• 제목/요약/키워드: Medical Ultrasound

검색결과 861건 처리시간 0.031초

2D Sparse Array Transducer Optimization for 3D Ultrasound Imaging

  • Choi, Jae Hoon;Park, Kwan Kyu
    • 비파괴검사학회지
    • /
    • 제34권6호
    • /
    • pp.441-446
    • /
    • 2014
  • A 3D ultrasound image is desired in many medical examinations. However, the implementation of a 2D array, which is needed for a 3D image, is challenging with respect to fabrication, interconnection and cabling. A 2D sparse array, which needs fewer elements than a dense array, is a realistic way to achieve 3D images. Because the number of ways the elements can be placed in an array is extremely large, a method for optimizing the array configuration is needed. Previous research placed the target point far from the transducer array, making it impossible to optimize the array in the operating range. In our study, we focused on optimizing a 2D sparse array transducer for 3D imaging by using a simulated annealing method. We compared the far-field optimization method with the near-field optimization method by analyzing a point-spread function (PSF). The resolution of the optimized sparse array is comparable to that of the dense array.

Application of Dual-Frequency Ultrasound for Treating the Ulcerative Necrobiosis Lipoidica

  • Hong, Seok Won;Park, Eun Soo;Kim, Seok Hwan;Jung, Min Jung
    • Medical Lasers
    • /
    • 제8권2호
    • /
    • pp.80-83
    • /
    • 2019
  • Necrobiosis lipoidica (NL) is a rare, idiopathic, chronic granulomatous inflammatory disease of collagen degeneration with the risk of ulceration. Many procedures have been proposed to treat this rare disease. In this study, we applied LDM®-MED for the management of NL, and this condition in our patient was chronic and refractory to other therapeutic options. To the best of our knowledge, no study has explored treatment of NL using ultrasound. Our results suggest that application of LDM®-MED seems to be an effective treatment option for NL. Long-term and systematic studies are needed to determine whether such application of LDM®-MED will be an innovative and effective treatment option for NL and various kinds of chronic wounds.

Breast Ultrasound Microvascular Imaging and Radiogenomics

  • Ah Young Park;Bo Kyoung Seo;Mi-Ryung Han
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.677-687
    • /
    • 2021
  • Microvascular ultrasound (US) techniques are advanced Doppler techniques that provide high sensitivity and spatial resolution for detailed visualization of low-flow vessels. Microvascular US imaging can be applied to breast lesion evaluation with or without US contrast agents. Microvascular US imaging without a contrast agent uses a sophisticated wall filtering system to selectively obtain low-flow Doppler signals from overlapped artifacts. Microvascular US imaging with second-generation contrast agents amplifies flow signals and makes them last longer, which facilitates hemodynamic evaluation of breast lesions. In this review article, we will introduce various microvascular US techniques, explain their clinical applications in breast cancer diagnosis and radiologic-histopathologic correlation, and provide a summary of a recent radiogenomic study using microvascular US.

Nipple Ultrasound: A Pictorial Essay

  • Angelica Chiorean;Roxana Maria Pintican;Madalina Szep;Diana Feier;Liliana Rogojan;Bogdan Fetica;George Dindelegan;Bura Vlad;Magdalena Duma
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.955-966
    • /
    • 2020
  • Ultrasound (US) is an attractive diagnostic approach to identify both common and uncommon nipple pathologies, such as duct ectasia, nipple abscess, nipple leiomyoma, nipple adenoma, fibroepithelial polyp, ductal carcinoma in situ (restricted to nipple), invasive carcinoma, and Paget's disease. US is the reliable first-line imaging technique to assess nipple pathologies. It is useful to identify and characterize nipple lesions. Additionally, we have presented the mammography and MRI outcomes correlated with histopathologic features for the relevant cases.

