Accuracy of blood pressure measurements taken using a blood pressure simulator by paramedic students (응급구조(학)과 학생의 혈압측정 모형을 활용한 혈압측정 정확도)

  • Choi, Eun-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.1
    • /
    • pp.7-17
    • /
    • 2015
  • Purpose: We gathered information for the development of a blood pressure measurement education program by analyzing the accuracy of reading taken using a blood pressure simulator by Korean paramedic students. Methods: Data from 131 students were collected in November 12-20, 2013, and April 2-4, 2014. A 27-item questionnaire was administered, the accuracy of measurements confirmed using a blood pressure simulator (BT-CEAB), and the data analyzed (SPSS v 21.0). Results: The accuracy of systolic and diastolic blood pressure readings (${\leq}2mmHg$) was relatively low (27.5%). The mean blood pressure knowledge score was 67.61 points; significant differences were noted considering the sex (p = .001), hours of practice (p =.007), numbers of practice (p = .001), and reported self-confidence (p = .026). The blood pressure measurement accuracy group did not show a significant difference in its knowledge of blood pressure (p = .198). Conclusion: Most subjects needed several practice sessions to master the skill of measuring blood pressure. The feedback provided by individual assessment and the practice education program will serve as the basis for clinical and prehospital practice.

Preliminary Study on Performance Evaluation of a Stacking-structure Compton Camera by Using Compton Imaging Simulator (Compton Imaging Simulator를 이용한 다층 구조 컴프턴 카메라 성능평가 예비 연구)

  • Lee, Se-Hyung;Park, Sung-Ho;Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.51-61
    • /
    • 2009
  • A Compton camera, which is based on the geometrical interpretation of Compton scattering, is a very promising gamma-ray imaging device considering its several advantages over the conventional gamma-ray imaging devices: high imaging sensitivity, 3-D imaging capability from a fixed position, multi-tracing functionality, and almost no limitation in photon energy. In the present study, a Monte Carlo-based, user-friendly Compton imaging simulator was developed in the form of a graphical user interface (GUI) based on Geant4 and $MATLAB^{TM}$. The simulator was tested against the experimental result of the double-scattering Compton camera, which is under development at Hanyang University in Korea. The imaging resolution of the simulated Compton image well agreed with that of the measured image. The imaging sensitivity of the measured data was 2~3 times higher than that of the simulated data, which is due to the fact that the measured data contains the random coincidence events. The performance of a stacking-structure type Compton camera was evaluated by using the simulator. The result shows that the Compton camera shows its highest performance when it uses 4 layers of scatterer detectors.

  • PDF

An Exploration on the Use of Medical Simulation in Emergency Medical Technician Education (응급구조사 교육 분야에서 의료 시뮬레이션의 활용 방안 모색)

  • Kim, Jee-Hee
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.104-112
    • /
    • 2007
  • Simulators were introduced in education as a tool to make advanced training standardized, less expensive, and without danger to those involved. In 1922 in the Unites States, Edward Link presented his homemade flight simulator, which became common place in both military and civilian aviation, known as the "Link Trainer". The development of mannequin simulators used for medical simulation education, training, and research is reviewed, tracing the motivations, evolution to commercial availability, and efforts toward assessment of efficacy of those for teaching cardiopulmonary resuscitation(CPR) for medical personnel and emergency medical technicians(EMT), cardiology skills, anaesthesia clinical skills, and crisis management. This study will provide a brief overview of simulators and trainers in several domains.

Acceptance Test and Clinical Commissioning of CT Simulator

  • An, Hyun Joon;Son, Jaeman;Jin, Hyeongmin;Sung, Jiwon;Chun, Minsoo
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.160-166
    • /
    • 2019
  • This study examined the clinical use of two newly installed computed tomography (CT) simulators in the Department of Radiation Oncology. The accreditation procedure was performed by the Korean Institute for Accreditation of Medical Imaging. An Xi R/F dosimeter was used to measure the CT dose index for each plug of the CT dose index phantom. Image qualities such as the Hounsfield unit (HU) value of water, noise level, homogeneity, existence of artifacts, spatial resolution, contrast, and slice thickness were evaluated by scanning a CT performance phantom. All test items were evaluated as to whether they were within the required tolerance level. CT calibration curves-the relationship between CT number and relative electron density-were obtained for dose calculations in the treatment planning system. The positional accuracy of the lasers was also evaluated. The volume CT dose indices for the head phantom were 22.26 mGy and 23.70 mGy, and those for body phantom were 12.30 mGy and 12.99 mGy for the first and second CT simulators, respectively. HU accuracy, noise, and homogeneity for the first CT simulator were -0.2 HU, 4.9 HU, and 0.69 HU, respectively, while those for second CT simulator were 1.9 HU, 4.9 HU, and 0.70 HU, respectively. Five air-filled holes with a diameter of 1.00 mm were used for assessment of spatial resolution and a low contrast object with a diameter of 6.4 mm was clearly discernible by both CT scanners. Both CT simulators exhibited comparable performance and are acceptable for clinical use.

Evaluation of methods for estimating the pulse reflection site with cardiovascular simulator (심혈관계 시뮬레이터를 이용한 맥파 반사지점 추정방법들의 비교)

  • Lee, Ju-Yeon;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.19 no.1
    • /
    • pp.47-54
    • /
    • 2015
  • Objective Wave reflection is an important factor that determines the shape of the pulse wave. The purpose of this study is to compare the conventional method used for estimating the reflection site of pulse with a cardiovascular simulator. Methods: In this study, cardiovascular simulator with one elastic tube was used. The pressure and flow was measured simultaneously at three different points. The measured data were used to the conventional methods to estimate the pulse wave reflection site. The results were compared with the known length which were the distances from the measured points to the end of tube. Results & Conclusions: There is a significant error with the time domain method. While, the reflection site with the frequency domain method was similar to the actual reflection site.

