• Title/Summary/Keyword: Medical Simulator

Search Result 167, Processing Time 0.024 seconds

A Study on the Ride Film Appearing in Virtual Reality - the focus of Warrior of the Dawn - (가상현실에서 표출된 라이드필름 제작 사례연구 - Warrior of the Dawn 제작사례를 중심 -)

  • Kim, Tae-Hyung;Chung, Jean-Hun
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.9
    • /
    • pp.1204-1212
    • /
    • 2008
  • The vehicle simulation (flight simulator) in 1920's was the first in the virtual reality. With the development of precise optical and electromagnetic equipment, the virtual reality widened its application for other purposes than military one. Based on the realistic display technology, it is more and more common in the various areas such as entertainment, medical profession, learning, film, architectural design, tourism and etc. In 1989, Jaron Ranier was the first to use the terminology 'Virtual Reality'. With this term, all virtual projects could be classified in a single item. But even before the term was used, the virtual reality has been studied up to now. As a part of virtual reality, the human thirst for the impossible thing has led to the development of ride film. The ride film consists of the special technical elements as well as the psychological analysis of human being. The ultimate purpose of virtual reality is engrossment through interaction. Even though the real interaction requires interface, input sensor and reaction ability, the ride film is not an element of the typical interaction. The virtual reality is mostly defined in technical terms now. But in this study, we will analyze the concepts worked out by Professor Michael Haim who is called a philosopher in the cyberspace in aspect of experience-oriented definition. We will analyze the adaptability of virtual reality based on his concepts such as artificial reality/ interaction/ engrossment/ networked world/ remote display/ simulation/ onmon engrossment. And also, we aim to suggest the directions of developing the ride films for perfect engrossment and to draw optimized conclusion thereon. In this viewpoint, we consider that the study of ride film on which there were few case studies will contribute to level up the basic frameworks of IT technology and the digital image.

  • PDF

A Study on the Performance of Companding Algorithms for Digital Hearing Aid Users (디지털 보청기 사용자를 위한 압신 알고리즘의 성능 연구)

  • Hwang, Y.S.;Han, J.H.;Ji, Y.S.;Hong, S.H.;Lee, S.M.;Kim, D.W.;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.218-229
    • /
    • 2011
  • Companding algorithms have been used to enhance speech recognition in noise for cochlea implant users. The efficiency of using companding for digital hearing aid users is not yet validated. The purpose of this study is to evaluate the performance of the companding for digital hearing aid users in the various hearing loss cases. Using HeLPS, a hearing loss simulator, two different sensorinerual hearing loss conditions were simulated; mild gently sloping hearing loss(HL1) and moderate to steeply sloping hearing loss(HL2). In addition, a non-linear compression was simulated to compensate for hearing loss using national acoustic laboratories-non-linear version 1(NAL-NL1) in HeLPS. In companding, the following four different companding strategies were used changing Q values(q1, q2) of pre-filter(F filter) and post filter(G filter). Firstly, five IEEE sentences which were presented with speech-shaped noise at different SNRs(0, 5, 10, 15 dB) were processed by the companding. Secondly, the processed signals were applied to HeLPS. For comparison, signals which were not processed by companding were also applied to HeLPS. For the processed signals, log-likelihood ratio(LLR) and cepstral distance(CEP) were measured for evaluation of speech quality. Also, fourteen normal hearing listeners performed speech reception threshold(SRT) test for evaluation of speech intelligibility. As a result of this study, the processed signals with the companding and NAL-NL1 have performed better than that with only NAL-NL1 in the sensorineural hearing loss conditions. Moreover, the higher ratio of Q values showed better scores in LLR and CEP. In the SRT test, the processed signals with companding(SRT = -13.33 dB SPL) showed significantly better speech perception in noise than those processed using only NAL-NL1(SRT = -11.56 dB SPL).

