• Title/Summary/Keyword: Medical measurement

Search Result 2,743, Processing Time 0.032 seconds

Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image ($T_2^*$ and FLAIR) Sequence (뇌의 확산강조 영상에서 b-value의 변화에 따른 신호강도, 현성확산계수에 관한 비교 분석 : 확산강조 에코평면영상($T_2^*$ 및 FLAIR)기법 중심으로)

  • Oh, Jong-Kap;Im, Jung-Yeol
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.313-323
    • /
    • 2009
  • Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in $T_2^*$-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  • PDF

The Clinical Aspects of Regional Lymphadenitis following BCG Vaccination (BCG 접종 후 국소 림프절염의 임상양상)

  • Bae, Sun Young;Park, Yang Joon;Kim, Jong-Hyun;Oh, Jin Hee;Koh, Dae Kyun;Kang, Jin Han
    • Pediatric Infection and Vaccine
    • /
    • v.13 no.2
    • /
    • pp.137-146
    • /
    • 2006
  • Purpose : A regional lymphadenitis is the most frequent adverse reaction of BCG. In order to find out developmental factors and establish a strategy of management, we investigated the clinical courses of children with lymphadenitis following BCG on the aspect of BCG strains, suppurative rates according to the sizes of lymph node and the clinical difference with or without treatment. Methods : From January 1997 to June 2004, 52 children less than 24 month-age-old diagnosed as BCG lymphadenitis in Department of Pediatrics, St. Vincent's Hospital, The Catholic University of Korea were enrolled. The type of BCG strain, place of vaccination, location and size of lymphadenitis were assessed with medical records, retrospectively. Finally, we analysed the correlations between BCG strains or the sizes of lymph node and natural remission or suppuration. Results : The first detected mean age of BCG lymphadenitis was 5.5 month-age. The larger of the measurement was at the first visiting, the younger of age that was first presented. The most frequent location was the same sided axillary region of BCG injection. Among 52 subjects, 46 cases(88.5%) were vaccinated with intradermal Pastuer strain, and only 5 cases(9.6%) were done with percutaneous multipunctured Tokyo strain. Twenty eight cases(53.8%) were regressed naturally, otherwise 24 cases(46.2%) were suppurated. The larger those were sized, the higher freqeuncies those were suppurated on, significantly. Treatment with medications could not prevent the suppuration and could not shorten the healing periods. Conclusion : We predict that there are differences between the occurrent rate of BCG lymphadenitis and BCG strains or methods. Treatment with medication is not recommended owing to its ineffectiveness. Especially, in case of non-suppurative lymphadenitis should be onlyless influence on the tuberculin skin test, cause less adverse reactions, and is inexpensive. observed without treatment, because it could be regressed naturally. An ideal BCG makes a scar, We should make an effort to choose the best BCG strain that can fulfill such requirements.

  • PDF

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

Quality of Life Changes in Patients Admitted to the Hospice Unit (호스피스 병동 입원 환자의 삶의 질 변화)

  • Park, Theresia;Song, Hae-Hiang;Seo, In-Ok;Cho, Young-Yee;Park, Myung-Hee;Heo, Jeong-Hee;Kim, Eun-Kyung;Park, Sun-Ju;Ra, Jeong-Ran
    • Journal of Hospice and Palliative Care
    • /
    • v.3 no.1
    • /
    • pp.18-27
    • /
    • 2000
  • Purpose : This study aims to find out the quality of life of patients admitted to the hospice unit at Kangnam St. Mary's Hospital, at admission and after weeks hospice service and to assess the effects of hospice service on the quality of life of terminal cancer patients. Methods : This study subjects were 100 patients admitted to the hospice unit at Kangnam St. Mary's Hospital, Catholic University between October 1999 and March 2000, and their primary caregivers. Quality of life data were collected using a questionnaire revised by the authors and were analyzed by means of repeated measures ANOVA. Results : 1) Patient's quality of life as perceived by the primary caregiver was significantly improved and the mean score was 3.31, 3.68, 3.56, 3.73, 3.75 at admission and week 1, 2, 3, 4. With the detailed item analysis, the following items were shown to be significantly improved: "clean bodies"(F=6.50, P=0.0001) "pain control"(F=18.01, P=0.0001) constipate"(F=2.96, P=0.0237) "sleep"(F=3.99, P=0.0048) "nausea/vomiting"(F=4.50, P=0.0022) "medical team's comfortable care" (F=3.95, P=0.0051) "family's care"(F=2.76, P=0.0317) "anxiety" (F=3.14, P=0.0177) "comfort"(F=3.63, P=0.0085) "treat with dignity"(F=3.32, P=0.0136). The item of "death is not the end of life rather the beginning" was significantly decreased(F=2.54, P=0.0450). 2) Patient's quality of life as perceived by the patient showed an improvement but statistically insignificant and the mean score was 3.63 and 3.83 at admission and week 1. With the detailed item analysis, the item of "pain control" was shown to be significantly improved(F=9.19, P=0.0251). 3) The quality of score in the last week of life of patient were 3.48, 3.51, 3.44, 3.46, 3.50, respectively, from 5 week prior to 1 week prior to death and these changes were insignificant. Conclusion : The findings of this study showed a positive effect of hospice service on quality of life of the terminal cancer patients admitted to the hospice unit. To improve the quality of life, we need first of all to develop hospice interventions with a particular emphasis on the spiritual aspect of patient. Secondly, measurement instruments need to be developed to collect the quality of life of the hospice patients who become weakened especially in the last weeks of their life and with this effort more representative data of hospice patients may be collected.

