• Title/Summary/Keyword: Medical exposure

Search Result 1,944, Processing Time 0.028 seconds

The analysis of the relation between noise induced hearing loss and noise exposure (소음유발 청력손실과 소음폭로에 대한 연구)

  • 장호경
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.217-225
    • /
    • 1998
  • In this paper, the analysis of the relation between noise induced hearing loss and noise exposure is described for the A-weighted noise levels and exposure duration. The hearing loss and sensitivity threshold shift is investigated by changing the various parameters such as the effects of aging and noise exposure. Total hearing loss is proportional to a function of exposure level based upon the integral of pressure with time. If the noise exposure term is large so that the presbycusis may be neglected, the hearing loss due to aging and noise exposure becomes the noise induced hearing loss. It is shown that exposure to excessive noise can cause temporary loss of hearing that may become permanent if the exposure is prolonged or intense. An audiogram taken from a person suffering from noise induced hearing loss will usually show the greatest loss of hearing sensitivity in the 4kHz region, which is typically the region most sensitive to damage resulting from many types of industrial noise.

  • PDF

Influence of the Vibration Exposure on Shoulder and Back Extensor Muscles Activity During Forward-head and Over-head Task

  • Cheon-jun Park;Duk-hyun An;Jae-seop Oh;Won-gyu Yoo
    • Physical Therapy Korea
    • /
    • v.30 no.1
    • /
    • pp.23-31
    • /
    • 2023
  • Background: Several factors contribute to shoulder pain, including abnormal neck posture, repeated use of the upper limbs, work involving raising the upper limbs above the head, and the effects of vibration. However, previous study has reported that constant vibration exposure could impact improvement of the stability on joints related with muscle recruitment and activation. For this difference reason, we need to verify for the complex study of relationship with repetitive upper limb movements, poor head posture, and constant vibration exposure. Objects: Our study was made to investigate the influence of vibration exposure on the shoulder muscle activity during forward-head and over-head tasks with isometric shoulder flexion. Methods: In a total of 22 healthy subjects, surface electromyography (EMG) data were collected from shoulder muscles (upper/lower trapezius, serratus anterior, and lumbar erector spinae) on tasks (neutral-head task [NHT], forward-head task [FHT], and over-head task [OHT]) with and without vibration exposure. Results: In all tasks, the EMG data of the upper trapezius and serratus anterior significantly increased with vibration exposure (p < 0.05). Furthermore, the EMG data of the lumbar erector spinae significantly increased with vibration exposure in the NHT and FHT (p < 0.05). Conclusion: We suggest that continuous vibration exposure during the use of hand-held tools in the tasks could be associated with harmful effects in the workplace. Lastly, we clinically need to examine the guidelines regarding the optimal posture and vibration exposure.

The Study on the Image Quality and Patient Exposure Dose of Chest Radiography in Korea (흉부촬영시 피폭선량과 화질에 관한 조사연구)

  • Lee, Sun-Sook;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.18 no.2
    • /
    • pp.49-59
    • /
    • 1995
  • Recently, general radiography became to variety because of the continuous development of Inverter type generator and ortho chromatic system. Therefore, we must re-evaluate about patient exposure dose and image quality. I studied about chest radiography which has frequency among general radiography being used during FEB. to AUG., 1994 over 151 medical facilities from medical facilities that are located in Seoul area. The result obtained were as follows ; 1) The rectification method of the generator were employing mainly single phase full wave in 82.8 %, three phase full wave in 11.26 % and Inverter type in 4.64 % and condenser type is 1.32 %. 2) Exposure kV was used below 80 kV in most medical facilities and 21.8 % of the medical facilities was using high tube voltage higher than 120 kV. 3) The exposure time was used below the 0.05 sec in 28.4 %, in 29.8 % of the medical facilities used above 0.1 sec. 4) The usage frequency of the added filter is 15.3 %, and among them compound filter was used only 4 %. 5) Rare earth screen was used in 37.7 %. 6) The average skin entrance dose was 0.25 mSv, the range of dose is $0.05{\sim}0.79\;mSv$ in each medical facilities. 7) The average density of the lung field is 1.76, 0.49 in lung side, 0.30 in mediastinum and 0.37 in heart shadow. Therefore it is required to improve all of these for increasing image quality and reducing patient exposure dose as soon as possible.

