Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF

Analysis of $^{99m}Tc-ECD$ Brain SPECT Images for ADHD in Children Using Statistical Parametric Mapping (SPM) (주의력 결핍 과잉행동장애(ADHD) 어린이 $^{99m}Tc-ECD$ Brain SPECT Image의 SPM을 이용한 분석)

  • 박성옥;신동호;권수일;이명훈;조철우;윤석남;오은영
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.141-148
    • /
    • 2003
  • The purpose of this study is to evaluate the distribution of clusters and blood flow rate in ADHD SPECT brain blood flow images of children using statistical parametric mapping (SPM99). We studied 64 ADHD children (4-15 y, $8.03{\pm}2.57$ y. male/female:52/12) and compared them with a control group of 12 children (6-l7 y, $9.42{\pm}3.37$ y, male/female:8/4). We injected blood flow tracer $^{99m}Tc$-ethylcysteinate dimer (ECD) as a rCBF agent and took blood flow images after 30 min. by SPECT camera. In the case of hyperperfusion of rCBF in the ADHD group, we found 3 clusters clearly separated at the cingulate gyrus, Rt.cerebral occipital lobe and Lt.cerebellar post. lobe, on probability level 0.05 (P<0.05). Thirty-six ADHD patients with average hyperfusion rates between 18.72-19.30% in each cluster had more increase in blood flow than the average perfusion rate at the Rt. cerebral occipital lobe. These levels were influenced by P-value. In the case of hypoperfusion in the ADHD children, 4 decreased clusters on Lt. and Rt. cerebral frontal lobe, Lt. cerebral claustrum and Rt. cerebral, sup. temporal gyrus at P<0.01 can be seen. The average hypoperfusion rates for the ADHD children were 18.41-18.69% in each cluster, which showed more hypopefusion than the average perfusion rate at the Lt. Cerebrum inf. Frontal gyrus. The perfusion rates and the number of patients were not affected by P-value. The result of this study shows significant hyperpefusion clusters at the probability level of P:0.05 and hypoperfusion clusters at P:0.01. The number of ADHD patients in each clusters and the perfusion rate were not affected by P-value.

  • PDF

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

A CLINICAL STUDY OF THE JUDGMENT OF SASANG CONSTITUTION ACCORDING TO QUESTIONNAIRE (설문지(設問紙)를 통한 사상체질(四象體質)의 임상적(臨床的) 분류방안(分類方案) 연구(硏究))

  • Kim, Young-woo;Kim, Jong-weon
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.1
    • /
    • pp.215-233
    • /
    • 1998
  • The object of this study is 27 patients who had been treated in the Oriental Medical Hospital at Dong Eui Medical Center during 6 months from January 1998 to June 1998. We proceeded the judgment of Sasang Constitution by Questionaire of Sasang Constitution Classification II(QSCC II). The following conclusion were made in comparison with Questionaire of Sasang Constitution Classification II(QSCC II) and Questionaire of Pusan Sasang seminar. 1. The subject of "the facial type is small and sharp" is significant differences in Sasang Constitution classification. The frequency of Soeumin group is more than Taeumin group and Soyangin group. 2. The subject of "the walking form is fast and shake the body" is significant differences in Sasang Constitution classification. The frequency of Taeumin group and Soeumin group is less than Soyangin group. 3. The subject of "the skin type is white and thin" is significant differences in Sasang Constitution classification. The frequency of Soeumin group is more than Soyangin group, and the frequency of Taeumin group is low marks. 4. The subject of "the skin type is tender and dry" is significant differences in Sasang Constitution classification. The frequency of Taeumin group and Soyangin group is less than Soeumin group. 5. The subject of "the image of face is smart" is significant differences in Sasang Constitution classification. The frequency of Soeumin group is more than Taeumin group and the frequency of Soyangin group is low marks. 6. The subject of "the sweating type is not sweatier" is significant differences in Sasang Constitution classification. The frequency of Taeumin group and Soeumin group is less than Soyangin group. 7. The subject of "the desire of eating is changeable accoding to emotion" is significant differences in Sasang Constitution classification. The frequency of Soeumin group is more than Taeumin group and Soyangin group. 8. The subject of "the health is changeable accoding to the type of stool" is significant differences in Sasang Constitution classification. The frequency of Soeumin group is more than Soyangin group and the frequency of Taeumin group is low marks. 9. The subject of "the type of voiding is changeable accoding to the drinking when they have a fever" is significant differences in Sasang Constitution classification. The frequency of Taeumin group and Soyangin group is less than Soeumin group. 10. The subject of "the skin type is soft" is significant differences in Sasang Constitution classification. The frequency of Soeumin group is more than Taeumin group and Soyangin group. 11. The subject of "the chief complaint is the forgetfulness" is significant differences in Sasang Constitution classification. The frequency of Soeumin group is less than Taeumin group and Soyangin group.

