• Title/Summary/Keyword: Medical Ultrasound

Search Result 822, Processing Time 0.023 seconds

Sensitivity Enhancement of Spirometer Employing Ultrasonic Method

  • Han, Seung-Heon;Kim, Young-Kil
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.6
    • /
    • pp.351-356
    • /
    • 2005
  • Respiration measurement method using an ultrasound sensor is influenced very little by an error of inertia and pressure. This device measures the amount and flow of respiration using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. This paper examines improving the sensor's sensitivity during transmission and receipt of the signal. Because the measurement must be performed on patients, clinicians need to be sure that it is accurately measuring even very weak breathing.

Fast Ultrasound Image Compression Based on Characteristics of Ultrasound Images (초음파 영상특성에 기반한 고속 초음파 영상압축)

  • Kim, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.70-71
    • /
    • 1998
  • In this paper, We proposed fast ultrasound image compression based on characteristics of ultrasound images. In the proposed method, wavelet transform is performed for non-zero coefficients selectively. It codes zero-tree symbols using conditional pdf (probability density function) as orientation of bands. It normalizes wavelet coefficients with threshold of each wavelet band and encodes those using a uniform quantizer. Experimental results show that the proposed method is the proposed method is superior in PSNR to LuraTech's method by about 1.0 dB, to JPEG by about 5.0 dB for $640\times480$ 24bits color ultrasound image.

  • PDF

A New Ultrasound Bladder Scanner to Estimate Urine Volume Using Hand-Motion Scan (손 동작 스캔을 이용한 잔뇨량 측정용 초음파 방광 스캐너)

  • Lee, Jung Hwan;Bae, Jung Ho;Lee, Soo Yeol;Cho, Min Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.4
    • /
    • pp.153-160
    • /
    • 2018
  • 3D ultrasound bladder scanners are getting popular in hospitals for the patients with bladder dysfunction. A current bladder scanner adopts a mechanical scan to acquire 3D images and requires two motors and complicated mechanical devices. In this paper, we propose a new ultrasound bladder scanner using hand-motion scan. Instead of two motors and mechanical devices, it has a motion sensor to record transducer positions during hand-motion scan. The experiments with a bladder phantom and volunteers showed similar measurement accuracy to a conventional 3D ultrasound bladder scanner. We expect that the proposed method will reduce the cost and size of the bladder scanner.

A Study on the Classification of Ultrasonic Liver Images Using Multi Texture Vectors and a Statistical Classifier (다중 거칠기 벡터와 통계적 분류기를 이용한 초음파 간 영상 분류에 관한 연구)

  • 정정원;김동윤
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.433-442
    • /
    • 1996
  • Since one texture property(i.e coarseness, orientation, regularity, granularity) for ultrasound liver ages was not sufficient enough to classify the characteristics of livers, we used multi texture vectors tracted from ultrasound liver images and a statistical classifier. Multi texture vectors are selected among the feature vectors of the normal liver, fat liver and cirrhosis images which have a good separability in those ultrasound liver images. The statistical classifier uses multi texture vectors as input vectors and classifies ultrasound liver images for each multi texture vector by the Bayes decision rule. Then the decision of the liver disease is made by choosing the maximum value from the averages of a posteriori probability for each multi texture vector In our simulation, we obtained higtler correct ratio than that of other methods using single feature vector, for the test set the correct ratio is 94% in the normal liver, 84% in the fat liver and 86% in the cirrhosis liver.

  • PDF

Fast Volume Visualization Techniques for Ultrasound Data

  • Kwon Koo-Joo;Shin Byeong-Seok
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.6-13
    • /
    • 2006
  • Ultrasound visualization is a typical diagnosis method to examine organs, soft tissues and fetus data. It is difficult to visualize ultrasound data because the quality of the data might be degraded by artifact and speckle noise, and gathered with non-linear sampling. Rendering speed is too slow since we can not use additional data structures or procedures in rendering stage. In this paper, we use several visualization methods for fast rendering of ultrasound data. First method, denoted as adaptive ray sampling, is to reduce the number of samples by adjusting sampling interval in empty space. Secondly, we use early ray termination scheme with sufficiently wide sampling interval and low threshold value of opacity during color compositing. Lastly, we use bilinear interpolation instead of trilinear interpolation for sampling in transparent region. We conclude that our method reduces the rendering time without loss of image quality in comparison to the conventional methods.

