• 제목/요약/키워드: Medical Information Standard Technology

Search Result 168, Processing Time 0.025 seconds

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

A Study on Analysis and Countermeasure of Security threat in NFC (NFC 서비스 보안 위협 분석 및 대응방안 연구)

  • Kim, Hyung-Uk;Kim, Hyung-joo;Kang, Jung-ho;Jun, Moon-seog
    • Journal of Digital Convergence
    • /
    • v.14 no.12
    • /
    • pp.183-191
    • /
    • 2016
  • Most recent trend reveals broader state of provision of NFC service as NFC technology was applied on smartphones which has become core communication tools by providing integrated services such as payment, medical, and personal authentication. Moreover, with integration of original service and NFC technology, new service providers now can handle personal information of original service or can handle other personal information with transition of previous service provider to NFC service provider. Considering current state of security industry along with NFC technology and service, we would like to analyze current stage of security threats and plan the counter strategies to create NFC service structure.

The Influence of Noise Environment upon Voice and Data Transmission in the RF-CBTC System

  • Kim, Min-Seok;Lee, Sang-Hyeok;Lee, Jong-Woo
    • International Journal of Railway
    • /
    • v.3 no.2
    • /
    • pp.39-45
    • /
    • 2010
  • The RF-CBTC (Radio Frequency-Communication Based Train Control) System is a communication system in railroad systems. The communication method of RF-CBTC system is the wireless between the wayside device and on-board device. The wayside device collects its location and speed from each train and transmits the distance from the forwarding train to the speed-limit position to it. The on-board device controlling device controls the speed optimum for the train. In the case of the RF-CBTC system used in Korea, transmission frequency is 2.4 [GHz]. It is the range of ISM(Industrial Scientific and Medical equipment) band and transmission of voice and data is performed by CDMA (Code Division Multiple Access) method. So noises are made in the AWGN (Additive White Gaussian Noise) and fading environment. Currently, the SNR (Signal to Noise Ratio) is about 20 [dB], so due to bit errors made by noises, transmission of reliable information to the train is not easy. Also, in the case that two tracks are put to a single direction, it is needed that two trains transmit reliable voice and data to a wayside device. But, by noises, it is not easy that just a train transmits reliable information. In this paper, we estimated the BER (Bit Error Rate) related to the SNR of voice and data transmission in the environment such as AWGN and fading from the RF-CBTC system using the CDMA method. Also, we supposed the SNR which is required to meet the BER standard for voice and data transmission. By increasing the processing gain that is a ratio of chip transmission to voice and data transmission, we made possible voice and data transmission from maximally two trains to a wayside device, and demonstrated it by using Matlab program.

  • PDF

A Study on the Design of DICOM Integration Engine in the Ubiquitous Computing Environments (유비쿼터스 컴퓨팅 환경에서의 DICOM 설계에 대한 연구)

  • Im, In-Chul;Ha, An-Rye;Kim, Chang-Soo;Hwang, In-Chul;Ok, Chi-Sang
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.307-315
    • /
    • 2005
  • In the ubiquitous computing environments, ICT industries of current society are developed in enormous growth. Medicine or patients with mobile devices can access at any time, any place. The medical procedures at the patient bedside are out of the scope of current systems, which means that patient record and image data access during the medical visit or the execution, recording and confirmation of the medicine prescriptions, still do not enjoy computerized support. Today, the exchange of medical images and clinical information is well defined by DICOM and HL7 standards. The DICOM independent terminal equipment image access system was developed in which a DICOM Engine acts as the gateway between a PACS DB and user's terminal. Implementation system is compatible with most currently available Integration system models. This paper presents a software technology where the medical and nursing staff will be equipped with any device connected by wire and wireless to a central server that provides access to the electronic patient records and that will actively inform about tasks pending distribution. The prototype described in this article implements a medical images and structured reports server that makes the search and recovery of data stored in the DICOM standard possible.