  • PDF

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

Analysis of Respiratory Motion Artifacts in PET Imaging Using Respiratory Gated PET Combined with 4D-CT (4D-CT와 결합한 호흡게이트 PET을 이용한 PET영상의 호흡 인공산물 분석)

  • Cho, Byung-Chul;Park, Sung-Ho;Park, Hee-Chul;Bae, Hoon-Sik;Hwang, Hee-Sung;Shin, Hee-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Purpose: Reduction of respiratory motion artifacts in PET images was studied using respiratory-gated PET (RGPET) with moving phantom. Especially a method of generating simulated helical CT images from 4D-CT datasets was developed and applied to a respiratory specific RGPET images for more accurate attenuation correction. Materials and Methods: Using a motion phantom with periodicity of 6 seconds and linear motion amplitude of 26 mm, PET/CT (Discovery ST: GEMS) scans with and without respiratory gating were obtained for one syringe and two vials with each volume of 3, 10, and 30 ml respectively. RPM (Real-Time Position Management, Varian) was used for tracking motion during PET/CT scanning. Ten datasets of RGPET and 4D-CT corresponding to every 10% phase intervals were acquired. from the positions, sizes, and uptake values of each subject on the resultant phase specific PET and CT datasets, the correlations between motion artifacts in PET and CT images and the size of motion relative to the size of subject were analyzed. Results: The center positions of three vials in RGPET and 4D-CT agree well with the actual position within the estimated error. However, volumes of subjects in non-gated PET images increase proportional to relative motion size and were overestimated as much as 250% when the motion amplitude was increased two times larger than the size of the subject. On the contrary, the corresponding maximal uptake value was reduced to about 50%. Conclusion: RGPET is demonstrated to remove respiratory motion artifacts in PET imaging, and moreover, more precise image fusion and more accurate attenuation correction is possible by combining with 4D-CT.

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.

Correlation Analysis Between 3D Kidneys Measurements and Abdominal Obesity Level in Computed Tomography (전산화단층영상에서 콩팥 3차원 영상 계측치와 복부 비만도 간의 상관관계 분석)

  • Ji-Yeong Kim;Youl-Hun Seoung
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.315-325
    • /
    • 2023
  • The purpose of this study was to predict abdominal obesity with 3-Dimensional computed tomography (3D CT) measurements of kidneys by analyzing the correlation between kidney sizes and abdominal obesity level. The subjects were 178 healthy adults without underlying diseases who had a comprehensive health examination at the Health Medical Center of Jesus Hospital in Jeonju. Abdominal obesity was measured by CT cross-sectional image at the level of the umbilicus and divided into visceral fat area, subcutaneous fat area, visceral fat/total fat ratio. The average comparison of kidney sizes classified according to abdominal obesity were performed through one-way analysis of variance (ANOVA) and Scheffe test. Pearson correlation analysis was performed to correlate all measurement values. The results of kidney size ANOVA analysis according to abdominal obesity were as follows. The means of kidney measurements according to visceral fat classification were significantly different in all kidney measurements (p<0.05). And in case of subcutaneous fat classification, the means of kidney measurements by 3D CT of the severe obesity group were significantly different in the right kidney width (p<0.05). In case of visceral fat area/total fat area ratio, the means of kidney measurements by 3D CT of the severe obesity group were significantly different in both kidneys width (p<0.05). Pearson correlation between kidneys measurements and CT abdominal obesity showed that visceral fat area had the highest correlation with the left kidney width measured by 3D CT (r=0.467) and subcutaneous fat area had correlation with the right kidney width measured by 3D CT (r=0.249). The visceral fat area/total fat area ratio had correlation with the left kidney width measured by 3D CT (r=0.291).

