Influence of Four Types of Steering Assistive Devices on Driving Performance: Comparison of Normal and Disabled People with and without Driver's License (4가지 선회보조 장치가 운전 성능에 미치는 영향: 장애 유무와 운전면허 유무에 따른 비교)

  • Song, Jeongheon;Kim, Yongchul
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.32-42
    • /
    • 2017
  • The aim of this study was to evaluate driving performance of Healthy and disabled groups (with or without driver's license) to control steering wheel by using steering assistive devices in the driving simulator. The persons with partial loss of use of all four limbs have problems in operation of the motor vehicle because of functional loss to operate steering wheel. Therefore, if steering assistive devices for grasping the steering wheel are used to control the vehicle on the road in persons with disabilities, the disabled persons can improve mobility in their community life by driving a motor vehicle safely. Ten healthy subjects (with or w/o driver's license) and ten subjects with physical disabilities (with or w/o driver's license) were involved in this study to evaluate driving performance to operate steering wheel by using four types of steering assistive devices (Single-pin, V-grip, Palm-grip, Tri-pin) in driving simulator. STISim Drive 3 software was used to test the steering performance in four scenarios: straight road at low and high speed of vehicle (40 km/h and 80 km/h), curved road at low and high speed of vehicle (40 km/h and 80 km/h). This study used two-way ANOVA in order to compare the effects of two factors (type of steering assistive device and subject group) in the three dependent variables of driving performance (the lateral position of vehicle, standard deviation of lateral position representing the variation of the left and right movement of the vehicle and the number of line crossing). The mean values of the three dependent variables (lateral position, standard deviation of lateral position, the number of line crossing) of steering performance were statistically significantly smaller for the healthy or disabled groups with driver's license than the other groups without driver's license on the curved road at high speed of vehicle compared to low speed of vehicle.

Development of pulse diagnosis possible simulator using the stepper motor pumps (스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발)

  • Ryu, Geun-Taek;Woo, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.915-918
    • /
    • 2016
  • Virtual testing devices are required due to rapid changes in the health care industry and the increase of the medical or nursing workforce. The importance of devices such as the simulator, blood vessels, and lab equipment for modeling blood flow to the heart is increasing too. In this study, we made heart pump by using a step motor and developed device which simulates arterial, venous blood pressure, and blood flow. We finally evaluated the function of proposed device. The proposed system is composed of the pump for simulating, the valve device to describe the resistance of the artery and vein, and a reducing device showing the characteristics of the venous system. We used BOXER pump for heart simulator and silicon tube for arterial and venous vessels, and designed a reducing device. We also used the pressure sensor to measure arterial blood pressure. For the evaluation of the proposed system, we selected a range of 50~100mmHg of the blood circuit 60 per minute and then compared the blood pressure of a person and the measured blood pressure.

  • PDF

Deriving the Effective Atomic Number with a Dual-Energy Image Set Acquired by the Big Bore CT Simulator

  • Jung, Seongmoon;Kim, Bitbyeol;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.4
    • /
    • pp.171-177
    • /
    • 2020
  • Background: This study aims to determine the effective atomic number (Zeff) from dual-energy image sets obtained using a conventional computed tomography (CT) simulator. The estimated Zeff can be used for deriving the stopping power and material decomposition of CT images, thereby improving dose calculations in radiation therapy. Materials and Methods: An electron-density phantom was scanned using Philips Brilliance CT Big Bore at 80 and 140 kVp. The estimated Zeff values were compared with those obtained using the calibration phantom by applying the Rutherford, Schneider, and Joshi methods. The fitting parameters were optimized using the nonlinear least squares regression algorithm. The fitting curve and mass attenuation data were obtained from the National Institute of Standards and Technology. The fitting parameters obtained from stopping power and material decomposition of CT images, were validated by estimating the residual errors between the reference and calculated Zeff values. Next, the calculation accuracy of Zeff was evaluated by comparing the calculated values with the reference Zeff values of insert plugs. The exposure levels of patients under additional CT scanning at 80, 120, and 140 kVp were evaluated by measuring the weighted CT dose index (CTDIw). Results and Discussion: The residual errors of the fitting parameters were lower than 2%. The best and worst Zeff values were obtained using the Schneider and Joshi methods, respectively. The maximum differences between the reference and calculated values were 11.3% (for lung during inhalation), 4.7% (for adipose tissue), and 9.8% (for lung during inhalation) when applying the Rutherford, Schneider, and Joshi methods, respectively. Under dual-energy scanning (80 and 140 kVp), the patient exposure level was approximately twice that in general single-energy scanning (120 kVp). Conclusion: Zeff was calculated from two image sets scanned by conventional single-energy CT simulator. The results obtained using three different methods were compared. The Zeff calculation based on single-energy exhibited appropriate feasibility.

