• Title/Summary/Keyword: Medical Device Management

Search Result 288, Processing Time 0.024 seconds

Channel Selection Method of Wireless Sensor Network Nodes for avoiding Interference in 2.4Ghz ISM(Industrial, Scientific, Medical) Band (2.4Ghz ISM(Industrial Scientific Medical) 밴드에서 간섭을 회피하기 위한 무선 센서 노드의 채널 선택 방법)

  • Kim, Su Min;Kuem, Dong Hyun;Kim, Kyung Hoon;Oh, Il;Choi, Seung Won
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.4
    • /
    • pp.109-116
    • /
    • 2014
  • In recent, ISM (Industrial Scientific Medical) band that is 2.4GHz band authorized free of charge is being widely used for smart phone, notebook computer, printer and portable multimedia devices. Accordingly, studies have been continuously conducted on the possibility of coexistence among nodes using ISM band. In particular, the interference of IEEE 802.11b based Wi-Fi device using overlapping channel during communication among IEEE 802.15.4 based wireless sensor nodes suitable for low-power, low-speed communication using ISM band causes serious network performance deterioration of wireless sensor networks. This paper examined a method of identifying channel status to avoid interference among wireless communication devices using IEEE 802.11b (Wi-Fi) and other ISM bands during communication among IEEE 802.15.4 based wireless sensor network nodes in ISM band. To identify channels occupied by Wi-Fi traffic, various studies are being conducted that use the RSSI (Received Signal Strength Indicator) value of interference signal obtained through ED (Energy Detection) feature that is one of IEEE 802.15.4 transmitter characteristics. This paper examines an algorithm that identifies the possibility of using more accurate channel by mixing utilization of interference signal and RSSI mean value of interference signal by wireless sensor network nodes. In addition, it verifies such algorithm by using OPNET Network verification simulator.

Development of a Mobile Application for Disease Prediction Using Speech Data of Korean Patients with Dysarthria (한국인 구음장애 환자의 발화 데이터 기반 질병 예측을 위한 모바일 애플리케이션 개발)

  • Changjin Ha;Taesik Go
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • Communication with others plays an important role in human social interaction and information exchange in modern society. However, some individuals have difficulty in communicating due to dysarthria. Therefore, it is necessary to develop effective diagnostic techniques for early treatment of the dysarthria. In the present study, we propose a mobile device-based methodology that enables to automatically classify dysarthria type. The light-weight CNN model was trained by using the open audio dataset of Korean patients with dysarthria. The trained CNN model can successfully classify dysarthria into related subtype disease with 78.8%~96.6% accuracy. In addition, the user-friendly mobile application was also developed based on the trained CNN model. Users can easily record their voices according to the selected inspection type (e.g. word, sentence, paragraph, and semi-free speech) and evaluate the recorded voice data through their mobile device and the developed mobile application. This proposed technique would be helpful for personal management of dysarthria and decision making in clinic.

Core Technology for Ultra Low Power Using Cold Restart in Wearable Devices (Cold Restart를 이용한 웨어러블 디바이스의 초저전력 핵심 기술)

  • Kim, Seon-Tae;Park, Hyoung Jun;Park, Ho-Jun;Woo, Duk-Kyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.44-49
    • /
    • 2017
  • There are many battery-based wearable devices for healthcare and medical applications, but there is a user's inconvenience to charge battery frequently due to insufficient power management. In this paper, we propose a tickless-based operating system and power management algorithm that can effectively utilize the power management provided by HW, and propose a cold restart method that consumes the minimum power at the board level. The operating system of the proposed technique has reduced the power consumption from 2 times to 33 times in the four scenarios modeling the wearable device application compared to the existing operating system.

A Design of Air Compressor Remote Control System Using USN Technology (USN 기술을 이용한 공기압축기 원격관리 시스템 설계)

  • Hwang, Moon-Young
    • Korean Journal of Artificial Intelligence
    • /
    • v.6 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Compressed Air is an important energy source used in most factories nowadays. The automation trend using air compressor has been gradually increasing with the interest of the 4th industry in recent years. With the air compressor system, it is possible to construct the device at low cost and easily achieve automation and energy saving. In addition, With trend of FA, miniaturation and light weight manufacturing trend expand their use in the electronics, medical, and food sectors. Research method is to design the technology for the remote control of the following information as USN base. Development of flexible sensing module from real time observation module for fusion of IT technology in compressed air systems, design and manufacture of flexible sensing module, and realiability assessment. Design of real-time integrated management system for observation data of compressed air system - Ability to process observation data measured in real time into pre-processing and analysis data. This study expects unconventionally decreasing effect of energy cost that takes up 60~70% of air compressor layout and operation and maintenance management cost through USN(Ubiquitous Sensor Network) technology by using optimum operational condition from real time observation module. In addition, by preventing maintenance cost from malfunction of air compressor beforehand, maintenance cost is anticipated to cut back.

Status of Occupational Health Management in Some Small-Scale-Industries (일부 소규모 사업장의 산업보건 실태)

  • Hwang, Moon Jeong
    • Korean Journal of Occupational Health Nursing
    • /
    • v.8 no.2
    • /
    • pp.169-175
    • /
    • 1999
  • The study was purposed to know the status of health management in small-scale-industries which have less than 50 employees. A total of 330 small-scale-industries were surveyed by nurses and industrial-hygienists who were affiliated with industrial health care agency from January, 1993 to December, 1994. The contents of survey include status of work environment, occupational accident and its disease availability, protective evice, health education and settlements. The results were as follows: 1. The number of industrial accidents(death, injury arid occup. disease) in 1994 was 83 which was reduced from that of the 1993 which was 126. 2. As a result of the measurement of work environment the excessive ratio of permitted criteria was reduced to 20.6% in 1994 from 264% in 1993, and the improvement ratio of work environment was increased to 39.5% in 1994 from 29.7% in 1993. 3. The contents of health education at work place were as follows: general disease(25.4%), work environment(20.2%), protective device(16.7%), disease prevension(14.2%), occupational disease(85%), and health promotion(8.3%). 4. In terms of industrial safty and prevention of occupational disease, only 10.6% was satisfactory or excellent, and the 89.4% was poor, inadequate or required reexamination.

  • PDF

Problems of the Radiation Safety Management System and Legal Improvement Plans in the Department of Radiological Science: Focusing on the survey of the head of the Department of Radiological Science (방사선(학)과 방사선 안전관리제도의 문제점과 법적 개선방안: 전국 방사선(학)과장 설문조사를 중심으로)

  • Hyun-Jung, Lee;Chang-Gyu, Kim;Man-Seok, Han;Cheol-Ha, Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.815-824
    • /
    • 2022
  • The current radiation safety management system is also applied to radiation practices at universities. The application of the law raised concerns about poor radiation practice education and hindering the development of radiology. Accordingly, the Korean Radiology Professors Association needed to grasp the reality of the management system for radiation practice education at each university and the current radiation safety management system in the department of Radiological science. So, a survey was conducted on heads of radiological science departments across the country. Through the survey, it was found that the current application of the Nuclear Safety Act to radiation safety management in the department of Radiological science is excessively restrictive and not very effective. In addition, radiology practice education for the purpose of training health and medical professionals should be controlled by the Ministry of Health and Welfare and the Korea Centers for Disease Control, but there is a problem of being supervised by the Nuclear Safety and Security Commission. Therefore, in this study, as a legal improvement plan to solve this problem, first, a plan according to a partial amendment to the Higher Education Act, second, a plan to be supervised by the Ministry of Health and Welfare through the amendment of article 37 of the Medical Service Act, third, article 20-2 of the Enforcement Decree of the Medical Service Technologists Act was newly inserted to propose three measures to be supervised by the Ministry of Health and Welfare.

