• Title/Summary/Keyword: Median corrected

Search Result 33, Processing Time 0.022 seconds

The f0 distribution of Korean speakers in a spontaneous speech corpus

  • Yang, Byunggon
    • Phonetics and Speech Sciences
    • /
    • v.13 no.3
    • /
    • pp.31-37
    • /
    • 2021
  • The fundamental frequency, or f0, is an important acoustic measure in the prosody of human speech. The current study examined the f0 distribution of a corpus of spontaneous speech in order to provide normative data for Korean speakers. The corpus consists of 40 speakers talking freely about their daily activities and their personal views. Praat scripts were created to collect f0 values, and a majority of obvious errors were corrected manually by watching and listening to the f0 contour on a narrow-band spectrogram. Statistical analyses of the f0 distribution were conducted using R. The results showed that the f0 values of all the Korean speakers were right-skewed, with a pointy distribution. The speakers produced spontaneous speech within a frequency range of 274 Hz (from 65 Hz to 339 Hz), excluding statistical outliers. The mode of the total f0 data was 102 Hz. The female f0 range, with a bimodal distribution, appeared wider than that of the male group. Regression analyses based on age and f0 values yielded negligible R-squared values. As the mode of an individual speaker could be predicted from the median, either the median or mode could serve as a good reference for the individual f0 range. Finally, an analysis of the continuous f0 points of intonational phrases revealed that the initial and final segments of the phrases yielded several f0 measurement errors. From these results, we conclude that an examination of a spontaneous speech corpus can provide linguists with useful measures to generalize acoustic properties of f0 variability in a language by an individual or groups. Further studies would be desirable of the use of statistical measures to secure reliable f0 values of individual speakers.

Arterial Switch Operation in Complex Congenital Heart Diseaes (Application, procedure analysis,risk assessment,and results) (복잡 심기형에서의 동맥 전환술에 대한 연구)

  • 김용진
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.237-246
    • /
    • 1995
  • Between March 1989 and December 1994, one-stage repair was performed for correction of the intracardiac malformations associated with aortic coarctation in 34 patients or interrupted aortic arch in 8 patients via median sternotomy. There were 26 male and 16 female patients, and their body weight ranged from 1.8 to 8 kg [mean weight, 4.0 1.4 kg . The age at the operation ranged from 7 days to 18 months [mean age, 3.1 $\pm$ 3.8 months . The repair of aortic coarctation or interrupted aortic arch was performed using extended end-to-end anastomosis in most of the patients [86%, 36/42 , and six patients underwent ductal tissue excision and patch aortoplasty. Intracardiac defects were corrected concomitantly through the right atrium unless the anatomy dictated otherwise. Obstructive outlet septum was resected whenever necessary. There were seven early deaths [16.8 % , and three late deaths with a mean follow-up period of 25 months [range from 1 to 65 months . Three patients were reoperated upon residual subaortic stenosis, stenosis at the RPA origin, and subacute bacterial endocarditis respectively. None showed any significant residual or anastomotic stenosis postoperatively. One stage repair of the aortic coarctation and interrupted aortic arch associated with intracardiac defect leaves no native coarctation shelf tissue or residual hypoplasia in the repaired segment, has low incidence of recurrent or residual stenosis, minimizes reoperation and incisions, and manages arch hypoplasia easily. We concluded that surgical results of one-stage repair for the intracardiac malformation associated with aortic coarctation or interrupted aortic arch are reasonable.

  • PDF

A Study on Operation Technique and Effective Analysis of Expressway Variable Speed Limits Control (도시고속도로 가변속도제어 운영방안과 효과분석)

  • Im, Gwan-Su;Nam, Du-Hui
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.2
    • /
    • pp.7-14
    • /
    • 2011
  • This paper discusses operational technique and effectiveness of Variable Speed Limits system that is implemented to control the traffic-flow on the Naebu Expressway. As the first step of the analysis, traffic data collected from vehicle detectors are corrected and smoothed. Applying a pattern analysis technique to the traffic data, the weekday traffic is classified into four different groups, and median of each group is calculated. Using three state variables, i.e., diverted traffic volume, average density and average speed, the conditions of roadway segments are determined. Computational outputs resulted from the application of the proposed model to the scenarios show that implementation of Variable Speed Limits system improved both safety and efficiency of the expressway. For the operational strategy, this paper also presents the change rate of the speed limit, and the effective duration of the speed limit according to the entering traffic volume.