유방 병변에 대한 초음파 유도하 중재 시술 (Ultrasound-Guided Intervention for Breast Lesions)

  • 고은영
    • 대한영상의학회지
    • /
    • 제84권2호
    • /
    • pp.332-344
    • /
    • 2023
  • 비촉지성 유방 병변의 발견이 늘어나고 유방암에서도 유방 보존 수술이나 선행항암화학요법이 증가하면서, 유방 병변의 진단과 처치에 있어서 초음파 유도하 중재 시술은 갈수록 그 역할이 중요해지고 이용이 늘어나고 있다. 본 종설에서는 유방 초음파 유도하 중재 시술 중 가장 많이 쓰이는 조직검사와 조직 마커 삽입, 수술 전 위치결정술에 대해 종류와 시술 방법, 적응증, 장단점 등을 알아보고 실제 진료 현장에서 시행하는 데에 도움을 주고자 한다.

실시간 초음파 영상에서 노이즈 개선을 위한 GPU 기반의 필터 알고리즘 (A GPU-based Filter Algorithm for Noise Improvement in Realtime Ultrasound Images)

  • 조영복;우성희
    • 디지털콘텐츠학회 논문지
    • /
    • 제19권6호
    • /
    • pp.1207-1212
    • /
    • 2018
  • 초음파 영상은 초음파 펄스를 이용해 반사파를 수신하여 진단에 필요한 영상을 구성하는데 신호가 약해 질 경우, 잡음이 발생하여 미세한 명암도 차이가 발생한다. 또한 초음파 영상의 특성인 호흡에 의한 흔들림 현상과 실시간으로 변화하는 움직임에서 영상의 밝기 변화가 발생한다. 이와 같은 노이즈로 인해 임상적 병변을 육안으로 판단하고 진단하는데 어려움이 있다. 본 논문에서는 초음파 획득한 이미지에 영상처리 기법을 이용하여 형태학적 특징을 자동 추출한다. 이 논문에서는 영상처리를 위해 클라우드 빅데이터 처리 플랫폼을 활용해 GPU기반의 빠른 필터를 구현하였다. GPU 기반의 고성능 필터의 적용시 CPU 기반보다 4.7배 빠른 성능으로 알고리즘이 동작되었고 PSNR이 37.2dB로 원본과 매우 유사함을 확인하였다.

초음파 치료의 효율성 향상을 위한 초음파 온열 시뮬레이터 개발 (The Development of Ultrasonic Hyperthermia Simulator to Improve the Efficiency of Ultrasonic Therapy)

  • 유우진;노시철;정동환;박재현;최민주;최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권5호
    • /
    • pp.418-427
    • /
    • 2009
  • As many people are westernizing their life style and food consumption habits, a number of patients who have malignant tumors which grow very rapidly and hazardously destroy the human body are increasing. Ultrasonic hyperthermia is not only one of the tumor treatment methods which employs the non-radioactive ultrasonic waves to increase the temperature at the tumor region up to $40\sim45^{\circ}C$ to destroy and suppress tumor cells but also has been proved by many studies. Due to the rapid development of High Intensity Focused Ultrasound(HIFU), the ultrasound hyperthemia extensively boosts its applications in clinical field. For those reasons, Computed simulation factor should be needed before inspection to patients. To prove efficiency of ultrasonic hyperthermia, precise acoustic field measurement considering tissue characteristics and a heating experiment with tissue mimicking material phantom were conducted for effectiveness of simulation program. Finally, in this study, the computer simulation program verified the anticipated temperature effects induced by ultrasound hyperthermia. In the near future, it is hoped that this simulation program could be utilized to improve the efficiency of ultrasound hyperthermia.

집속 초음파 뇌 질환 치료를 위한 두부 유사 팬텀의 개발 (Development of Human-Head-Mimicking Phantom for Brain Treatment Using Focused Ultrasound)

  • 민정화;김주영;노시철;최흥호
    • 한국방사선학회논문지
    • /
    • 제7권6호
    • /
    • pp.433-439
    • /
    • 2013
  • 본 연구에서는 집속형 초음파를 이용하는 뇌 질환 치료의 연구를 위한 인체 두부 유사 팬텀을 개발하였다. 문헌 연구를 통하여 피부 조직, 두개골, 뇌 조직의 음향학적 및 물리적 특성을 조사하였으며 근사한 값을 가지는 적합한 각 조직 대체 물질을 제시하였다. 피부 조직의 경우 글리세롤 기반 연부 조직 유사 팬텀의 성분비를 조정하여 실제 조직과 유사한 음향학적 특성을 가지도록 하였으며 고분자 합성수지의 음향학적 특성을 측정하여 두개골 유사 물질로써의 적합성을 평가하였다. 뇌 조직은 투명한 egg white 팬텀을 이용하여 집속형 초음파의 가열 특성을 확인할 수 있도록 하였다. 또한 뇌 질환 치료 프로토콜 개발을 위한 시험 조사가 가능하도록 대체 물질들을 결합한 두부 유사 팬텀을 제작하였고 제작된 팬텀의 유효성 및 활용성 평가를 위해 초음파 조사 조건에 따른 팬텀의 변성을 관찰하였다.

