• Title/Summary/Keyword: Medical Use

Search Result 7,556, Processing Time 0.047 seconds

The effect of cavity wall property on the shear bond strength test using iris method (Iris 법을 이용한 전단접착강도 측정에서 와동벽의 영향)

  • Kim, Dong-Hwan;Bae, Ji-Hyun;Cho, Byeong-Hoon;Lee, In-Bog;Baek, Seung-Ho;Ryu, Hyun-Mi;Son, Ho-Hyun;Um, Chung-Moon;Kwon, Hyuck-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.170-176
    • /
    • 2004
  • Objectives : In the unique metal iris method. the developing interfacial gap at the cavity floor resulting from the cavity wall property during polymerizing composite resin might affect the nominal shear bond strength values. The aim of this study is to evaluate that the iris method reduces the cohesive failure in the substrates and the cavity wall property effects on the shear bond strength tests using iris method. Materials and Methods : The occlusal dentin of 64 extracted human molars were randomly divided into 4 groups to simulate two different levels of cavity wall property (metal and dentin iris) and two different materials ($ONE-STEP^{\circledR}$ and $ALL-BOND^{\circledR}$ 2) for each wall property. After positioning the iris on the dentin surface. composite resin was packed and light-cured. After 24 hours the shear bond strength was measured at a crosshead speed of 0.5 mm/min. Fracture analysis was performed using a microscope and SEM. The data was analyzed statistically by a two-way ANOV A and t-test. Results : The shear bond strength with metal iris was significant higher than those with dentin iris (p=0.034). Using $ONE-STEP^{\circledR}$, the shear bond strength with metal iris was significant higher than those with dentin iris (p=0.005), but not in $ALL-BOND^{\circledR}$ 2 (p=0.774). The incidence of cohesive failure was very lower than other shear bond strength tests that did not use iris method. Conclusions:The iris method may significantly reduce the cohesive failures in the substrates. According to the bonding agent systems. the shear bond strength was affected by the cavity wall property.

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

The Development of Education Model for CA-RP(Cognitive Apprenticeship-Based Research Paper) to Improve the Research Capabilities for Majors Students of Radiological Technology (방사선 전공학생의 연구역량 증진을 위한 인지적 도제기반 논문작성 교육 모형 개발)

  • Park, Hoon-Hee;Chung, Hyun-Suk;Lee, Yun-Hee;Kim, Hyun-Soo;Kang, Byung-Sam;Son, Jin-Hyun;Min, Jung-Hwan;Lyu, Kwang-Yeul
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.99-110
    • /
    • 2013
  • In the medical field, the necessity of education growth for the professional Radiation Technologists has been emphasized to become experts on radiation and the radiation field is important of the society. Also, in hospitals and companies, important on thesis is getting higher in order to active and cope with rapidly changing internal and external environment and a more in-depth expert training, the necessity of new teaching and learning model that can cope with changes in a more proactive has become. Thesis writing classes brought limits to the in-depth learning as to start a semester and rely on only specific programs besides, inevitable on passive participation. In addition, it does not have a variety opportunity to present, an actual opportunity that can be written and discussed does not provide much caused by instructor-led classes. As well as, it has had a direct impact on the quality of the thesis, furthermore, having the opportunity to participate in various conferences showed the limitations. In order to solve these problems, in this study, writing thesis has organized training operations as a consistent gradual deepening of learning, at the same time, the operational idea was proposed based on the connectivity integrated operating and effective training program & instructional tool for improving the ability to perform the written actual thesis. The development of teaching and learning model consisted of 4 system modeling, scaffolding, articulation, exploration. Depending on the nature of the course, consisting team following the personal interest and the topic allow for connection subject, based on this, promote research capacity through a step-by-step evaluation and feedback and, fundamentally strengthen problem-solving skills through the journal studies, help not only solving the real-time problem by taking wiki-space but also efficient use of time, increase the quality of the thesis by activating cooperation through mentoring, as a result, it was to promote a positive partnership with the academic. Support system in three stages planning subject, progress & writing, writing thesis & presentation and based on cognitive apprenticeship. The ongoing Coaching and Reflection of professor and expert was applied in order to maintain these activities smoothly. The results of this study will introduce actively, voluntarily and substantially join to learners, by doing so, culture the enhancement of creativity, originality and the ability to co-work and by enhance the expertise of based-knowledge, it is considered to be help to improve the comprehensive ability.