  • PDF

A Coexistence Mitigation Scheme in IEEE 802.15.4-based WBAN (IEEE 802.15.4 기반 WBAN의 공존 문제 완화 기법)

  • Choi, Jong-hyeon;Kim, Byoung-seon;Cho, Jin-sung
    • Journal of Internet Computing and Services
    • /
    • v.16 no.3
    • /
    • pp.1-11
    • /
    • 2015
  • WBAN(Wireless Body Area Network) operating around the human body aims at medical and non-medical service at the same time. and it is the short-range communication technology requiring low-power, various data rate and high reliability. Various studies is performing for IEEE 802.15.4, because IEEE 802.15.4 can provide high compatibility for operate WBAN among communication standard satisfiable these requirements. Meanwhile, in the case of coexisting many IEEE 802.15.4-based WBAN, signal interference and collision are the main cause that is decreasing data reliability. but IEEE 802.15.4 Standard does not consider about coexistence of many networks. so it needs improvement. In this paper, To solve about this problem, identify coexistence problem of IEEE 802.15.4-based WBAN by preliminary experiments. and propose a scheme to mitigate the reliability decrease at multiple coexistence WBAN. The proposed scheme can be classified in two steps. The first step is avoidance to collision on the CFP through improving data transmission. The second step is mitigation collision through converting channel access method. Proposed scheme is verified the performance by performing comparison experiment with Standard-based WBAN.

A Study on Blood Management System based on SIP for Ubiquitous Healthcare service (유비쿼터스 헬스케어 서비스를 위한 SIP 기반 혈액관리 시스템에 관한 연구)

  • Park, Yong-Min;Oh, Young-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.10B
    • /
    • pp.1222-1232
    • /
    • 2011
  • RFID/USN core technologies for ubiquitous computing, It is possible to use variety of sensors, direct processors, and wireless network technology that easily collect the actual physical environment and can monitor information remotely. Especially the healthcare industry and services combined with U-Healthcare that have international competitiveness in the medical field. But the USN, standard management system of RFID such as EPCglobal architecture framework, the lack of interoperability issues and the global sensor network implementation. In this paper, a system for managing sensor nodes of the USN, USN of SIP-based management system (UMS) is proposed. UMS support Session Initiation Protocol (SIP), provide session management and mobility capabilities, that is based on Internet standard protocol. UMS architecture of the existing SIP architecture, added USN User Agent (UUA) and the USN Name Server (UNS) that the location of sensor nodes should be possible to trace. UUA on behalf of the limited capacity of the location of the sensor nodes to perform the registration process, UNS to track the location of the sensor nodes to provide name resolution services. The proposed management system has the advantage of internet applications such as Web services interoperability and easy to recycle existing resources with other SIP-based because it uses the Internet standard protocol SIP. In this paper we propose is based on the UMS blood temperature management system is verified through the scenario.

Animal Skin Irritation and Skin Sensitization Tests of High Intensity Focused Ultrasound System Cartridges (집속형초음파자극시스템 카트리지의 동물실험을 통한 피부자극시험 및 피부 감작성시험)

  • Jun-tae, Kim;Ju-hee, Kim;Kyu-tai, Joo;Kyung-ah, Kim;Ahnryul, Choi;Jae-hyun, Jo;Jin-houng, Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.477-484
    • /
    • 2022
  • In this study, the cartridge part of the focused ultrasound stimulation system was used as a sample to conduct a skin irritation test and a skin sensitization test through animal experiments among the tests related to GLP (Good Laboratory Practice), a medical device safety evaluation standard. The test was conducted after IACUC approval using 6 female New Zeland White Rabbits. The polar and non-polar stimulation indices were all '0.0'. In addition, in the case of skin sensitization evaluation, 30 guinea pigs approved by IACUC were divided into control and experimental groups, and all induction and induction steps were applied using the eluate itself without separate dilution of the test sample and blank test solution. As a result of the experiment, the skin reaction grade of the control animal was 0 grade, and there was no animal showing more than 1 grade in the skin reaction of the test animal. As a result of both tests, no abnormal skin symptoms were observed, and when applied to the human body to treat patients, the test materials used in the tests will investigate the stability of whether any diseases that cause skin abnormal symptoms will occur.

