• Title/Summary/Keyword: Medical equipment

Search Result 1,262, Processing Time 0.039 seconds

Investigations on the emergency operation status of existing medical facilities to prepare for emerging infectious diseases in the post-COVID-19 era (포스트 코로나 시대 신종 감염병 대비를 위한 기존 의료시설의 비상시 운영사례 조사 및 분석)

  • Lee, Sejin;Lee, Wonseok;Kim, Eunseok;Yeo, Myoungsouk
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.1
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: To accommodate the increasing number of patients during the COVID-19 pandemic, numerous portable HEPA filter units (PHUs) were installed in the general wards of existing medical facilities(EMFs) to convert them into emergency conversion facilities (ECFs). The purpose of this study was to build a dataset in preparation for emerging infectious diseases in the post-COVID-19 era by analyzing the construction and operation of ECFs. Methods: Field investigations were conducted during ECF operation periods based on the analysis of heating, ventilation, and air conditioning (HAVC) system design documents for six ECFs across Korea. Interviews were conducted with facility managers during the field investigations. Results: When constructing an ECF within an EMF, the installation status and characteristics of the existing system should be considered. Field investigations and verifications of the operation of HAVC systems must be conducted beforehand for smooth ECF operations. If heating and cooling are required with indoor air circulation type equipment in an ECF zone, the implementation of a heating and cooling method that can satisfy the comfort requirements of the occupants while minimizing cross-contamination is essential. When using PHUs that do not meet the performance standards required by medical equipment, the noise level resulting from such equipment operation must be evaluated and improved. Implications: For EMFs, various guidelines that can be referred to for the construction and operation of ECFs must be developed to prepare for emerging infectious diseases in the future.

Development and verification of a novel system for computed tomography scanner model construction in Monte Carlo simulations

  • Ying Liu;Ting Meng ;Haowei Zhang ;Qi Su;Hao Yan ;Heqing Lu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4244-4252
    • /
    • 2022
  • The accuracy of Monte Carlo (MC) simulations in estimating the computed tomography radiation dose is highly dependent on the accuracy of CT scanner model. A system was developed to observe the 3D model intuitively and to calculate the X-ray energy spectrum and the bowtie (BT) filter model more accurately in Monte Carlo N-particle (MCNP). Labview's built-in Open Graphics Library (OpenGL) was used to display basic surfaces, and constructive solid geometry (CSG) method was used to realize Boolean operations. The energy spectrum was calculated by simulating the process of electronic shooting and the BT filter model was accurately modeled based on the calculated shape curve. Physical data from a study was used as an example to illustrate the accuracy of the constructed model. RMSE between the simulation and the measurement results were 0.97% and 0.74% for two filters of different shapes. It can be seen from the comparison results that to obtain an accurate CT scanner model, physical measurements should be taken as the standard. The energy spectrum library should be established based on Monte Carlo simulations with modifiable input files. It is necessary to use the three-segment splicing modeling method to construct the bowtie filter model.

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals (종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

A Survey of Utilizing Status and Demand for Medical Devices in Traditional Korean Medicine (한방의료기기 사용 현황 및 개발 수요에 대한 조사 연구)

  • Nam, Dong-Hyun
    • The Journal of Korean Medicine
    • /
    • v.34 no.1
    • /
    • pp.69-79
    • /
    • 2013
  • Objectives: The aim of this survey was to investigate utilization, intended use, problems with and demand for medical devices by surveying members of the traditional Korean medical society. Methods: We distributed questionnaires to 13,957 traditional Korean medical doctors via e-mail, and received replies from 1,225. The questionnaire consisted of 4 multiple-choice questions for survey respondent information, 8 multiple-choice questions about the status of medical devices utilizing, and a short answer question about the demand for medical devices. Results: Use of medical devices in traditional Korean medical clinics is common. Diagnostic medical devices are mainly used to assess the patient's condition and to establish a close rapport with clients. In case of therapeutic medical devices, they are usually used for secondary treatment. Issues with traditional Korean medical devices currently in use were ineligibility for national health insurance, low reliability, uncertain validity, and high price. In development of traditional Korean medical equipment, the need for diagnostic medical devices was greater than for therapeutic, and the need for the recording and analysis of medical image data and visualization of medical information was great. Conclusions: There is growing demand for facilitating the development and commercialization of traditional Korean medical devices. To satisfy this demand, research on evaluation indicators that reflect functional and structural clinical information and how to clinically assess the indicators should proceed.

