• Title/Summary/Keyword: Median value

Search Result 778, Processing Time 0.026 seconds

A STUDY ON MAXILLARY MEDIAN DIASTEMA OF 'Y' PRIMARY SCHOOL CHILDREN ('Y' 국민학교 아동의 상악중절치 치간이개증에 관한 연구)

  • Hahn, Se-Hyun
    • The Journal of the Korean dental association
    • /
    • v.19 no.12 s.151
    • /
    • pp.1039-1044
    • /
    • 1981
  • The author surveyed on maxillary median diastema of 1440 (male: 740, female:700) 'Y' primary school children aged from 6 to 12 and obtained the following results. 1. The prevalence of maxillary median diastema was 16.08% in male, 14.00% in female and 15.07% in both sexes. 2. The prevalence of maxillary median distema showed the highest rate in 8 years old children (male: 29.55%, female: 34.83%) and it showed decreasing tendency according to increasing age. 3. The prevalence of mesiodens was 0.79% and boys had higher rate than girls. 4. Mean value of 'Divergent degree' was 20.6mm in male, 20.5mm in female and mean value of 'Frenum distance' was 4.08mm in male, 41.1mm in female.

  • PDF

A Study on the Maxillary Median Diastema (II) (상악중절치 치간이개증에 관한 연구 (II))

  • Han, Se-Hyeon
    • The Journal of the Korean dental association
    • /
    • v.21 no.10 s.173
    • /
    • pp.829-833
    • /
    • 1983
  • The author surveyed on the maxillary median diastema of 1,686(male; 850, female; 836) 'H' and 'K' primary school children aged from 6 to 13. The results were as follows : 1. The prevalence of the maxillay median diastema was 12.6% in male, 7.9% in female and 10.3% in both sexes. 2. The prevalence of the maxillary median diastema showed the highest rate in 9 years old boys and 8 years old girls, and it showed decreasing tendency according to increasing age. 3. The prevalence of mesiodens was 0.6% and boys had higher rate than girls. 4. Mean value of 'Frenum Distance' was 5.8mm in male, 5.7mm in female and mean value of 'Divergent Degree' was 2.0mm in male, 1.6mm in female.

  • PDF

The effective noise reduction method in infrared image using bilateral filter based on median value

  • Park, Chan-Geun;Choi, Byung-In
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.27-33
    • /
    • 2016
  • In this paper, we propose the bilateral filter based on median value that can reduce random noise and impulse noise with minimal loss of contour information. In general, EO / IR camera to generate a random or impulse noise due to a number of reasons. This noise reduces the performance of detecting and tracking by signal processing. To reduce noise, our proposed bilateral filter sorts the values of the target pixel and the peripheral pixels, and extracts a median filter coefficients of the Gaussian type. Then to extract the Gaussian filter coefficient involved with the distance between the center pixel and the surrounding pixels. As using those filter coefficients, our proposed method can remove the various noise effectively while minimizing the loss of the contour information. To validate our proposed method, we present experimental results for several IR images.

Position Value for Relative Comparison of Healthcare Status of Korea in 2019: Comparison with Countries of the Organization for Economic Cooperation and Development (2019년 한국 보건의료의 상대적 위치와 추이: 경제협력개발기구 국가와 비교)

  • Park, Minah;Youn, Hin-Moi;Park, Eun-Cheol
    • Health Policy and Management
    • /
    • v.32 no.1
    • /
    • pp.113-121
    • /
    • 2022
  • This study aims to compare the healthcare status of South Korea and other member of the Organization for Economic Cooperation and Development (OECD) using the OECD health statistics 2021. We used the position value for relative comparison (PARC) index to measure the five elements of the healthcare system, demand, supply, accessibility, quality, and cost. For the statistical analysis, Mann-Kendall test was performed to examine the trend of the PARC values from 2000 to the most recent year. The results showed that supply, demand, accessibility, and quality were above median than the OECD median and the cost was below median. In sectors such as primary care, health employment and mental health care were below median average. With these result, necessary steps for a sustainable healthcare should be taken into effort by policy makers.

