• 제목/요약/키워드: Medical Exposure

검색결과 1,987건 처리시간 0.029초

Analysis of Trends in Dose through Evaluation of Spatial Dose Rate and Surface Contamination in Radiation-Controlled Area and Personal Exposed Dose of Radiation Worker at the Korea Institute of Radiological and Medical Sciences (KIRAMS)

  • Lee, Bu Hyung;Kim, Sung Ho;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Park, Seungwoo;Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.146-155
    • /
    • 2016
  • As the probability of exposure to radiation increases due to an increase in the use of radioisotopes and radiation generators, the importance of a radiation safety management field is being highlighted. We intend to help radiation workers with exposure management by identifying the degree of radiation exposure and contamination to determine an efficient method of radiation safety management. The personal exposure doses of the radiation workers at the Korea Institute of Radiological & Medical Sciences measured every quarter during a five-year period from Jan. 1, 2011 till Dec. 31, 2015 were analyzed using a TLD (thermoluminescence dosimeter). The spatial dose rates of radiation-controlled areas were measured using a portable radioscope, and the level of surface contamination was measured at weekly intervals using a piece of smear paper and a low background alpha/beta counter. Though the averages of the depth doses and the surface doses in 2012 increased from those in 2011 by about 14%, the averages were shown to have decreased every year after that. The exposure dose of 27 mSv in 2012 increased from that in 2011 in radiopharmaceutical laboratories and, in the case of the spatial dose rate, the rate of decrease in 2012 was shown to be similar to the annual trend of the whole institute. In the case of the surface contamination level, as the remaining radiation-controlled area with the exception of the I-131 treatment ward showed a low value less than $1.0kBq/m^2$, the annual trend of the I-131 treatment ward was shown to be similar to that of the entire institute. In conclusion, continuous attention should be paid to dose monitoring of the radiation-controlled areas where unsealed sources are handled and the workers therein.

소음유발 청력손실과 소음폭로에 대한 연구 (The analysis of the relation between noise induced hearing loss and noise exposure)

  • 장호경
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.217-225
    • /
    • 1998
  • 본 연구에서는 A청감보정 소음레벨과 폭로기간에 대한 소음유발 청력손실과 소음폭로 사이의 관계를 해석하였다. 연령과 소음폭로등 다양한 변수에 대하여 청력손실과 청감민감도 변화를 조사하였다. 연구결과 전체 청력손실은 음압의 시간적분에 의한 소음폭로 레벨에 비례하였다. 만약 소음폭로가 노인성 난청보다 크면 연령과 소음에 의해 발생하는 청력손실은 주된 원인이 소음에 의한 것임을 확인하였다. 과도한 소음은 일시적 청력손실의 원인이며, 폭로가 길어지거나 강력하면 영구적 청력손실의 원인이 될 수 있다. 소음유발 청력손실을 겪는 사람의 청력도는 4kHz 영역에서 청감민감도의 급격한 손실을 보여주며, 이 영역은 여러 형태의 산업소음으로 인해 가장 손상받기 쉬운 전형적인 주파수영역임을 확인하였다.

  • PDF

Influence of the Vibration Exposure on Shoulder and Back Extensor Muscles Activity During Forward-head and Over-head Task

  • Cheon-jun Park;Duk-hyun An;Jae-seop Oh;Won-gyu Yoo
    • 한국전문물리치료학회지
    • /
    • 제30권1호
    • /
    • pp.23-31
    • /
    • 2023
  • Background: Several factors contribute to shoulder pain, including abnormal neck posture, repeated use of the upper limbs, work involving raising the upper limbs above the head, and the effects of vibration. However, previous study has reported that constant vibration exposure could impact improvement of the stability on joints related with muscle recruitment and activation. For this difference reason, we need to verify for the complex study of relationship with repetitive upper limb movements, poor head posture, and constant vibration exposure. Objects: Our study was made to investigate the influence of vibration exposure on the shoulder muscle activity during forward-head and over-head tasks with isometric shoulder flexion. Methods: In a total of 22 healthy subjects, surface electromyography (EMG) data were collected from shoulder muscles (upper/lower trapezius, serratus anterior, and lumbar erector spinae) on tasks (neutral-head task [NHT], forward-head task [FHT], and over-head task [OHT]) with and without vibration exposure. Results: In all tasks, the EMG data of the upper trapezius and serratus anterior significantly increased with vibration exposure (p < 0.05). Furthermore, the EMG data of the lumbar erector spinae significantly increased with vibration exposure in the NHT and FHT (p < 0.05). Conclusion: We suggest that continuous vibration exposure during the use of hand-held tools in the tasks could be associated with harmful effects in the workplace. Lastly, we clinically need to examine the guidelines regarding the optimal posture and vibration exposure.

