• 제목/요약/키워드: Medical Ultrasound

검색결과 861건 처리시간 0.029초

Effect of Vibratory Stimulation on Recovery of Muscle function from Delayed Onset Muscle Soreness

  • Koh, Hyung-Woo;Kim, Cheol-Yong;Kim, Gye-Yoep;Kim, Kyung-Yoon;Kim, Soo-Geun;Lee, Hong-Gyun
    • 운동영양학회지
    • /
    • 제16권1호
    • /
    • pp.43-50
    • /
    • 2012
  • This study was designed to investigate the effect of vibratory stimulation on recovery of muscle function from delayed onset muscle soreness (DOMS). Volunteers performed 3 set of 70 % maximal voluntary eccentric muscle contraction and induced DOMS. volunteers were allocated to one of three treatment group after DOMS : group I (control), group II (ultrasound), group III (vibration). Maximal Voluntary Isometric Contraction (MVIC), Visual Analog Scale (VAS), Range Of Motion (ROM), Root Mean Square (RMS), Median frequency (MDF), Blood Serum Creatine Kinase (CK), Lactic dehydrogenase (LDH) were recorded at baseline, and 24, 48, 72 hours post-exercise. In MVIC measurement, there was a statistically significant difference in group III compared to group I (p < .05). In VAS measurements, there were a statistically significant difference in group II and III compared to group I (p < .05). In ROM measurement, there was a statistically difference in group II and III compared to group I (p < .05). In Muscle Volume with Ultrasonography measurement, there was no statistically significant difference in any groups (p > .05). In RMS and MDF measurement, there were a statistically significant difference in group II and III compared to group I (p < .05). In Blood samples of CK and LDH measurements, There were no statistically significant difference in any groups (p > .05). From the above result, Vibratory stimulation had a positive effect on recovery of muscle function from delayed onset muscle soreness. Further studies should be undertaken to ascertain the more effectiveness of vibratory stimulation and may be a promising treatment modality.

엎드려 무릎관절 굽힘 자세에서 엉덩관절 폄 동작 시 무게 부하 변화에 따른 큰볼기근과 넙다리두갈래근의 두께 비교 (A Comparison of Gluteus Maximus Muscle and Biceps Femoris Muscle Thickness According to Weight Load during Prone Hip Extension with Knee Flexion Exercises)

  • 장은미;정다은
    • PNF and Movement
    • /
    • 제21권3호
    • /
    • pp.309-317
    • /
    • 2023
  • Purpose: This study set out to investigate the effects of prone hip extension with knee flexion (PHEKF) exercises according to external load on the thickness of the gluteus maximus (Gmax) and biceps femoris (BF). Methods: Twenty-three healthy men participated in this study. All subjects randomly practiced PHEKF under the burden of external loads created by sandbags (0 kg, 1 kg, and 2 kg). Rehabilitative ultrasound imaging (RUSI) was used to measure the thickness of the Gmax and BF during the PHEKF with different external loads. Results: The thickness of the Gmax was highest during the 2 kg resistance exercise and lowest at 0 kg. The thickness of the Gmax was significantly increased at 1 kg and 2 kg compared to 0 kg and significantly increased at from 1 kg to 2 kg (p < 0.05). The thickness of the biceps femoris was highest at 0 kg and lowest at 2 kg. The thickness of the biceps femoris muscle was significantly reduced at 1 kg and 2 kg compared to 0 kg (p < 0.05), but there was no significant difference between 1 kg and 2 kg (p > 0.05). Conclusion: The thickness of the Gmax was increased by applying PHEKF with a higher external load, whereas the muscle thickness of the biceps femoris decreased. These results suggest that the application of external loads during PHEKF exercises may be an effective method for selective strengthening of the Gmax.