Opinion Survey of Health Center Officers on Rural Health Service Improvement Project (농어촌의료(農漁村醫療)서비스 개선사업(改善事業)에 대한 보건소(保健所) 공무원(公務員)의 인식도(認識度))

  • Kim, Young-Gil;Park, Jae-Yong;Kam, Sin;Han, Chang-Hyun;Cha, Byung-Jun
    • Journal of agricultural medicine and community health
    • /
    • v.23 no.2
    • /
    • pp.175-192
    • /
    • 1998
  • This study was performed investigate the opinion of civil servants in Health center about Rural Health Service Improvement Project The survey by mail was carried out for 447 servants of 25 health centers in Kyungsangbuk-do and the data were collected through self-administered questionnaires to servants about need, participation, concern, and comprehension for the project and satisfied with current facility and equipment of health center. The results were as follows. Generally considered, 48.2% of the improved health center servants was satisfied with health center building and 14.0% or 24.1% of the improving or unimproved center was. About the location of health center, 37.7% of the improved health center servants was satisfied, 25.9% of the unimproved center was. Of the improved health center servants, 43% was satisfied with the medical equipment but in unimproved place, the dissatisfaction was appeared higher than any other place. 49.7% of respondents was participated in making out the Rural Health Service Improvement Project. 50.6% was interested in this project. In the improved area. 65.5% of health center servants replied that the mayor's or county executive's concern about this project was high and 46.5% in councilors but in the unimproved area. their concern was low. About the contents of the project. 24,6% of the servants in the improved center, only 15.2% in unimproved center replied that they had known well. After making out the plan, 13.6% of respondents was unsatisfied with this plan and 17.1% replied that the estimating method of selecting the project area was not good. After the improvement of institution and equipment, 86.1% of health center servants answered that the medical service provided by health center would increase but 59.2% replied that the residents' utilization rate of private medical facility would decrease. The servants of the improved health center replied that the recognition about the developing will of health service(91.2%), the efficiency(91.2%), the quality of health and medical service(93.0%), the amount of health project(91.2%) were improved. In health center which had already improved the institution and equipment, 88.5% of servants replied that the residents' utilization for health center was increased. So, this project should be continuously carried out for health center and health center must develope new project to fit region condition.

  • PDF

Evaluation of Reliability about Short TAT (Turn-Around Time) of Domestic Automation Equipment (Gamma Pro) (국산 자동화 장비(Gamma Pro)의 결과보고시간 단축에 대한 유용성 평가)

  • Oh, Yun-Jeong;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.197-202
    • /
    • 2010
  • Purpose: Recently, many hospitals have been tried to increase the satisfaction of the outpatients through blood-gathering, exam, result notice and process in a day. Each laboratory has been used the automatic equipment for the rapid requests of the result notice and the increase of the reliability and efficiency. Current automatic equipments that have been limited short TAT(Turn-Around Time)because of the restricted batch lists and 1 tip-5 detectors. The Gamma Pro which is made in Korea to improve the shortcomings of existing automation equipment, complemented with capacity to perform a wide range of domestic automation equipment. In this study, we evaluated the usefulness and reliability of short TAT by comparing Gamma Pro with current automatic equipment. Materials and Methods: We studied the correlation between Gamma Pro and RIA-mat 280 using the respective 100 specimens of low or high density to the patients who were requested the thyroid hormone test (Total T3, TSH and Free T4) in Samsung Medical Center Sep. 2009. To evaluate the split-level Gamma Pro, First, we measured accuracy and carry over on the tips. Second, the condition of optimal incubation was measured by the RPM (Revolution Per Minute) and revolution axis diameter on the incubator. For the analysis for the speed of the specimen-processing, TAT was investigated with the results in a certain time. Result: The correlation coefficients (R2) between the Gamma Pro and RIA-mat 280 showed a good correlation as T3 (0.98), TSH (0.99), FT4 (0.92). The coefficient of variation (C.V) and accuracy was 0.38 % and 98.3 % at tip 1 and 0.39 % and 98.6 % at tip 2. Carry over showed 0.80 % and 1.04% at tip 1 and tip 2, respectively. These results indicate that tips had no effect on carry over contamination. At the incubator condition, we found that the optimal condition was 1.0mm of diameter at 600RPM in 1.0mm and 1.5mm of at 500RPM or 1.0mm and 1.5 mm of diameter at 600 RPM. the Gamma Pro showed that the number of exam times were increased as maximum 20 times/day comparing to 6 times/day by current automatic equipment. These results also led to the short TAT from 4.20 hour to 2.19 hours in whole processing. Conclusion: The correlation of between the Gamma Pro and RIA-mat 280 was good and has not carry over contamination in tips. The domestic automation equipment (Gamma Pro) decreases the TAT in whole test comparing to RIA-280. These results demonstrate that Gamma Pro has a good efficiency, reliability and practical usefulness, which may contribute to the excellent skill to process the large scale specimens.