A Study on the Development of Medical Service Robot (의료용 서비스 로봇 개발에 관한 연구)

  • Kang, Sung-In;Park, Yoon-A;Oh, Am-Suk;Jean, Je-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.77-80
    • /
    • 2011
  • Medical robot has four fields. Surgery assistant robot, robotic surgery, Surgery Simulator, rehabilitation robot. Thus, medical robots is often high precision and reliability requirements for operations are being developed. Medical service robot's another sector is care for service robots. Care services robot is the hospital's reception work and biometric data acquisition of patients, the hospital in location and content information provide to patients. But now medical service robot practical acceptance process failed to progress. In this paper were the medical service robot systems design and implementation. Implemented the robot system is using the standard protocols for the exchange of medical information and can be linked with hospital information system. The hospital's patient reception and processing, to provide care waiting number information.

  • PDF

The Verification of Dosimetric Characteristics of the 3-D Compensator with the Exit Beam Dose Profile (Exit Beam Dose Profile을 이용한 3차원 보상체의 성능확인)

  • 이상훈;이병용;권수일;김종훈;장혜숙
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.3-17
    • /
    • 1996
  • Dose compensators have been widely used in radiotherapy fields. But, few reliable verification methods have been reported. We have developed the verification method for the evaluation of the effect of dose compensator using exit beam dose profile. The exit beam dose profiles were measured with and without dose compensator. For this purpose X-Omat V films and lead screened cassettes are used and dose distibutions are compared. Phantom data are collected using CT simulator(Picker, AcQ Sim) and compensator information can be obtained from Render Plan 3-D planning System. Aluminum Compensators are generated by computer controlled milling machine. The real dose distribution in the phantom and the exit beam dose profile can be obtained simultaneously with the films in the phantom and the opposite site of the beam. Dose compensations effects for oblique beam, parallel opposing beam and inhomogeneous human phantom can be obtained using above tools. And we could simate those effects with exit beam dose profile using the method that we have developed in this study.

  • PDF

B-COV:Bio-inspired Virtual Interaction for 3D Articulated Robotic Arm for Post-stroke Rehabilitation during Pandemic of COVID-19

  • Allehaibi, Khalid Hamid Salman;Basori, Ahmad Hoirul;Albaqami, Nasser Nammas
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.2
    • /
    • pp.110-119
    • /
    • 2021
  • The Coronavirus or COVID-19 is contagiousness virus that infected almost every single part of the world. This pandemic forced a major country did lockdown and stay at a home policy to reduce virus spread and the number of victims. Interactions between humans and robots form a popular subject of research worldwide. In medical robotics, the primary challenge is to implement natural interactions between robots and human users. Human communication consists of dynamic processes that involve joint attention and attracting each other. Coordinated care involves sharing among agents of behaviours, events, interests, and contexts in the world from time to time. The robotics arm is an expensive and complicated system because robot simulators are widely used instead of for rehabilitation purposes in medicine. Interaction in natural ways is necessary for disabled persons to work with the robot simulator. This article proposes a low-cost rehabilitation system by building an arm gesture tracking system based on a depth camera that can capture and interpret human gestures and use them as interactive commands for a robot simulator to perform specific tasks on the 3D block. The results show that the proposed system can help patients control the rotation and movement of the 3D arm using their hands. The pilot testing with healthy subjects yielded encouraging results. They could synchronize their actions with a 3D robotic arm to perform several repetitive tasks and exerting 19920 J of energy (kg.m2.S-2). The average of consumed energy mentioned before is in medium scale. Therefore, we relate this energy with rehabilitation performance as an initial stage and can be improved further with extra repetitive exercise to speed up the recovery process.

