• 제목/요약/키워드: Medical image analysis

검색결과 917건 처리시간 0.037초

Application of spectral image - Present and Promise -

  • Miyake, Yoichi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1158-1159
    • /
    • 2009
  • Tri-stimulus values of CIE-XYZ and RGB values obtained by photographic film, CCD camera or scanner depend on the spectral sensitivity of imaging devices and the spectral radiant distribution of the illumination. It is important to record and reproduce the reflectance spectra of the object for true device independent color reproduction and high accurate recording of the scene. In this paper, a method to record the reflection spectra of the object is introduced and its application to spectral endoscopes is presented.

  • PDF

챔퍼 매칭(Chamfer Matching) 알고리즘을 활용한 모의치료 영상과 포탈(Portal) 영상의 비교, 분석 (The Application of Chamfer Matching Algorithm to the Error Analysis of a Treatment Field between a Simulation Image and a Portal Image)

  • 송주영;나병식;정웅기;안성자;남택근;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.189-195
    • /
    • 2003
  • 방사선 치료시 치료계획과 실제 치료가 정확히 일치하고 있는 지를 확인하기 위해 수행하는 모의치료 영상과 포탈 영상과의 비교, 분석은 방사선 치료의 정확도를 보장하기 위한 중요한 과정이다. 본 연구에서는 이와 같은 모의치료 영상과 포탈 영상의 비교 및 오차의 정량적 분석을 위해 영상정합 방법의 하나인 챔퍼 매칭 알고리즘을 적용한 분석 프로그램을 개발하여 그 정확성과 타당성을 분석하였다. 가상의 포탈 영상을 사용하여 분석 알고리즘의 정확도를 분석한 결과, 이동에서 평균 0.64 mm, 회전에서 평균 0.32 $^{\circ}$, 스케일에서 평균 1.61% 이내의 오차를 보여 그 정확성을 입증하였고, 인체 모사 팬텀을 대상으로 한 실제 포탈 영상에서도 이동에서 평균 1.55 mm, 회전에서 평균 0.80 $^{\circ}$, 스케일에서 1.72% 이내의 오차를 보여, 본 연구에서 개발한 분석 프로그램의 타당성을 검증하였다. 본 연구를 통해 모의치료 영상과 포탈 영상의 비교, 분석에 있어 챔퍼 매칭 알고리즘을 적용할 수 있음을 확인하였으며, 개발한 분석 프로그램은 필름을 기반으로 한 모의치료 영상과 포탈 영상의 비교와 오차의 정량적 분석에 효율적으로 사용 될 수 있을 것으로 사료된다.

  • PDF

Magnetic Resonance Image Manifestations of the Atypical Meningioma

  • Wu, Qing-Wu;Yan, Rui-Fang;Li, Qiang;Hu, Ying;Zhou, Feng-Mei;Ren, Ji-Peng;Yang, Rui-Min;Zhang, Yan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권11호
    • /
    • pp.6337-6340
    • /
    • 2013
  • Through retrospective analysis of 13 cases of magnetic resonance image (MRI) manifestations of atypical meningiomas confirmed by operation and pathology in the First Affiliated Hospital of Xinxiang Medical University, the objective of this study was to evaluate the diagnostic value of MRI in order to improve the accuracy rate of preoperative diagnosis. In this retrospective analysis of MRI findings for atypical meningiomas in First Affiliated Hospital of Xinxiang Medical University from January to July in 2012, the location, morphology and tumor signals and other tumor imaging characteristics were covered. In 13 cases of atypical meningioma patients of this group, most tumors were located at typical sites (10/13), mainly the falx cerebri, parasagittal, convexity, saddle area. Only two cases were at atypical locations, 1 in the cerebellar hemisphere and 1 in a lateral ventricle. Most of the tumors showed T1 and T2 isointensity signals, and necrosis, calcification, and peritumoral edema were always featured. DWI showed isointensity in 11 cases (11/13), and hyperintensity in 2. Some 9 cases had dural tail signs, 12 had accurate positioning (12/13), and 2 were postoperative recurrences. MRI has high value in the diagnosis of atypical meningiomas, with important roles in early clinical diagnosis, treatment and prognosis evaluation.

