• Title/Summary/Keyword: Medical and biological imaging

Search Result 436, Processing Time 0.024 seconds

SPECTROSCOPIC ADMITTIVITY IMAGING OF BIOLOGICAL TISSUES: CHALLENGES AND FUTURE DIRECTIONS

  • Zhang, Tingting;Bera, Tushar Kanti;Woo, Eung Je;Seo, Jin Keun
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.18 no.2
    • /
    • pp.77-105
    • /
    • 2014
  • Medical imaging techniques have evolved to expand our ability to visualize new contrast information of electrical, optical, and mechanical properties of tissues in the human body using noninvasive measurement methods. In particular, electrical tissue property imaging techniques have received considerable attention for the last few decades since electrical properties of biological tissues and organs change with their physiological functions and pathological states. We can express the electrical tissue properties as the frequency-dependent admittivity, which can be measured in a macroscopic scale by assessing the relation between the time-harmonic electric field and current density. The main issue is to reconstruct spectroscopic admittivity images from 10 Hz to 1 MHz, for example, with reasonably high spatial and temporal resolutions. It requires a solution of a nonlinear inverse problem involving Maxwell's equations. To solve the inverse problem with practical significance, we need deep knowledge on its mathematical formulation of underlying physical phenomena, implementation of image reconstruction algorithms, and practical limitations associated with the measurement sensitivity, specificity, noise, and data acquisition time. This paper discusses a number of issues in electrical tissue property imaging modalities and their future directions.

A Review of Brain Magnetic Resonance Imaging Correlates of Successful Cognitive Aging (뇌자기공명영상의 노화에 따른 변화)

  • Ji, Eun-Kyung;Chung, In-Won;Youn, Tak
    • Korean Journal of Biological Psychiatry
    • /
    • v.21 no.1
    • /
    • pp.1-13
    • /
    • 2014
  • Normal aging causes changes in the brain volume, connection, function and cognition. The brain changes with increases in age and difference of gender varies at all levels. Studies about normal brain aging using various brain magnetic resonance imaging (MRI) variables such as gray and white matter structural imaging, proton spectroscopy, apparent diffusion coefficient, diffusion tensor imaging and functional MRI are reviewed. Total volume of brain increases after birth but decreases after 9 years old. During adulthood, total volume of brain is relatively stable. After 35 years old, brain shrinks gradually. The changes of gray and white matters by aging show different features. N-acetylaspartate decreases or remains unchanged but choline, creatine and myo-inositol increase with aging. Apparent diffusion coefficient decreases till 20 years old and then becomes stable during adulthood and increase after 60 years old. Diffusion tensor properties in white matter tissue are variable during aging. Resting-state functional connectivity decreases after middle age. Structural and functional brain changes with normal aging are important for studying various psychiatric diseases such as dementia, schizophrenia and bipolar disorder. Our review may be helpful for studying longitudinal changes of these diseases and successful aging.

Study of Efficiency Test Evaluations Method for Imaging Device Based Laser Equipment (영상장치 기반 정밀치료용 레이저 수술기의 성능 평가 방법 개발)

  • Kim, Dae Chang;Lee, Seung Bong;Jeong, Jae Hoon;Kim, Sung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.230-234
    • /
    • 2019
  • Medical laser equipment using optical energy is used to surgery and treat diseases by destroying and removing tissue. Domestic laser equipment has been used steadily in the skin and cosmetics sectors and has been changed to radiate high-power energy in a wide range to shorten patient treatment time. However, side effects such as burns and damage of normal tissues occurred. To solve this problem, techniques for detecting lesions using an imaging device and selectively radiating the laser have been developed. In this study, we proposed an evaluation method to evaluate the safety and performance of target detection accuracy, laser irradiation accuracy and motion protection device technology derived from product analysis and investigation. Finally, the validity of the evaluation method was evaluated by evaluating the imaging device based laser equipment as the proposed evaluation method.

Neurobiological Basis of Anxiety Related Disorders (불안 관련 장애의 신경생물학적 이해)

  • Kim, Kyung-Min;Kim, Min-Kyoung;Lee, Sang-Hyuk
    • Korean Journal of Biological Psychiatry
    • /
    • v.21 no.4
    • /
    • pp.128-140
    • /
    • 2014
  • Anxiety disorders are characterized by dysregulation of neuroendocrine, neurotransmitter and neuroanatomical functions. Substantial advances in research method offered new insights into the neurobiologic mechanisms in anxiety disorders. Advances in molecular biology have enabled illumination of hormone and neurotransmitters that have important roles in anxiety. The neuroanatomic circuits related to anxiety are also being elucidated by improvements in neuroimaging technology such as structural and functional magnetic resonance imaging. This article reviews the research data in relation to the neurobiology underlying fear and pathologic anxiety and discusses their implications for development of biological treatments for anxiety disorders.

