• Title/Summary/Keyword: Medical X-ray

Search Result 1,675, Processing Time 0.025 seconds

The Characteristics of Eosinophilc Lung Diseases Cause by Toxocara Canis Larval Infestation (개회충 유충 감염에서 발생되는 호산구성 폐질환의 특성)

  • Kim, Yu Jin;Kyung, Sun Young;An, Chang Hyeok;Lim, Young Hee;Park, Jung Woong;Jeong, Seong Hwan;Lee, Sang Pyo;Choi, Dong Chull;Jeong, Young Bae;Kang, Shin Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Background: Toxocariasis is a common cause of eosinophilia and eosinophilic lung disease in Korea. We analyzed the characteristics of eosinophilic lung disease in toxocariasis. Method: One hundred and forty one patients with eosinophilia caused by a toxocara larval infection were evaluated from September 1, 2001 through March 30, 2006. The plain chest x-ray, chest CT(computed tomography), and bronchoalveolar larvage(BAL) were examined. A diagnosis of toxocariasis was made by ELISA using that secretory-excretory antigen from the T. canis larvae. Results: Toxocarial eosinophilic lung diseases was diagnosed in 32 out of 141 patients. Ground glass attenuation was the main feature on the CT scans in 23 out of 141 patients (71.9%). Thirteen patients (40.6%) had a random in zonal distribution on CT. Pleural effusion was observed in 9 patients (28.1%). Twenty eight patients (87.5%) complained of respiratory symptoms. Eleven patients (34.4%) had gastrointestinal symptoms and 12 patients (37.5%) had liver infiltration. Conclusions: The most common findings of the chest CT in patients with toxocariasis was a randomly distributed ground grass attenuation. A toxocara infection should be considered in a differential diagnosis of patients who exhibit pulmonary infiltration with eosinophilia in Korea.

Efficacy of Small Bowel Displacement System in Post-Operative Pelvic Radiation Therapy of Rectal Cancer (소장 용적 측정을 통한 직장암의 수술 후 방사선치료 시 사용하는 소장 전위 장치(Small Bowel Displacement System : SBDS) 의 효용성 검토)

  • Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyung;Wu Hong Gyun;Kim Dae Yong;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.63-69
    • /
    • 1998
  • Purpose : This study is to evaluate the efficacy of small bowel displacement system(SBDS) in post-operative pelvic radiation therapy(RT) of rectal cancer patients by measurement of small bowel volume included in the radiation fields receiving therapeutic dose. Materials and Method : Ten consecutive new rectal cancer patients referred to the department of Radiation Oncology of Samsung Medical Center in May of 1997 were included in this study. All patients were asked to drink $Castrographin^(R)$ before simulation and were laid prone for conventional simulation and CT scans with and without SBDS. The volume of opacified small bowel on CT scans, which was to be included in the radiation fields receiving therapeutic dose, was measured using Picture archiving and communication system (PACS). Results : The average small bowel volumes with and without SBDS were 176.0ml(5.2-415.6ml) and 185.1ml(54.5-434.2ml), respectively The changes of small bowel volume with SBDS compared to those without SBDS were more than $10\%$ decrease in three, less than 10% decrease in two, less than $10\%$ increase in three, and more than $10\%$ increase in two patients. Conclusion : No significant advantage of using SBDS in post-operative pelvic RT for rectal cancer patients has been shown by small bowel volume measurement using CT scan considering additional effort and time needed for simulation and treatment setup.

  • PDF

Role of Whole Body FDG-PET in the Diagnosis of Hidden Distant Metastasis before Liver Transplantation in Patients with Primary Liver Cancer (고식적 검사로 간외 전이를 진단하지 못한 원발성 간암 환자에서 간이식 전에 시행한 전신 FDG-PET의 역할)

