• 제목/요약/키워드: Medical radioisotope

검색결과 115건 처리시간 0.024초

Perceptions of Residents in Relation to Smartphone Applications to Promote Understanding of Radiation Exposure after the Fukushima Accident: A Cross-Sectional Study within and outside Fukushima Prefecture

  • Kuroda, Yujiro;Goto, Jun;Yoshida, Hiroko;Takahashi, Takeshi
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.67-76
    • /
    • 2022
  • Background: We conducted a cross-sectional study of residents within and outside Fukushima Prefecture to clarify their perceptions of the need for smartphone applications (apps) for explaining exposure doses. The results will lead to more effective methods for identifying target groups for future app development by researchers and municipalities, which will promote residents' understanding of radiological situations. Materials and Methods: In November 2019, 400 people in Fukushima Prefecture and 400 people outside were surveyed via a web-based questionnaire. In addition to basic characteristics, survey items included concerns about radiation levels and intention to use a smartphone app to keep track of exposure. The analysis was conducted by stratifying responses in each region and then cross-tabulating responses to concerns about radiation levels and intention to use an app by demographic variables. The intention to use an app was analyzed by binomial logistic regression analysis. Text-mining analyses were conducted in KH Coder software. Results and Discussion: Outside Fukushima Prefecture, concerns about the medical exposure of women to radiation exceeded 30%. Within the prefecture, the medical exposure of women, purchasing food products, and consumption of own-grown food were the main concerns. Within the prefecture, having children under the age of 18, the experience of measurement, and having experience of evacuation were significantly related to the intention to use an app. Conclusion: Regional and individual differences were evident. Since respondents differ, it is necessary to develop and promote app use in accordance with their needs and with phases of reconstruction. We expect that a suitable app will not only collect data but also connect local service providers and residents, while protecting personal information.

고용량 방사성옥소 치료병실의 오.폐수 저감화를 위한 연구 (On decrease program of Radioactive Wastewater and Sewages in High Dose Radioiodine Therapy Ward)

  • 류재광;정우영;신상기;조시만
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.19-26
    • /
    • 2008
  • 목적: 방사성옥소 치료병실로부터 발생한 오 폐수는 반드시 전용 정화조에서 일정시간 자연 감쇄(decay)시켜 수중 방사능 농도치가 $8.1{\times}10^{-13}$ Ci/ml 이하가 될 때에만 비로소 방류를 하여야 한다. 현재까지 서울아산병원에서는 60 ton 용량의 전용정화조 3개를 구비하여 운영하고 있었지만 2005년 10월부터 방사성옥소 치료병실을 2병상에서 4병상으로 증설 운영함에 따라 급격히 늘어난 방사성 오.폐수량으로 인하여 본원의 정화조 용량으로는 충분한 감쇄(약 125일 이상)여력이 부족하게 되었다. 따라서 본 연구에서는 치료병실 정화조의 오 폐수 유입유량에 기여하는 원인 및 요인들을 밝혀내어 합리적인 개선 조치를 함으로써 정화조 용량 부족 문제를 해결하여 1차적으로는 엄청난 병원의 경제적 손실을 유발시키는 새로운 정화조의 증설을 피하고 방사성 물질의 인위적 배출로 인한 사회적 문제 유발에 따른 대형의료기관의 신뢰도 추락의 예방에 큰 목적이 있다. 대상 및 방법: 2006년 1월부터 10월까지 고용량 옥소 치료 환자 중 150~200 mCi 이상을 투여 받고 2박3일간 입원치료를 하는 환자 402명을 대상으로, 환자 1인당 평균 물 사용량 (변기사용량, 샤워량, 세면량, 기타 등등)을 측정하였으며, 본원의 정화조 60 ton 3개의 만수 후 배출까지의 감쇄 기간을 측정하였다. 또한 본원의 치료 업무 절차를 단계별로 분석하여 정화조 유입유량의 증가 요인을 찾아보았다. 결과: 다음과 원인에 대한 개선을 통하여 본원의 방사성 오 폐수 보관일수를 정화조 1개당 84일에서 2005년 12월말 현재 약 130일로 증가시킬 수 있었다. (1) 기존 변기의 과다한물 소모량 개선 $\rightarrow$ 절수형 변기로 교체 (2) 불필요한 샤워 및 세탁 방지 $\rightarrow$ 샤워 노즐 사용 자제 및 세면대 이용 교육 (3) 치료기간 중 잦은 배뇨를 유발하는 이뇨제 복용 중지 (4) 수분 섭취량과 퇴원시 체내 잔류선량과의 상관관계 분석 (5) 입실 후 치료 전까지의 대기시간에는 외부 화장실 사용 교육 (6) 정화조 만수위 용량 한계치를 최대 85%에서 90%로 증대 운용 결론: 근래에 들어 급격하게 증가된 갑상선질환 관련 환자로 인하여 전국적으로 거의 모든 의료기관에서 방사성옥소치료의 대기일 수가 크게 증가되고 있다. 이러한 시점에 발생된 방사성 오 폐수 관련 문제는 비단 어느 한 의료기관의 문제가 아닌 관련 우리 모두가 해결해야 하는 큰 과제임에 틀림 없을 것이다. 따라서 본 개선 활동은 그 시작을 알리는 신호탄이 될 것이라 생각되며 방사성 치료병실을 운영하고 있는 타 의료기관에서도 이와 관련된 유사상황이 발생된다면 합리적인 정화조운영의 모델방안으로 제시 될 수 있을 것으로 기대된다.

