• Title/Summary/Keyword: Medical Instrument Design

Search Result 69, Processing Time 0.043 seconds

Process Design for Deep Drawing of High Precision Rectangular Battery Case used in Cellular Phone (휴대폰용 초정밀 사각 밧데리 케이스의 ???K드로잉 공정설계)

  • Kim H. J.;Ku T. W.;Kang B. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.10a
    • /
    • pp.97-100
    • /
    • 2000
  • Today deep drawing and ironing are the major process in manufacturing of battery case used in cellular phone from aluminum. The same technology is utilized in manufacturing of steel or aluminum cans for components of medical instrument, portable PC, walkman and so on. Most of these processes require multi-stage ironing following the deep drawing and redrawing processes. The practical aspects of this technology are well known and gained through extensive experiment and production know-how. However, the fundamental aspects of theses processes are relatively less known. Thus, it is expected that process simulations using FEM techniques would provide additional detailed information that could be utilized to improve the process condition. This paper illustrates the application of process modeling to deep drawing and redrawing operations for High Precision Rectangular Battery Case. A commercially avaliable finite element code LS-DYNA3D was used to simulate deep drawing and redrawing operations.

  • PDF

Development of Air-powered Handpiece for Surgical Operation (외과 수술용 Air-Powered Handpiece 개발)

  • 윤길상;이영훈;허영무;서태일;최길운
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.3
    • /
    • pp.188-193
    • /
    • 2004
  • The purpose of this paper is concerned with a development of an air-powered handpiece for surgical operation. The handpiece is the tool of surgical instruments and it can be used to interchange multiple attachments for drilling, pinning, sawing, driving screws and reaming. Most of domestic medical instruments bring in overseas and the air-powered handpiece imported from foreign countries at 100% too. Therefore we develop new air powered handpiece. we research in 2D and 3D modeling, design of air line, analyze structure. The air-powered handpiece composes of body, power supply air-line, elements for mechanical power transmission, attachment, and surgical tools. The handpiece is developed by several processes that 3D design, machining, heat treatment and coating. The developed handpiece is experimented to confirm check the efficiency.

Optical System Design for Real-Time 3-Dimension Ophthalmoscope (실시간 3차원 검안경의 광학설계)

  • Lee, Soak-Hee;Yang, Yun-Sik;Choe, Oh-Mok;Sim, Sang-Hyun;Doo, Ha-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • The display technology on the retina is the key role in inspecting the condition of the patients. 2-dimensional retina image is widely used in the eye examination as of today. Recently, 3-dimensional retina image ones have been introduced to this area, but the quality of the image is not fully satisfied to the operator. For the purpose of developing 3-D retina imaging instrument, the optimization of a 3-D retina imaging system using Code-V tool was investigated in this thesis. He-Ne laser having the wavelength 632.8 nm was used to make a power source to detect the retina. Several lenses and mirrors installed on sledge which were developed to perform focus control on 3-D device were designed to make a beam focusing and direct line. Polygon scanner having 24 mirror facets and galvanometer making tilting movement were utilized to make a 2-D laser plane. Also, design of eye ball had been fulfilled to see the focus of the 2-D plane. Reflected ray from retina detected on the sensor array with the same path. All cognitive components were optimized for aberration correction in order to focus on retina. Results of optimization were compared to those of initial designed optics system. On the basis of above results, the result of third aberration has been corrected to stable values to the optical system. MTF evaluating the resolution of an image has been closely correlated to the diffraction limit and PSF indicating the strength distribution of an image has shown the SR value as 0.9998 having high performance. The possibility of new and powerful 3-D retina image instrument was verified by simulating each component of the instrument by Code-V.

  • PDF

A Study on Nursing College Students' Knowledge and Attitudes toward Brain Death, Organ Donation and Organ Transplantation (뇌사와 장기기증 및 장기이식에 대한 간호학생의 지식과 태도 연구)

  • Kang Hee-Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.5 no.1
    • /
    • pp.7-19
    • /
    • 1999
  • The purpose of this study was to examine nursing college students' knowledge of and attitudes toward brain death, organ donation and organ transplantation. The research design utilized in this study was a descriptive research design. The data were collected from September 7 to 14, 1998, by means of strutted questionnaire. To measure students' knowledge of brain death, organ donation and organ transplantation, Joo's(1995) instrument was used. The questionnaire was composed of 22 items. To measure students' attitudes toward organ donation and organ transplantation, s(1995) Instrument was used. The questionnaire was composed of 22 items. The data were analyzed by frequency, t-test, ANOVA, and Pearson's Correlation Coefficient using the SAS program. The results were as follows : 1. Students' knowledge of brain death, organ donation and organ transplantation was 9-20. The mean score was 15.36, with 22, the highest possible score. There was statistically significant difference between students' knowledge and approval on the brain death recognition group(t=9.75, p=0.002). 2. Students' altitudes toward organ do nation and organ transplantation showed is mean score of 3.61 on a 5 attitudes points Liken scale. More than 80% of respondents agreed that organ transplantation can offer a high quality of life to the recipient and is an acceptable form of medical treatment. The health care costs associated with organ transplantation are worth itif another's life can be saved. Students felt it important to help others who are very ill. Also, by donating organs, students felt a part of their own body would continue to live by making it possible for someone else to live. Only 2.9% of students objected to organ donation for religious reasons. There was statistically significant difference among students' attitudes, experienced blood donor group(t=17.04, p=0.000), approval on the brain death recognition group (t=21.06, p=0.000), organ donation agreement group(t=46.13, p=0.000).

  • PDF

Incidence of postoperative pain after using single continuous, single reciprocating, and full sequence continuous rotary file system: a prospective randomized clinical trial

  • Umesh Kumar;Pragnesh Parmar;Ruchi Vashisht;Namita Tandon;Charan Kamal Kaur
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.2
    • /
    • pp.91-99
    • /
    • 2023
  • Background: Extrusion of debris is a major factor that results in postoperative pain during root canal treatment with various instruments and instrumentation techniques. Therefore, instrumentation techniques that extrude minimal debris into the periapical area while reducing pain are desirable. This study aimed to compare the incidence of postoperative pain and intake of analgesic medication (frequency and quantity) after endodontic treatment of mandibular posterior teeth using two single files and full-sequence continuous rotary systems with different kinematic motions. Methods: Thirty-five of 105 patients were assigned equally to three groups according to the instrumentation system used: ProTaper Next (PN) X2, 25/06 (Dentsply, Maillefer, Ballaigues, Switzerland), One Shape (OS), #0.25/06 (Micro Mega, Besancon, France), and Wave One Gold (WG), Red - #0.25, 0.07 (Dentsply, Maillefer, Ballaigues, Switzerland). Five specialists were included in this study design; each professional prepared 21 teeth, and randomly selected 7 per instrument system. The VAS sheet ranging from 0 to 10 was used to record the initial and postoperative pains at 24, 48, and 72 h, and 7th day after single visit endodontic treatment in mandibular premolars and molars with a diagnosis of asymptomatic irreversible pulpitis with or without apical periodontitis. Postoperatively, an analgesic, ibuprofen 400 mg was administered for intolerable pain at a dose of 1 tablet for 6 h. The patients were asked over the telephone regarding postoperative pain at intervals of 24, 48, and 72 h, and 7th day using a visual analogue scale. Result: There were no statistically significant differences among the PN, OS, and WG systems (P > 0.05) with regard to the incidence of postoperative pain at any of the four time points assessed. Conclusion: The intensity of postoperative pain, frequency, and analgesic intake were similar across all three types of instrument systems; however, the reciprocating single file (WG) was associated with less postoperative pain than the full sequence continuous rotary file.

Design of a customizable fluorescence detection system for fluorescently labeled tumor cells (형광 발현 암세포 탐지를 위한 맞춤형 검출시스템 개발)

  • Cho, Kyoungrae;Seo, Jeong-hyeok;Choe, Se-woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.3
    • /
    • pp.261-266
    • /
    • 2019
  • Flow cytometry is an electrical detection system that provides precise and diverse optical properties to cells and micro particles. Flow cytometry, which provides multidimensional information including cell size and granularity through light scattering and fluorescence emission generated by the induction of light of a specific wavelength to the fluorescently treated cells or micro particles, plays an important role in biomedical and biophysical fields. However, it has some drawbacks such as high cost, size of the instrument and limitation in selecting fluorescent dyes. Therefore, in this paper, a low cost compact fluorescent detection system is developed using light-emitting diode and microcontroller. The proposed fluorescence detection system has a replaceable the light source/fluorescence filter/photodetector and constructed by 3D printer, so that the user can design a customized system according to the selected fluorescent dyes. The fluorescence intensity was measured by varying the number of fluorescently labeled cells, and the measured intensities showed a high linearity within the tested concentration ranges.

Design for the Remote ECG Diagnosis System using LAN and MODEM (LAN 과 MODEM을 이용한 ECG 원격 진단 시스템 구현)

  • Ahn, S.H.;Yi, Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.171-175
    • /
    • 1997
  • We have developed a remote diagnosis system using the LAN and MODEM which enables a routine check for a patient remotely. We used $LabVIEW^{TM}$ as the programing development tool and DAQ (Data Aquisition) board from National Instrument for data aquisition. The LAN card and MODEM are used for the transmission of patient's data. A patient data are aquired by DAQ board and signal processing is done by $LabVIEW^{TM}$, which is a graphical prgamming language. Two methods for the data of transmission. One is the Client-Server model using TCP/IP (Transmission Control Protocol / Internet Address) in the LAN (Local Area Network) Another is using MODEM to transmit the measured data from a patient. In this case, the data transmission is accomplished by the FTP (File Transfer Protocol).

  • PDF

A STUDY ON THE SLIENT PERIOD MEASURING DEVICE OF MASSETER MUSCLE (교근의 휴지기 측정기기에 관한 연구)

  • Kim, Sung-Hwan;Han, Hyun-Bae;Suh, Hwal
    • The Journal of the Korean dental association
    • /
    • v.22 no.12 s.187
    • /
    • pp.1075-1082
    • /
    • 1984
  • The measurement of the silent period of Masseter muscle is very useful diagnostic method of TMJ syndrome. In this paper, we design a very convenient and very low-priced medical instrument for dental research which does not need gain control to each patient for measuring the silent period and the data processing time is very short.

  • PDF

Successive Suturing Mechanism For Gastrointestinal Endoscope (내시경용 연속스티치 메카니즘)

  • 전종진;홍대희;이규백;전훈제
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1328-1331
    • /
    • 2003
  • As rates of gastric cancer. fatness. and GERD (chronic gastric esophageal reflux disease) patients have been increased in the world, suturing mechanism using endoscope has been focused. which is the medical instrument to apply stitches and suturing inside the body, since it helps the patients lessen pains and reduce operation time. This paper deals with mechanism design, which makes it possible to apply multiple suturing without the repeat of inserting and removing the endoscope. This successive suture mechanism includes gripper, linkage, rotational part, and articulation part. Also, the mechanism is operated through 4mm one-side channel attached to the endoscope by means of pulling wires.

  • PDF

An Experimental Study on the design of the thermister thermometer (전기온도계 제작에 관한 실험적 연구)

  • Yun, Dork-Ro;Kim, Ik-Su
    • Journal of Preventive Medicine and Public Health
    • /
    • v.6 no.1
    • /
    • pp.65-70
    • /
    • 1973
  • The study in the fild of medical instrument has been out of the interest by any of the life scientist in Korea. Especially, the recent developments in the medical electromics are remarkable one. Authors planned this study to ascertain the possibility of setting up the thermister thermometer with available accessories of demestic prouducts including some specific foreign assembly parts. By proper use of the thermister as one of the wheatstone bridge, we could detect tile resistance variations due to the environmental temperature variace. The intensive care for the bridge circuit and compensation scheme was required. The calibration procedure adopted here makes it possible to read the current as the temperature. The temperature range was determined by the examination and construction of the graph of the resistance-temperature variation. The determination of electric current, available ambient-temperature, the reduction of excessive current and self-heating of the thermister were made. Renovation in response-velocity was under taken too. This electronic thermometer was designed and assembled by the circuitry developed in accordance with the maximum availability of domestic products with some foreign-made parts. The result of our experiment showed very stable function and proved to be the most promissing item in the actual application as long as the thermistor thermister is concerned.

  • PDF