• Title/Summary/Keyword: Medical imaging equipment

Search Result 148, Processing Time 0.024 seconds

Laparoscopic Splenectomy in Two Dogs Using SonicisionTM

  • Park, Tae-Yeong;Kim, Hyun-Jin;Kim, Jung-Hoon;Kim, Jun-Min;Seok, Seong-Hoon;Jung, Dong-In;Hong, Il-Hwa;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.33 no.4
    • /
    • pp.214-217
    • /
    • 2016
  • A 10-year-old, 24.1 kg, intact female Siberian husky dog (case 1) and 11-year-old, 5.0 kg, intact male Shihtzu dog (case 2) presented with chief complaints of polydipsia, anorexia, vomiting and exercise intolerance (case 1) and stranguria (case 2). Splenic nodule (case 1) and mass (case 2) were identified in these patients through ultrasonographic examination. Laparoscopic splenectomy was conducted for the histopathologic evaluation. In addition, laparoscopic ovariohysterectomy, liver biopsy (case 1) and castration (case 2) were performed for treatment or diagnosis of primary symptoms. Under general anesthesia, 5 mm three-portal access laparoscopic splenectomy was performed using the Sonicision$^{TM}$ equipment. The dogs were rotated onto right lateral recumbency. The spleen was elevated using a fan or goldfinger retractor, which revealed the ventral aspect of the spleen. Resection of vessels was started at the caudal aspect of the spleen using the Sonicision$^{TM}$. The excised spleen was removed from the abdominal cavity using a 12 mm endo-bag via the enlarged instrument portal. There were no post-operative complications in either patient. Histopathologic diagnoses were splenic lymphoid hyperplasia (case 1) and splenic nodular hyperplasia (case 2). Based on our experience, laparoscopic splenectomy is sufficient to replace traditional splenectomy in small animal surgery. The use of the Sonicision$^{TM}$ could be a novel surgical technique for three-portal laparoscopic splenectomy, regardless of patient size.

Comparison of Image Quality in Magnetic Resonance Imaging of the Abdominal Organ at 1.5T and 3.0T before the Gadolinium Injection (조영제 주입 전 1.5T 와 3.0T를 이용한 복부장기 자기공명영상에서 영상의 질 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.619-625
    • /
    • 2017
  • The sudy was intended to evaluate the optimal equipment selection by quantitatively assessing the SNR(signal to noise ratio) and CNR(contrast to noise ratio) on the abdominal organ. This study performed on 1.5 T and 3.0 T MRI units focusing on HASTE, HASTE(f/s) and FFE(in of phase), FFE(out of phase) without using the contrast medium(Gadolinium). The data analysis was performed by randomly selecting on 1.5 T and 3.0 T abdominal MRI images. As a results, SNR and CNR values of 3.0 T is higher than 1.5 T at liver, kidney and spleen(p<0.05). Stomach, abdominal fat and pancreas was obtained a higher value at 1.5 T(p<0.05). On conclusion, the organs of outer part in the body showed generally a high value at 3.0 T, and the organs of inner part in the body including the gas showed a high value at 3.0 T because of a large difference on magnetic susceptibility.

A Study on Visuospatial Cognitive Performance Following Oxygen Administration using fMRI (뇌기능 영상을 이용한 외부 산소 공급에 따른 공간 지각 능력 변화에 관한 연구)

  • 정순철;김익현;이봉수;이정미;손진훈;김승철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.267-273
    • /
    • 2003
  • The present study attempted to observe what changes the supply of highly concentrated (30%) oxygen cause to people's ability of visuospatial cognition, compared to air of normal oxygen concentration (21%). This study sampled eight male university students (the average age : 23.5) as subjects for functional Magnetic Resonance Imaging (MRI) study It also developed equipment that supplies 21% and 30% oxygen) at a constant rate of 8L/min. Two questionnaires containing 20 questions were developed to measure the ability of visuospatial cognition, and accuracy was calculated from the result of task performance. The experiment paradigm consisted of the run conducting tasks at 30%'s concentration of oxygen and another run at 21%'s concentration of oxygen. Each run was composed of four blocks and each block included eight control tasks and five visuospatial taks. 3T MRI was used and fMRI was obtained through the single-shot EPI method. The activation in the occipital-associated area, bilateral superior parietal lobes, bilateral inferior parietal lobes. bilateral precuneus, bilateral postcentral gyri, bilateral middle frontal gyri, bilateral inferior frontal gyri, bilateral medial frontal gyri, bilateral superior frontal gyri, bilateral cingulate gyri was significantly increased at the 30%'s concentration of oxygen rather than 21%'s. Furthermore, the result of task performance showed the accuracy increased at 30%'s concentration of oxygen rather than 21%'s. From the result of this study, it is concluded that the supply of highly concentrated oxygen has a positive effect on the ability of visuospatial cognition.