  • PDF

방사성요오드(I-131) 격리병실 치료 관리를 위한 환자의 체외방사선량률과 상주 보호자의 피폭선량평가 (Evaluation of Caregivers' Exposed Dose and Patients' External Dose Rate for Radioactive Iodine (I-131) Therapy Administration in Isolated Ward)

  • 강석진;이두현;소영;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.347-353
    • /
    • 2022
  • In this study, the radiation dose rate was measured by time and distance and evaluated whether radiation dose rate was suitable for domestic and international discharge criteria. In addition, the radiation dose emitted from the patient was measured with a glass dosimeter to evaluate the exposure dose if the caregiver stays in the isolated ward by placing a humanoid phantom instead of the caregiver at a distance of 1 m from the patient, on the second day of treatment. After 23 hours of isolation, the radiation dose rates at a distance of 1 m were 20.54 ± 6.21 µSv/h at 2.96 GBq administration and 27.94 ± 12.33 µSv/h at 3.70 GBq administration. The radiation dose rates at a distance of 1 m were 25.90 ± 2.21 µSv/h when 2.96 GBq was administered and 34.22 ± 10.06 µSv/h when 3.70 GBq was administered after 18 hours of isolation. However, if the isolation period is short may cause unnecessary radiation exposure to the third person. The reading of the attached dosimeter from the morning of the second day of treatment until removal was 0.01 to 0.95 mSv, which is a surface dose determined by the International Commission on Radiation Units and Measurements. And the depth dose was 0.01 to 0.99 mSv. On the second day of treatment, even if the patient caregivers stayed in the isolation ward, the exposure dose of the patient family did not exceed the effective dose limit of 5 mSv recommended by the ICRP and NCRP.

사백산(瀉白散)이 Compound 48/80에 의하여 유도(誘導)된 Anaphylatic shock와 피하반응(皮下反應)에 미치는 영향(影響) (Effects of Sabaiksan on the Compound 48/80 Induced Anaphylatic Shock and Cutaneous Reaction)