게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가 (The Evaluation of Clinical Usefulness on Application of Half-Time Acquisition Factor in Gated Cardiac Blood Pool Scan)

  • 이동훈;유희재;이종훈;정우영
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.192-198
    • /
    • 2008
  • Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.

  • PDF

객체 중심 계층적 계획을 이용한 뇌경색 환자의 시기별 MRI 정량적 분석에 관한 연구 (MRI Quantification Analysis on Fall in Sick Times of the Cerebral Infarction Patients Using Object-Centered Hierarchical Planning)

  • 하광;전계록;김길중
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권2호
    • /
    • pp.61-68
    • /
    • 2003
  • 본 논문에서는 의학적 진단 및 처치 방법의 결정에 중요한 역할을 하는 뇌경색 환자의 각 시기별 특징을 정량화하기 위해 3 가지 MRI 촬영기법을 이용하여 획득한 영상의 특징과 그들의 상관관계들을 객체중심 계층적계획기법을 이용하여 분석하였다. 3 가지 영상의 비교를 위하여 다항워핑 알고리즘과 어파인 변환기법을 수행하여 영상을 정합하였으며, 정합된 영상을 기반으로 뇌경색 시기별 정량화를 수행하였다. 그리고 각 시기별로 색을 설정하여 수 작업으로 얻어진 데이터를 바탕으로 의사 컬러로 나타내었다. 본 연구에서 구한 뇌경색 시기별 정량화 자료를 바탕으로 구분된 결과와 전문의가 판단한 결과를 비교하였다.

복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구 (A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries)

  • 장지성;최원근;정재연;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

Cycle-Consistent Generative Adversarial Network: Effect on Radiation Dose Reduction and Image Quality Improvement in Ultralow-Dose CT for Evaluation of Pulmonary Tuberculosis

  • Chenggong Yan;Jie Lin;Haixia Li;Jun Xu;Tianjing Zhang;Hao Chen;Henry C. Woodruff;Guangyao Wu;Siqi Zhang;Yikai Xu;Philippe Lambin
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.983-993
    • /
    • 2021
  • Objective: To investigate the image quality of ultralow-dose CT (ULDCT) of the chest reconstructed using a cycle-consistent generative adversarial network (CycleGAN)-based deep learning method in the evaluation of pulmonary tuberculosis. Materials and Methods: Between June 2019 and November 2019, 103 patients (mean age, 40.8 ± 13.6 years; 61 men and 42 women) with pulmonary tuberculosis were prospectively enrolled to undergo standard-dose CT (120 kVp with automated exposure control), followed immediately by ULDCT (80 kVp and 10 mAs). The images of the two successive scans were used to train the CycleGAN framework for image-to-image translation. The denoising efficacy of the CycleGAN algorithm was compared with that of hybrid and model-based iterative reconstruction. Repeated-measures analysis of variance and Wilcoxon signed-rank test were performed to compare the objective measurements and the subjective image quality scores, respectively. Results: With the optimized CycleGAN denoising model, using the ULDCT images as input, the peak signal-to-noise ratio and structural similarity index improved by 2.0 dB and 0.21, respectively. The CycleGAN-generated denoised ULDCT images typically provided satisfactory image quality for optimal visibility of anatomic structures and pathological findings, with a lower level of image noise (mean ± standard deviation [SD], 19.5 ± 3.0 Hounsfield unit [HU]) than that of the hybrid (66.3 ± 10.5 HU, p < 0.001) and a similar noise level to model-based iterative reconstruction (19.6 ± 2.6 HU, p > 0.908). The CycleGAN-generated images showed the highest contrast-to-noise ratios for the pulmonary lesions, followed by the model-based and hybrid iterative reconstruction. The mean effective radiation dose of ULDCT was 0.12 mSv with a mean 93.9% reduction compared to standard-dose CT. Conclusion: The optimized CycleGAN technique may allow the synthesis of diagnostically acceptable images from ULDCT of the chest for the evaluation of pulmonary tuberculosis.

