• Title/Summary/Keyword: Medical information system

Search Result 3,201, Processing Time 0.039 seconds

A Study on the Continuing Education of Dental Technicians (치과기공사의 보수교육에 관한 연구(I) -보수교육 실태와 인식을 중심으로 -)

  • Moon, Je-Hyuk
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.179-198
    • /
    • 2000
  • Since dental prosthesis is made possible only when dental technicians give themselves to the study of knowledge and the acquisition of updated skills, continuing education is of great importance in that it makes up for the efforts of dental technicians. Accordingly, continuing education relates to a system designed to contribute to the enhancement of the talents of dental technicians and the dental health of the nation. Specialized knowledge and information may work as the best weapon to preserve their jbs. This is true of this modern society where no one can expecth to survive without acquiring knowledge and information constantly for work is getting more classified and more divirsifide. This paper is dedicated to take a look at the current condition of the continuing education of dental technicians and to come up with measure to make general evaluation and to improve continuing education. This research resorts to 609 questionnaires among 6433 copies save unfaithfully responded 34 copos with 6.431 dental technicians as the subjects enrolled in the Dental technician Association. The collected questionnaires consist of 365 dental technicians living in Seoul and of 244 ones, Which account for 11.8 percent of dental technicians enrolled in the association. Because dental technicians live more in local areas than Seoul, the generalization of this survey leaves something to be desired. I have come up with the following findings. 1. 6,431 dental technicians, or 36.3 percent of an total of 14,956 licensed dental technicians, were admitted as numbers of the Dental Tachnician Association as of October 31, 1999. In the '98 continuing education. 4,141 dental technicians among 4,711 dental technicians got relevant training, and in the '99 continuing education, 4,075 technicians, or 75.9 percent of 5,365 technicians got relevant training while 1,290 technicians or 24.2 percent, fail to get relevant training. 2. The survey has it that 38.1 percent of dental technicians are ignorant of the laws on continuing education, and that technicians staying in local communities(146 persons, or 61.6%) take more part in education than those living in the capital of Korea(159 persons, or 146%), and that the older they are, the more money they earn, the more carrer they have, the higher position they hold, the more part they take in education 3. According to the survey, those who have the experience of getting training more than three times account for 52 persons(16.8%) in Seoul and 47 persons(22.4%) in local districts(p<0.01). In terms of sanctions in relation to continuing education, 26 dental technicians(4.6%) say that they have ever gotten sanctions, and 533 dental technicians(95.4%) say that they haven't. And those who were absent from continuing education(72 technicians : 13.51%) didn't get any sanction. 4. In terms of the degree of understanding continuing education, local technicians(46.8% : 110 persons) have a higher understanding of continuing education than their countparts staying in Seoul(36.0% : 130). Continuing education is not the ultimate goal itself. It should be changed to motivate those who get education to be willing to take part in contunuing education, and to help dental technicians in a practical and specific way. And the branch societies should be developde to engage in more specialized and classified expert fields. Of course, the curriculum should be so selected that the conceptions of dental technicians may be reflected to the maximum extent, and the ultimate effores should be made to effect diversity in the ways of educational methods and to perfect the preparation of continuing education on the part of instructors. Regulations should be established in relation to continuing education with a veiew to enhancing the participation of continuing education and its effectiveness. The supervision of the Ministry of Health and Welfare is of great importance in this context. The regulation of continuing education is not administrative regulation, but the expression of national will to guarantee the medical service of the nation at highest level. Therefore, it is necessary that the Ministry of Health and Welfare should change their understanding of the needs for the continuing education of dental experts, and that the expertise of government employees in charge of continuing education should be expanded. It goes without saying that the government should suppory continuing education in a financial way so as to supply the person in charge of public welfare and control the quality of national medicine.

  • PDF

Analysis of News Agenda Using Text mining and Semantic Network Analysis: Focused on COVID-19 Emotions (텍스트 마이닝과 의미 네트워크 분석을 활용한 뉴스 의제 분석: 코로나 19 관련 감정을 중심으로)

