• Title/Summary/Keyword: Medical IT convergence

Search Result 1,122, Processing Time 0.032 seconds

Electrochemical Characteristics of Pencil Graphite Electrode Through Surface Modification and its Application of Non-enzymatic Glucose Sensor (표면 개질된 샤프심 전극의 전기화학적 특성 고찰 및 비효소적 글루코스 센서 활용)

  • Min-Jung Song
    • Korean Chemical Engineering Research
    • /
    • v.62 no.2
    • /
    • pp.147-152
    • /
    • 2024
  • Most medical sensors are disposable products. In order to reduce inspection and diagnosis costs, it is more important to develop the inexpensive electrode materials. We fabricated the CuO NPs/PANI/E-PGE as an electrode material for disposable electrochemical sensors and applied it to a non-enzymatic glucose sensor. For surface activation of PGE, pretreatment was performed using chemical and electrochemical methods, respectively. Electrochemical properties according to the pretreatment method were analyzed through chronoamperometry (CA), cyclic voltammetry (CV) and electrochemical impedance (EIS). From these analytical results, the electrochemically pretreated PGE (E-PGE) was finally adopted. The non-enzymatic glucose sensor based on CuO NPs/PANI/E-PGE shows sensitivity of 239.18 mA/mM×cm2 (in a linear range of 0.282~2.112 mM) and 36.99 mA/mM×cm2 (3.75423~50 mM), detection limit of 17.6 μM and good selectivity. Based on the results of this study, it was confirmed that the modified PGE is a high-performance electrode material. Therefore, these electrodes can be applied to a variety of disposable sensors.

Antiinflammatory Activity of Solvent-partitioned Fractions from Atriplex gmelinii C. A. Mey. in LPS-stimulated RAW264.7 Macrophages (염생식물 가는갯는쟁이 용매 추출물의 항염증활성)

  • Jeong, Heejeong;Kim, Hojun;Ju, Eunsin;Lee, Seul-Gi;Kong, Chang-Suk;Seo, Youngwan
    • Journal of Life Science
    • /
    • v.27 no.2
    • /
    • pp.187-193
    • /
    • 2017
  • As a part of ongoing research to elucidate and characterize antiinflammatory nutraceuticals, the crude extracts from Atriplex gmelinii C. A. Mey. and their solvent-partitioned fractions were tested for their antiinflammatory potential in lipopolysaccharide (LPS)-stimulated RAW 264.7 mouse macrophages. The crude extracts of A. gmelinii C. A. Mey. were fractioned according to polarity with n-hexane, 85% aqueous methanol (85% aq. MeOH), n-butanol, and $H_2O$. Their antiinflammatory activities were investigated in LPS-induced inflammation in mouse macrophages by measuring nitric oxide (NO) generation and mRNA expression of inflammation mediators, namely, inducible nitric oxide synthase (iNOS), cyclooxygenase-2 (COX-2), interleukin-$1{\beta}$ ($IL-1{\beta}$), and IL-6. As a result, we confirmed that the crude extracts of A. gmelinii C. A. Mey. inhibited LPS-stimulated NO production and mRNA expression of iNOS and COX-2 as important inflammatory factors. The inhibition of NO production through the downregulation of important inflammatory factors such as iNOS, COX-2, $IL-1{\beta}$, and IL-6 was found by treatment with all solvent-partitioned fractions. Among all tested fractions, 85% aq. MeOH showed the strongest antiinflammatory response. Based on the current results, A. gmelinii C. A. Mey. was suggested to possess natural antiinflammatory components, indicating that it could be used as a valuable source of antiinflammatory substances.

Evaluation of Attenuation Rate Error on Skin Dosimeter using Monte Carlo Simulation in Photon and Electron Beam Therapy (광자선 및 전자선 치료에서 피부선량계의 측정과 시뮬레이션을 이용한 감약률 오차 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Heo, Seung-Uk;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.841-848
    • /
    • 2020
  • In the field of radiation therapy using photon beams and electron beams, since each patient has a different sensitivity to radiation, skin side effects may occur even at the same dose. Therefore, if there is a risk of excessive dose to the skin, a dosimeter is attached to verify whether the correct dose is being investigated. However, since the skin dosimeter checks the attachment site visually by measuring a point dose, it is difficult to confirm an accurate dose distribution. As a result, the measurement and simulation errors of the material HgI2 in the 6 MV photon beam were 3.73% and 5.24%, respectively, at the minimum thickness of 25 ㎛, and the material PbI2 was 4.73% and 5.65%, respectively. On the other hand, as a result of the 6 MeV electron beam, the measurement and simulation errors of the material HgI2 were 1.35% and 1.12%, respectively, at a minimum thickness of 25 ㎛, and the material PbI2 showed relatively low attenuation error, 1.67% and 1.20%, respectively. Therefore, it was evaluated that the thickness of the photon beam within 25 ㎛ and the electron beam within 100 ㎛ is suitable to have a reduction rate error within 5%. This study presents a new research direction for a flexible dosimeter attached to the human body that is required in clinical practice and the construction conditions of a future skin dosimeter.