전산화단층촬영장비 정도관리의 적정 인지도에 관한 연구 (A Study on the Adequacy Awareness of Computed Tomography Equipment Quality Control)

  • 김규형;임청환;김기정
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권1호
    • /
    • pp.31-37
    • /
    • 2019
  • Investigate the adequacy awareness of accuracy control of CT apparatus Questionnaire survey and statistical analysis in the analysis according to age, there is a difference between familiarity with accuracy management items (F = 14.187, p<0.001) and necessity of accuracy control (F=8.109, p<0.001), depending on academic background and work history, There is a difference only in familiarity (F=5.103, p<0.05, F=13.394, p<0.001), and according to the scale of the medical institution analysis shows that if you are more interested than senior general hospital grade hospital grade or less It was analyzed. In order to advance the accuracy control level, we have introduced our comprehensive and efficient comprehensive and efficient integrated medical image quality management operation system of the whole medical image equipment including CT device, It is thought that it is necessary to develop human resources capable of doing.

일부 성인의 치과위생사에 대한 전문직업인 이미지 관련요인 (Factors affecting the professional image of dental hygienists)

  • 최혜정;박경화
    • 한국치위생학회지
    • /
    • 제20권2호
    • /
    • pp.197-207
    • /
    • 2020
  • Objectives: To provide basic information for improving the professional image of the dental hygienist among adults who visit the dentist. Methods: From December 5, 2018 to January 25, 2019, 214 adults in Seoul or Gyeonggi filled out a Google online questionnaire. Data were analyzed using t-test, one-way analysis of variance (ANOVA), and multiple regression analysis. Results: The overall average score of the professional image of dental hygienists was 3.59. In addition, there were significant differences in the image according to age, education, and occupation. The image according to the dental visit experience was highest for those providing orthodontic treatment. The difference in professional image recognized by the dental hygienists and the patients was highest in the case of those dental hygienists responding that they had been educated at a four-year university, who were considered as medical practitioners, and were called a dental hygienist. Lastly, the factors related to the professional image of the dental hygienist were positively affected in the case of preventive purpose of visit, and graduate or higher education of the patients. Conclusions: In order to establish the professional image of dental hygienists, public relations for adequate occupational awareness of their work should be continued. Additionally, it is necessary to establish the role through the systematic expansion of the professional image and their being considered as medical professionals, reflecting the reality of the work field.

Prognostication of Hepatocellular Carcinoma Using Artificial Intelligence

  • Subin Heo;Hyo Jung Park;Seung Soo Lee
    • Korean Journal of Radiology
    • /
    • 제25권6호
    • /
    • pp.550-558
    • /
    • 2024
  • Hepatocellular carcinoma (HCC) is a biologically heterogeneous tumor characterized by varying degrees of aggressiveness. The current treatment strategy for HCC is predominantly determined by the overall tumor burden, and does not address the diverse prognoses of patients with HCC owing to its heterogeneity. Therefore, the prognostication of HCC using imaging data is crucial for optimizing patient management. Although some radiologic features have been demonstrated to be indicative of the biologic behavior of HCC, traditional radiologic methods for HCC prognostication are based on visually-assessed prognostic findings, and are limited by subjectivity and inter-observer variability. Consequently, artificial intelligence has emerged as a promising method for image-based prognostication of HCC. Unlike traditional radiologic image analysis, artificial intelligence based on radiomics or deep learning utilizes numerous image-derived quantitative features, potentially offering an objective, detailed, and comprehensive analysis of the tumor phenotypes. Artificial intelligence, particularly radiomics has displayed potential in a variety of applications, including the prediction of microvascular invasion, recurrence risk after locoregional treatment, and response to systemic therapy. This review highlights the potential value of artificial intelligence in the prognostication of HCC as well as its limitations and future prospects.