  • 김민호;한상환;전병득
    • 대한한방내과학회지
    • /
    • 제11권2호
    • /
    • pp.22-42
    • /
    • 1990
  • Sabaiksan has been prescribed to treat various allergic diseases in herbal medicine which were induced by various vasoactive amine released from the mast cells. The constituents of Sabaiksan are Mori Cortex Radices(MCR), Lycii Cortex Radicis(LCR) and Glycyrrhizae Radix(GR). Recently, simple models of compound 48/80 induced anaphylactic shock and cutaneous reaction in vivo were developed to test various agents employed in the field of allergy and toxicology research. The purpose of this study is to evaluate the effects of Sabaiksan on compound 48/80 induced anaphylactic stock, cutaneous reaction and mesenteric mast cell degranulation rate in ICR mice, and on compound 48/80 induced peritoneal mast cell degranulation and histamine release in vitro. Groups of ICR mice were intraperitoneally pretreated with $100{\mu}{\ell}$ of saline, $MCR(2g/m{\ell}),\;LCR(2g/m{\ell}),\;GR(g/m{\ell})$ or Sabaiksan itself(MCR+LCR+GR) at 24, 12 and 1 hour before compound 48/80 solution ($10{\mu}{\ell}/gm$ B. W) were peritoneally given into them, and then mortality within 72 hours after the compound 48/80 injection, and mesenteric mast cell degranulation rate at 15 minutes after compound 48/80 injection were calculated. In vitro experiment, $400{\mu}{\ell}$ of rat peritoneal mast cell suspension$(10^6cell/m{\ell})$ were pretreated with $50{\mu}{\ell}$ of saline, $MCR(2g/m{\ell}),\;LCR(2g/m{\ell}),\;GR(g/m{\ell})$ or Sabaiksan itself at room temperature for 30 minutes, and then $50{\mu}{\ell}$ of compound 48/80 solution $(100{\mu}g/m{\ell})$ were added into it. 30 minutes after the addition of compound 48/80 solution, histamine release assay in the supernatant of peritoneal mast cell suspension were performed employing radioisotope enzymatic assay and morphologic changes of mast cells in each regular time point were photographed. Compared with controls, compound 48/80 induced anaphylactic shock was significantly inhibited by MCR and GR pretreatment into the ICR mice. Significant inhibition of compound 48/80 induced cutaneous reaction, mesenteric mast cell degranulation rate in vivo and histamine release from the rat peritoneal mast cells in vitro was observed only in MCR pretreated group. From the above results, it is suggested that MCR component of Sabaiksan may playa key role to suppress mast cell function since it has been applied to various allergic diseases.

  • PDF

방사성물질을 이용한 치료의 안전관리 고찰 (Radiation Safety Consideration Regarding the Treatment which uses the Radioactive Substance)

  • 임청환;김승철;이귀원
    • 한국콘텐츠학회논문지
    • /
    • 제8권11호
    • /
    • pp.217-224
    • /
    • 2008
  • 방사성 물질 중 동위원소를 이용한 치료는 1964년부터 현재까지 꾸준히 증가하는 추세이다. 그에 따른 안전관리도 강화 되었다. 그러나 현재 규정과 제도가 오히려 치료행위에 악영향을 주거나 이를 회피하기 위한 수단으로 임상에서 치료병동을 개설하지 아니하고 소량의 방사능으로 치료를 하고 있으며, 치료병동이 있다 하더라도 그 시설을 감당하지 못하고 많은 입원환자를 유치하지 못함으로 인하여 환자가 치료를 받기위해 상당기간 동안 대기하여야 한다. 최근 원자력의학원에서 기존 병실을 포함한 약 10개 병실을 보유하게 되어 대기 상태가 해소된 듯 보여 지지만 현재 국내에서 약 28개 병원에서만 총 57개의 방사성 동위원소 병실을 사용 하고 있어 아직 까지도 상당기간 치료를 위하여 대기하고 있는 실정이다. 따라서 환자는 호르몬 조절시간이 장기화 되고 치료병실이 없는 의료기관에서는 최대 방사능 30mCi로 수차례에 걸쳐 시행하게 된다. 이는 환자, 가족, 지인 등에게 수회에 걸쳐 피폭을 주는 결과를 발생시킬 것이다. 또한 의료인 및 보건의료인이 환자 및 보호자에게 피폭에 대한 고지의무를 다한다 하더라도 환자를 비롯한 가족에게는 상당한 심적 부담감을 줄 수 있을 것이다. 그러므로 현재 3차 진료에 해당하는 병원 및 의료기관에서는 치료병실을 설치해야하는 필수 조건으로 의무화 하는 등 방사성동위원소 치료에 따른 시설 강화와 제도 개선의 노력이 있어야 할 것이다.