The Effects of Trauma-patient Training Education Using Simulation on Knowledge, Satisfaction and Problem-solving in Emergency medical Students (시뮬레이션을 활용한 외상환자 실습교육이 응급구조학과 학생들의 지식과 만족도 및 문제해결에 미치는 효과)

  • Moon, Tae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.710-717
    • /
    • 2016
  • This study was progessed from March 3, 2015 to March 31 for purpose of evaluating the effects of the trauma-patient practice education using simulation on knowledge, satisfaction and problem-solving in paramedic students. To closely examine the adequacy of education for paramedic students in one university, a comparison was made by dividing 28 male and female students into two groups of experimental group with 14 students and control group with 14 students. The experimental group was carried out the practice education of the trauma-patient simulation using simulator. The control group was conducted the theoretical and practical education through a traditional instructor-led class. As a result of the research, the experimental group can be known to be significantly higher(t=2.09, p<.05) than the control group in the post-knowledge survey and satisfaction following the development in each educational method for 4 weeks. Also, in consequence of the variable-based correlation in the sub-factors of satisfaction, a correlation was shown between interest and clinical help or between interest and problem-solving ability(p<.05, p<.01). Based on the results of this study, it is considered that the simulation practice education in the emergency department is demanded and that the practice education will need to be continuously applied through developing a proper scenario.

A Study on the Implementation of the Multi-Process Structured ISDN Terminal Adaptor for Sending the Ultra Sound Medical Images (다중처리 구조를 갖는 초음파 의료영상 전송용 ISDN(Integrated Services Digital Network) TA(Terminal Adaptor) 구현에 관한 연구)

  • 남상규;이영후
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.317-324
    • /
    • 1994
  • This paper proposed a new method in the implementation of ISDN (integrated services digital network) LAPD (link access procedure on the D-channel) and LAPB (link access procedure on the B-channel) protocols. The proposed method in this paper implement ISDW LAPD protocol through multi-tasking operating system and adopt a kernel part that is changed operating system to target board. The features of implemented system are (1) the para.llel processing of the events generated at each layer, as follows (2) the supporting necessary timers for the implementation of ISDW LAPD protocol from the kernel part by using software, (3) the recommanded SAP (Service Access Point) from CCITT was composed by using port function in the operating system. With the proposed method, the protocols of ISDH layerl, layer2 and layer3 (call control) were implemented by using the kernel part and related tests were carried out by connecting the ISDH terminal simulator to ISDN S-interface system using the ISDN LAPD protocol The results showed that ISDW S-interface terminals could be discriminated by TEI (Terminal Equipment Identifier) assignment in layer 2 (LAPD) and the message transmission of layer 3 was verified by establishing the multi-frame transmission and then through the path established by the LAPD protocol, a user data was tranfered and received on B-channel with LAPB protocol Thererfore, as new efficient ISDN S-interface environment was implemented in the thesis, it was verified that the implemented system can be utilized by connecting ISDW in the future to transfer a medical image data.

  • PDF

Technical Review of Target Volume Delineation on the Posterior Fossa Tumor : An Optimal Head and Neck Position (후두와 종양의 방사선치료 시 표적용적의 결정을 위한 적절한 치료자세 연구)

  • Yoon Sang Min;Lee Sang-wook;Ahn Seung Do;Kim Jong Hoon;YE Byong Yong;Ra Young Shin;Kim Tae Hyung;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.94-99
    • /
    • 2003
  • Purpose : To explore a 3D conformal radiotherapy technique for a posterior fossa boost, and the potential advantages of a prone position for such radiotherapy. Materials and Methods :A CT simulator and 3D conformal radiotherapy Planning system was used for the posterior fossa boost treatment on a 13-year-old medulloblastoma patient. He was placed In the prone position and Immobilized with an aquaplast mask and immobilization mold. CT scans were obtained of the brain from the top of the skull to the lower neck, with IV contrast enhancement. The target volume and normal structures were delineated on each slice, with treatment planning peformed using non-coplanar conformal beams. Results : The CT scans, and treatment In the prone position, were peformed successfully. In the prone position, the definition of the target volume was made easier due to the well enhanced tentorium, In audition, the posterior fossa was located anteriorly, and with the greater choice of beam arrangements, more accurate treatment planning was possible as the primary beams were not obstructed by the treatment table. Conclusion : .A posterior fossa boost, in the prone position, Is feasible in cooperating patients, but further evaluation is needed to define the optimal and most comfortable treatment positions.