흉부촬영시 피폭선량과 화질에 관한 조사연구 (The Study on the Image Quality and Patient Exposure Dose of Chest Radiography in Korea)

  • 이선숙;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권2호
    • /
    • pp.49-59
    • /
    • 1995
  • Recently, general radiography became to variety because of the continuous development of Inverter type generator and ortho chromatic system. Therefore, we must re-evaluate about patient exposure dose and image quality. I studied about chest radiography which has frequency among general radiography being used during FEB. to AUG., 1994 over 151 medical facilities from medical facilities that are located in Seoul area. The result obtained were as follows ; 1) The rectification method of the generator were employing mainly single phase full wave in 82.8 %, three phase full wave in 11.26 % and Inverter type in 4.64 % and condenser type is 1.32 %. 2) Exposure kV was used below 80 kV in most medical facilities and 21.8 % of the medical facilities was using high tube voltage higher than 120 kV. 3) The exposure time was used below the 0.05 sec in 28.4 %, in 29.8 % of the medical facilities used above 0.1 sec. 4) The usage frequency of the added filter is 15.3 %, and among them compound filter was used only 4 %. 5) Rare earth screen was used in 37.7 %. 6) The average skin entrance dose was 0.25 mSv, the range of dose is $0.05{\sim}0.79\;mSv$ in each medical facilities. 7) The average density of the lung field is 1.76, 0.49 in lung side, 0.30 in mediastinum and 0.37 in heart shadow. Therefore it is required to improve all of these for increasing image quality and reducing patient exposure dose as soon as possible.

  • PDF

Assessment of Chemical Risks in Moroccan Medical Biology Laboratories in Accordance with the CLP Regulation

  • Mourry, Ghita E.;Alami, Rachid;Elyadini, Adil;Hajjaji, Souad El;kabba, Saad El;Zouhdi, Mimoun
    • Safety and Health at Work
    • /
    • 제11권2호
    • /
    • pp.193-198
    • /
    • 2020
  • Background: Medical laboratory workers are frequently exposed to a wide range of chemicals. This exposure can have adverse effects on their health. Furthermore, a knowledge lack of the chemical risk increases the likelihood of exposure. The chemical risk assessment reduces the risk of exposure to hazardous chemicals and therefore, guarantees health and safety of the workers. Method: The chemical risk assessment was conducted using a modified INRS method, according to the new CLP Regulation, of 11 unit laboratories in a Moroccan medical laboratory. Observation of each workstation and analysis of safety data sheets are key tools in this study. Results: A total of 144 substances and reagents that could affect the health of the analytical technicians were identified. Among these products, 17% are concerned by the low priority risk score, with 55% concerned by the average priority risk score and 28% concerned by the high priority risk score. This study also enabled to better identify the chemical agents that have restrictive occupational exposure limit value and controls were conducted to this effect. On the basis of the results obtained, several corrective and preventive measures have been proposed and implemented. Conclusion: Risk assessment is essential to ensure the health and safety of workers and to meet regulatory requirements. It enables to identify all the risky manipulations and to adopt appropriate preventive measures. However, it is not a one-time activity but it must be continuous in order to master the changes and thus ensure the best safety of all.

Radiation Dose Distribution of a Surgeon and Medical Staff during Orthopedic Balloon Kyphoplasty in Japan

  • Ono, Koji;Kumasawa, Takafumi;Shimatani, Keiichi;Kanou, Masatoshi;Yamaguchi, Ichiro;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.86-92
    • /
    • 2022
  • Background: The present study investigated the radiation dose distribution of balloon kyphoplasty (BKP) among surgeons and medical staff, and this is the first research to observe such exposure in Japan. Materials and Methods: The study subjects were an orthopedic surgeon (n = 1) and surgical staff (n = 9) who intervened in BKP surgery performed at the National Hospital Organization Disaster Medical Center (Tokyo, Japan) between March 2019 and October 2019. Only disposable protective gloves (0.022 mmPb equivalent thickness or less) and trunk protectors were used, and no protective glasses or thyroid drapes were used. Results and Discussion: The surgery time per vertebral body was 36.2 minutes, and the fluoroscopic time was 6.8 minutes. The average exposure dose per vertebral body was 1.46 mSv for the finger (70 ㎛ dose equivalent), 0.24 mSv for the lens of the eye (3 mm dose equivalent), 0.11 mSv for the neck (10 mm dose equivalent), and 0.03 mSv for the chest (10 mm dose equivalent) under the protective suit.The estimated cumulative radiation exposure dose of 23 cases of BKP was calculated to be 50.37 mSv for the fingers, 8.27 mSv for the lens, 3.91 mSv for the neck, and 1.15 mSv for the chest. Conclusion: It is important to know the exposure dose of orthopedic surgeons, implement measures for exposure reduction, and verify the safety of daily use of radiation during surgery and examination.

Dermal Exposure Associated with Occupational End Use of Pesticides and the Role of Protective Measures

  • MacFarlane, Ewan;Carey, Renee;Keegel, Tessa;El-Zaemay, Sonia;Fritschi, Lin
    • Safety and Health at Work
    • /
    • 제4권3호
    • /
    • pp.136-141
    • /
    • 2013
  • Background: Occupational end users of pesticides may experience bodily absorption of the pesticide products they use, risking possible health effects. The purpose of this paper is to provide a guide for researchers, practitioners, and policy makers working in the field of agricultural health or other areas where occupational end use of pesticides and exposure issues are of interest. Methods: This paper characterizes the health effects of pesticide exposure, jobs associated with pesticide use, pesticide-related tasks, absorption of pesticides through the skin, and the use of personal protective equipment (PPE) for reducing exposure. Conclusions: Although international and national efforts to reduce pesticide exposure through regulatory means should continue, it is difficult in the agricultural sector to implement engineering or system controls. It is clear that use of PPE does reduce dermal pesticide exposure but compliance among the majority of occupationally exposed pesticide end users appears to be poor. More research is needed on higher-order controls to reduce pesticide exposure and to understand the reasons for poor compliance with PPE and identify effective training methods.

ICP-MS와 AAS를 이용한 체내 혈청 Cu, Zn 분석에 관한 연구 (Analysis of Copper, Zinc in Serum Using ICP-MS & AAS)

  • 이예진;김동엽;이고은;조영숙
    • 대한임상검사과학회지
    • /
    • 제41권1호
    • /
    • pp.31-36
    • /
    • 2009
  • The exposure of human beings to toxic trace metals (Cu, Zn) continues to be an important public health issue and concern. This study was conducted to assess the exposure to trace metals (Cu, Zn) in the general Korean population by inductively coupled plasma mass spectrometry (ICP-MS) and Atomic absorption spectrometry (AAS). Serum samples were obtained from 40 healthy volunteers. Specimens were collected in special container and we applied sample processing to minimize contamination. We used ICP-MS and AAS to analyze simultaneously the concentration of metals including copper, zinc. Distribution of trace metal levels in the general healthy population showed lower values. The results in this study can provide background data for clinical studies associated with trace metal exposure in the korean population.

  • PDF

Blue light Exposure Control System Using Sensor Modules

  • Lim, Myung-Jae;Jung, Dong-Kun;Kim, Kyu-Dong;Kwon, Young-Man
    • International Journal of Advanced Culture Technology
    • /
    • 제9권4호
    • /
    • pp.315-319
    • /
    • 2021
  • Recent impact of 4th industrial revolution is increasing usage of IoT technology along with smartphones and tablet PC. However blue light emitted from electronic devices such as smartphones and tablet PC causes detrimental change to human bodies. As the controversy over the harmfulness of blue light became known through the media and various communities, related markets were formed, and various blocking films, software, and vision protection monitors were released. In this paper focuses on utilizing IoT technology to protect human organizations from blue light. It presents anti-blue light system which prevents excessive exposure to blue light through Arduino module such as ultrasound, piezo buzzer and blue light measurement module.