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

Evaluation of Best Value for Safety Facilities on Highway Using Risk-based VE Approach - A Case Study of Median Barrier - (위험도기반 가치공학적 기법을 적용한 고속도로 교통안전시설 최고가치평가 : 중앙분리대 적용사레를 중심으로)

  • Ji, Dong-Han;O, Young-Tae;Choi, Hyun-Ho;Kim, Sung-Hun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.1
    • /
    • pp.143-154
    • /
    • 2008
  • Since the concerns for safety of highway traffic safety facilities inherent in various environmental risk is increased, systematic performance, cost, and effect analysis process is needed for this. In case of median barrier among various traffic safety facilities, quantitative risk assessment is inevitable because it has lots of direct/indirect risk factors. Thus, this study suggests an advanced VE(Value Engineering) approach incorporating quantitative risk analysis. For the applicability, suggested VE approach considering alternative 1(140cm) and 2(127cm) is applied to median barrier in fields. Also, major improvement objects are extracted from governing factors of cost and performance based on functional analysis. It is concluded that the proposed risk assessment methodology will provide rational and practical solutions for best value and the approach could effectively applied for various traffic safety facilities by slight modification of suggest process.

Image Magnification Using Median Filter and Spatial Variation (메디안 필터와 공간 변화량을 이용한 영상 확대)

  • Kwak, Nae-Joung
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.9
    • /
    • pp.72-80
    • /
    • 2007
  • Image magnification is the estimation of a few pixel in images with high quality from a pixel of an image with low resolution and there have been studied many techniques to make images with high quality. In this paper, we propose an image interpolation method using median filter and spatial information. The proposed method makes an interpolating pixel using an average value of a median filtered value and an average value of two pixels correlated with an interpolating pixel tightly. Also we make the magnified image with improved quality to add the directional information of surrounding pixels and the characteristic of ones using average value and max value of spatial variation. We evaluate the performance using PSNR in the quality of enlarged image comparing the proposed method with existing methods. The results show the proposed method improves PSNR than the existing methods and make images preserving the characteristic of original imges.

An Electrophysiologic Study on the Median Motor Nerve and Ulnar Motor Nerve (정중운동신경과 척골운동신경의 전기생리학적 연구)

  • Kim, Jong-Soon;Lee, Hyun-Ok;Ahn, So-Youn;Koo, Bong-Oh;Nam, Kun-Woo;Kim, Young-Jick;Kim, Ho-Bong;Ryu, Jae-Kwan;Ryu, Jae-Moon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.62-70
    • /
    • 2005
  • The determination of peripheral nerve conduction velocity is an important part to electrodiagnosis. Its value as neurophysiologic investigative procedure has been known for many years but normal value of median and ulnar motor nerve was poorly reported in Korea. To evaluate of median and ulnar motor nerve terminal latency, amplitude of CMAP(compound muscle action potential), conduction velocity and F-wave latency for obtain clinically useful reference value. 71 normal volunteers(age, 19-65 years; 142 hands) examined who has no history of peripheral neuropathy, diabetic mellitus, chronic renal failure, endocrine disorders, anti-cancer medicine, anti-tubercle medicine, alcoholism, trauma, radiculopathy. Nicolet Viking II was use for detected terminal latency, amplitude of CMAP, conduction velocity and F-wave latency of median and ulnar motor nerve. Data analysis was performed using SPSS. Descriptive analysis was used for obtain mean and standard deviation, independent t-test was used to compare between Rt and Lt side also compare between different in genders. The results are summarized as follows: 1. Median motor nerve terminal latency was right 3.00ms, left 2.99ms and there was no significantly differences between right and left side and genders. 2. Median motor nerve amplitude of CMAP was right 17.26mV, left 1750mV and there was no significantly differences between right and left side and genders. 3. Median motor nerve conduction velocity was right 57.89m/sec, left 58.03m/sec and there was no significantly differences between right and left side and genders. 4. Median motor nerve F-wave latency was right 25.74ms, left 25.59ms and there was significantly differences between genders. 5. Ulnar motor nerve terminal latency was right 2.38ms, left 2.45ms and there was significantly differences between right and left side. 6. Ulnar motor nerve amplitude of CMAP was right 15.99mV, left 16.02mV and there was no significantly differences between right and left side and genders. 7. Ulnar motor nerve conduction velocity was right 60.35m/sec, left 59.73m/sec and there was no significantly differences between right and left side and genders. 8. Ulnar motor nerve F-wave latency was right 25.53ms, left 25.57ms and there was significantly differences between genders.