The Measurement of Sensitivity and Comparative Analysis of Simplified Quantitation Methods to Measure Dopamine Transporters Using [I-123]IPT Pharmacokinetic Computer Simulations ([I-123]IPT 약역학 컴퓨터시뮬레이션을 이용한 민감도 측정 및 간편화된 운반체 정량분석 방법들의 비교분석 연구)

  • Son, Hye-Kyung;Nha, Sang-Kyun;Lee, Hee-Kyung;Kim, Hee-Joung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.19-29
    • /
    • 1997
  • Recently, [I-123]IPT SPECT has been used for early diagnosis of Parkinson's patients(PP) by imaging dopamine transporters. The dynamic time activity curves in basal ganglia(BG) and occipital cortex(OCC) without blood samples were obtained for 2 hours. These data were then used to measure dopamine transporters by operationally defined ratio methods of (BG-OCC)/OCC at 2 hrs, binding potential $R_v=k_3/k_4$ using graphic method or $R_A$= (ABBG-ABOCC)/ABOCC for 2 hrs, where ABBG represents accumulated binding activity in basal ganglia(${\int}^{120min}_0$ BG(t)dt) and ABOCC represents accumulated binding activity in occipital cortex(${\int}^{120min}_0$ OCC(t)dt). The purpose of this study was to examine the IPT pharmacokinetics and investigate the usefulness of simplified methods of (BG-OCC)/OCC, $R_A$, and $R_v$ which are often assumed that these values reflect the true values of $k_3/k_4$. The rate constants $K_1,\;k_2\;k_3$ and $k_4$ to be used for simulations were derived using [I-123]IPT SPECT and aterialized blood data with a standard three compartmental model. The sensitivities and time activity curves in BG and OCC were computed by changing $K_l$ and $k_3$(only BG) for every 5min over 2 hours. The values (BG-OCC)/OCC, $R_A$, and $R_v$ were then computed from the time activity curves and the linear regression analysis was used to measure the accuracies of these methods. The late constants $K_l,\;k_2\;k_3\;k_4$ at BG and OCC were $1.26{\pm}5.41%,\;0.044{\pm}19.58%,\;0.031{\pm}24.36%,\;0.008{\pm}22.78%$ and $1.36{\pm}4.76%,\;0.170{\pm}6.89%,\;0.007{\pm}23.89%,\;0.007{\pm}45.09%$, respectively. The Sensitivities for ((${\Delta}S/S$)/(${\Delta}k_3/k_3$)) and ((${\Delta}S/S$)/(${\Delta}K_l/K_l$)) at 30min and 120min were measured as (0.19, 0.50) and (0.61, 0,23), respectively. The correlation coefficients and slopes of ((BG-OCC)/OCC, $R_A$, and $R_v$) with $k_3/k_4$ were (0.98, 1.00, 0.99) and (1.76, 0.47, 1.25), respectively. These simulation results indicate that a late [I-123]IPT SPECT image may represent the distribution of the dopamine transporters. Good correlations were shown between (3G-OCC)/OCC, $R_A$ or $R_v$ and true $k_3/k_4$, although the slopes between them were not unity. Pharmacokinetic computer simulations may be a very useful technique in studying dopamine transporter systems.

  • PDF