make it possible to control them from outside. This main body of divider were placed in radioisotope transfer line that are manufactured in the cyclotron. Example 2: Self production of $^{18}F$-FDG automated divider was fabricated. The NCC's Nuclear Medicine department used cavro pump syringe that consists the main body of divider in cooperation with biomedical engineering, biomedical engineering developed programs that divides a certain amount. $^{18}F$-FDG automated divider is placed inside hot cell, and cable chords were used in the equipment, and then it was connected to PC outside hot cell to make it possible to control the $^{18}F$-FDG automated divider. Results: From the NCC's Nuclear Medicine department tests that were carried out from March, 2007 until now, we found out that radioisotope can be sent to radiopharmaceuticals composite module we want, and from the tests that are carried out at NCC's Nuclear Medicine department using $^{18}F$-FDG automated divider since August, 2009 it was possible to distribute radiopharmaceuticals into vial intended. Conclusion: Through the two examples above, we found out that costs can be reduced by self manufacturing expensive equipments from NCC's cyclotron room with least costs. Also, it decreased radiation exposure dose on workers, and set up problem solving processes in cooperation with lots of parties related.

  • PDF

Development of Computer-based 2-D Radiation Therapy Planning System (컴퓨터를 이용한 통합적 2차원 방사선치료계획장치 개발)

  • Suh, T.S.;Yoon, S.C.;Suh, D.Y.;Kim, M.C.;Lee, H.K.;Choe, B.Y.;Shinn, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.64-65
    • /
    • 1998
  • The aim of this work is to develop computerized 2-D radiation therapy planning system. The algorithms to compute dose for photon, electron, radioisotope have been developed, and dose distributions were superimposed on CT or MR images. Using object oriented modeling the structure of program has been designed for the efficient user-interface. Finally, a prototyp of 2-D radiation therapy planning system has been successfully applied in clinical cases for the demonstration.

  • PDF

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.

Development of bombesin peptide kit for prostate cancer diagnosis and treatment using 64Cu/177Lu.

  • Kim, Mi Hyun;Kim, Min Hwan;Kim, Kwang Il;Kim, Jung Young;Lee, Tae Sup;Kang, Joo Hyun;Lee, Kyo Chul;Lee, Yong Jin
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.59-64
    • /
    • 2017
  • It has been reported that $^{64}Cu$ was radiolabeled with bombesin (BBN) peptide binding to the gastrin releasing peptide receptor expressed in human prostate cancer cells (PC3), confirming tumor target efficacy in mouse model. In this study, we developed the kit for the diagnosis and treatment of prostate cancer that can be used clinically using bombesin peptide available of $^{64}Cu$ and $^{177}Lu$ radioisotope labeling. The NODAGA-galacto-BBN peptide containing the NODAGA chelator and galactose was dispensed into a sterilized glass vial and lyophilized to prepare a kit. The stability of the kit after long-term storage in the $4^{\circ}C$ cold chamber and the radiolabeling efficiency after $^{64}Cu$ or $^{177}Lu$ labeling were confirmed by thin layer chromatography. When labeling with $^{64}Cu$ at the initial stage of storage, labeling efficiency of NODAGA-galacto-BBN peptide kit was over 96%, labeling efficiency was over 90% when $^{177}Lu$ was labeled. At 11 months after storage, the radiolabeling efficiency of kit against $^{64}Cu$ and $^{177}Lu$ was each over 95% and 90%. The cell viability was significantly reduced in the $^{177}Lu$-NODAGA-galacto-BBN treated group compared with the control and $^{177}Lu$ alone treated group in clonogenic assay. In conclusion, the NODAGA-galacto-BBN kit prepared by the lyophilization showed high stability over time and high yield of radioisotope labeling. Also $^{177}Lu$-NODAGA-galacto-BBN confirmed high cytotoxicity to prostate cancer cells. Therefore, the NODAGA-galacto-bombesin kit is expected to be useful for the diagnosis and treatment of prostate cancer patients.

Spontaneous Intracranial Hypotension (자발성 두개강내압 저하증)

  • Kong, Doo Sik;Kim, Jong Soo;Park, Kwan;Nam, Do Hyun;Eoh, Whan;Shin, Hyung-Jin;Hong, Seung-Chyul;Kim, Jong Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.2
    • /
    • pp.240-248
    • /
    • 2000
  • Objective : Spontaneous intracranial hypotension is a rarely reported syndrome of spontaneous postural headache associated with low CSF pressure and has rarely been demonstrated radiographically or surgically. But recently, it is being recognized with increasing frequency. The purpose of this study was to characterize clinical and imaging features, etiologic factors, and outcome in the spontaneous intracranial hypotension. Patients and Methods : We reviewed our experience with documented cases of spontaneous intracranial hypotension in 5 consecutive patients with orthostatic headaches from April 1998 to April 1999. Results : The mean age was 41 years(from 35 to 49 years). All patients had postural headaches, which were completely alleviated by recumbency position. Nausea, neck pain, horizontal diplopia, photophobia, and blurred vision were noted in some of the patients. Brain MRI showed diffuse pachymeningeal gadolinium enhancement, subdural collections of fluid, and descent of the brain. The opening pressure from lumbar puncture was $4cmH_2O$ or less in three of five patients whereas the opening pressure was within normal range in two patients. All patients underwent radioisotope cisternography and computerized tomographic myelography. On radioisotope cisternography, CSF leakage was suspected at the level of cervical area(1 patient), upper thoracic area(2 patients), mid-thoracic area(1 patient). Computed tomography myelography revealed extraarachnoid accumulation of contrast media(compatible finding with CSF leakage) at the level of cervical or thoracic area. In all patients, the symptoms resolved in response to supportive measures or epidural blood patch(1 patient). Conclusion : Spontaneous spinal CSF leakage is increasingly recognized as a cause of spinal postural headache. Most CSF leaks are located at the cervicothoracic junction or in the thoracic spine and can be demonstrated by variable diagnostic method. The condition is usually self-limiting and its prognosis is typically good.

  • PDF

Incidental Detection of a Pseudoaneurysm at an Amputation Stump in a Tc-99m HMPAO labeled Leukocyte Scan (Tc-99m HMPAO 표지 백혈구스캔상 대퇴 절주에서 우연히 발견된 가성동맥류)

  • Sohn, Myung-Hee;Jeong, Hwan-Jeong;Lim, Seok-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.337-338
    • /
    • 2007
  • A 20-year-old man underwent a Tc-99m HMPAO labeled leukocyte scan for the evaluation of an infection at the stump of an AK amputation, which was conducted due to an open communicated fracture of the left lower leg. Blood-flow and blood-pool images demonstrated a pseudoaneurysm with a focus of intense activity medial to the stump, and centered within a large photopenic defect by surrounding hematoma. Delayed image obtained at 3 hours post-injection showed persistent intense and slight increased activity, Contrast angiography confirmed the presence of a pseudoaneurysm arising from a branch of the left superficial femoral artery.