진단방사선검사에서 환자피폭선량에 관한 연구 (Patient exposure doses from medical x-ray examinations in Korea)

  • 김유현;최종학;김성수;오유환;이창엽;조평곤;강대현;이영배;김형철;김철민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권3호
    • /
    • pp.241-248
    • /
    • 2005
  • 진단방사선검사 중에 환자가 받는 X-선량은 인위적으로 만들어낸 방사선피폭 중 가장 큰 비중을 차지하고 있다. 국제적으로 방사선피폭에 대한 진단참고준위가 제안되고 있으며 IAEA는 진단방사선검사와 방사성동위원소검사를 위한 유도준위(guidance level)를 정하여 각국의 실정에 맞게 사용하도록 권고하고 있다. 따라서 다수의 나라에서는 자국의 실정에 맞는 진단참고준위를 정하고자 진단방사선검사에서 환자피폭에 관한 상황을 조사 분석하고 있다. 본 연구는 한국의 실정에 맞는 진단방사선검사에서의 진단참고준위를 설정하고자 일반 X-선촬영, 투시촬영, 전산화단층촬영, 유방촬영 시 환자피폭선량값을 측정하여 NDD법에 의해 계산된 선량과 비교 검토하여 진단참고준위를 제시하고자 수행하였다.

  • PDF

몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구 (Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT)

  • 한무재;허승욱;신요한;정재훈;김교태;허예지;이득희;조흥래;박성광
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.141-146
    • /
    • 2019
  • 산업 비파괴 분야에서 사용되는 방사선원은 장비의 노후화 및 작업자의 부주의로 인해 선원이 노출되는 사고가 발생되어 왔다. 이에 선원의 위치를 실시간으로 추적할 수 있는 안전관리 시스템의 필요성이 부곽되고 있다. 이에 본 연구에서는 방사선원의 위치 추적을 위한 line-array 선량계를 구성하는 unit-cell 선량계 단위의 각도의존성을 분석하기 위해 Monte Carlo Simulation을 수행하였다. 그 결과 각 기울기에서 상위 10% 수치에 대한 오차율은 $0^{\circ}$에서 5.90%, $30^{\circ}$에서 8.08%, $60^{\circ}$에서 20.90%의 오차율을 보였다. 총 흡수선량의 비율은 $0^{\circ}$(100%)를 기준으로 $30^{\circ}$에서 83.77%, $60^{\circ}$에서 53.36%로 나타났으며 기울기가 증가함에 따라 낮아지는 경향성을 보였다. 모든 기울기에서 최대 수치는 $30^{\circ}$의 No. 9에서 나타났으며, No. 10에서는 7.24% 낮아지는 경향성을 보였다. 본 연구 결과 각도의존성은 크게 발생되는 것으로 나타났으며, 이를 낮추기 위해서는 선원과 line-array 선량계의 적정거리는 1 cm 이상의 거리에서 유지해야 하는 것으로 사료된다.

고선량율(高線量率) 강내조사법(腔內照射法)을 이용(利用)한 자궁경암(子宮頸癌) 방사선(放射線) 치료(治療) (The Treatment of Uterine Cervical Cancer Using High Dose Rate Co-60 Sources)