The effect of Type 2 diabetes management using a smartphone-based blood glucose management training program (모바일 자가혈당관리 교육프로그램을 이용한 2형 당뇨병 관리 효과 분석)

  • Lee, Jung-Hwa;Jung, Jin-Hee;Sim, Kang-Hee;Choi, Hee-Sun;Lee, Jeong-Rim;Kang, Yang-Gyo;Song, Bok-Rye
    • Journal of Industrial Convergence
    • /
    • v.20 no.9
    • /
    • pp.59-70
    • /
    • 2022
  • Background: Diabetes education is an important factor in blood glucose control. Reinforced education is necessary for effective diabetes education. However, it is difficult to provide reinforced diabetes education within Korea's medical environment. Therefore, we want to analyze the effect of continuous diabetes education using mobile health care that can effectively provide repeated education without having to face the patient. Methods: This study is a multicenter, randomized, controlled, pre-post design study conducted to analyze the effect of a continuous diabetes education method. A total of 109 people were registered at five hospitals in south Korea, and they were randomly assigned to the app group (34 people) who received real-time coaching and repetitive training, the logbook group (37 people) who received face-to-face training after writing a blood glucose logbook, and the general group (38 people) who received a one-time diabetes education. The study was conducted for a total of 24 weeks. Twenty-one patients withdrew their consent and failed to perform an HbA1c. A final 88 patients were analyzed. The difference in HbA1c, Self-management behavior, and Quality of life before and after education was analyzed. Results: The study involved 51 (58%) male subjects, mean age was 55.8 years and mean duration of diabetes was 7.6 years. After 24 weeks of intervention, there was no significant difference in self-care behavior and quality of life between the three groups, but the HbA1c of the app group significantly decreased after education compared to the logbook group and the general group (F=4.62, p=.013). Conclusion: It can be seen through the app group that receiving real-time education is more effective in improving blood glucose management and continuous diabetes education is important.

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Body Composition Factor Comparisons of the Intracellular Fluid(ICW), Extracellular Fluid(ECW) and Cell Membrane at Acupuncture Points and Non-Acupuncture Points by Inducing Multiple Ionic Changes (생체이온 변화 유발 후 경혈과 비경혈에서의 생체 구조 성분 분석 및 비교를 통한 경혈 특이성 고찰)

  • Kim, Soo-Byeong;Chung, Kyung-Yul;Jeon, Mi-Seon;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.31 no.2
    • /
    • pp.66-78
    • /
    • 2014
  • Objectives : The specificity of acupuncture point has been a highly controversial subject. Existing researches said that ion-distribution differences are observed on the acupuncture point. This study was conducted under the assumption that multiple ionic changes induced by muscle fatigue would be different between the acupuncture point with non-acupuncture point. Methods : To induce the identical fatigue, twenty subjects performed the knee extension/flexion exercise using the Biodex System 3. ST32 and ST33 as well as adjacent non-acupuncture points were selected. We measured blood lactate and analyzed the median frequency(MF) and peak torque. To obtain the information on the extracellular fluid(ECW), intracellular fluid(ICW) and cell membrane indirectly, we used the multi-frequency bioelectrical impedance analysis(MF-BIA) method. Results : MF, peak torque and blood lactate level of all measurement sites were gradually returned to normal. Re resistance of ST32 had a stronger response, but a non-acupuncture point adjacent to ST33 had a larger response up to 20 minutes post exercise. Ri resistances were similar for both acupoints and non-acupoints. The $C_m$ capacitance of ST32 had a stronger response after inducing fatigue, but ST33 had a smaller response than a non-acupuncture point adjacent to it. Conclusions : In comparison with before and after inducing fatigue, the specificity of acupuncture points was not clearly observed. Hence, we concluded that the body composition factors extraction method had the limitation as a method of finding the specificity of acupuncture points by inducing fatigue.

Estimated Exposure Dose and Usage of Radiological Examination of the National Health Screening (국가건강검진의 방사선검사 이용량 및 피폭선량 추정)

  • Gil, Jong Won;Park, Jong Hyock;Park, Min Hui;Park, Chan Young;Kim, So Young;Shin, Dong Wook;Kim, Won Dong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.142-149
    • /
    • 2014
  • Korea conducts a national health screening program to improve and check-up on public health and in recent years, the screening usage has been increased. Given the increased screening usage for radiographic exams, this study predicts the frequency of using radiographic exams and the exposure dose. This study estimates the usage of radiographic exams by isolating radiographic exams from the 2011 analysis of the national health insurance corporation, and estimates the public exposure dose by applying each procedure's dose table from UNSCEAR 2008. As a result of the analysis, in the 2011 National Health Screening, the average exposure dose per person is assumed to be 0.57 mSv, and depending on the type of screening program from the radiographic exam, an examinee could be exposed to between 0.2 mSv and 11.081 mSv. The frequency of using radiographic exposure was found to be 16,005,914 and the exposure dose was 6,311.76 person-Sv. The most frequent exam is the Chest X-ray, which was performed 1,070,567 (69.17%), and the UGI has the highest exposure dose at 5,217.94 person-Sv (82.67%). The outcome is categorized based on gender and age, excluding those under 39 years old. In all age groups, the screening usage and exposure dose are higher in females than in males. In particular, females between 50 and 54 years old have the highest screening usage (1,674,787, 10.5%) and exposure dose (701.59 person-Sv, 11.1%). As UGI accounts for 82.76% of procedures, except when done for medical purposes, if the government supports a voluntary UGI exam (which includes the UGI exam in the National Screening Program) or abolishes it completely, as seen overseas, the cost-effectiveness and validity of the UGI exam, as well as the exposure dose from the National Screening Program will all decrease significantly.