  • Yoo, So-yeon;Lim, Gyoo-gun
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.1
    • /
    • pp.47-64
    • /
    • 2021
  • The global spread of COVID-19 around the world has not only affected many parts of our daily life but also has a huge impact on many areas, including the economy and society. As the number of confirmed cases and deaths increases, medical staff and the public are said to be experiencing psychological problems such as anxiety, depression, and stress. The collective tragedy that accompanies the epidemic raises fear and anxiety, which is known to cause enormous disruptions to the behavior and psychological well-being of many. Long-term negative emotions can reduce people's immunity and destroy their physical balance, so it is essential to understand the psychological state of COVID-19. This study suggests a method of monitoring medial news reflecting current days which requires striving not only for physical but also for psychological quarantine in the prolonged COVID-19 situation. Moreover, it is presented how an easier method of analyzing social media networks applies to those cases. The aim of this study is to assist health policymakers in fast and complex decision-making processes. News plays a major role in setting the policy agenda. Among various major media, news headlines are considered important in the field of communication science as a summary of the core content that the media wants to convey to the audiences who read it. News data used in this study was easily collected using "Bigkinds" that is created by integrating big data technology. With the collected news data, keywords were classified through text mining, and the relationship between words was visualized through semantic network analysis between keywords. Using the KrKwic program, a Korean semantic network analysis tool, text mining was performed and the frequency of words was calculated to easily identify keywords. The frequency of words appearing in keywords of articles related to COVID-19 emotions was checked and visualized in word cloud 'China', 'anxiety', 'situation', 'mind', 'social', and 'health' appeared high in relation to the emotions of COVID-19. In addition, UCINET, a specialized social network analysis program, was used to analyze connection centrality and cluster analysis, and a method of visualizing a graph using Net Draw was performed. As a result of analyzing the connection centrality between each data, it was found that the most central keywords in the keyword-centric network were 'psychology', 'COVID-19', 'blue', and 'anxiety'. The network of frequency of co-occurrence among the keywords appearing in the headlines of the news was visualized as a graph. The thickness of the line on the graph is proportional to the frequency of co-occurrence, and if the frequency of two words appearing at the same time is high, it is indicated by a thick line. It can be seen that the 'COVID-blue' pair is displayed in the boldest, and the 'COVID-emotion' and 'COVID-anxiety' pairs are displayed with a relatively thick line. 'Blue' related to COVID-19 is a word that means depression, and it was confirmed that COVID-19 and depression are keywords that should be of interest now. The research methodology used in this study has the convenience of being able to quickly measure social phenomena and changes while reducing costs. In this study, by analyzing news headlines, we were able to identify people's feelings and perceptions on issues related to COVID-19 depression, and identify the main agendas to be analyzed by deriving important keywords. By presenting and visualizing the subject and important keywords related to the COVID-19 emotion at a time, medical policy managers will be able to be provided a variety of perspectives when identifying and researching the regarding phenomenon. It is expected that it can help to use it as basic data for support, treatment and service development for psychological quarantine issues related to COVID-19.

Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans (고선량률 근접치료계획의 정도보증 프로그램)

  • Han Youngyih;Chu Sung Sil;Huh Seung Jae;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.238-244
    • /
    • 2003
  • Purpose: The Planning of High-Dose-Rate (HDR) brachytherapy treatments are becoming individualized and more dependent on the treatment planning system. Therefore, computer software has been developed to perform independent point dose calculations with the integration of an isodose distribution curve display into the patient anatomy images. Meterials and Methods: As primary input data, the program takes patients'planning data including the source dwell positions, dwell times and the doses at reference points, computed by an HDR treatment planning system (TPS). Dosimetric calculations were peformed in a $10\times12\times10\;Cm^3$ grid space using the Interstitial Collaborative Working Group (ICWG) formalism and an anisotropy table for the HDR Iridium-192 source. The computed doses at the reference points were automatically compared with the relevant results of the TPS. The MR and simulation film images were then imported and the isodose distributions on the axial, sagittal and coronal planes intersecting the point selected by a user were superimposed on the imported images and then displayed. The accuracy of the software was tested in three benchmark plans peformed by Gamma-Med 12i TPS (MDS Nordion, Germany). Nine patients'plans generated by Plato (Nucletron Corporation, The Netherlands) were verified by the developed software. Results: The absolute doses computed by the developed software agreed with the commercial TPS results within an accuracy of $2.8\%$ in the benchmark plans. The isodose distribution plots showed excellent agreements with the exception of the tip legion of the source's longitudinal axis where a slight deviation was observed. In clinical plans, the secondary dose calculations had, on average, about a $3.4\%$ deviation from the TPS plans. Conclusion: The accurate validation of complicate treatment plans is possible with the developed software and the qualify of the HDR treatment plan can be improved with the isodose display integrated into the patient anatomy information.

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine (의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • INJ-I, INJ-E, PFN, BMI, and PRF were selected among the various factors which constitute a digital linear accelerator to find effects on the dose distribution by changing current and voltage within the permitted scale which Mevatron automatically maintained. We measured the absorbed dose using an ion chamber, analyzed the waveform of beam output using an oscilloscope, and measured symmetry and flatness using a dosimetry system. An RFA plus (Scanditronix, Sweden) device was used as a dosimetry system. Then an 0.6cc ion chamber (PR06C, USA), an electrometer (Capintec192, USA), and an oscilloscope (Tektronix, USA) were employed to measure the changes on the dose distribution characteristics by changing the beam-tuning parameters. When the currents and the voltages of INJ-I, INJ-E, PFN, BMI, and PRF were modified, we were able to see the notable change on the dose rate by examining the change of the output pulse using the oscilloscope and by measuring them using the ion chamber. However, the results of energy and flatness graph from RF A plus were almost identical. The factors had fine differences: INJ-I, INJ-E, PFN, BMI, and PRF had 0.01∼0.02% differences in D10/D20, 0.1∼0.2 % differences in symmetry, and 0.1∼0.4% differences in flatness. Since Mevatron controlled itself automatically to keep the reference value of the factor, it was not able to see large differences in the dose distribution. There were fine differences on the dose rate distribution when the voltage and the currents of the digitized factors were modified Nonetheless, a basic operational management information was achieved.