Performance Testing of Medical US Equipment Using US Phantom(ATS-539) (Focusing on Daegu Region) (초음파팬텀(ATS-539)을 이용한 의료용 초음파장비의 성능검사(대구지역을 중심으로))

  • Kim, Do-Hyung;Kwon, Deok-Moon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.295-305
    • /
    • 2014
  • This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment.

Efficient Application of Westgard Multi-Rules and Quality Control Implementation Improvement (Westgard Multi-Rules의 효율적 적용과 조치사항의 개선)

  • Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.

  • PDF

Korean Word Sense Disambiguation using Dictionary and Corpus (사전과 말뭉치를 이용한 한국어 단어 중의성 해소)

  • Jeong, Hanjo;Park, Byeonghwa
    • Journal of Intelligence and Information Systems
    • /
    • v.21 no.1
    • /
    • pp.1-13
    • /
    • 2015
  • As opinion mining in big data applications has been highlighted, a lot of research on unstructured data has made. Lots of social media on the Internet generate unstructured or semi-structured data every second and they are often made by natural or human languages we use in daily life. Many words in human languages have multiple meanings or senses. In this result, it is very difficult for computers to extract useful information from these datasets. Traditional web search engines are usually based on keyword search, resulting in incorrect search results which are far from users' intentions. Even though a lot of progress in enhancing the performance of search engines has made over the last years in order to provide users with appropriate results, there is still so much to improve it. Word sense disambiguation can play a very important role in dealing with natural language processing and is considered as one of the most difficult problems in this area. Major approaches to word sense disambiguation can be classified as knowledge-base, supervised corpus-based, and unsupervised corpus-based approaches. This paper presents a method which automatically generates a corpus for word sense disambiguation by taking advantage of examples in existing dictionaries and avoids expensive sense tagging processes. It experiments the effectiveness of the method based on Naïve Bayes Model, which is one of supervised learning algorithms, by using Korean standard unabridged dictionary and Sejong Corpus. Korean standard unabridged dictionary has approximately 57,000 sentences. Sejong Corpus has about 790,000 sentences tagged with part-of-speech and senses all together. For the experiment of this study, Korean standard unabridged dictionary and Sejong Corpus were experimented as a combination and separate entities using cross validation. Only nouns, target subjects in word sense disambiguation, were selected. 93,522 word senses among 265,655 nouns and 56,914 sentences from related proverbs and examples were additionally combined in the corpus. Sejong Corpus was easily merged with Korean standard unabridged dictionary because Sejong Corpus was tagged based on sense indices defined by Korean standard unabridged dictionary. Sense vectors were formed after the merged corpus was created. Terms used in creating sense vectors were added in the named entity dictionary of Korean morphological analyzer. By using the extended named entity dictionary, term vectors were extracted from the input sentences and then term vectors for the sentences were created. Given the extracted term vector and the sense vector model made during the pre-processing stage, the sense-tagged terms were determined by the vector space model based word sense disambiguation. In addition, this study shows the effectiveness of merged corpus from examples in Korean standard unabridged dictionary and Sejong Corpus. The experiment shows the better results in precision and recall are found with the merged corpus. This study suggests it can practically enhance the performance of internet search engines and help us to understand more accurate meaning of a sentence in natural language processing pertinent to search engines, opinion mining, and text mining. Naïve Bayes classifier used in this study represents a supervised learning algorithm and uses Bayes theorem. Naïve Bayes classifier has an assumption that all senses are independent. Even though the assumption of Naïve Bayes classifier is not realistic and ignores the correlation between attributes, Naïve Bayes classifier is widely used because of its simplicity and in practice it is known to be very effective in many applications such as text classification and medical diagnosis. However, further research need to be carried out to consider all possible combinations and/or partial combinations of all senses in a sentence. Also, the effectiveness of word sense disambiguation may be improved if rhetorical structures or morphological dependencies between words are analyzed through syntactic analysis.