  • Lee, Won-Woo;Ryu, Jin-Sook;Yang, You-Jung;Kim, Jae-Seung;Yeo, Jeong-Seok;Moon, Dae-Hyuk;Lee, Sung-Gyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.368-380
    • /
    • 2002
  • Purpose: Liver transplantation (LT), one of the therapeutic options of primary liver cancer has been suffering from recurrence caused by metastasis in 8-54% of patients. This study was performed to investigate whether FDG-PET is useful for detecting hidden metastasis in LT candidates. Materials and Methods: Twenty-six patients (male:female=23:3, mean age 55.7 years) underwent FDG-PET. Their previous conventional diagnostic studies (CDS) like abdomen US and CT, chest x-ray and CT, and bone scan were negative (n=22) or equivocal (n=4) for metastasis. Positive FDG-PET findings were confirmed by biopsy or clinical follow-up. Results: Among 4 patients with equivocal metastatic lesions on CDS, 3 had 6 hypermetabolic lesions on FDG-PET, which were confirmed as metastasis and subsequently LTs were cancelled. Of these, 5 lesions were initially negative on CDS. Remained 1 patient underwent LT with a negative FDG-PET result. Among 22 patients without metastasis on CDS, 5 had 7 hypermetabolic lesions on FDG-PET. One of these patients proved to have 2 metastatic lesions, and LT was cancelled. The other 4 patients had S hypermetabolic lesions on FDG-PET, which were confirmed as benign lesions, and 3 patients of them underwent LT. In summary, FDG-PET was useful in avoiding 4 unwarranted LT by detecting unsuspected metastatic lesions on CDS. A total of 17 patients underwent LT. In comparison with pathology, the sensitivity and specificity of FDG-PET for detecting viable primary liver cancer were 55.6% (5/9) and 87.5% (7/8), respectively. Conclusion: FDG-PET can detect additional hidden metastasis and contribute to reducing unwarranted LT in the patients with primary liver cancer.

Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization (경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가)

  • Min Jae Gu;Jae Hyuck Yi;Young Hwan Kim;Hee Jung Lee;Ung Rae Kang;Seung Woo Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.166-175
    • /
    • 2020
  • Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwent TACE with Iopamidol 250 (44 patients) and Ioversol 320 (69 patients) were retrospectively reviewed. Vessel perception on hepatic angiography was graded into three categories by two radiologists for hepatic subsegmental arteries, the right gastroepiploic artery, right gastric artery, and pancreaticoduodenal artery. Imaging concordance was assessed by comparing the number of detected HCCs on hepatic angiography and CT. The adverse events before and after hepatic angiography were evaluated. Results The mean vessel perception scores were 2.92 and 2.94 for Iopamidol 250 and Ioversol 320, respectively. The imaging concordance was 31 (70.5%) and 46 (66.7%) patients for Iopamidol 250 and Ioversol 320, respectively. There were no statistical differences in vessel perception or imaging concordance (p > 0.05). One and six patients experienced nausea for Iopamidol 250 and Ioversol 320, respectively. There was no statistical difference in adverse events (p = 0.24). Conclusion Iopamidol 250 can be used in hepatic angiography for TACE without significant difference in image quality or occurrence of adverse events from Ioversol 320.

Chest CT Findings of COVID-19 Patients with Mild Clinical Symptoms at a Single Hospital in Korea (경증의 임상 소견을 보이는 COVID-19 환자들의 흉부 CT 소견)

  • Woon Young Baek;Young Kyung Lee;Suhyun Kim;Chorom Hahm;Mi Young Ahn;Dong Hyun Oh;Jae-Phil Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.139-151
    • /
    • 2021
  • Purpose To retrospectively evaluate the chest computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) in patients with mild clinical symptoms at a single hospital in South Korea. Materials and Methods CT scans of 87 COVID-19 patients [43 men and 44 women; median age: 41 years (interquartile range: 26.1-51.0 years)] with mild clinical symptoms (fever < 38℃ and no dyspnea) were evaluated. Results CT findings were normal in 39 (44.8%) and abnormal in 48 (55.2%) patients. Among the 48 patients with lung opacities, 17 (35.4%) had unilateral disease and 31 (64.6%) had bilateral disease. One (2.1%) patient showed subpleural distribution, 9 (18.8%) showed peribronchovascular distribution, and 38 (79.2%) showed subpleural and peribronchovascular distributions. Twenty-two (45.8%) patients had pure ground-glass opacities (GGOs) with no consolidation, 17 (35.4%) had mixed opacities dominated by GGOs, and 9 (18.8%) had mixed opacities dominated by consolidation. No patients demonstrated consolidation without GGOs. Conclusion The most common CT finding of COVID-19 in patients with mild clinical symptoms was bilateral multiple GGO-dominant lesions with subpleural and peribronchovascular distribution and lower lung predilection. The initial chest CT of almost half of COVID-19 patients with mild clinical symptoms showed no lung parenchymal lesions. Compared to relatively severe cases, mild cases were more likely to manifest as unilateral disease with pure GGOs or GGO-dominant mixed opacities and less likely to show air bronchogram.