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

Development of a Model for MR-CT Bi-directional Conversion based on scCycleGAN (scCycleGAN 기반 MR-CT 상호 변환 모델의 구축)

  • Da-Um Jeong;Seung-Jin Park;Seung-Yeon Shin;Yong-Ah Lee;Seong-Bin Jang;Jong-Cheon Lim;Joo-Wan Hong;Dong-Kyoon Han
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.6
    • /
    • pp.715-724
    • /
    • 2024
  • We aimed to build an MR-CT interconversion model based on structure-constraints Cycle-constraints Generative Adversarial Neural Networks (scCycleGANs). We used MDCT (Somatom Definition Flash CT, SIEMENS, Germany) and 3.0T MRI (Ingenia 3.0T CX MRI, PHILIPS, Netherlands) as our hardware equipment and Python (3.12.6) and PyTorch (2.4.0) as software. The study model was scCycleGAN. We acquired 2,871 and 2,436 brain CT and MR (T2WI) images of 87 patients, respectively, and for a total of 5,307 medical images, CT and MR images taken at the same level were classified through primary evaluation, and 364, 27, and 8 pairs of images were labeled as training, validation, and test data, respectively. Then, we applied hybrid objective function to the GAN model based on the basic APS frameworks to build the model, and the evaluation of the generated model was divided into quantitative and qualitative evaluation. The qualitative evaluation was conducted on 10 radiologists with more than 20 years of experience, and the quantitative evaluation was set as PSNR, IOU, SSIM, and MAE. The results of the qualitative evaluation showed that the percentage of 'positive responses', defined as a response of 'Neutral' or better, was 63% and 96% for the Synthesis CT (sCT) and Synthesis MR (sMR) groups, respectively, while the quantitative evaluation metrics PSNR, SSIM, and MAE achieved the initial target values for both groups. Our study can be used as basic guided research in the field of medical image conversion and synthesis. And further research and complementary studies are expected to solve problems such as model lightweighting to reduce the dose burden on patients and medical costs if applied to clinical environments.

Analysis of $^1H$ MR Spectroscopy of parietal white matter material Phantom (두정부 백질 물질을 이용한 수소 자기 공명 분광 분석)

  • Lee, Jae-Yeong;Lim, Cheong-Hwan;Kim, Myeong-Soo
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.57-61
    • /
    • 2003
  • The purpose of this study is to compare both 1.5T and 4.7T in Praietal White matter material Phantom using the same methodology at both field strengths. Data at both field strengths are compared in terms of $T_2$ relaxation times, line widths and SNRs MR imaging and $^1H$ MR spectroscopy were performed on GE 1.5T SIGNA system and Broker Biospec 4.7T/30 MRI/MRS system. After phantom axial scan $^1H$ MRS was obtained from T2 weighted image by 3-dimensional localization technique(PRESS : Point RE solved spectroscopy Sequence) this phantom is composed of an aqueous solution 36.7 mmol/L of NAA, 25.0 mmol/L of Cr, 6.3 mmol/L of choline chloride, 30.0 mmol/L or Glu, and 22.5 mmol/L of MI(adjusted to a pH of 7,15 in a phosphate buffet). Data processed using software developed inhouse. At 1.5T, T2 relaxation times for Cho, Cr, and NAA were $0.41{\pm}0.07,\;0.26{\pm}0.04,\;0.46{\pm}0.07$ while at 4.7T they were $0.17{\pm}0.03,\;0.14{\pm}0.05,\;0.20{\pm}0.03$ respectively. At 1.5T, line widths for water, Cho, Cr and NAA were $2.9{\pm}0.7,\;1.6{\pm}0.7,\;1.7{\pm}0.8,\;2.2{\pm}0.02Hz$ while at 4.7T they were $5.2{\pm}1.1,\;4.6{\pm}1.9,\;4.01{\pm}1.8,\;4.8{\pm}1.9Hz$ respectively. It can be seen that $T_2$ relaxation times were significantly shorter at 4.7 compared to 1.5T and that the line widths were also broader. The average SNRs for NAA for subjects at short and long TEs were $23.5{\pm}11.3$ at TE=20 msec ; $15.4{\pm}7.7$ at TE=272 msec at 1.5T and $40{\pm}8.3$ and $17{\pm}3.5$ respectively at 4.7T higher field strength is superior because of improved sensitivity and chemical shift dispersion. However these improvements are partially offset by increased line widths and decrease $T_2$ relaxation times, which act to reduce both sensitivity and resolution. In our experiments with the equipment available to us, 4.7T proton spectra at short TEs exhibit moderately improved sensitivity compared to 1.5T.

  • PDF

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF