1 |
Nelaton C, Ombredanne L, Berger P, Hartmann H. La rhinoplastie. Paris: G. Steinheil; 1904.
|
2 |
Joseph J. Treatise on rhinoplasty. Berl Klin Wochenschr 1907;44:470.
|
3 |
Israel J. Two new methods of rhinoplasty. Plast Reconstr Surg 1970;46:80-3.
DOI
|
4 |
Von Mangold H. Correction of saddle nose by cartilage transplant. Gesell Chir 1900;29:460-3.
|
5 |
Brown JB, Fryer MP, Randall P, Lu M. Silicones in plastic surgery; laboratory and clinical investigations, a preliminary report. Plast Reconstr Surg (1946) 1953;12:374-6.
DOI
|
6 |
Niazi TN, Coppens J, Liu JK, Couldwell WT. Medpor implant in cranioorbitomaxillary reconstruction: institutional experience and a review of the literature. J Oral Maxillofacial Surg 2008;7:444-8.
|
7 |
Deshpande S, Munoli A. Long-term results of high-density porous polyethylene implants in facial skeletal augmentation: an Indian perspective. Indian J Plast Surg 2010;43:34-9.
DOI
|
8 |
Ram H, Singh RK, Mohammad S, Gupta AK. Efficacy of Iliac crest vs. Medpor in orbital floor reconstruction. J Maxillofac Oral Surg 2010;9:134-41.
DOI
|
9 |
Cenzi R, Guarda-Nardini L. [Use of porous plyethylene (Medpor) in maxillofacial surgery]. Minerva Stomatol 1995;44:559-82. Italian.
|
10 |
Rubin PA, Bilyk JR, Shore JW. Orbital reconstruction using porous polyethylene sheets. Ophthalmology 1994;101:1697-708.
DOI
|
11 |
Klawitter JJ, Bagwell JG, Weinstein AM, Sauer BW. An evaluation of bone growth into porous high density polyethylene. J Biomed Mater Res 1976;10:311-23.
DOI
|
12 |
Spector M, Flemming WR, Sauer BW. Early tissue infiltrate in porous polyethylene implants into bone: a scanning electron microscope study. J Biomed Mater Res 1975;9:537-42.
DOI
|
13 |
Kim HS, Park SS, Kim MH, Kim MS, Kim SK, Lee KC. Problems associated with alloplastic materials in rhinoplasty. Yonsei Med J 2014;55:1617-23.
DOI
|
14 |
Ridwan-Pramana A, Wolff J, Raziei A, Ashton-James CE, Forouzanfar T. Porous polyethylene implants in facial reconstruction: outcome and complications. J Craniomaxillofac Surg 2015;43:1330-4.
DOI
|
15 |
Niechajev I. Facial reconstruction using porous high-density polyethylene (Medpor): long-term results. Aesthetic Plast Surg 2012;36:917-27.
DOI
|
16 |
Mohammadi S, Mohseni M, Eslami M, Arabzadeh H, Eslami M. Use of porous high-density polyethylene grafts in open rhinoplasty: no infectious complication seen in spreader and dorsal grafts. Head Face Med 2014;10:52.
DOI
|
17 |
Baj A, Spotti S, Marelli S, Beltramini GA, Gianni AB. Use of porous polyethylene for correcting defects of temporal region following transposition of temporalis myofascial flap. Acta Otorhinolaryngol Ital 2009;29:265-9.
|
18 |
Rapidis AD, Day TA. The use of temporal polyethylene implant after temporalis myofascial flap transposition: clinical and radiographic results from its use in 21 patients. J Oral Maxillofac Surg 2006;64:12-22.
|
19 |
Xu JJ, Teng L, Jin XL, Ji Y, Lu JJ, Zhang B. Porous polyethylene implants in orbital blow-out fractures and enophthalmos reconstruction. J Craniofac Surg 2009;20:918-20.
DOI
|
20 |
Tsouknidas A, Maropoulos S, Savvakis S, Michailidis N. FEM assisted evaluation of PMMA and Ti6Al4V as materials for cranioplasty resulting mechanical behaviour and the neurocranial protection. Biomed Mater Eng 2011;21:139-47.
|
21 |
Lin IC, Liao SL, Lin LL. Porous polyethylene implants in orbital floor reconstruction. J Formos Med Assoc 2007;106:51-7.
DOI
|
22 |
Sun L, Xiao J, Lan Y, Xiong Y, Zhang L, Zhou H, et al. [Reconstruction of the orbital fracture with enophthalmos using customized titanium mesh combined with Medpor]. West China J Stomatol 2015;33:272-5. Chinese.
|
23 |
He D, Li Z, Shi W, Sun Y, Zhu H, Lin M, et al. Orbitozygomatic fractures with enophthalmos: analysis of 64 cases treated late. J Oral Maxillofac Surg 2012;70:562-76.