Surface characteristics of thermally treated titanium surfaces

  • Lee, Yang-Jin;Cui, De-Zhe;Jeon, Ha-Ra;Chung, Hyun-Ju;Park, Yeong-Joon;Kim, Ok-Su;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.3
    • /
    • pp.81-87
    • /
    • 2012
  • Purpose: The characteristics of oxidized titanium (Ti) surfaces varied according to treatment conditions such as duration time and temperature. Thermal oxidation can change Ti surface characteristics, which affect many cellular responses such as cell adhesion, proliferation, and differentiation. Thus, this study was conducted to evaluate the surface characteristics and cell response of thermally treated Ti surfaces. Methods: The samples were divided into 4 groups. Control: machined smooth titanium (Ti-S) was untreated. Group I: Ti-S was treated in a furnace at $300^{\circ}C$ for 30 minutes. Group II: Ti-S was treated at $500^{\circ}C$ for 30 minutes. Group III: Ti-S was treated at $750^{\circ}C$ for 30 minutes. A scanning electron microscope, atomic force microscope, and X-ray diffraction were used to assess surface characteristics and chemical composition. The water contact angle and surface energy were measured to assess physical properties. Results: The titanium dioxide ($TiO_2$) thickness increased as the treatment temperature increased. Additional peaks belonging to rutile $TiO_2$ were only found in group III. The contact angle in group III was significantly lower than any of the other groups. The surface energy significantly increased as the treatment temperature increased, especially in group III. In the 3-(4,5-Dimethylthiazol- 2-yl)-2,5-diphenyltetrazolium bromide assay, after 24 hours of incubation, the assessment of cell viability showed that the optical density of the control had a higher tendency than any other group, but there was no significant difference. However, the alkaline phosphatase activity increased as the temperature increased, especially in group III. Conclusions: Consequently, the surface characteristics and biocompatibility increased as the temperature increased. This indicates that surface modification by thermal treatment could be another useful method for medical and dental implants.

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.

Mixed Noise Reduction Filters for CR Images (CR X선 영상의 복합잡음 감소에 관한 연구)

  • Min, Jung-Whan;Jeong, Hea-Won;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • This study is to decrease compound noise in x-ray films. This study compared Signal to noise ratio(SNR), Peak signal to noise ratio(PSNR), Mean square error(MSE) to surface of the earth. In addition, we evaluated noise elimination effect according to the kernel size of Median filter. This experiments show that some filters are useful by finding image that is near in circle image comparing circle picture with each processed picture. In noise power value, when cutoff frequency was compared with other filters of cutoff frequency. Cutoff frequency of $2/3\pi{\sim}3/4\pi$ is good and it shows good SNR and PSNR. Therefore, it can display high filter effect. As Median Filter's Kernel size grows SNR value gets bigger, which shows better filter effect. Most pictures are distorted after filter application in medical treatment image. It is important to keep spatial resolution in most medical images. Visual estimation as well as quantitative indicators should be necessary for a better image.