  • PDF

Understanding the Legal Structure of German Human Gene Testing Act (GenDG) (독일 유전자검사법의 규율 구조 이해 - 의료 목적 유전자검사의 문제를 중심으로 -)

  • Kim, Na-Kyoung
    • The Korean Society of Law and Medicine
    • /
    • v.17 no.2
    • /
    • pp.85-124
    • /
    • 2016
  • The Human gene testing act (GenDG) in Germany starts from the characteristic features of gene testing, i.e. dualisting structure consisted of anlaysis on the one side and the interpretation on the other side. The linguistic distincion of 'testing', 'anlaysis' and 'judgment' in the act is a fine example. Another important basis of the regulation is the ideological purpose of the law, that is information autonomy. The normative texts as such and the founding principle are the basis of the classification of testing types. Especially in the case of gene testing for medical purpose is classified into testing for diagnostic purpose and predictive purpose. However, those two types are not always clearly differentiated because the predictive value of testing is common in both types. In the legal regulation of gene testing it is therefore important to manage the uncertainty and subjectivity which are inherent in the gene-analysis and the judgment. In GenDG the system ensuring the quality of analysis is set up and GEKO(Commity for gene tisting) based on the section 23 of GenDG concretes the criterium of validity through guidelines. It is also very important in the case of gene testing for medical purpose to set up the system for ensurement of procedural rationality of the interpretation. The interpretation of the results of analysis has a wide spectrum because of the consistent development of technology on the one side and different understandings of different subjects who performs gene testings. Therefore the process should include the communication process for patients in oder that he or she could understand the meaning of gene testing and make plans of life. In GenDG the process of genetic counselling and GEKO concretes the regulation very precisely. The regulation as such in GenDG seems to be very suggestive to Korean legal polic concerning the gene testing.

  • PDF

The Characteristic of Research Regulation in Recent Japanese Medical World (최근 일본의 의학계 연구규율의 특색)

  • Song, Young-mi
    • The Korean Society of Law and Medicine
    • /
    • v.20 no.2
    • /
    • pp.173-206
    • /
    • 2019
  • This research examines the characteristic of regulation on Japanese clinical research in recent years. First, Japan has had a severe punishment policy on research misconduct like Korea, but, in recent days, Japan has changed the direction of research ethics policy from restriction to research publicness securement by educational training, in addition, Act of Clinical Research, effected April 2018, has recruited excellent researchers, and then integrated clinical research and medicine clinical trial through raising transparency of funding and integrating ethics screening by mandating announcement on funding information of clinical research. Second, Japan has integrated and organized ethics guideline from dual system that consists of ethics guideline on dynamic research(here after, referred to as 「dynamic guideline」) and ethics guideline on clinical research(here after, referred to as 「clinical guideline」) to ethics guideline on medical research aimed at human(here after, referred to as 「integrated guideline」), thus, it complements repetition and deficit of ethics guideline needed in clinical research and dynamic research, and it has risk evaluation system for protecting human subjects, and also it clarifies the concept of 「invasiveness」, a preliminary consideration of evaluation. 「Evaluation issue of risk and profit」, common contents of international regulation related clinical research, is the method to check whether the research is designed appropriately or not, this is the method for Institutional Review Board to decide whether the risk on human subjects could be justified, and also this is the important standard for future human subjects to participate in clinical trial. Therefore, it is meaningful to define 「invasiveness」 concept, a preliminary consideration of risk evaluation for human subjects. This research examines Japanese clinical trial focusing on change of awareness on prevention of research misconduct, efficiency improvement of research through research screening and integration of human subjects, and clarification and extension of range of 「invasiveness」 concept, a preliminary of risk evaluation to protect human subjects.

Evaluation of Metabolic Abnormality in Brain Tumors by In Viuo $^1$H MR Spectroscopy at 3 Tesla (3T 양성자 자기공명분광에 의한 뇌종양의 대사물질 이상소견)

  • Choe, Bo-Young;Jeun, Sin-Soo;Kim, Bum-Soo;Lee, Jae-Mun;Chung, Sung-Taek;Ahn, Chang-Beom;Oh, Chang-Hyun;Kim, Sun I.;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.120-128
    • /
    • 2002
  • To investigate differences between the metabolic ratios of normal controls and brain tumors such as astrocytomas and glioblastoma multiforme (GM) by proton MR spectroscopy (MRS) at 37 high field system. Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67$\pm$018 and 1.16$\pm$0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (P=0.005). Cho/Cr ratio of glioblastoma multiforme was significantly higher than that of astrocytomas (P=0.001). Lactate was observed in all tumor cases. The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. This results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy.

  • PDF