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

Two Stage CMOS Class E RF Power Amplifier (2단 CMOS Class E RF 전력증폭기)

  • 최혁환;김성우;임채성;오현숙;권태하
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.1
    • /
    • pp.114-121
    • /
    • 2003
  • In this paper, low voltage and two stage CMOS Class E RF power amplifier for ISM(Industrial/Scientific/Medical) Open Band is presented. The power amplifier operates at 2.4GHz frequency, and is designed and simulated with a 0.35um CMOS technology and HSPICE simulator. The power amplifier is simple structure of two stage Class E power amplifier. The design procedure determing matching network was presented. The power amplifier is composed of input stage matching network, preamplifier, interstage matching network, power amplifier, and output stage matching network. The matching networks of input stage and interstage were constituted by pi($\pi$) type and L type respectively. At 2.4GHz operating frequency, and with a 2.5V supply voltage, the power amplifier delivers 23dBm output power to a 50${\Omega}$ load with 39% power added efficiency(PAE).

S-FEAR: Secure-Fuzzy Energy Aware Routing Protocol for Wireless Sensor Networks

  • Almomani, Iman;Saadeh, Maha
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.4
    • /
    • pp.1436-1457
    • /
    • 2018
  • Secure routing services in Wireless Sensor Networks (WSNs) are essential, especially in mission critical fields such as the military and in medical applications. Additionally, they play a vital role in the current and future Internet of Things (IoT) services. Lightness and efficiency of a routing protocol are not the only requirements that guarantee success; security assurance also needs to be enforced. This paper proposes a Secure-Fuzzy Energy Aware Routing Protocol (S-FEAR) for WSNs. S-FEAR applies a security model to an existing energy efficient FEAR protocol. As part of this research, the S-FEAR protocol has been analyzed in terms of the communication and processing costs associated with building and applying this model, regardless of the security techniques used. Moreover, the Qualnet network simulator was used to implement both FEAR and S-FEAR after carefully selecting the following security techniques to achieve both authentication and data integrity: the Cipher Block Chaining-Message Authentication Code (CBC-MAC) and the Elliptic Curve Digital Signature Algorithm (ECDSA). The performance of both protocols was assessed in terms of complexity and energy consumption. The results reveal that achieving authentication and data integrity successfully excluded all attackers from the network topology regardless of the percentage of attackers. Consequently, the constructed topology is secure and thus, safe data transmission over the network is ensured. Simulation results show that using CBC-MAC for example, costs 0.00064% of network energy while ECDSA costs about 0.0091%. On the other hand, attacks cost the network about 4.7 times the cost of applying these techniques.

Korean Text Input System for Elderly using Grip Type Game Controller (그립형 게임 컨트롤러를 이용한 노인용 한글 입력 시스템)

  • Park, Sung-Jun;Lee, Ji-Won;Chang, Hee-Dong
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.94-102
    • /
    • 2009
  • As an advance in medical technology development is being made, and people are increasingly aware of the importance of health, related investments and people's average life expectancy rise, which in turn leads to an increase in elderly people. Also, with a growing number of elderly people enjoying their leisure activities, the utilization of multimedia contents using computers is on the increase, leading to an activated research into the establishment of digital culture for the elderly people. This paper proposes a Korean text input system to enable the elderly to utilize digital contents. Text input interface has conventionally depended on keyboards. However, the keyboard wherein many keys are dispersed creates problems for the elderly, such as a protracted recognition of keys and a lowered concentration when they use the keyboard. To address these problems, in this paper, the grip type controller interface for console games was used and a corresponding alphabet location algorithm was developed. To verify these efforts, a simulator was developed to test 20 elderly people; as a result, their satisfaction over and convenience of using the grip type interface increased.

A Human Sensibility Meter for Indoor Environmental Control Using Multiple Sensors (다중 센서를 이용한 실내 환경 제어용 감성 측정기)

  • Lee, Duk-Dong;Park, Kil-Heum;Choi, Doo-Hyun;Han, Dae-Hyun;Baek, Woon-Yi;Lim, Jeong-Ok;Hwang, Tae-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.327-333
    • /
    • 1998
  • A new human sensibility (kansei) meter that can measure human sensibility at the indoor environment is developed in this paper. Four sensors that can measure temperature, humidity, $CO_2$ and $C_4H_{10}$ concentrations are used. Among these sensors, the first three are used to determine the human sensibility. And the last to protect human from the harmful gas. First of all, human sensibilities are defined for each sensor datum, and then those are linearly combined to make a final human sensibility (kansei). The efficiency and usefulness of the meter are verified using a simulator on Windows 95 and a stand-alone system constructed using a microprocessor.

  • PDF