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF

Radioprotective Effect of Red Ginseng in Irradiated Mice with ${\gamma}$-ray (생쥐에서 홍삼의 감마선조사에 의한 방어효과)

  • Seung, Ka-Yeon;Lee, Heung-Man;Kim, Jong-Sang;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.31-35
    • /
    • 2010
  • Recently, the incidents of direct or indirect radiation exposure due to increase of use of radiation or radioisotope are on the increase in medical and industrial circles. If cells are irradiated, free radicals are created through biological process, and cells are directly or indirectly damaged. This research intends to explore into the effect of saponin at the level of cell (in vitro) and entity (in vivo), using red ginseng extract "saponin", as radioprotective agent. In the experiment implemented at the level of cell (in vitro), degree of cell activity was measures by adding mouse mesenchymal stem cells "C3H/10T1/2 cells" into red ginseng extract "saponin(0, 0.05, 0.2, and 0.4 g/L)", and then the optimal concentration of saponin influencing cells was calculated, in 24, 48, 72, and 96 hours after gamma irradiation at the optimal concentration of saponin, each cell survival rate was observed through XTT assay. The best time period of cultivation for the optimal activity of C3H/10T1/2 cells was as 48 hours, and the degree of optimal activity was shown at 0.05 g/L. In 48 hours after irradiation of 5 Gy to C3H/10T1/2 cells at 0.05 g/L, the degree of activity of cells increased by 10%. In the experiment implemented at the level of entity (in vivo), red ginseng extract "saponin" at a dose of 100 mg/kg/day was injected into the abdominal cavity of six-week immature mouse for two weeks. Right after the last abdominal injection, total body irradiation of gamma rays was carried out at a dose of 5 Gy and 10 Gy. And after irradiation, the blood sample was taken, and then the number of red corpuscles was counted. In result, the decrement of experimental group treated with red ginseng extract "saponin" was 2.3 times larger than that of control group. In view of the results so far achieved, it was revealed that red ginseng extract "saponin" has a radiation exposure protection effect in the experiment implemented at the level of cell (in vitro). In case of animal experiment, the decrement of number of red corpuscles decreased. Finally, it is necessary to carry out more various researches continuously.

Optimization of Protocol for Injection of Iodinated Contrast Medium in Pediatric Thoracic CT Examination (소아 흉부 CT검사에서 조영제 주입에 관한 프로토콜의 최적화)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.879-887
    • /
    • 2019
  • The purpose of this study is to establish a physiological injection protocol according to body weight, in order to minimize amount of contrast medium and optimize contrast enhancement in pediatric patients performing thoracic CT examinations. The 80 pediatric patients under the age of 10 were studied. Intravenous contrast material containing 300 mgI/ml was used. The group A injected with a capacity of 1.5 times its weight, and groups B, C and D added 5 to 15 ml of normal saline with a 10% decrease in each. The physiologic model which can be calculated by weight about amount of injection of contrast medium and normal saline, flow rate and delay time were applied. To assess image quality, measured average HU value and SNR of superior vena cava, pulmonary artery, ascending and descending aorta, right and left atrium, right and left ventricle. CT numbers of subclavian vein and superior vena cava were compared to identify the effects of reducing artifacts due to normal saline. Comparing SNR according to the contrast medium injection protocol, significant differences were found in superior vena cava and pulmonary artery, descending aorta, right and left ventricle, and CT numbers showed significant differences in all organs. In particular, B group with a 10% decrease in contrast medium and an additional injection of saline showed a low degree of contrast enhancement in groups with a decrease of more than 20%. In addition, the group injected with normal saline greatly reduced contrast enhancement of subclavian vein and superior vena cava, and the beam hardening artifact by contrast medium was significantly attenuated. In conclusion, the application of physiological protocol for injection of contrast medium in pediatric thoracic CT examinations was able to reduce artifacts by contrast medium, prevent unnecessary use of contrast medium and improve the effect of contrast enhancement.