Recent Advances in Nuclear Medicine Imaging Instrumentation (핵의학 영상기기의 최근 진보)

  • Jung, Jin-Ho;Choi, Yong;Hong, Key-Jo;Min, Byung-Jun;Hu, Wei;Kang, Ji-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.98-111
    • /
    • 2008
  • This review introduces advances in clinical and pre-clinical single photon emission computed tomography (SPECT) and positron emission tomography (PET) providing noninvasive functional images of biological processes. Development of new collimation techniques such as multi-pinhole and slit-slat collimators permits the improvement of system spatial resolution and sensitivity of SPECT. Application specific SPECT systems using smaller and compact solid-state detector have been customized for myocardial perfusion imaging with higher performance. Combined SPECT/CT providing improved diagnostic and functional capabilities has been introduced. Advances in PET and CT instrumentation have been incorporated in the PET/CT design that provide the metabolic information from PET superimposed on the anatomic information from CT. Improvements in the sensitivity of PET have achieved by the fully 3D acquisition with no septa and the extension of axial field-of-view. With the development of faster scintillation crystals and electronics, time-of-flight (TOF) PET is now commercially available allowing the increase in the signal-to-noise ratio by incorporation of TOF information into the PET reconstruction process. Hybrid PET/SPECT/CT systems has become commercially available for molecular imaging in small animal models. The pre-clinical systems have improved spatial resolution using depth-of-interaction measurement and new collimators. The recent works on solid state detector and dual modality nuclear medicine instrumentations incorporating MRI and optical imagers will also be discussed.

헤파린화 혈액 적합성 고분자 재료

  • 한동근;김영하
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.255-270
    • /
    • 1987
  • A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network).

  • PDF

Study on the Real Time Medical Image Processing (실시간 의학 영상 처리에 관한 연구)

  • 유선국;이건기
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.118-122
    • /
    • 1987
  • The medical image processing system is intended for a diverse set of users in the medical Imaging Parts. This system consists of a 640 Kbyte IBM-PC/AT with 30 Mbyte hard disk, special purpose image processor with video input devices and display monitor. Image may be recorded and processed in real time at sampling rate up to 10 MHz. This system provides a wide range of image enhancement processing facilities via a menu-driven software packages. These facilities include point by point processing, image averaging, convolution filter and subtraction.

  • PDF

Development of a Micro-CT System for Small Animal Imaging (소 동물 촬영을 위한 Micro-CT의 개발)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.97-102
    • /
    • 2004
  • We developed an x-ray cone-beam micro computed tomography (micro-CT) system for small-animal imaging. The micro-CT system consists of a 2-D flat-panel x-ray detector with a field-of-view (FOV) of 120${\times}$120 mm2, a micro-focus x-ray source, a scan controller and a parallel image reconstruction system. Imaging performances of the micro-CT system have been evaluated in terms of contrast and spatial resolution. The minimum resolvable contrast has been found to be less than 36 CT numbers at the dose of 95 mGy and the spatial resolution about 14 lp/mm. As small animal imaging results, we present high resolution 3-D images of rat organs including a femur, a heart and vessels. We expected that the developed micro-CT system can be greatly used in biomedical studies using small animals.

Kinetic analysis of 64Cu-NODAGA-gluco-E[c(RGDfK)]2 for a tumor angiogenesis PET tracer

  • Choi, Jae Yong;Park, Ji-Ae;Kim, Jung Young;Lee, Ji Woong;Lee, Minkyung;Shin, Un Chol;Kang, Joo Hyun;An, Gwang Il;Lee, Kyo Chul;Ryu, Young Hoon;Kim, Kyeong Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.2
    • /
    • pp.108-112
    • /
    • 2016
  • Molecular imaging with the radiolabeled RGD peptides for ${\alpha}_v{\beta}_3$ integrin has been an increasing interest for tumor diagnosis and the treatment monitoring. Recently, $^{64}Cu$-NODAGA-gluco-E[c(RGDfK)]$_2$ was developed for quantification of ${\alpha}_v{\beta}_3$ integrin and its biological properties was elucidated. To better understand the molecular process in vivo, we performed the kinetic analysis for the $^{64}Cu$-NODAGA-gluco-E[c(RGDfK)]$_2$. After preparation of a radiotracer, dynamic PET images were obtained in the U87MG xenograft mice for 60 min (n = 6). Binding potential values were estimated from the 3-tissue compartment model, reference Logan and simplified reference tissue model. In the early time frame (0-20 min), the liver, kidney, intestine, urinary bladder and tumor were visualized but these uptakes were diminished as time went by. The tumors showed a good contrast at 40 min after administration. $^{64}Cu$-NODAGA-gluco-E[c(RGDfK)]$_2$ showed the 2-fold uptake in the tumor compared with that in the muscle. The parametric maps for binding values also provide the higher tumor-to-background contrast than the static images. A binding value obtained from the 3-tissue compartment model was comparable to other modeling methods. From these results, we conclude that $^{64}Cu$-NODAGA-gluco-E[c(RGDfK)]$_2$ may be a promising PET radiotracer for the evaluation of angiogenesis.

A New Synthetic Aperture Technique Using Linear Wave Fronts (선형 파면을 이용한 새로운 합성구경 기법)

  • 장진호;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.321-330
    • /
    • 2001
  • In this paper, we propose a new synthetic aperture focusing scheme for improving the lateral resolution which is one of the most important factors determining the quality of ultrasound imaging. The proposed scheme enables full round-trip dynamic focusing with approximately limited property. This properties are obtained through transmitting plane waves of which the traveling angle varies with the receive subaperture position, as opposed to stepping the spherical wave source across an array in other synthetic aperture focusing schemes, and employing dynamic focusing in receive. In this paper, the properties of the proposed scheme is analyzed in which a hypothetical infinite line source is used to transmit the plane waves and verified through computer simulation results. Also, we show that the proposed scheme is realizable with an array transducer with a finite aperture size. In summary, it is shown through comparison between the field contours of the proposed scheme and the conventional scheme that the proposed scheme can improve greatly the lateral resolution of ultrasound imaging.

  • PDF