  • PDF

Assessment of Chemical Risks in Moroccan Medical Biology Laboratories in Accordance with the CLP Regulation

  • Mourry, Ghita E.;Alami, Rachid;Elyadini, Adil;Hajjaji, Souad El;kabba, Saad El;Zouhdi, Mimoun
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.193-198
    • /
    • 2020
  • Background: Medical laboratory workers are frequently exposed to a wide range of chemicals. This exposure can have adverse effects on their health. Furthermore, a knowledge lack of the chemical risk increases the likelihood of exposure. The chemical risk assessment reduces the risk of exposure to hazardous chemicals and therefore, guarantees health and safety of the workers. Method: The chemical risk assessment was conducted using a modified INRS method, according to the new CLP Regulation, of 11 unit laboratories in a Moroccan medical laboratory. Observation of each workstation and analysis of safety data sheets are key tools in this study. Results: A total of 144 substances and reagents that could affect the health of the analytical technicians were identified. Among these products, 17% are concerned by the low priority risk score, with 55% concerned by the average priority risk score and 28% concerned by the high priority risk score. This study also enabled to better identify the chemical agents that have restrictive occupational exposure limit value and controls were conducted to this effect. On the basis of the results obtained, several corrective and preventive measures have been proposed and implemented. Conclusion: Risk assessment is essential to ensure the health and safety of workers and to meet regulatory requirements. It enables to identify all the risky manipulations and to adopt appropriate preventive measures. However, it is not a one-time activity but it must be continuous in order to master the changes and thus ensure the best safety of all.

Radiation Dose Distribution of a Surgeon and Medical Staff during Orthopedic Balloon Kyphoplasty in Japan

  • Ono, Koji;Kumasawa, Takafumi;Shimatani, Keiichi;Kanou, Masatoshi;Yamaguchi, Ichiro;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.86-92
    • /
    • 2022
  • Background: The present study investigated the radiation dose distribution of balloon kyphoplasty (BKP) among surgeons and medical staff, and this is the first research to observe such exposure in Japan. Materials and Methods: The study subjects were an orthopedic surgeon (n = 1) and surgical staff (n = 9) who intervened in BKP surgery performed at the National Hospital Organization Disaster Medical Center (Tokyo, Japan) between March 2019 and October 2019. Only disposable protective gloves (0.022 mmPb equivalent thickness or less) and trunk protectors were used, and no protective glasses or thyroid drapes were used. Results and Discussion: The surgery time per vertebral body was 36.2 minutes, and the fluoroscopic time was 6.8 minutes. The average exposure dose per vertebral body was 1.46 mSv for the finger (70 ㎛ dose equivalent), 0.24 mSv for the lens of the eye (3 mm dose equivalent), 0.11 mSv for the neck (10 mm dose equivalent), and 0.03 mSv for the chest (10 mm dose equivalent) under the protective suit.The estimated cumulative radiation exposure dose of 23 cases of BKP was calculated to be 50.37 mSv for the fingers, 8.27 mSv for the lens, 3.91 mSv for the neck, and 1.15 mSv for the chest. Conclusion: It is important to know the exposure dose of orthopedic surgeons, implement measures for exposure reduction, and verify the safety of daily use of radiation during surgery and examination.

Dermal Exposure Associated with Occupational End Use of Pesticides and the Role of Protective Measures

  • MacFarlane, Ewan;Carey, Renee;Keegel, Tessa;El-Zaemay, Sonia;Fritschi, Lin
    • Safety and Health at Work
    • /
    • v.4 no.3
    • /
    • pp.136-141
    • /
    • 2013
  • Background: Occupational end users of pesticides may experience bodily absorption of the pesticide products they use, risking possible health effects. The purpose of this paper is to provide a guide for researchers, practitioners, and policy makers working in the field of agricultural health or other areas where occupational end use of pesticides and exposure issues are of interest. Methods: This paper characterizes the health effects of pesticide exposure, jobs associated with pesticide use, pesticide-related tasks, absorption of pesticides through the skin, and the use of personal protective equipment (PPE) for reducing exposure. Conclusions: Although international and national efforts to reduce pesticide exposure through regulatory means should continue, it is difficult in the agricultural sector to implement engineering or system controls. It is clear that use of PPE does reduce dermal pesticide exposure but compliance among the majority of occupationally exposed pesticide end users appears to be poor. More research is needed on higher-order controls to reduce pesticide exposure and to understand the reasons for poor compliance with PPE and identify effective training methods.

