• 제목/요약/키워드: Medical bone fixation plate

검색결과 31건 처리시간 0.023초

Subbrow Approach as a Minimally Invasive Reduction Technique in the Management of Frontal Sinus Fractures

  • Lee, Yewon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.679-685
    • /
    • 2014
  • Background Frontal sinus fractures, particularly anterior sinus fractures, are relatively common facial fractures. Many agree on the general principles of frontal fracture management; however, the optimal methods of reduction are still controversial. In this article, we suggest a simple reduction method using a subbrow incision as a treatment for isolated anterior sinus fractures. Methods Between March 2011 and March 2014, 13 patients with isolated frontal sinus fractures were treated by open reduction and internal fixation through a subbrow incision. The subbrow incision line was designed to be precisely at the lower margin of the brow in order to obtain an inconspicuous scar. A periosteal incision was made at 3 mm above the superior orbital rim. The fracture site of the frontal bone was reduced, and bone fixation was performed using an absorbable plate and screws. Results Contour deformities were completely restored in all patients, and all patients were satisfied with the results. Scars were barely visible in the long-term follow-up. No complications related to the procedure, such as infection, uncontrolled sinus bleeding, hematoma, paresthesia, mucocele, or posterior wall and brain injury were observed. Conclusions The subbrow approach allowed for an accurate reduction and internal fixation of the fractures in the anterior table of the frontal sinus by providing a direct visualization of the fracture. Considering the surgical success of the reduction and the rigid fixation, patient satisfaction, and aesthetic problems, this transcutaneous approach through a subbrow incision is concluded to be superior to the other reduction techniques used in the case of an anterior table frontal sinus fracture.

경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향 (Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation)

  • 김근수
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권4호
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석 (Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate)

  • 권경제;조명래;오종건;이성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

Cement Augmentation of Dynamic Hip Screw to Prevent Screw Cut Out in Osteoporotic Patients with Intertrochanteric Fractures: A Case Series

  • Rai, Avinash Kumar;Goel, Rajesh;Bhatia, Chirag;Singh, Sumer;Thalanki, Srikiran;Gondane, Ashwin
    • Hip & pelvis
    • /
    • 제30권4호
    • /
    • pp.269-275
    • /
    • 2018
  • Purpose: The purpose of this study is to describe a method of inserting cement in the femoral head before fixation with dynamic hip screw to prevent screw cut out due to osteoporosis and to evaluate its clinical outcome in these patients. Materials and Methods: In this prospective study, 30 patients aged 60 years and older with intertrochanteric fracture were included. Bone mineral density was measured. After reaming of the femoral head and neck with a triple reamer and polymethyl methacrylate, bone cement was introduced into the femoral head using a customized nozzle and a barrel fitted on a cement gun. A Richard screw was inserted and the plate was fixed over the femoral shaft. Patients were mobilized and clinical outcomes were rated using the Salvati and Wilson's scoring system. Results: More patients included in this study were between 66 and 70 years old than any other age group. The most common fracture according to the Orthopaedic Trauma Association classification was type 31A2.2 (46.7%). The T-score was found to be $-2.506{\pm}0.22$ (mean${\pm}$standard deviation); all patients were within the range of -2.0 to -2.8. The duration of radiological union was $13.67{\pm}1.77$ weeks. Salvati and Wilson's scoring at 12 months of follow up was $30.96{\pm}4.97$. The majority of patients were able to perform their normal routine activities; none experienced implant failure or screw cut out. Conclusion: Bone cement augmentation may effectively prevent osteoporosis-related hardware complications like screw cut out in elderly patients experiencing intertrochanteric fractures.

Surgical outcomes of sternal rigid plate fixation from 2005 to 2016 using the American College of Surgeons-National Surgical Quality Improvement Program database

  • Tran, Bao Ngoc N.;Chen, Austin D.;Granoff, Melisa D.;Johnson, Anna Rose;Kamali, Parisa;Singhal, Dhruv;Lee, Bernard T.;Fukudome, Eugene Y.
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.336-343
    • /
    • 2019
  • Background Sternal rigid plate fixation (RPF) has been adopted in recent years in high-risk cases to reduce complications associated with steel wire cerclage, the traditional approach to sternal closure. While sternal RPF has been associated with lower complication rates than wire cerclage, it has its own complication profile that requires evaluation, necessitating a critical examination from a national perspective. This study will report the outcomes and associated risk factors of sternal RPF using a national database. Methods Patients undergoing sternal RPF from 2005 to 2016 in the American College of Surgeons-National Surgical Quality Improvement Program were identified. Demographics, perioperative information, and complication rates were reviewed. Logistic regression analysis was performed to identify risk factors for postoperative complications. Results There were 381 patient cases of RPF identified. The most common complications included bleeding (28.9%), mechanical ventilation >48 hours (16.5%), and reoperation/readmission (15.2%). Top risk factors for complications included dyspnea (odds ratio [OR], 2.672; P<0.001), nonelective procedure (OR, 2.164; P=0.010), congestive heart failure (OR, 2.152; P=0.048), open wound (OR, 1.977; P=0.024), and operating time (OR, 1.005; P<0.001). Conclusions Sternal RPF is associated with increased rates of three primary complications: blood loss requiring transfusion, ventilation >48 hours, and reoperation/readmission, each of which affected over 15% of the study population. Smokers remain at an increased risk for surgical site infection and sternal dehiscence despite RPF's purported benefit to minimize these outcomes. Complications of primary versus delayed sternal RPF are roughly equivalent, but individual patients may perform better with one versus the other based on identified risk factors.