Severe Pneumonia Caused by 2009 Pandemic Influenza A (H1N1) Virus in Children and Corticosteroid Treatment (소아에서 2009 신종 인플루엔자 A (H1N1) 중증 폐렴과 스테로이드 치료)

  • Sohn, Yu Rak;Kim, Jong Hee;Ma, Sang Hyuk;Lee, Kyung Yil;Kang, Jin Han
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.2
    • /
    • pp.193-200
    • /
    • 2011
  • Purpose : The effect of corticosteroid on severe pneumonia caused by 2009 pandemic influenza (H1N1) A virus is controversial. This study was aimed to present the effects of early, short-term corticosteroid treatment for severe pneumonia with this virus infection. Methods : A retrospective analysis was performed on severe pneumonia patients (37 patients) who had severe respiratory distress at presentation requiring oxygen therapy and received intravenous methylprednisolone (MP, 8-10 mg/kg, divided in 4 doses/day for 2-3 days) with oseltamivir. The clinical and laboratory characteristics of the patients were evaluated through the medical records and chest radiographic findings. Results : The mean age and male-to-female ratio of the patients were 6.5${\pm}$2.9 years of age, and 3.4:1 (male 29 patients), respectively. The 5-9 aged group was predominant among the age groups (25 patients, 67.6%). Duration of fever prior to admission was 1.4${\pm}$0.6 days and dyspnea developed within 24 h after beginning of respiratory symptoms in all patients. All patients were previously healthy and received oseltamivir within 48 h. Thirteen patients (35.1%) developed dyspnea during oseltamivir treatment. Following MP infusion, all 37 patients including 13 progressive pneumonia patients during oseltamivir treatment showed an immediate halt in the progression of pneumonic infiltration with rapid clinical improvement. There were no side-effects following steroid use. Conclusion : For severe pneumonia patients, early corticosteroid treatment halted clinical exacerbation, and possibly prevented progression to acute respiratory distress syndrome. Further controlled clinical studies are needed for the role of corticosteroids and antivirals on severely affected patients with influenza virus infections.

Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF

The Effect of Spiritual Nursing Intervention on Anxiety of the Hospice Patients (영적 간호중재가 호스피스 환자의 불안에 미치는 효과)

  • Yoon, Mae-Ok
    • Journal of Hospice and Palliative Care
    • /
    • v.4 no.1
    • /
    • pp.47-56
    • /
    • 2001
  • Purpose : Surveying the effects on drop the anxiety of the hospice patients in spiritual nursing intervention with a quasi-experimental design using non-equivalent contrast group non-synchronized design to try in order to give the support which provide a holistic and individualizational nursing to comfort of hospice patients. Method : The results of survey were collected from 67 patients(67 subjects comprised 37 hospice patients of the experimental group and 30s of contrast) who were given hospice care from July to September of 2000 at the General Hospital in Cheon Ju city. The tool was used Spielberger's State Anxiety Scale, and the difference in the level of dropping anxiety among patient groups was analyzed with the mean, standard deviation, $x^2-test$. t-test and paired t-test. The spiritual nursing intervention was carried out through Hymn, Scripture, prayer, the therapeutic use of self over a period of three weeks. Results : 1) In general characters, men were a many more of the objects and the average age of the experimental and contrast group was 59.6, 55.9 respectively. The family of living together was $2{\sim}3$ members of most part. 2) There were not significant differences in the general, disease and therapeutic, religional characters between the experimental and contrast group. 3) The majority of the objects were cancer patients in disease and therapeutic characters(Experimental : 92%, Contrast : 95%). 4) After the spiritual nursing intervention state anxiety of the experimental group were remarkably lower than those of the contrast (t=-5.987, P=0.000). 5) Decreasing rate in the anxiety scores of before and post facto of the experimental group were remarkably lower than those of the contrast (t=6.237, P=0.000). Conclusion : The hospice patients who were offered spiritual nursing intervention became much lower than those who were not offered it in anxiety. Spiritual nursing intervention can be suited to field with one program of an effective that that relieved their anxieties. It is not only a very short time but has quite a little findings in part of spiritual nursing intervention. Therefore, further study in this field is necessary to concrete and substantial investigate in order to more and more increasing hospice patients in 21st century.