Design of a Tracking & Recall Management System for Implantable Devices (이식형 의료기기의 추적 및 회수 관리를 위한 통합전산관리시스템 설계)

  • Park, Soon-Mahn;Yoo, Sun-Kook
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.5
    • /
    • pp.74-80
    • /
    • 2011
  • Medical implant devices are one of the targets of the US's Food & Drug Administration (FDA) for tracking in case of a serious adverse event since they are directly connected to the lives of patients. The US law stipulates that the public health agency shall order implantable device makers to track their product down to the patient level if a serious adverse event has occurred or defects have been discovered; in reality, however, the agency can pass on the responsibility for tracking or recalling faulty devices to the manufacturers or use mass media. This article proposes an efficient tracking and recall management system and examines four main virtual scenarios based on such. This research seeks to suggest a system that enables FDA to perform accurate and prompt tracking and recall management for patients' enhanced safety.

Self-management techniques and subsequent changes in pain and function in patients with chronic low back pain (만성 요통 환자의 자가 관리 요법에 따른 통증 및 기능의 변화)

  • Choi, Jun Hyun;Kim, Eun-Shil;Yoon, Yong-Soon;Kim, Ka-Eun;Lee, Mi-Hyun;Jang, Hong-Young
    • Journal of Digital Convergence
    • /
    • v.18 no.10
    • /
    • pp.547-555
    • /
    • 2020
  • To investigate the effects of self-management programs for chronic low back pain (LBP), 63 subjects were assigned to three groups; self-exercise group (SEG), hot pack and low-frequency electrical stimulation group (HEG), and thermo-massage group (TMG). Parameters were the pain numeric rating scale (PNRS), Oswestry Disability Index (ODI), Roland Morris Disability Questionnaire (RMDQ) and Relapse frequency (RF). PNRS, ODI and RMDQ of SEG and TMG sustained effectiveness, however, PNRS, which improved after treatment in HEG, worsened in 6 month. Between the groups, all parameters were better in SEG and TMG compare to HEG. Exercise and thermo-massage can be considered as useful self-management performed at home to prevent the relapse of chronic LBP.

Authentication Protocol based on Credential for Implantable Medical Device (체내 삽입장치를 위한 위임장 기반의 인증 프로토콜)

  • Jeong, Yoon-Su
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.259-264
    • /
    • 2014
  • Body insertion due to the recent development of sensor technology, the device is attached patients to receive medical services from anywhere, anytime environment is changing. Body insertion devices for the hospital, the patient's vital information attached personnel (doctors, nurses, pharmacists, etc.) to pass, however, when a problem occurs, a patient's information to a third party that can be exploited easily exposed. In this paper, we proposed signature authentication protocols mandate based on the patient's power of attorney from the center of the u-Healthcare services, hospital officials FormHelper third party disguised as a patient, the hospital patient information easily obtained from the officials to prevent. The proposed protocol, the patient's sensitive information to a third party, do not expose the patient's sensitive information to the random number generated by the u-Healthcare service centers and patients hash signature key to encrypt sensitive information of patients. From third parties to maintain synchronization between the patients and the hospital personnel in order to prevent patient information from being exploited illegally by the patient's vital information leakage can be prevented.

Develop 3D Prostate Cancer Visualization Tool in Smart Care System (스마트 케어 시스템에서의 3차원 전립선 암 가시화 도구 개발)

  • Ahn, Byung Uk;Shin, Seung Won;Choi, Moon Hyung;Jung, Seung Eun;Kim, Kwang Gi
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.163-169
    • /
    • 2016
  • In Korea, prostate cancer accounted for generating growth rate second the following thyroid cancer, because of western dietary habits. Survival rate of prostate cancer after clinical behavior is changed depend on follow-up management. A telemedicine have been applied to replacement of medical specialist in rural area, and a quick reaction to emergency situation. Our study developed prostate 3-dimensional (3D) visualization program and designed prostate aftercare system architecture, called smart care, using a device that can access the Internet. Region of interest (ROI) in prostate was manually segmented by physicians and visualized to 3D objects and sent to PACS Server as DICOM images. So, medical personnel could confirm patients' data along with 3D images not only PACS system, but also portable device like a smart phone. As a result, we conducted the aftercare service to 98 patients and visualize 3D prostate images. 3D images had advantage to instinctively apprehend where lesion is and make patients to understand state of their disease easily. In the future, should conduct an aftercare service to more patients, and will obtain numerical index through follow-up study to an accurate analysis.