Analysis of Copper, Zinc in Serum Using ICP-MS & AAS (ICP-MS와 AAS를 이용한 체내 혈청 Cu, Zn 분석에 관한 연구)

  • Lee, Yea-Jin;Kim, Dong-Yub;Lee, Go-Eun;Jo, Young-Suk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The exposure of human beings to toxic trace metals (Cu, Zn) continues to be an important public health issue and concern. This study was conducted to assess the exposure to trace metals (Cu, Zn) in the general Korean population by inductively coupled plasma mass spectrometry (ICP-MS) and Atomic absorption spectrometry (AAS). Serum samples were obtained from 40 healthy volunteers. Specimens were collected in special container and we applied sample processing to minimize contamination. We used ICP-MS and AAS to analyze simultaneously the concentration of metals including copper, zinc. Distribution of trace metal levels in the general healthy population showed lower values. The results in this study can provide background data for clinical studies associated with trace metal exposure in the korean population.

  • PDF

Blue light Exposure Control System Using Sensor Modules

  • Lim, Myung-Jae;Jung, Dong-Kun;Kim, Kyu-Dong;Kwon, Young-Man
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.315-319
    • /
    • 2021
  • Recent impact of 4th industrial revolution is increasing usage of IoT technology along with smartphones and tablet PC. However blue light emitted from electronic devices such as smartphones and tablet PC causes detrimental change to human bodies. As the controversy over the harmfulness of blue light became known through the media and various communities, related markets were formed, and various blocking films, software, and vision protection monitors were released. In this paper focuses on utilizing IoT technology to protect human organizations from blue light. It presents anti-blue light system which prevents excessive exposure to blue light through Arduino module such as ultrasound, piezo buzzer and blue light measurement module.

Therapeutic Effects and Adverse Drug Reactions are Affected by Icotinib Exposure and CYP2C19 and EGFR Genotypes in Chinese Non-Small Cell Lung Cancer Patients

  • Chen, Jia;Zheng, Xin;Liu, Dong-Yang;Zhao, Qian;Wu, Yi-Wen;Tan, Fen-Lai;Wang, Yin-Xiang;Jiang, Ji;Hu, Pei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7195-7200
    • /
    • 2014
  • Background: The aim of this study was to evaluate how CYP2C19 affects icotinib and metabolite' exposure, and to determine whether the exposure and EGFR genotype influences survival time, tumor metastasis and adverse drug reactions. Materials and Methods: 274 NSCLC patients who accepted 125mg icotinib/t.i.d. were chosen from a phase III study. Blood samples were obtained in $672^{nd}$ ($4^{th}$ week) and $1,680^{th}$ hours ($10^{th}$ week), and plasma was used to quantify the concentration of icotinib and blood cells were sampled to check the genotypes. Clinical data were also collected at the same time, including EGFR genotypes. Plasma concentrations were assessed by HPLC-MS/MS and genotype by sequencing. All data were analyzed through SPSS 17.0 and SAS 9.2. Results: CYP 2C19 genotypes affected bio-transformation from icotinib to M24 and M26, especially in poor-metabolisers. Higher icotinib concentrations (>1000 ng/mL) not only increased patient PFS and OS but also reduced tumor metastasis. Patients with mutant EGFR experienced a higher median PFS and OS (234 and 627 days), especially those with the 19del genotype demonstrating higher PR ratio. Patients who suffered grade II skin toxicity had a higher icotinib exposure than those with grade I skin toxicity or no adverse effects. Liver toxic reactions might occur in patients with greater M20 and M23 plasma concentrations. Conclusions: CYP2C19 polymorphisms significantly affect icotinib, M24 and M26 exposure. Patients with mutant EGFR genotype and higher icotinib concentration might have increased PFS and OS and lower tumor metastasis. Liver ADR events and serious skin effects might be respectively induced by greater M20, M23 and icotinib concentrations.