  • PDF

고감도 형광판을 이용한 실시간 IMRT 선량 분석 가능성 연구

  • 고영은;이병용;안승도;이상욱;김종훈;신성수;최은경
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.36-36
    • /
    • 2003
  • 목적 : 고감도 형광판과 필름을 이용하여 실시간으로 선량을 측정하여 IMRT 선량분포를 검증하는데 사용하는 가능성을 알아보고자 하였다. 대상 및 방법 : 본 연구에서 개발한 물팬텀은 지름 25cm 아크릴 원통과 원통의 중앙부분에 삽입되는 고감도 형광판으로 구성되어 있다. 이를 사용하여 dose linearity correction factor를 구하기 위해 dmax 지점에서 6MV x-ray를 고감도형광판에 조사하여 blurring correction factor를 구하였다. CCD를 이용하여 고감도 형광판에서 나오는 영상을 수집하였다. 고감도 형광판에서 수집한 영상의 x축 profile은 RTP에서 얻은 profile과 비교하였고, 이온전리함으로 scanning한 데이터를 이용하여 고감도 형광판과 물에서 빛에 의한 산란선 때문에 발생하는 blurring effect를 교정하였다. 여기서 계산된 blurring effect factor를 고감도 형광판에서 수집된 영상에 적용하였다. 결과 : CCD 카메라는 형광판의 전 영역을 감지할 수 있고, 조사시간은 형광판의 중첩된 영상의 선량에 비례하였다. 물팬텀에서 형광판의 blurring effect 는 가우시안 분포로 표현할 수 있었다. 또한 Deconvolution kernel은 원통 팬텀에서 지름 $\pm$5cm 이내의 범위에 위치하였고, 따라서 형광판 영상으로부터의 실제 선량분 포를 뽑아낼 수 있었다. RTP 에서 계산된 선량분포와 blurring correction factor로 교정한 후 중첩시켜 얻은 고감도 형광판 영상의 선량분포는 일치하였다. 결론 : 정기적인 IMRT 선량 검증에 대한 실시간 선량측정 방법이 개발되었다. 고감도 형광판 영상과 CCD 카메라를 사용한 물팬텀으로, IMRT 치료계획에 대한 선량분포를 검증할 수 있는 가능성을 보였다.비의 회전에 의한 오차 보정, 필름의 광학적 밀도에 관한 보정 등 여러 가지 계통적 오차들에 대한 보정들이 선량분포 확인과정의 이해와 그 기준마련에 도움이 되겠지만 우리가 다룬 원점 불일치에 비해서 상대적으로 무시할 수 있었다. 마지막으로 선량분포 확인의 최종목표인 3 차원 선량분포 확인의 실제 적용을 위한 연구가 최적화 알고리듬을 이용하여 실험 중에 있다.\times$5cm, 10$\times$10cm, 15$\times$l5cm, 20$\times$20cm인 경우, 측정하여 얻은 PSF가 0.8%, 0.2%, 0.4%, 0.2%로 약간 높지만, 두 값은 매우 유사한 것으로 나타났다. 그리고, 기존의 BSF를 이용해 구한 TAR과 BJR 25에서 권고하는 PSF를 이용해 구한 TAR을 비교한 결과 field size 에 따라 약 1%-1.5% 정도로 BSF를 이용하여 구한 TAR보다 PSF를 이용하여 구한 TAR이 1.3% 정도 높게 나타났지만, 이것은 두 값의 절대적인 차이일 뿐, 실제로는 PSF를 이용하여 구한 TAR이 측정해서 구한 TAR과는 매우 유사한 값을 보여주고 있다. 결론 : 기존의 BSF를 이용해 구한 TAR과 PSF를 이용해 구한 TAR을 비교하였을 때, 약 1.3% 정도 높게 내고 있지만, 기존의 TAR보다는 PSF를 이용해 구한 TAR이 BJR 25와 잘 일치하고 있으므로 Co-60 원격치료용 방사선 조사장치를 사용할 경우 BSF보다는 PSF를 사용하는 것이 타당한 것으로 사료된다.tokines의 변화는 비록 통계학적인 차이는 없지만 비타민 C를 사용한 환자의 cytokines이 모두 사용하지 않은 환자에 비해 감소하였음을 보였다. 비타민 C는 부작용이 거의 없는 안전한 약으로서 말기 암 환자에서 비타민 C사용은 임상 증상을 호전시키는 데 도움

  • PDF

External cross-validation of bioelectrical impedance analysis for the assessment of body composition in Korean adults

  • Kim, Hyeoi-Jin;Kim, Chul-Hyun;Kim, Dong-Won;Park, Mi-Ra;Park, Hye-Soon;Min, Sun-Seek;Han, Seung-Ho;Yee, Jae-Yong;Chung, So-Chung;Kim, Chan
    • Nutrition Research and Practice
    • /
    • v.5 no.3
    • /
    • pp.246-252
    • /
    • 2011
  • Bioelectrical impedance analysis (BIA) models must be validated against a reference method in a representative population sample before they can be accepted as accurate and applicable. The purpose of this study was to compare the eight-electrode BIA method with DEXA as a reference method in the assessment of body composition in Korean adults and to investigate the predictive accuracy and applicability of the eight-electrode BIA model. A total of 174 apparently healthy adults participated. The study was designed as a cross-sectional study. FM, %fat, and FFM were estimated by an eight-electrode BIA model and were measured by DEXA. Correlations between BIA_%fat and DEXA_%fat were 0.956 for men and 0.960 for women with a total error of 2.1%fat in men and 2.3%fat in women. The mean difference between BIA_%fat and DEXA_%fat was small but significant (P < 0.05), which resulted in an overestimation of $1.2{\pm}2.2$%fat (95% CI: -3.2-6.2%fat) in men and an underestimation of $-2.0{\pm}2.4$%fat (95% CI: -2.3-7.1%fat) in women. In the Bland-Altman analysis, the %fat of 86.3% of men was accurately estimated and the %fat of 66.0% of women was accurately estimated to within 3.5%fat. The BIA had good agreement for prediction of %fat in Korean adults. However, the eight-electrode BIA had small, but systemic, errors of %fat in the predictive accuracy for individual estimation. The total errors led to an overestimation of %fat in lean men and an underestimation of %fat in obese women.