컴퓨터단층촬영과 파노라마상을 이용한 한국인 하치조관의 하악에서의 협, 설측 위치 관계에 대한 연구 (STUDY ON THE RELATIONSHIP OF THE INFERIOR ALVEOLAR NERVE POSITION BETWEEN BUCCAL AND LINGUAL SIDE USING CT AND ORTHPANTOMOGRAM)

  • 신홍수;황순정
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권1호
    • /
    • pp.1-6
    • /
    • 2002
  • When bilateral sagittal split ramus osteotomy or mandibular angle reduction are carried out, we have to consider the position of inferior alveolar nerve. For bone splitting or resection using a saw or an osteotome, the bucco-lingual position of the inferior alveolar nerve plays an important role in the preventing perioperative complications such as paresthesia or anesthesia. Because it is rare to find literatures concerning the mean anatomic position of the inferior alveolar nerve in Koreans, we investigated 30 patients who underwent to take CT and orthopantomogram for implant surgery, and evaluated the bucco-lingual position and vertical relationship of the inferior alveolar nerve at the mandible. The results showed that the distance between inferior alveolar nerve and buccal plate was the farthest at mandibular second molar ($7.1{\sim}7.4mm$) and the nearest at mandibular angle area ($4.4{\sim}4.8mm$). But it was no statistical relationship between the bucco-lingual postion of inferior alveolar nerve on the CT and its vertical position on the OPT. In conclusion, the results suggest that a careful surgical procedure is needed at the mandibular angle area to avoid a nerve damage and there are sufficient bone materials at the mandibular second molar are for bilateral sagittal split ramus osteotomy or mandibular angle reduction or plate fixation. And OPT is not usefull for the evaluation of a relative bucco-lingual position of inferior alveolar nerve in relation to its vertical postion on the OPT.

두개 악안면 수술 후 플레이트 제거에 관한 후향적 연구 (The Removal of Plates after Craniomaxillofacial Surgery: A Retrospective Study)

  • 박대균;유상철;박승하;구상환
    • Archives of Plastic Surgery
    • /
    • 제34권2호
    • /
    • pp.186-190
    • /
    • 2007
  • Purpose: Plate systems have been used for osteosynthesis of cranial and oromaxillofacial fracture. However, there is no consensus on the need for routine removal of plate and the question about indications of removal. Therefore, we present the retrospective study to clarify the indications and consensus of removal. Methods: The medical records of patients who were treated with rigid internal fixation using plates after craniofacial trauma were reviewed. Study variables included age, gender, type of fracture, type of plate, seniority of the operator, causes of removal, and time between insertion and removal. All results amendable to statistics were analyzed using SPSS 10.0 to determine which set of variables might affect the fate of the plates. Results: For a period of 10 years (March 1, 1994 through July 31, 2004), total of 41 plates(6.7%) were removed among 609 plates inserted into 419 patients; 27 plates were removed from 15 patients for infection, which is the most common cause of removal accounting for 65.8%. Mean time between insertion and removal is 35.2 months and mean age is 41.4 years. Most plates were removed from combined fracture(14.92%) and facial fracture(8.47%) and these were statistically significant. The age, gender, seniority of the operator and other variables were not statistically associated with plate removal. Conclusion: This retrospective study shows that routine removal does not appear to be clinically indicated due to respectively low removal rate and that the commonest indications for removal were infection.

잠김 금속판을 이용한 하지의 전이성 병적 골절에 대한 치료 (Metastatic Pathologic Fractures in Lower Extremities Treated with the Locking Plate)