  • PDF

Termiticidal Activities of Chamaecyparis obtusa Endl. Heartwood (편백재의 흰개미 살충활성에 관한 연구)

  • Choi, In-Gyu;Kang, Ha-Young
    • Applied Biological Chemistry
    • /
    • v.43 no.1
    • /
    • pp.67-71
    • /
    • 2000
  • Termiticidal activities of Chamaecyparis obtusa were quantitatively evaluated, and the activity differences between supporting materials such as woodmeal and filter paper or between species were defined based on the termiticidal activity value(TAV). It was found that TAV was high in the following order ; C. obtusa>Litsea coreana>C. obtusa var. formosensis>Ternstroemia gymnanthera. In particular, termiticidal activity of C. obtusa heartwood was stronger by 5 to 9 times than that of other three species. Median survival dosage(MSD) of C. obtusa was 108.8 mg. In case of woodmeal or filter paper tests with C. obtusa, termiticidal activities were inversely proportional to logarithms values of an added sample weight and median survival time(MST). The difference of termiticidal activities between woodmeal and filter paper in the methanol extracts was small, but that in the neutral fraction was enormous as 3.21 times. However, termiticidal activity of neutral fraction was corresponded to 17 to 53% of original woodmeal, and 47 to 83% of termiticidal activity was considered as a loss in test process.

  • PDF

Validity and reproducibility of a food frequency questionnaire for breast cancer survivors in Korea

  • Sang-Eun, Moon;Woo-kyoung, Shin;Sihan, Song;Dahye, Koh;Jeong Sun, Ahn;Youngbum, Yoo;Minji, Kang;Jung Eun, Lee
    • Nutrition Research and Practice
    • /
    • v.16 no.6
    • /
    • pp.789-800
    • /
    • 2022
  • BACKGROUND/OBJECTIVES: The aim of this study was to examine the validity and reproducibility of a food frequency questionnaire (FFQ) developed in Korea for breast cancer survivors. SUBJECTS/METHODS: Ninety-nine breast cancer survivors who completed an FFQ twice and three 3-day dietary records (DRs) between 2016-2017 were included. Energy and 14 nutrient intakes were calculated from FFQs and DRs. To determine the validity of the FFQ, energy-adjusted de-attenuated Pearson correlations between two FFQ assessments and the average of the three 3-day DRs were calculated, and to determine reproducibility, energy-adjusted Pearson correlations and degrees of agreement were calculated between the first and second FFQ assessments. RESULTS: Correlation coefficients of validity ranged from 0.29 (protein) to 0.47 (fat) (median value = 0.36) for the FFQ assessment and from 0.20 (riboflavin) to 0.53 (calcium) (median value = 0.37) for the second. Correlation coefficients of reproducibility ranged from 0.22 (sodium) to 0.62 (carbohydrate) (median value = 0.36). Regarding FFQ reproducibilities, percentage classifications of exact agreements for energy-adjusted nutrients ranged from 27.3% (sodium) and 45.5% (fat). A median 76.8% of participants were classified into the same or adjacent quartiles, while a median of 5.6% of participants were classified in extreme quartiles. Bland-Atman plots for the majority of data points of three macronutrients, calcium and vitamins A and C fell within limits of agreement. CONCLUSIONS: These results indicated that the newly developed FFQ for Korean breast cancer survivors has acceptable validity and reproducibility as compared with three 3-day DRs collected over a one-year period.