Concurrent Torsion of the Caudate Liver Lobe and Spleen in a German Shepherd Dog

  • Seong-won An;Seung-Min Hwang;Il-Gwon Jung;Sang-Kwon Lee;Young-Sam Kwon
    • 한국임상수의학회지
    • /
    • 제41권1호
    • /
    • pp.30-36
    • /
    • 2024
  • A 3-year-old, 20.6 kg, neutered male German Shepherd dog was referred to Kyungpook National University Veterinary Medicine Teaching Hospital. Clinical examination revealed chronic diarrhea for 6 weeks and a non-tender, distended abdomen without lethargy, anorexia, and vomiting. Diarrhea was watery and had a waxing and waning course despite symptomatic treatment. A complete blood count identified mild leukocytosis and mild anemia. Serum biochemistry analysis showed elevated alanine aminotransferase and aspartate aminotransferase levels, and mild hypoalbuminemia. Abdominal ultrasound examination revealed mixed echogenicity with absent blood flow at the caudate process of the caudate liver lobe and a small amount of ascites. Computed tomography revealed torsion of the caudate process of the caudate liver lobe and spleen and gas dilatation of the intestine. After establishing a diagnosis of organ torsion on imaging, we deemed the condition an emergency and immediately performed surgery. Given that laparotomy confirmed organ torsion, liver lobectomy, total splenectomy, and prophylactic gastropexy were conducted. The patient was discharged 11 days after surgery without complications. In general, liver lobe torsion and splenic torsion are uncommon in dogs and present with nonspecific clinical signs, such as abdominal pain, lethargy, anorexia, and vomiting. In the current case, torsion of the caudate liver lobe and spleen occurred without other clinical signs except for a distended abdomen. Moreover, no reports in dogs have demonstrated the simultaneous occurrence of both diseases.

Minimally Invasive Treatment for Benign Parathyroid Lesions: Treatment Efficacy and Safety Based on Nodule Characteristics

  • Eun Ju Ha;Jung Hwan Baek;Sun Mi Baek
    • Korean Journal of Radiology
    • /
    • 제21권12호
    • /
    • pp.1383-1392
    • /
    • 2020
  • Objective: This study aimed to evaluate the efficacy and safety of ultrasound (US)-guided minimally invasive treatment in patients with parathyroid lesions. Materials and Methods: This study included 27 patients who had undergone US-guided radiofrequency ablation (RFA) or ethanol ablation (EA) for parathyroid lesions between January 2010 and 2018. RFA was performed in 19 patients with primary hyperparathyroidism (PHPT, n = 11) or secondary hyperparathyroidism (SHPT, n = 8), and EA was performed in eight patients with symptomatic nonfunctioning parathyroid cysts (SNPCs). Nodule size, volume, serum parathyroid hormone (PTH) and calcium levels were recorded before and after treatment. Complications were evaluated during and after treatment. Results: In patients with PHPT, significant reductions in size and volume were noted after RFA at 6- and 12-month follow-up (all, p < 0.05). Seven nodules nearly completely disappeared (residual volume < 0.1 mL); serum PTH and calcium levels were reduced to normal ranges (7/11, 63.6%). Four patients experienced partial reductions of serum PTH and calcium levels (4/11, 36.4%). In patients with SHPT, three experienced therapeutic response of serum PTH (3/8, 37.5%), while five showed persistent hyperparathyroidism (5/8, 62.5%) within 6 months after RFA. In patients with SNPCs, EA resulted in significant reductions in cyst size and volume (all, p < 0.05) at the last follow-up. A total of four complications (two transient hypocalcemia [RFA], one permanent [RFA], and one transient [EA] hoarseness) were observed. Conclusion: Minimally invasive treatments, such as RFA and EA, may serve as therapeutic alternatives for patients with PHPT or SNPCs; they may have limited usefulness in patients with SHPT.

전방머리자세 대상자의 머리-척추각과 목 운동범위, 근력, 목빗근 두께와의 상관관계 분석 (Correlation Analysis between Cervical-Vertebra Angle and Neck Range of Motion, Muscle Strength, and Sternocleidomastoid Thickness)