  • PDF

Editorial for Vol. 30, Issue 1 (편집자 주 - 30권 1호)

  • Kim, Young Hyo
    • Korean journal of aerospace and environmental medicine
    • /
    • v.30 no.1
    • /
    • pp.1-2
    • /
    • 2020
  • In commemoration of Vol. 30, Issue 1, our journal prepares four review articles and two original papers. The first review article provides guidelines for medical treatment for emergencies in an aircraft furing flight. This guideline addresses the resources and medical equipment available to physicians on board, common medical conditions, how to deal with them, including legal issues. The second review article covers historically meaningful animals that have contributed to aerospace research and the role of a veterinarian. The third one describes cardiovascular, musculoskeletal, and vestibular physiological effects of microgravity on the human body. As we are about to enter an aging society, the fourth review article introduces guidelines for safe overseas travel for senior passengers. The role of the aviation medical examiner is to maintain aircrew's health and to help them work long and healthy. In this regard, Choi et al. analyzed the physical examination data and sick leave data of an airline. Han et al. investigated the aerospace medical examination data of the Republic of Korea and suggested a solution to some common health problems of the crew.

Korean Guideline for Managing In-flight Medical Events (한국형 기내 의학적 상황 대처 방안 안내서)

  • Kim, Jungeon;Park, Nah-Lee;Kim, Jung Ha;Kwon, Young Hwan
    • Korean journal of aerospace and environmental medicine
    • /
    • v.30 no.1
    • /
    • pp.3-17
    • /
    • 2020
  • The cabin environment has many physiological effects on commercial aircraft passengers and medical providers, and environmental stress factors exist. Therefore, it is important for medical providers to understand the effects of aviation physiology and cabin environment on the human body. It should also be remembered that these physiological changes and environmental stress factors can affect passengers as well as flight crew and also medical equipment. Providing medical assistance during a flight offers a number of unique challenges including lower cabin pressure, tight quarters, crowded conditions, and loud background noise. The purpose of this Korean guideline is to offer an overview on various in-flight emergencies that could be anticipated and to outline treatment priorities.

Design of a Seismic Isolation Table for both indoor and outdoor Electrical Communication Equipment (전기통신설비를 위한 옥내외 겸용 면진테이블 설계)

  • Lee, Chun-Se;Ahn, Hyeong-Joon;Lee, Taek-Won;Son, In-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.472-472
    • /
    • 2009
  • The safety of cultural properties, medical treatment and electrical communication equipments in a building was hardly considered against the earthquake induced vibration, while the integrity of the building structure has been taken into account through the resistant earthquake design. This paper presents design of a seismic isolation table for both indoor and outdoor electrical communication equipment. First of all, artificial earthquake waves compatible with floor and ground response spectra for electrical communication equipments are generated using previously recorded seismic waves. Two kinds of one-degree-of-freedom seismic isolation table systems: spring-linear damper and spring-friction damper systems are considered and their responses to artificial earthquake waves are simulated. Design parameter study for two seismic isolation tables are performed through simulations and a seismic isolation table for both indoor and outdoor electrical communication equipment is designed considering the simulation results.

  • PDF