The Study of Mechanical Simulation for Human Respiratory System (인체 호흡 모사를 위한 기계적 장치 연구)

  • Chi, S.H.;Lee, M.K.;Lee, T.S.;Choi, Y.S.;Oh, S.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.323-328
    • /
    • 2008
  • A patient with respiratory disorders such as a sleep apnea is increasing as the obese patient increase on the modern society. Positive Airway Pressure (PAP) devices are used in curing patient with respiratory disorders and turn out to be efficacious for patients of 75%. However, these devices are required for evaluating their performance to improve their performance by the mechanical breathing simulator. Recently, the mechanical breathing simulator was studied by the real time feedback control. However, the mechanical breathing simulator by an open loop control was specially required in order to analyze the effect of flow rate and pressure after operating the breathing auxiliary devices. Therefore the aims of this study were to make the mechanical breathing simulator by a piston motion and a valve function from the characteristic test of valve and motor, and to duplicate the flow rate and pressure profiles of some breathing patterns: normal and three disorder patterns. The mechanical simulator is composed cylinder, valve, ball screw and the motor. Also, the characteristic test of the motor and the valve were accomplished in order to define the relationship between the characteristics of simulator and the breathing profiles. Then, the flow rate and pressure profile of human breathing patterns were duplicated by the control of motor and valve. The result showed that the simulator reasonably duplicated the characteristics of human patterns: normal, obstructive sleep apnea (OSA), mild hypopnea with snore and mouth expiration patterns. However, we need to improve this simulator in detail and to validate this method for other patterns.

Performance Evaluation of the QoS Guarantee Mechanisms for Medical Multimedia Network Using DiffServ (DiffServ를 이용한 의료용 멀티미디어 네트워크의 QoS 보장에 대한 성능평가)

  • 이상학
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.12
    • /
    • pp.1505-1516
    • /
    • 2001
  • The goal of Medical multimedia server is to develop computer hardware and software which would enable electronic access, storage, transmission, and display of patient data and images. Since the current network only provides so called "best-effort" services, it is impossible to satisfy QoS guarantee that is required for real time application services for emergency room, operating room etc. Accordingly, world-wide research is being made for a variety of services to provide QoS. he goal of DiffServ is to offer scalable differentiated service in Internet which are made possible by traffic classification and conditioning only performed at an edge(or a boundary) node. In case DiffServ was deployed in the Medical multimedia network, it is difficult to estimate how the QoS mechanism would affect totally the network performance. Therefore, we need to verify by simulation the design of algorithm which provide a variety of differentiated services. In QoS for Medical multimedia network, a simulator is designed and implemented using OPNET to investigate the performance of DiffServ QoS support mechanism. The developed DiffServ simulator may generate packets according to random, and bursty traffic models in order to incorporate diverse traffic conditions in the Medical multimedia network environment. Based on our simulation results, we confirmed that service differentiation is possible by using the EF(Expedited Forwarding) class in DiffServ networks.

  • PDF

The Broad-beam CT Image Reconstruction from Simulator Images (모의치료(Simulation) 영상을 이용한 Broad-beam CT 영상 구현)

  • Yi, Byong-Yong
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.81-86
    • /
    • 1998
  • Purpose : To generate the axial, coronal and sagittal images from conventional simulation images, as a preliminary study of broad-beam simulator CT. Methods and Materials : Volumetric filtered back-projection was performed using 90 sheets of films from conventional simulator for every $4^{\circ}$ gantry angle. Two mAs exposure condition for 120kvp beam qualify at SFD 140cm was given to each film. Outside the silhouette portion was removed and scatter component was deconvolved before back-projection. Results : The axial, the sagittal and the coronal images with same spatial resolutions over all direction could be obtained. But image quality was very poor. Conclusion : CT images could be obtained using broad-beam. Scatter deconvolution technique was effective for this reconstruction. The fact that same spatial resolutions over all direction tells us the possibility of application of this technique to DRR or Simulator-CT. But the quality of image should be improved for clinical application practically.

  • PDF

Development of a Cardiovascular Simulator with Cardiovascular Characteristics (혈관계의 특성이 반영된 심혈관계 시뮬레이터의 개발)

  • Lee, Ju-Yeon;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.3
    • /
    • pp.33-40
    • /
    • 2012
  • Objectives: Existing cardiovascular simulators are used to evaluate artificial organs such as artificial hearts, prosthetic valves, and artificial blood vessels, and pulses are typically triggered using artificial hearts. However, the forms of pulse waves vary according to the location of arteries, and for precise assessment of artificial blood vessels, the development of simulators that generate diverse pressure pulse waves is necessary. This study developed a novel cardiovascular simulator that generates different forms of pulse waves. Methods: This simulator consists of a stepping motor, a slider-crank mechanism that transforms the rotation movement of a motor into the straight-line motion of a piston, a piston that generates pulsatile flows, a water tank that supplies fluids, an elastic tube made of silicon, and a device that adjusts the terminal resistance of fluids. Results & Conclusion: This study examined motor rotation and its operation under conditions similar to the physiological conditions of the heart. The simulator developed in this study produced diverse forms of waves, and the generated pressure waves well satisfied physiological conditions.