  • PDF

Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve (기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템)

  • 이혁수
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.421-430
    • /
    • 2004
  • Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

Effect of Noise in Human Body (소음이 인체에 미치는 영향)

  • 이영노
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.7-8
    • /
    • 1972
  • The effects of noise exposure are of two types: Nonauditory effects and auditory effects. Nonauditory effects of noise exposure are interference with communication by speech, sleeping and emotional behavior. The noise will cause the high blood pressure and rapid pulse, also that decrease the salivation and gastric juice. in experimentaly showed that the Corticoid hormon: Gonatotropic hormone were decrease and Thyrotropic hormoone is increase. Auditory effect of noise exposure. when the normal ear is exposed to noise at noise at hamful intensities (above 90㏈) for sufficiently long periods of time, a temoral depression of hearing results, disappearing after minutes or hours of rest. When the exposure longer or intesity greater is reached the Permanent threshold shift called noise-induced hearing loss. Hearing loss resulting from noise exposure presents legal as well as medical problems. The otologist who examines and evaluates the industrial hearing loss cases must be properly informed, not only concerning the otologic but also about the physical and legal aspects of the problems. The measurement of hearing ability is the most important part of a hearing conservation, both preplacement and periodic follow-up tests of hearing. The ideal hearing conservation program would be able to reduce or eliminate the hazardous noise at its source or by acoustic isolation of noisy working area and two ear protections (plugs and muff type) were developed for personal protection.

  • PDF

Homologous and Heterologous Antibody Response of the Patients with Aspergillosis Against Young Mycelia of Aspergilli by Fluorescence Antibody Reaction (형광항체반응을 이용한 Aspergillus 증 환자의 균사표면항원에 대한 항체반응 양상에 관한 연구)

  • Moon, Hi-Joo;Kwon, Hyuk-Han
    • The Korean Journal of Mycology
    • /
    • v.17 no.2
    • /
    • pp.82-90
    • /
    • 1989
  • Detection of antibody against pathogenic fungi in serum specimens of the patients with pulmonary tuberculosis or other lung diseases has been carried out(male) using the indirect fluorescence antibody technique and immunodiffusion tests. Immunodiffusion tests revealed that 104(36.5%) out of 285 patients examined showed a positive precipitin reaction against one or more of fungal antigens. The majority of ID positive patients 64(61.5%) reacted with Aspergillus fumigatus antigen and 49(47.1%) patients reacted with Candida albicans antigen ID positive reaction to A. fumigatus was found little more frequently among male patients, while Candida albicans reactors were found more frequently among female patients. Age distribution of ID positive reactors was high(49.1-43.3%) in age group of 40-59 years, but least or none in age group of less than 30 years. Age of fungal mycelium used as antigen did not effect sensitivity of the indirect flubrescence (IF) technique in detecting antibody to A. fumigatus. Antibody class against A. fumigatus that showed highest titer was IgG and thus FITC labeled anti-IgG immunoglobulin shoul be preferable. As relatively large amount of cell wall components of Aspergilli shared antigenically, a considerable cross-reaction was observed among A. fumigatus, A. flavus and A. niger, but not much with C. albicans. While (IF) has much better sensitivity when compared with ID, relative specificity of the latter procedure cannot to be overried, so that they could be batter used together in order to obtain quantitative measurement of antibody with relative specificity.