  • 김귀언;서창옥;이도행;박창윤
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.95-102
    • /
    • 1983
  • The radical treatment of uterine cervical cancer by interacavitary radium or cesium, in combination with teletherapy are well known. Although the result of such treatment should not give rise to complacency, problem of radiation exposure to medical staff had not been resolved. Fortunately, many attempts have been made to reduce this hazard, most of which take the form of afterloading applicators with a suitably shielded radioisotope. In order to avoid hazardous radiation exposure to staffs concerned with brachytherapy, RALS using high intensity source of Co-60, have been employed at Yonsei Cancer Center since May, 1979. It allows rectal and bladder doses to be kept low, while maintaining a satifactory usual dose distribution of the other type of applicators, and the short treatment time allow four or five patients to be treated per hour. It also removes much patient's discomfort and the difficulties of nursing these patients. Since the first introduction in Korea, over seven hundred cases with various stage of uterine cervical cancer have been treated on a radical basis at this center last 4 years. These authors have strongly attracted attention to the results in terms of local control rate, survival s and morbidity compared with those of conventional low dose rate radiotherapy. Retrospective interim analysis of data was preliminarily accomplished through the labored follow-up study of 340 cases treated during initial 2 years and the radiobiologic standpoint of high dose rate intracavitary irradiation will be discussed.

  • PDF

Application of extraction chromatographic techniques for separation and purification of emerging radiometals 44/47Sc and 64/67Cu

  • Vyas, Chirag K.;Park, Jeong Hoon;Yang, Seung Dae
    • 대한방사성의약품학회지
    • /
    • 제2권2호
    • /
    • pp.84-95
    • /
    • 2016
  • Considerably increasing interest in using the theranostic isotopes/ isotope pairs of radiometals like $^{44/47}Sc$ and $^{64/67}Cu$ for diagnosis and/or therapeutic applications in the nuclear medicine procedures necessitates its reliable production and supply. Separation and purification of no-carrier-added (NCA) isotopes from macro quantitates of the irradiated target matrix along with other impurities is a cardinal procedure amongst several other steps involved in its production. Multitudinous methods including but not limited to liquid-liquid (solvent) extraction, extraction chromatography (EXC), ion exchange, electrodeposition and sublimation are routinely applied either solitarily or in combination for the separation and purification of radioisotopes depending on their production routes, radioisotope of interest and impurities involved. However, application of EXC though has shown promises towards the numerous separation techniques have not received much attention as far as its application prospects in the field of nuclear medicine are concerned. Advances in the recent past for application of the EXC resins in separation and purification of the several medically important radioisotopes at ultra-high purity have shown promising behavior with respect to their operation simplicity, acidic and radiolytic stability, separation efficiencies and speedy procedures with the enhanced and excellent extraction abilities. In this mini review we will be talking about the recent developments in the application and the use of EXC techniques for the separation and purification of $^{44/47}Sc$ and $^{64/67}Cu$ for medical applications. Furthermore, we will also discuss the scientific and practical aspects of EXC in the view of separation of the NCA trace amount of radionuclides.

몬테카를로 모의 모사를 이용한 핵의학과 방사선작업종사자의 손에 대한 피폭선량 분석 (An Analysis of Exposure Dose on Hands of Radiation Workers using a Monte Carlo Simulation in Nuclear Medicine)

  • 장동근;강세식;김정훈;김창수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.477-482
    • /
    • 2015
  • 핵의학과에 근무하는 방사선작업종사자들은 방사성동위원소의 생산, 분배, 조제, 주입 등의 업무를 진행하며, 이러한 과정에서 손에 대한 방사선 피폭이 높게 발생한다. 이에 본 연구에서는 핵의학과에서 이용되는 방사성동위원소의 에너지로서 140 keV와 511 keV의 ${\gamma}$선에 대한 차폐효과를 몬테카를로 모의 모사를 통해 분석하였다. 모의실험 결과 140 keV ${\gamma}$선은 차폐체에 두께와 상관없이 모두 방사선에 대한 차폐효과가 발생되었으며, 511 keV의 ${\gamma}$선에서는 1.1 mm 이상에서 차폐효과가 발생되었다. 그러나 1.1 mm 미만에서는 2차적으로 발생된 산란선으로 인하여 차폐효과가 없었으며, 오히려 방사성동위원소의 피폭선량이 증가되었다. 따라서 효율적인 방사선 방어를 위해서는 핵종별 에너지에 따른 납 차폐체의 두께를 고려하여야 할 것이다.