  • 강민지;박근태;한진태
    • 대한물리치료과학회지
    • /
    • 제31권1호
    • /
    • pp.88-97
    • /
    • 2024
  • Background: This study was to investigate effects of Correlation Analysis between Cervical-Vertebra Angle and Neck Range of Motion, Muscle Strength, Sternocleidomastoid Thickness of Patients with Forward Head Posture Design: Correlation Analysis. Methods: The subjects of this study were a total of 54 people in the forward head position and their ages were between 30 and 50 years old. The subjects cranio-vertebral angles, neck extension, neck flexion, neck rotation angles, neck flexor strength, neck extensor strength, sternocleidomastoid thickness were evaluated through measuring instruments. The thickness of the sternocleidomastoid muscle was measured using an imaging ultrasound diagnostic device (ultra sound, Versana Premier, GE Medical systems, China). CVA was measured by measuring the side photo of the subject was taken with a camera and evaluated.. neck joint range of motion was measured through digital inclinometer for extension, flexion, and neck rotation. neck muscle strength was measured by measuring the using a digital sthenometer. Data analysis in this study was statistically processed using SPSS version 26.0 (IBM SPSS Inc., USA). Correlation analysis was used and the statistical significance level was set at 0.05. Results: The results neck extension(r= 0.70**), neck flexion(r= 0.67**), neck rotation(r= 0.56**), neck extensor muscle strengt(r= 0.85**), neck flexor muscle strength(r= 0.66**), sternocleidomastoid thicknes(r= -0.81**) It indicates that there is a correlation. Conclusion:These results improve the Cervical-vertebra angle of patients with forward head posture should include a program to improve the thickness of the SCM. In the future, study can be used as an evidentiary material for treatment interventions to improve the Cervical-vertebra angle of patients with forward head posture.

경동맥의 내막, 중막, 내중막 두께 분리측정 및 임상적 중요성 (Measurements of Carotid Intima, Media, and Intima-media Thickness and Their Clinical Importance)

  • 김원식;정환택;노기용;배장호
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.207-213
    • /
    • 2005
  • 경동맥 내중막 두께의 심각한 정도는 일과성 뇌 허혈, 중풍, 그리고 심근경색과 같은 관상동맥질환의 원인 질환이 되는 죽상동맥경화에 대한 독립적 예측인자이다 경동맥 내중막 두께는 내막두께와 중막두께로 구성되어 있지만, 내막과 중막 각각의 임상적 중요성에 대하여는 연구가 잘 되지 않고 있다. 본 연구에서는 죽상동맥경화증을 진단하기 위하여 B-mode 초음파 영상처리기술을 이용하여 내막, 중막, 그리고 내중막 두께를 측정하는 방법을 고안하였다. 내막, 중막, 내중막 두께의 임상적 중요성을 조사하기 위해서 144명(평균연령: 57세, 남성: 72명)의 환자를 대상으로 고해상도 초음파를 이용하여 총경동맥의 영상을 스캐닝 하였다. 그 결과, 죽상동맥경화성 질환이 있는 집단이 없는 집단에 비하여 내중막(p<0.01) 두께뿐만 아니라 내막(p<0.05) 및 중막(p<0.05)의 두께도 모두 유의하게 더 두꺼운 것으로 나타났다. 위험인자 중 고혈압이 있는 집단은 없는 집단에 비해 내막(p<0.01), 중막(p<0.001) 및 내중막(p<0.001) 두께 모두가 유의하게 더 두꺼웠고, 흡연을 하는 집단은 하지 않는 집단에 비해 내막의 두께만 유의하게 더 두꺼웠다(p<0.01). 내막(r=0.374, p=0.001), 중막(r=0.433, p=0.000) 및 내중막(r=0.479, p=0.000) 두께는 연령과 정적 상관관계(positive correlation)를 보였다. 두께들간의 공유설명량 ($r^2$) 평가결과는 내중막두께와 중막두께가 $92.4\%$, 내중막두께와 내막두께는 $49.1\%$, 그리고 내막두께와 중막두께는 $27.4\%$이었다. 이 결과는 경동맥의 내막과 중막은 서로 다른 생리현상을 갖는다는 것을 시사한다.