  • PDF

Measurement of thermal expansion characteristic of root canal filling materials : Gutta-percha and Resilon (수 종의 근관충전재의 열팽창 특성 측정 : Gutta-percha와 Resilon)

  • Jeon, Kyung-A;Lee, In-Bog;Bae, Kwang-Shik;Lee, Woo-Cheol;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.344-351
    • /
    • 2006
  • The purpose of this study was to evaluate the thermal expansion characteristics of injectable ther-moplasticized gutta-perchas and a Resilon. The materials investigated are Obtura gutta-percha, Diadent gutta-percha, E&Q Gutta-percha Bar and Epiphany (Resilon). The temperature at the heating chamber orifice of an Obtura II syringe and the extruded gutta-percha from the tip of both 23- and 20-gauge needle was determined using a Digital thermometer. A cylindrical ceramic mold was fabricated for thermal expansion test, which was 27 mm long, with an internal bore diameter of 3 mm and an outer diameter of 10 mm. The mold was filled with each experimental material and barrel ends were closed with two ceramic plunger. The samples in ceramic molds were heated in a dilatometer over the temperature range from $25^{\circ}C$ to $75^{\circ}C$. From the change of specimen length as a function of temperature, the coefficients of thermal expansion were deter-mined. There was no statistical difference between four materials in the thermal expansion in the range from $35^{\circ}C$ to $55^{\circ}C$ (p > 0.05). However, Obtura Gutta-percha showed smaller thermal expansion than Diadent and Metadent ones from $35^{\circ}C$ to $75^{\circ}C$ (p < 0.05). The thermal expansion of Epiphany was similar to those of the other gutta-percha groups.

A study on Hospital based Home Health Care Service and the Level of Client Satisfaction (일 대학 병원의 가정간호시범사업 서비스 내용 및 만족도에 대한 조사연구)

  • Kim Chung Nam;Kwan Young Sook;Koh Hyo Jung;Kim Myung Ae;Park Chung Ja;Shin Yeong Hee;Lee Byung Sook;Lee Kyung Hee;Seo Hanng Suk
    • Journal of Korean Public Health Nursing
    • /
    • v.14 no.2
    • /
    • pp.246-259
    • /
    • 2000
  • The purpose of this study was to assess the provided home health care services and to evaluate the patient's satisfaction level of received home health care services. Well trained two home health care nurses interviewed with 138 respondents who received home health care by Keimyung University Hospital from January 1st to August 31st 1999. The results were summarized as follows : 1) Among 138 respondents, $55.8\%$ were mail and $44.2\%$ were female and $70.3\%$ of them were over sixty years old. Respondents main family care givers were spouse$(53.6\%)$, daughters and sons$(36.2\%)$ and parents$(7.2\%)$. 2) $60.2\%$ of cancer patients received home health care services, $23.3\%$ of cerebral­cardiovascular patients, $7.5\%$ of endocrine disorder patients, $2.3\%$ of those who have indwelling foley catheter patients, $1.5\%$ of those who have respiratory problems and others$(5.2\%)$. 3) $88.1\%$ of respondents were satisfied with the number of home visits they received. $50.5\%$ of respondents' were received 1 to 3 times of home visits by home health care nurse per month. $48.6\%$ of respondents answered they were introduced by attending doctors or nurses to home health care services. $55.8\%$ of respondents answered registration to home health care services was simple and easy. $97.4\%$ of respondents answered home health care payment system was adequate. $64.9\%$ of respondents answered the cost of home health care per visit was adequate and comfortable. 4) Health education, counselling, physical assessment was provided to most of the patients. Those who suffered with cerebral-cardiovascular disease was needed hands on direct care most of all. The least home health care service provided was medication. 5) The satisfaction measurement tool was composed with 13 items and 3 score scale. The mean score of satisfaction on provided home health care services was 2.67 out of 3. Among 13 items. 'home health care service was kind enough' was highest(2.84). 'nurse use precise word to understand and communicate'. 'nurse gave home visiting notice ahead of time and kept the home visiting promise on time' was 2.83. 'whenever I need home health care nurse I can give a call and meet the nurse' was lowest 2.41. Special Home Health care programs such as comprehensive hospice care programs for elders over sixty years old should be organized. Adequate and standardized home health care payment system should be developed as soon as possible. In korean family situation. when family members are getting sick and stay at home. family members were taking care of the patients. special program such as counselling family members are needed.

  • PDF