Design the Expert Systems for the Stroke Early Diagnosis based in Web Environment (Web환경기반의 뇌졸중 초기진단 전문가시스템 설계)

  • 이주원;정원근;박성록;이건기
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.269-272
    • /
    • 2002
  • In this study, we designed the expert system for the diagnosis of stroke. The causes of stroke in central nervous systems are very diverse, so a doctor who treats the patients with stroke must have the expert knowledge for the quick and correct diagnosis and for the adequate medical management. But the primary physician who engaged in the primary care of the patient with stroke does not have the export knowledge for the stroke. So, we need to develop the expert system for assisting the diagnosis of stroke. Also the diagnosis system can be used as simulator for the medical students who study the neurology. In this study, we developed the diagnosis expert system that offer a pathological name provided by artificial neural networks. And we designed the inference engine and interfaces. The artificial neural network is a system that provide a possible diagnosis of stroke. We implemented the system using Windows2000 Server, IIS5.0 and ASP.

  • PDF

Artificial Vision : Electrical Stimulation of the Visual Cortex (뇌세포의 전기자극에 의한 맹인의 시감각 회복에 관한 연구)

  • Cha, Ki-Chul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.28-30
    • /
    • 1991
  • A visual prosthesis for the blind based upon electrical stimulation of the visual cortex requires the development of an array of electrodes. To establish design specifications for such an electrode array, we have conducted psychophysical experiments with normally sighted subjects wearing a portable 'phosphene' simulator. The simulator consists of a small video camera, a monitor masked by an opaque perforated film, and optical lenses. The visual angle subtended by the masked monitor is $1.7^{\circ}$ or less. We measured visual acuity and reading rate as a function of the number of pixels and their spacing. Our results indicate that a phosphene image produced by 600 electrodes implanted in a $1\;cm^2$, area near the foveal projection on the visual cortex should provide a limited but useful visual sense for the profoundly blind.

  • PDF

Foot Strike Simulation by a Slider Type Mechanical Model (미끄럼형 기계적 모델에 의한 디딤동작의 시뮬레이션)

  • Park, Hae-Soo;Shon, Woong-Hee;Yoon, Yong-San
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.269-278
    • /
    • 1989
  • The initial impact at foot strike is produced by a slider type mechanical model, which can be measured using a force platform to evaluate various shoes. The lower extremity and foot motion was filmed by a 16mm high speed movie camera and several points on the rear half of the shoe and those near the trochanter and the lateral epicondyle were digitized to provide the linear and angular positions and velocities during impact. With these observed kinematics, a slider type foot strike simulator composed of guide rail and sliding dummy is designed. The simulator system makes the artificial foot of the dummy with running shoe on it to follow the foot strike motion. The dummy has the relevant mass-spring-damper system modeled after McMahon's. The motion of the model is drived by the gravity force and the generated motion alone with the ground reaction forces are monitored by the same procedures afore mentioned producing the initial foot strike impact similar to the onto observed in human gait.

  • PDF

Colonoscopy Training Simulator

  • Yi, S.Y.;Woo, H.S.;Kwon, J.Y.;Joo, J.K.;Lee, D.Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.57-61
    • /
    • 2005
  • This paper presents a new colonoscopy training simulator that includes a specialized haptic device and graphics algorithms to transfer haptic sensation through a long and flexible tube, and manage large number of polygons. The developed haptic device makes the colonoscope tube move along the two guiding rods in the translational direction. The torque of the roll motion is transferred by a timing belt and pulleys. A special guide is developed, which allows the force and torque from the motors to be transmitted to the user without loss. The haptic device is evaluated by physicians. One of the important skills of the colonoscopy, jiggling is incorporated for the first time by the developed sensor mechanism using photo-sensors. A colonoscope handle that shares the look, feel, and functions with the actual colonoscope, is developed with the necessary electronics inside. The number of polygons is reduced by an edge-collapse algorithm for real-time simulation. The algorithms to import CT data, to segment the colon image, to extract centerline of the colon, and to construct the colon surface, are integrated into a Colon Modeling Kit system that performs all these processes in real-time.

  • PDF