  • PDF

초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법 (Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System)

  • 정영관;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권1호
    • /
    • pp.49-60
    • /
    • 2002
  • 본 논문에서는 프레임율의 저하없이 개선된 해상도를 얻을 수 있는 동시 다중 송신집속 기법을 제안한다. 제안한 기법은 짧은 펄스를 사용하여 한 영역에 고정 송신 집속하는 기존의 방법과는 달리 여러 송신 집속점에 서로 독립적으로 집속된 쳐프 신호들을 동시에 송신한다. 수신된 신호는 정합 과정을 통하여 송신 집속 위치에 따라 각 쳐프 신호로 분리되고 짧은 펄스로 압축된다. 이렇게 압축되고 분리된 신호들은 각각 수신 동적 집속된 후 거리에 따라 집속 위치별로 선택되고 하나의 신호로 결합되어 개선된 측방향 해상도의 영상을 구성한다. 송신시 동시에 여러 위치에 초음파를 집속하고 수신시 이를 분리하기 위해서 사용된 터프 신호들은 주파수 대역에서 분할되어 서로 직교 특성을 갖도록 설계되었는데 변환자의 제한된 대역폭내에 많은 수의 의미있는 쳐프 신호를 설계하기 위해서 인접한 두 쳐프 신호의 주파수 대역 겹침을 허용하였다. 이때 대역 겹침으로 발생한 상호상관값의 상승을 억제하기 위해 인접한 두 쳐프 신호의 주파수 변화 방향을 엇갈리게 하는 밥법을 제안하였다. 특히 대역분할로 설계된 쳐프 신호중 낮은 주파수 성분의 신호를 변환자로부터 가까운 지역에 집속하고 높은 주파수 성분의 쳐프 신호를 먼 지역에 집속함으로써 깊이에 따라 영상의 해상도의 질을 일정하게 유지시켰다 더욱이 상관기를 이용한 정합 과정에서 신호가 압축되기 때문에 펄스 압축 기법에서 얻는 SNR를 증가시키는 이점이 있다 이때 상관기를 통한 압축 과정에서 쳐프 신호의 첨두값이 쳐프 신호의 길이에 따라 증가하기 때문에 깊이에 따를 높은 주파수 성분의 감쇄에도 불구하고 이렇게 높은 주파수 성분의 터프 신호를 깊은 지역에 사용할 수 있었다. 제안한 동시 다중 송신집속 기반의 시스템을 상관기의 위치에 따라 이상적인 구조와 현실적인 구조로 나타냈으며, 모사 실험을 통하여 기존의 펄스 집속 기법과 비교하여 그 성능을 검증하였다.hrough the medium. By digitizing the analog receiver outputs, and recording the signals for spectral analysis, surface wave velocities can be identified. Modifications to the SASW method includes the reduction of boundary reflections as adopted on the surface waves before the point where the reflected compression waves reach the receivers. In this study, the correlation between the surface wave velocity and the compressive strength of cement mortar is developed using one 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slab of 2,000 psi (140 kgf/$\textrm{cm}^2$) and two 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slabs of 3,000 psi (210 kgf/$\textrm{cm}^2$). public transportation, and availability of locally grown food were the important factors for deciding the place compared to those who had higher education. The price was the factor which

견갑하건 부착부의 제1부착면에 대한 초음파 소견의 기술적 연구 (Descriptive Study for Sonographic Morphology of the 1st Facet of Subscapularis Footprint)