DOI
|
24 |
Yilmaz M, Vayvada H, Aydin E, Menderes A, Atabey A. Repair of fractures of the orbital floor with porous polyethylene implants. Br J Oral Maxillofac Surg 2007;45:640-4.
DOI
|
25 |
Cenzi R, Farina A, Zuccarino L, Carinci F. Clinical outcome of 285 Medpor grafts used for craniofacial reconstruction. J Craniofac Surg 2005;16:526-30.
DOI
|
26 |
Yaremchuk MJ. Facial skeletal reconstruction using porous polyethylene implants. Plast Reconstr Surg 2003;111:1818-27.
DOI
|
27 |
Gosau M, Schiel S, Draenert GF, Ihrler S, Mast G, Ehrenfeld M. [Craniofacial augmentation with porous polyethylene implants (Medpor): first clinical results]. Mund Kiefer Gesichtschir 2006;10:178-84. German.
DOI
|
28 |
Menderes A, Baytekin C, Topcu A, Yilmaz M, Barutcu A. Craniofacial reconstruction with high-density porous polyethylene implants. J Craniofac Surg 2004;15:719-24.
DOI
|
29 |
Romo T 3rd, Litner JA, Sclafani AP. Management of the severe bulbous nasal tip using porous polyethylene alloimplants. Facial Plast Surg 2003;19:341-8.
DOI
|
30 |
Emsen IM. E-M shaped septal encircling with Medpor reconstruction on crooked noses: personal technique and postoperative results. J Craniofac Surg 2008;19:216-26.
DOI
|
31 |
Spector M, Harmon SL, Kreutner A. Characteristics of tissue growth into proplast and porous polyethylene implants in bone. J Biomed Mater Res 1979;13:677-92.
DOI
|
32 |
Rees TD. Physical considerations for the aesthetic surgery of the neck and face. In: Rees TD, ed. Aesthetic plastic surgery. Philadelphia: W.B. Saunders; 1980:587.
|
33 |
Maas CS, Merwin GE, Wilson J, Frey MD, Maves MD. Comparison of biomaterials for facial bone augmentation. Arch Otolaryngol Head Neck Surg 1990;116:551-6.
DOI
|
34 |
Wolfe SA, Berkowitz S. Plastic surgery of the facial skeleton. Boston: Little, Brown; 1989:687.
|
35 |
Gui L, Huang L, Zhang Z. Genioplasty and chin augmentation with Medpore implants: a report of 650 cases. Aesthetic Plast Surg 2008;32:220-6.
DOI
|
36 |
Breadon GE, Kern EB, Neel HB 3rd. Autografts of uncrushed and crushed bone and cartilage. Experimental observations and clinical implications. Arch Otolaryngol 1979;105:75-80.
DOI
|
37 |
Gosain AK; Plastic Surgery Eductional Foundation DATA Committee. Biomaterials for reconstruction of the cranial vault. Plast Reconstr Surg 2005;116:663-6.
DOI
|
38 |
Wellisz T, Lawrence M, Jazayeri MA, Golshani S, Zhou ZY. The effects of alloplastic implant onlays on bone in the rabbit mandible. Plast Reconstr Surg 1995;96:957-63.
DOI
|
39 |
Rubin JP, Yaremchuk MJ. Complications and toxicities of implantable biomaterials used in facial reconstructive and aesthetic surgery: a comprehensive review of the literature. Plast Reconstr Surg 1997;100:1336-53.
DOI
|
40 |
Yaremchuk MJ. Infraorbital rim augmentation. Plast Reconstr Surg 2001;107:1585-92; discussion 1593-5.
DOI
|
41 |
Shanbhag A, Friedman HI, Augustine J, von Recum AF. Evaluation of porous polyethylene for external ear reconstruction. Ann Plast Surg 1990;24:32-9.
DOI
|
42 |
Frodel JL, Lee S. The use of high-density polyethylene implants in facial deformities. Arch Otolaryngol Head Neck Surg 1998;124:1219-23.
DOI
|
43 |
Wellisz T, Dougherty W. The role of alloplastic skeletal modification in the reconstruction of facial burns. Ann Plast Surg 1993;30:531-6.
DOI
|
44 |
Romano JJ, Iliff NT, Manson PN. Use of Medpor porous polyethylene implants in 140 patients with facial fractures. J Craniofac Surg 1993;4:142-7.
DOI
|