Development of equipment for tumor cauterization

  • Hoshino, Hirokazu;Ochiai, Makoto;Sakasegawa, Aya;Hayakawa, Yoshinori
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.474-477
    • /
    • 2002
  • Equipment to cauterize tumors by an electrically heated Kanthal wire is under development. The wire( alloy of iron, chromium and Aluminum) keeps sufficient strength up to 1400 degrees in Celsius. Although AC 50Hz current source is used in the prototype experiment, RF current will be used in future. The diameter of the Kanthal wire was 0.3 mm which was connected to Kanthal wire of 0.8 mm. The thicker wire was used as a leading wire. The possibility of application of the heating wire in combination with an ultrasound endoscope was determined, where ultrasound endoscope is to be used to monitor the location on the wire and an extent of a tumor in digestive organs. This procedure requires the wire to be applied inside ultrasound transmitting media. First, the wire was applied in the degassed water in which a chicken liver sample was submerged. The wire, however, burned out in water soon after it became red-hot at 12 A. The reason is that large current is required for the wire to become red-hot due to strong convection. Starch paste of 3 weight percent was employed instead of water. This made the wire red-hot approximately at 6 A, showing the increased viscosity of the starch decreased the convection and the wire was cover by the steam. The liver sample was cauterized successively, while the location of the wire and the liver was monitored by an ultrasound diagnosis equipment outside the plastic vessel of the starch paste.

  • PDF

교통사고로 유발된 급성 경추통 환자의 경추 후관절에 시행한 초음파 유도하 치료군과 비유도 치료군의 소염 약침 치료 효과 비교: 후향적 관찰 연구 (Comparison of Ultrasound Guided Soyeom Pharmacopuncture Therapy Effect and Unguided Soyeom Pharmacopuncture Therapy Effect on Cervical Facet Joint of Acute Cervical Pain Patient Caused by Traffic Accidents: A Retrospective Study)

  • 양재은;오민석
    • 한방재활의학과학회지
    • /
    • 제32권3호
    • /
    • pp.109-117
    • /
    • 2022
  • Objectives To compare the therapeutic effect of ultrasound guided soyeom pharmacopuncture therapy and unguided soyeom pharmacopuncture therapy on cervical facet joint of patient who have cervical pain caused by traffic accidents. Methods The study was planned as a retrospective study that analyzes the patient's medical records. We analyzed medical records of 20 patients with acute cervical pain caused by traffic accidents from April 1, 2022 to May 31, 2022. 10 patients (Group A) were treated ultrasound guided soyeom pharmacopuncture therapy on cervical facet joint, 10 patients (Group B) were treated unguided soyeom pharmacopuncture therapy on cervical facet joint. We used visual analogue scale (VAS) and neck disability index (NDI) to evaluate improvements in cervical functions and pain, five point Likert scale to estimate patient's satisfaction. We used the IBM SPSS Statistics version 25 program (IBM Co., Armonk, NY, USA) for statistical analysis. Results Group A showed a significant decrease in the VAS on the 5th day of the soyeom pharmacopuncture therapy (p=0.001). However, there was no statistically significant difference of VAS between two groups (p=0.142). Group A showed significant decrease in the NDI on the 5th day of the therapy (p=0.002). Also, there was statistically significant difference on NDI between two groups (p=0.018). Difference of five point Likert scale between two groups was not statistically significant (p=0.407). Conclusions In patients of acute cervical pain caused by traffic accidents, ultrasound guided soyeom pharmacopuncture therapy on cervical facet joint showed significant efficacy on reduction of neck disability compared with unguided therapy.