• 제목/요약/키워드: Medical Implants

검색결과 450건 처리시간 0.026초

미니 임플란트를 이용한 하악의 임플란트 지지 피개의치: 증례보고 (Mandibular Mini-Implants Supported Overdentures: A Case Report)

  • 박진홍;이정열;신상완
    • 대한구강악안면임플란트학회지
    • /
    • 제19권3호
    • /
    • pp.146-152
    • /
    • 2015
  • Mini-dental implants for overdenture applications are increasingly popular due to their ease in placement with simplified, less traumatic surgical protocols in limited-width alveolar ridges. However, the clinical decisions including implant number, position, and loading protocol must be based on a thorough evaluation and evidence-based diagnosis. Herein, we reported a case treated with the current method of mandibular mini-implant supported overdenture.

상악동 거상술을 동반한 임플란트 식립 후 생존율에 대한 후향적 연구 (The retrospective study of survival rate of implants with maxillary sinus floor elevation)

  • 유정아;이상민;유미경;정의원;김창성;최성호;박필규;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제39권3호
    • /
    • pp.293-301
    • /
    • 2009
  • Purpose: The purpose of this study is to show the total survival rate of implants with maxillary sinus floor elevation and the effects that reach the survival rate by classifying types of graft materials, implant surface, operation method, bone height. Methods: In a total of 131 patients, 251 implants with sinus floor elevation were installed simultaneously or after regular healing. Various bone grafts (autograft, xonograft, allograft, alloplast) and implant surface (MTX-HA implant, chemical etching implant, Titanium oxide surface implant, resorbable blasting media implant, resorbable blast texturing implant, HA-coated implant) were used. All implants were investigated clinically and radiographically, being with 1 to 5 years follow-up period after installation. Results: The survival rate of 251 implants with maxillary sinus floor elevation was 94%. The types of implant, surface, graft material, bone height have no statistically signi-ficant differencies. Conclusions: It can be suggested that maxillary sinus floor elevation may have predictable result with various bone graft materials and implant surface.

Full mouth implant rehabilitation of a patient with ectodermal dysplasia after orthognathic surgery, sinus and ridge augmentation: a clinical report

  • Bayat, Mohammad;Khobyari, Mohammad Mohsen;Dalband, Mohsen;Momen-Heravi, Fatemeh
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.96-100
    • /
    • 2011
  • An 18-year-old male presented severe hypodontia due to hypohidrotic ectodermal dysplasia was treated with Le Fort I maxillary osteotomy with simultaneous sinus floor augmentation using the mixture of cortical autogenous bone graft harvested from iliac crest and organic Bio-Oss to position the maxilla in a right occlusal plane with respect to the mandible, and to construct adequate bone volume at posterior maxilla allowing proper implant placement. Due to the poor bone quality at other sites, ridge augmentation with onlay graft was done to construct adequate bone volume allowing proper implant placement, using tissue harvested from the iliac bone. Seven implants were placed in the maxilla and 7 implants were inserted in the mandible and screw-retained metal ceramic FPDs were fabricated. The two year follow up data showed that dental implants should be considered as a good treatment modality for patients with ectodermal dysplasia.

Maxillofacial reconstruction with Medpor porous polyethylene implant: a case series study

  • Khorasani, Mansour;Janbaz, Pejman;Rayati, Farshid
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제44권3호
    • /
    • pp.128-135
    • /
    • 2018
  • Objectives: The role of alloplastic materials in maxillofacial reconstruction is still controversial. Determining the utility of porous, high-density, polyethylene implants as a highly stable and flexible, porous alloplast, with properties such as rapid vascularization and tissue ingrowth, is crucial in cases of maxillofacial deformities and aesthetic surgery. Materials and Methods: Thirty high-density porous polyethylene implants were implanted in 16 patients that had been referred to a private office over a three-year period. These implants were used for correcting congenital deformities, posttraumatic defects and improving the aesthetic in nasal, paranasal, malar, chin, mandibular angle, body and orbital areas. Results: The outcomes of the cases in this study showed good aesthetic and functional results. The majority of patients had no signs of discomfort, rejection or exposure. Two implants suffered complications: a complicated malar implant was managed by antibiotic therapy, and an infected mandibular angle implant was removed despite antibiotic therapy. Conclusion: Based on the results, the Medpor implant seems to be an excellent biomaterial for correcting various facial deformities. Advantages include its versatility and relatively ideal pore size that allows for excellent soft tissue ingrowth and coverage. It is strong, flexible and easy to shape.

A TWO-YEAR STUDY OF IMPLANT RETAINED OVERDENTURES IN THE TREATMENT OF TOTALLY EDENTULOUS JAWS

  • Kwon, Ho-Beom;Kim, Eun-Ha;Lee, Seok-Hyoung
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.760-768
    • /
    • 2007
  • Statement of problem. Conventional denture treatment for totally edentulous patients is associated with a variety of functional and psychosocial problems. The placement of implants in the anterior region of the maxilla and mandible and the fabrication of an implant-retained overdenture might solve these problems. Purpose. This study compared the marginal bone loss around the implant and evaluated the implant survival rate and complications in patients treated with overdentures retained by implants for 2 years. Material and methods. Patients who had received implant-retained overdentures using a Dolder bar at Samsung Medical Center from January 1999 to June 2005 and had participated in the annual recall programs for two years were selected for this study. A total of 18 patients and 56 $Br{\aa}ne-mark\;system^{(R)}$ implants were used, and their data were reviewed. Evaluations of the survival rate, bone quality, marginal bone loss, and complications were performed. The data on the Dolder bar length and clip length were measured. The change in marginal bone loss and the correlation between the marginal bone loss and bar length, clip length, or bone quality were investigated. Results. Implants placed in this study showed a 100% survival rate. The average annual bone loss was 1.12mm in the first year and 0.27mm in the second year in the maxilla, and 0.58mm in the first year and 0.22mm in the second year in the mandible. The marginal bone loss in the maxilla showed no significant association with those in the mandible. (P>.05). There was no significant difference in marginal bone loss around implants between the first and second year. (P>.05) There was no statistically significant relationship (P>.05) between the marginal bone loss and bone quality, clip length, or Dolder bar length. The Dolder bar length showed a high correlation with the clip length. (P<.05) Various complications were noted. Conclusion. These results confirmed the favorable outcome for patients treated with implant-retained overdentures.

The occurrence of dental implant malpositioning and related factors: A cross-sectional cone-beam computed tomography survey

  • Safi, Yaser;Amid, Reza;Zadbin, Fariba;Ahsaie, Mitra Ghazizadeh;Mortazavi, Hamed
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.251-260
    • /
    • 2021
  • Purpose: Dental implants are widely used for the rehabilitation of edentulous sites. This study investigated the occurrence of dental implant malpositioning as shown on post-implantation cone-beam computed tomography (CBCT) and to identify related factors. Materials and Methods: Samples with at least 1 malpositioned dental implant were collected from a central radiology clinic in Tehran, Iran from January 2017 to January 2019. Variables such as demographic characteristics, length and diameter of implants, type of implant, sites of implant insertion, different types of implant malpositioning problems (cortical plate perforation, interference with anatomical structures), angulation of the implant, and the severity of malpositioning were assessed. In addition, the incidence of implant fracture and over-drilling was evaluated. Data were statistically analyzed using the chi-square test, 1-sample t-test, and Spearman correlation coefficients. Results: In total, 252 patients referred for implant postoperative CBCT evaluations were assessed. The cases of implant malpositioning included perforation of the buccal cortical plate (19.4%), perforation of the lingual cortical plate (14.3%), implant proximity to an adjacent implant (19.0%), implant proximity to an adjacent tooth (3.2%), interference with anatomical structures(maxillary sinus: 18.3%, mandibular canal: 11.1%, nasal cavity: 6.3%, mental foramen: 5.6%, and incisive canal: 0.4%). Implant fracture and over-drilling were found in 1.6% and 0.8% of cases, respectively. Severity was categorized as mild (9.5%), moderate (35.7%), severe (37.7%), and extreme (17.1%), and 52.4% of implants had inappropriate angulation. Conclusion: CBCT imaging is recommended for detecting dental implant malpositioning. The most common and severe type of malpositioning was buccal cortex perforation.

치과용 임플란트에 대한 ISO 14971 기반의 리스크관리 (Application of Risk Management for Dental Implants Based on ISO 14971)

  • 윤지훈;김영진;전계록;정창모
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.92-97
    • /
    • 2012
  • Risk management is the process that helps to identify hazards, analyze them, and then to create an action plan to avoid and mitigate these hazards. The main objective of risk management in product development and manufacturing is to provide safe and efficient products without spending too many resources. Medical device manufacturers also face enormous risks - regulatory, legal, and financial - based on their products and processes, and the concepts of risk management are particularly important because any single failure may result in serious damages to body or loss of life. In this regard, a set of guidelines for the application of risk management to medical devices has been issued by ISO and specified in the document ISO 14971 Medical devices - Application of risk management to medical devices. The main objective of this study is to investigate the application of risk management to dental implant development and manufacturing processes based on ISO 14971. A general risk management process is first introduced, and the application of ISO 14971 to dental implants is further investigated.