  • PDF

Womans experience of Risk Situation on the High-Risk Pregnancy (여성의 고위험 임신에 대한 경험)

  • Kim, Kyung-Won;Lee, Kyung-Hye
    • Women's Health Nursing
    • /
    • v.4 no.1
    • /
    • pp.161-178
    • /
    • 1998
  • In spite of the great progress of the theory and skill of the Nursing Care & Medical area in relation to pregnancy, nurses in clinics face up to many challenges in maternity nursing care areas. The reason is that the mobility and mortality of mothers was sharply decreased and the unknown high-risk diseases of pregnancy woman in the past is made public. That's why it is difficult to meet the pregnancy woman in natural process from pregnancy to delivery in recently. Admission rooms are filled with high-risk pregnancy women. As a matter of fact, we have done nursing care into the surface symptoms and diseases of high-risk pregnancy women so far. We have been indifferent to a long period hospitalization, separation from family, and conflict of repeated examination. Therefore, it is widely spread to understand the emotional conflict experienced by high-risk pregnancy women and to need for nursing intervention to bring up about emotional support and the ability of perception in psychological crisis. Although the pregnancy woman judged in high-risk should carry out normal task of pregnancy, she have to be confronted with secondary risk situation. The health of self & fetus threatened by the risk situation could be decreased through care plan, but psychological stress increases. Therefore, the pregnancy brings into non-control state. It is important to ask that what the hospitalized pregnancy women in high-risk think of themselves status. Because misunderstanding or serious anxiety of themselves status put into mother and fetus in danger. And adaptation mode makes all the difference. I would like to consider how nurses could deal with this high-risk circumstances in the position of pregnancy woman on the basis of the above fact. This study uses phenomenological method to suggest the basis material for nurses to do nursing intervention in view of pregnancy woman. Because this method understands the nature of true life of pregnancy woman throughly. The phenomenological method is the sources to describe or explain affluently the process generated in confirmation areas and environment and is the application for readers to understand and recognize clinic reality and then apply this method to reasoning study place or other places. Specifically, the phenomenon study method, one of the phenomenological method, is applied. The use of that method is to describe and generalize the experience in environment exactly. The study of this study is as follows : Among 187 descriptive stamens from 8 study participants are classified into 42 theme cluster at the stage of the first analysis. Those theme is categorized into 8 sub-subjects such as anxiety of uncertainty, foreknowledge about risk circumstance, will power about overcome, unsettled feeling about hospital, relief, optimistic thought, family support, and indifferences. At the last stage of analysis, those things are categorized into 3 subjects. When high-risk pregnancy woman foretell the situation, they feel unsettlement about uncertainty and untrust feeling about hospital. But they are ease with family support and hospital support. On the other hand, they express indifferent 3-way structure response to the situation having will of overcome and exceeding optimistic thought. In those statements, the experience by pregnancy woman shows 3 respect subjects. 1. They are anxious of this situation and are in desperation and don't recognize their role to be carried out 2. They think of this situation as normal process of pregnancy and are not concerned that this can give themselves and fetus fatal damage. 3. The pregnancy women will never confront this situation. This study shows the pregnancy woman has anxiety and optimistic relief about the situation, and ignores and optimistic relief about the situation, and ignores many things. Therefore, nurses in clinic should give pregnancy woman knowledge and information about the high-risk and help them to deal with the situation spontaneously. High-risk pregnancy woman should have the care plan in respect of the right perception. And the nurse know that their support help out pregnancy woman overcome the crisis in this respect of the special nursing intervention.

  • PDF