A Study on the Applicability of Social Security Platform to Smart City (사회보장플랫폼과 스마트시티에의 적용가능성에 관한 연구)

  • Jang, Bong-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.321-335
    • /
    • 2020
  • Given that with the development of the 4th industry, interest and desire for smart cities are gradually increasing and related technologies are developed as a way to strengthen urban competitiveness by utilizing big data, information and communication technology, IoT, M2M, and AI, the purpose of this study is to find out how to achieve this goal on the premise of the idea of smart well fair city. In other words, the purpose is to devise a smart well-fair city in the care area, such as health care, medical care, and welfare, and see if it is feasible. With this recognition, the paper aimed to review the concept and scope of smart city, the discussions that have been made so far and the issues or limitations on its connection to social security and social welfare, and based on it, come up with the concept of welfare city. As a method of realizing the smart welfare city, the paper reviewed characteristics and features of a social security platform as well as the applicability of smart city, especially care services. Furthermore, the paper developed discussions on the standardization of the city in terms of political and institutional improvements, utilization of personal information and public data as well as ways of institutional improvement centering on social security information system. This paper highlights the importance of implementing the digitally based community care and smart welfare city that our society is seeking to achieve. With regard to the social security platform based on behavioral design and the 7 principles(6W1H method), the present paper has the limitation of dealing only with smart cities in the fields of healthcare, medicine, and welfare. Therefore, further studies are needed to investigate the effects of smart cities in other fields and to consider the application and utilization of technologies in various aspects and the corresponding impact on our society. It is expected that this paper will suggest the future course and vision not only for smart cities but also for the social security and welfare system and thereby make some contribution to improving the quality of people's lives through the requisite adjustments made in each relevant field.

An Efficient Addressing Scheme Using (x, y) Coordinates in Environments of Smart Grid (스마트 그리드 환경에서 (x, y) 좌표값을 이용한 효율적인 주소 할당 방법)

  • Cho, Yang-Hyun;Lim, Song-Bin;Kim, Gyung-Mok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.1
    • /
    • pp.61-69
    • /
    • 2012
  • Smart Grid is the next-generation intelligent power grid that maximizes energy efficiency with the convergence of IT technologies and the existing power grid. Smart Grid is created solution for standardization and interoperability. Smart Grid industry enables consumers to check power rates in real time for active power consumption. It also enables suppliers to measure their expected power generation load, which stabilizes the operation of the power system. Smart industy was ecolved actively cause Wireless communication is being considered for AMI system and wireless communication using ZigBee sensor has been applied in various industly. In this paper, we proposed efficient addressing scheme for improving the performance of the routing algorithm using ZigBee in Smart Grid environment. A distributed address allocation scheme used an existing algorithm has wasted address space. Therefore proposing x, y coordinate axes from divide address space of 16 bit to solve this problem. Each node was reduced not only bitwise but also multi hop using the coordinate axes while routing than Cskip algorithm. I compared the performance between the standard and the proposed mechanism through the numerical analysis. Simulation verify performance about decrease averaging multi hop count that compare proposing algorithm and another. The numerical analysis results show that proposed algorithm reduce multi hop than ZigBee distributed address assignment and another.

Characteristics and Side effects Relevance of Physically Restrained Elderly Patients with Dementia in the Nursing Hospitals (요양병원에서 신체억제대를 적용한 일부 치매노인 환자의 특성과 부작용 관련성)

  • Kim, Su-Youn;Chae, Kyung-Suk
    • Journal of Digital Convergence
    • /
    • v.16 no.4
    • /
    • pp.221-229
    • /
    • 2018
  • The purpose of this study was to identify the characteristics and side effects relevance of physically restrained elderly patients with dementia in the nursing hospitals. The data were collected from nursing care providers working at the 5 nursing hospitals with survey and analyzed 190 data using SPSS 21.0 program. The finding showed that age of '75 to 84' years occupied 58.3%, '17-24' hours of the total restrained time of the day 22.6%, night time 57.4% and no fall down history 54.2%. Age showed relevance with local edema and problem of joint construction(p<.05), specifically '85 and over' years having 25% occurrence in the problem of joint construction. Walking ability showed relevance with pressure ulcer, but in the patients who could walk it showed more frequency than in the patients who could not walk. The total restrained time of the day showed relevance with skin redness, local edema, problem of joint construction(p<.05). Based on this finding, it would be necessary to apply differential care policies according to the characteristics of patients when we care the restrained patients with dementia.