Comparative Efficacy of Four Imaging Instruments for Breast Cancer Screening

  • Mehnati, Parinaz;Tirtash, Maede Jafari
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6177-6186
    • /
    • 2015
  • Sensitivity and specificity are the two most important indicators in selection of medical imaging devices for cancer screening. Breast images taken by conventional or digital mammography, ultrasound, MRI and optical mammography were collected from 2,143,852 patients. They were then studied and compared for sensitivity and specificity results. Optical mammography had the highest sensitivity (p<0.001 and p<0.006) except with MRI. Digital mammography had the highest specificity for breast cancer imaging. A comparison of specificity between digital mammography and optical mammography was significant (p<0.021). If two or more breast diagnostic imaging tests are requested the overall sensitivity and specificity will increase. In this literature review study patients at high-risk of breast cancer were studied beside normal or sensitive women. The image modality performance of each breast test was compared for each.

Development of Ultrasound Sector B-Scanner(II)-Digital Scan Converter- (초음파 섹터 B-스캐너의 개발(II)-디지탈 스캔 컨버터-)

  • 김주한;김영모
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.133-138
    • /
    • 1986
  • Abstract In a conventional digital sector scan system in the ultrasound medical imaging, the sampling space is in the polar coordinates while the display space is in the cartesian coordinates, which necessitates a coordinate transformation process resultion process resulting the overall system very complex and bulky. In this paper we propose a new architecture of the Digital-Scan-Converter (DSC) for the ultrasound sector scan system in which sampling space is the same as the display space, so the data are displayed as they are acquired without any interpola- tion process required. To implement the above real time DSC. two frequency synthesizes with very high switching time and a low-pass filter are required. The former determines the precise location of the data points and the latter fills the gap betw- een pixels in the horizontal direction.

  • PDF

Clinical Experience of Countouring Fasciocutaneous Flap Using Ultrasound Assisted Liposuction (유리 근막 피판 수술 후 초음파 지방 흡입술을 이용한 피판 축소술의 임상경험)

  • Kim, Tae-Gon;Hong, Joon-Pio;Chung, Yoon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.12 no.2
    • /
    • pp.99-104
    • /
    • 2003
  • Liposuction is a useful method for debulking free flap. Recently, ultrasound assisted liposuction(UAL) has been reported to have many advantages over conventional suction-assisted lipectomy. We applied the UAL to debulk free fasciocutaneous flap of the forehead and lower extremities. The result was satisfactory and there was no significant complications worth noting. Although the cost can be expensive, it has many advantages such as less blood loss, larger amount of fat aspirate and better skin contraction. We can conclude that UAL can be a useful alternative method to debulk free fasciocutaneous flap.

  • PDF

A New Synthetic Aperture Technique Using Linear Wave Fronts (선형 파면을 이용한 새로운 합성구경 기법)

  • 장진호;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.321-330
    • /
    • 2001
  • In this paper, we propose a new synthetic aperture focusing scheme for improving the lateral resolution which is one of the most important factors determining the quality of ultrasound imaging. The proposed scheme enables full round-trip dynamic focusing with approximately limited property. This properties are obtained through transmitting plane waves of which the traveling angle varies with the receive subaperture position, as opposed to stepping the spherical wave source across an array in other synthetic aperture focusing schemes, and employing dynamic focusing in receive. In this paper, the properties of the proposed scheme is analyzed in which a hypothetical infinite line source is used to transmit the plane waves and verified through computer simulation results. Also, we show that the proposed scheme is realizable with an array transducer with a finite aperture size. In summary, it is shown through comparison between the field contours of the proposed scheme and the conventional scheme that the proposed scheme can improve greatly the lateral resolution of ultrasound imaging.

  • PDF