  • 손훈상;위찬국;손민수
    • 대한정형외과학회지
    • /
    • 제54권4호
    • /
    • pp.343-352
    • /
    • 2019
  • 목적: 병변이 없는 견갑하건 부착부를 가진 환자를 대상으로 초음파를 통한 견갑하건의 부착부, 특히 제1부착면에 대한 초음파적 영상 소견 및 그 크기를 기술하고 인구통계적 특성과의 상관관계를 분석하고자 하였다. 대상 및 방법: 2015년 3월부터 2017년 12월까지 견갑하건 부착부에서 병변이 없는 것으로 확인된 시행된 115예(평균 연령 53.4세, 범위 23-74세)를 최종 평가대상으로 하여 후향적 분석을 시행하였다. 초음파를 통한 견갑하건의 부착부에 대한 검사상 가장 상부에 위치하면서 제2부착면 이하 부착면들과 뚜렷하게 구별되는 넓고 평편한 형태와 상방으로 향하고 있는 제1부착면을 확인하였으며 제1부착면의 상완골 간부의 축에 대한 횡축과 종축상의 길이를 측정하였다. 또한 각 예의 나이, 성별, 키, 체중, 체질량지수 및 팔 길이를 측정하였다. 결과: 초음파 검사를 통하여 측정된 견갑하건의 제1부착면의 평균 횡적 길이는 12.75 mm (범위 10.54-14.50 mm, 표준편차 0.712), 평균 종적 길이는 12.22 mm (범위 9.20-13.30 mm, 표준편차 0.888)였다. 성별간 견갑하건의 제1부착면의 크기는 횡적 길이와 종적 길이 모두에서 남성에서 유의하게 큰 것으로 확인되었다(p<0.001, p=0.001). 양성의 선형 상관관계를 보이는 키, 체중, 체질량지수, 팔 길이 요소들 중 견갑하건의 제1부착면의 종적 및 횡적 크기 모두에서 키와 가장 강한 양성 선형관계를 보였고(횡적 길이 r=0.749, p<0.001; 종적 길이 r=0.642, p<0.001), 체질량지수와는 약한 양성 선형관계를 보이는 것으로 분석되었다. 그 외 좌우 부위 및 나이는 제1부착면의 크기와의 통계적 유의성이나 선형 상관관계를 보이지는 않았다. 결론: 병변이 없는 견갑하건 부착부의 초음파적 영상 평가를 시행하여 그 부착부, 특히 가장 상부의 제1부착면의 구조적 및 형태적 특성을 확인할 수 있었다. 이는 견갑하건 파열에 대한 초음파 진단적 검사에 대한 해부학적 기초를 제공하게 될 것이다.

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.122-125
    • /
    • 2004
  • 폐, 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range 3 cm${\sim}$3 m), Computer(RS232C), Servo Motor (Torque 2.3 Kg)등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램 하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터 간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터 간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}$1% 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 2.34 ${\times}$ 10-4 초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정 간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정 간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}$1%이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34 ${\times}$ 10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

  • PDF

마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발 (Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle)

  • 김준태;주규태;차은종;김명미;정진형
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.394-402
    • /
    • 2021
  • 고령사회의 진입과 인간의 평균 수명이 연장되고, 여성의 사회적 진출 및 남성들의 외모에 대한 관심증가, 미디어 매체를 통한 K-문화가 전 세계적으로 관심을 받으면서 자연스럽게 관심은 K-Bueaty에 집중되고 있다. 최근, 의료관광 분야의 점유를 보면 성형 및 피부과와 같은 피부미용 의료관광의 경우 중국, 일본 등 아시아뿐만 아니라 북미, 유럽 등에서 인기를 누리고 있다. 사람의 노화를 가장 먼저 외면적으로 확인할 수 있는 부위는 바로 얼굴의 피부 주름이다. 깨끗하고 주름이 없으면서 탄력성 있는 건강한 피부는 대부분의 사람들이 원하는 바람이다. 대표적으로 집속형초음파자극(HIFU:High Intensity Focused Ultrasound)와 저주파, 고주파(RF:Radio Frequency), 미세전류를 이용한 갈바닉 테라피, 급속 냉각을 이용한 크라이오 테라피 등 피부의 컨디션과 상태에 따라 관리하는 방식이 달라지며, 같은 기전을 이용한 의료기기 및 피부미용 기기의 시술 역시 출력 및 자극 부위 등에 따라 시술의 효과가 차이가 난다. 본 연구는 수많은 피부미용 의료기기 및 미용기기 중 마이크로니들을 이용한 침습형 고주파 피부 의료기기를 개발하고자 국제규격인 IEC 60601-2(의료기기개별기준규격)및 MFDS(Ministry of Food and Drug Safety : 식품의약품안전처)에서 고시한 고주파 자극기 기준 규격을 준수한 고주파 출력 장치를 설계 및 개발하였다. 회로 설계는 Class-A Topology를 이용한 증폭장치(AMP:Amplifier)와 Half-Bridge Topology를 이용한 전원장치로 이루어져 있다. 개발된 고주파 출력 장치를 측정한 결과 평균 63.86%의 효율을 얻었으며, 최대출력은 116.7W, 50.67dBm으로 측정되었다.