임프란트 표면처리 방법에 따른 골유착의 조직계측학적 분석 및 제거회전력 비교 연구 (HISTOMORPHOMETRIC AND REMOVAL TORQUE VALUES COMPARISION OF ROUGH SURFACE TITANIUM IMPLANTS)

  • 이상철;송우식
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제23권5호
    • /
    • pp.396-405
    • /
    • 2001
  • Osseointegrated implants are used for the fixation of dental prosthesis with good long-term clinical results. In an attempt to improve the quantity and quality of the bone-implant interface, numerous implant modification have been used. Implants surface modifications have been used such as titanium-plasma sprayed, hydroxyapatite-coating, sandblasted, sandblasted and acid-etched, acid-etched. Rough surface implants have greater implant surface area and enhance the bone-implant interface and improve stabilization. The purpose of present study was to evaluate light microscopic and scanning microscopic examinations and removal torque value of newly developed calcium phosphate blast and acid-etched implant in the femur of rabbits. Titanium plasma sprayed(TPS) implant served as controls. After 12 weeks of healing of the femurs of 12 rabitts, the implant-containing segments of femur were removed on bloc and bone block including sections. Histologic examination and histomorphometric and removal torque values comparision were made for two implants. Obtained results are follows: 1. Newly developed calcium phosphate blasted and acid-etched implants were in close contact with bone under light microscopic examinations. 2. New implants showed mean bone-to implant contact 59.8%, whereas TPS implants showed mean bone-to implant contact 54.5% (statistically no difference p<0.05). 3. New implants showed mean bone density 56.7%, whereas TPS implants showed mean bone density 49.2% (statistically difference p<0.05). 4. New implants demonstrated mean removal torque values 40.5Ncm, whereas the mean removal torque values of TPS implants ranged 39.3Ncm. No statistical differences(p<0.05) were observed between two groups of implants nor was there any difference between the two implants at the clinical level.

  • PDF

실리콘겔 인공유방의 기계적 및 물리화학적 특성에 대한 연구 (Study for Mechanical and Physicochemcial Properties of Silicone Gel Filled Mammary Implants)

  • 백홍;장동혁;송정민;이승영;서무엽;박길종;맹은호
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권2호
    • /
    • pp.89-97
    • /
    • 2012
  • The purpose of this study is to develop the guideline of the physicochemical and mechanical properties evaluation for silicone gel filled breast implants. First of all, the use and development status for silicone gel filled breast implants were investigated, and then, standard and criteria about performance evaluation established by the international organizations such as ASTM, FDA guidance and ISO were examined. To evaluate the mechanical properties, data research and testing for breaking strength, elongation, tensile set, joint intensity, silicone gel cohesion, weight loss from heating, static rupture resistance, impact resistance test, fatigue test, and gel bleed were performed. On the other hand, to evaluate the physicochemical properties, volatile matter, extent of cross linking, heavy metals, and extractable were analyzed. In this study, results for general function, mechanical properties and physicochemical properties were examined and reviewed for the accordance with international standard, and objective and standardized guideline was provided.

구치부 부분 무치악 결손에서 유용한 세 가지 임프란트 수복법들의 응력분산에 관한 3차원 유한요소법적 비교연구 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE STRESS DISTRIBUTION IN THE THREE TREATMENT OPTIONS OF IMPLANTS RESTORATIONS FOR THE POSTERIOR PARTIAL EDENTULISM)

  • 김일규;이성호;류승현;최진호;한예숙;손충렬;변효인
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권3호
    • /
    • pp.175-180
    • /
    • 2004
  • In this study, three treatment options to replace two posterior missing teeth were investigated using three dimensional finite element analysis: two wide(${\phi}5.0mm$) implants(the experimental model I), two standard(${\phi}3.75mm$) implants(the experimental model II), and three standard(${\phi}3.75mm$) implants(the experimental model III). Two kinds of load case were applied ; 1) perpendicular on occlusal surface(axial load), parallel on occlusal surface(lateral load). 2) perpendicular on occlusal surface(3mm lateral to central point). The results obtained from this study were as follows; value of Von-mises stress (equivalent stress) was smallest in the two wide implant among the three experimental models. It was reported that the diameter is the efficient factor than osseointegrated surface area.