  • 서창영;정성택
    • 대한골관절종양학회지
    • /
    • 제16권2호
    • /
    • pp.80-86
    • /
    • 2010
  • 목적: 골격계는 전이성 암에 의해 흔히 영향을 받는 부위이다. 본 연구를 통해 하지에서 발생한 전이성 병적 골절에 대한 치료로서 잠김 금속판을 이용한 치료 결과에 대해 알아보고자 한다. 대상 및 방법: 2004년부터 2010년까지 하지에 발생한 전이성 암에 의한 병적 골절에 대하여 잠김 금속판을 이용하여 치료받은 12명(13예)의 환자를 대상으로 평가를 시행하였다. 평균 환자 나이는 62.2세(50-81세)였으며, 골절은 각각 근위 대퇴골 2예, 대퇴골 간부 3예, 원위 대퇴골 3예, 근위 경골 4예, 원위 대퇴골 1예에서 발생하였다. 치료 결과로서 휠체어 보행 가능 시기, 통증 완화 정도 및 합병증을 평가하였으며, 또한 수술 시간 및 술 후 실혈량에 대하여 평가하였다. 결과: 수술 후부터 휠체어 보행까지는 평균 3.2일(1-6일)이 소요되었다. 평균 시각 통증 척도는 수술 전 8.1점(7-9점)에서 술 후 1주일째 2.7점(2-4점)으로 호전되었으며, 수술과 연관된 조기 합병증은 발생하지 않았다. 평균 수술 시간은 88.4분(70-105분)이었으며, 술후 평균 실혈량은 246.5 ml (130-320 ml)이었다. 결론: 하지의 전이성 병적 골절에 대한 치료로서, 잠김 금속판을 이용한 내고정술은 심한 골 파괴나 골 결손을 보이는 장골의 골간단부 혹은 골간부 병변에 효과적인 치료 방법이며, 또한 조기 보행을 가능하게 하고, 통증 및 술후 합병증 감소에 도움을 줄 수 있을 것이다.

Refracture after locking compression plate removal in displaced midshaft clavicle fractures after bony union: a retrospective study

  • Park, Ho-Youn;Kim, Seok-Jung;Sur, Yoo-Joon;Jung, Jae-Woong;Kong, Chae-Gwan
    • Clinics in Shoulder and Elbow
    • /
    • 제24권2호
    • /
    • pp.72-79
    • /
    • 2021
  • Background: A midshaft clavicle fracture is a common fracture that typically responds well to open reduction and internal fixation (ORIF). However, refracture can occur after implant removal (IR). This study aimed to analyze the rate of refracture and related factors after removal of the locking compression plate (LCP) for displaced midshaft clavicle fractures. Methods: We retrospectively reviewed the medical records of 201 patients who had undergone ORIF with LCP for midshaft clavicle fractures after IR after bony union from January 2011 to May 2018 at our institute. We evaluated basic demographic characteristics and radiographic parameters. All patients were treated with an LCP for primary fracture. The patients were divided into two groups: a refracture group that experienced a second fracture within 1 year after IR and a no-fracture group. Results: There were four cases (1.99%) of refracture; three were treated conservatively, while one was treated surgically. All patients achieved bony union. The average interval between refracture and IR was 64 days (range, 6-210 days). There was a significant difference in classification of fractures (AO Foundation/Orthopaedic Trauma Association [AO/OTA] classification) between the two groups. However, other patient demographics and radiographic measurements between refracture and IR, such as bone diameter, showed no significant difference between the two groups. Conclusions: This study showed that one in 50 patients suffered from refracture after removal of the LCP. Thus, if patients desire IR, the surgeon should explain that there is a relatively higher possibility of refracture for cases with simple or segmental fractures than for other types of fracture.

Clinical characteristics of patients with the hardware failure after surgical stabilization of rib fractures in Korea: a case series

  • Na Hyeon Lee;Sun Hyun Kim;Seon Hee Kim;Dong Yeon Ryu;Sang Bong Lee;Chan Ik Park;Hohyun Kim;Gil Hwan Kim;Youngwoong Kim;Hyun Min Cho
    • Journal of Trauma and Injury
    • /
    • 제36권3호
    • /
    • pp.196-205
    • /
    • 2023
  • Purpose: Surgical stabilization of rib fractures (SSRF) is widely used in patients with flail chests, and several studies have reported the efficacy of SSRF even in multiple rib fractures. However, few reports have discussed the hardware failure (HF) of implanted plates. We aimed to evaluate the clinical characteristics of patients with HF after SSRF and further investigate the related factors. Methods: We retrospectively reviewed the electronic medical records of patients who underwent SSRF for multiple rib fractures at a level I trauma center in Korea between January 2014 and January 2021. We defined HF as the unintentional loosening of screws, dislocation, or breakage of the implanted plates. The baseline characteristics, surgical outcomes, and types of HF were assessed. Results: During the study period, 728 patients underwent SSRF, of whom 80 (10.9%) were diagnosed with HF. The mean age of HF patients was 56.5±13.6 years, and 66 (82.5%) were men. There were 59 cases (73.8%) of screw loosening, 21 (26.3%) of plate breakage, 17 (21.3%) of screw migration, and seven (8.8%) of plate dislocation. Nine patients (11.3%) experienced wound infection, and 35 patients (43.8%) experienced chronic pain. A total of 21 patients (26.3%) underwent reoperation for plate removal. The patients in the reoperation group were significantly younger, had fewer fractures and plates, underwent costal fixation, and had a longer follow-up. There were no significant differences in subjective chest symptoms or lung capacity. Conclusions: HF after SSRF occurred in 10.9% of the cases, and screw loosening was the most common. Further longitudinal studies are needed to identify risk factors for SSRF failure.