Correction Method for Measurement Failure Pixels in Depth Picture using Surface Modeling (표면 모델링을 통한 깊이 영상 내 측정 실패 화소 보정 방법)

  • Lee, DongSeok;Kwon, SoonKak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.5
    • /
    • pp.1-8
    • /
    • 2019
  • In this paper, we propose a correcting method of depth pixels which are failed to measure since temporary camera error. A block is modeled to plane and sphere surfaces through measured depth pixels in the block. Depth values in the block are estimated through each modeled surface and a error for the modeled surface is calculated by comparing the original and estimated pixels, then the surface which has the least error is selected. The pixels which are failed to measure are corrected by estimating depth values through selected surface. Simulation results show that the proposed method increases the correction accuracy by an average of 20% compared with the correction method of $5{\times}5$ median method.

Extracorporeal Membrane Oxygenation in Pediatric Patients with Respiratory Failure: Early Experience with the Double-Lumen Cannula Over 2 Years

  • Kim, Woojung;Kwon, Hye Won;Min, Jooncheol;Cho, Sungkyu;Kwak, Jae Gun;Kim, Woong Han
    • Journal of Chest Surgery
    • /
    • v.53 no.3
    • /
    • pp.132-139
    • /
    • 2020
  • Background: The double-lumen cannula (DLC) has begun to be used worldwide for venovenous (VV) extracorporeal membrane oxygenation (ECMO). We aimed to examine whether the DLC could be an effective tool in the treatment of pediatric respiratory failure in Korea. Methods: We reviewed the records of patients weighing under 15 kg who underwent ECMO due to respiratory failure between January 2017 and December 2018. Outcomes of ECMO using a DLC and conventional ECMO using central method or 2 peripheral cannulas were compared. Results: Twelve patients were treated with ECMO for respiratory failure. Among them, a DLC was used in 5 patients, the median age of whom was 3.8 months (interquartile range, 0.1-49.7 months). In these patients, the median values of pH, partial pressure of carbon dioxide, and partial pressure of oxygen were 7.09, 74 mm Hg, and 37 mm Hg before ECMO and corrected to 7.31, 44 mm Hg, and 85 mm Hg, respectively, after ECMO cannulation. Median blood flow rate in the patients treated with ECMO using a DLC was slightly higher than that in the conventional ECMO group, but this difference was not statistically significant (86.1 mL/kg/min and 74.3 mL/kg/min, respectively; p=1.00). One patient from the DLC group and 3 patients from the conventional group were weaned off ECMO. Conclusion: VV ECMO using a DLC provided adequate oxygenation, ventilation, and blood flow rate in Korean pediatric patients with respiratory failure. Further prospective and randomized studies are warranted.

Continuous renal replacement therapy in neonates weighing less than 3 kg

  • Sohn, Young-Bae;Paik, Kyung-Hoon;Cho, Hee-Yeon;Kim, Su-Jin;Park, Sung-Won;Kim, Eun-Sun;Chang, Yun-Sil;Park, Won-Soon;Choi, Yoon-Ho;Jin, Dong-Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.8
    • /
    • pp.286-292
    • /
    • 2012
  • Purpose: Continuous renal replacement therapy (CRRT) is becoming the treatment of choice for supporting critically ill pediatric patients. However, a few studies present have reported CRRT use and outcome in neonates weighing less than 3 kg. The aim of this study is to describe the clinical application, outcome, and complications of CRRT in small neonates. Methods: A retrospective review was performed in 8 neonatal patients who underwent at least 24 hours of pumped venovenous CRRT at the Samsung Medical Center in Seoul, Korea, between March 2007 and July 2010. Data, including demographic characteristics, diagnosis, vital signs, medications, laboratory, and CRRT parameters were recorded. Results: The data of 8 patients were analyzed. At the initiation of CRRT, the median age was 5 days (corrected age, $38^{+2}$ weeks to 23 days), and the median body weight was 2.73 kg (range, 2.60 to 2.98 kg). Sixty-two patient-days of therapy were reviewed; the median time for CRRT in each patient was 7.8 days (range, 1 to 37 days). Adverse events included electrolyte disturbances, catheter-related complications, and CRRT-related hypotension. The mean circuit functional survival was $13.9{\pm}8.6$ hours. Overall, 4 patients (50%) survived; the other 4 patients, who developed multiorgan dysfunction syndrome, died. Conclusion: The complications of CRRT in newborns are relatively high. However, the results of this study suggest that venovenous CRRT is feasible and effective in neonates weighing less than 3 kg under elaborate supportive care. Furthermore, for using potential benefit of CRRT in neonates, efforts are required for prolonging filter survival.

Evaluation of Conotruncal Anomalies by Electron Beam Tomography (Conotruncal 기형 평가에서 전자선 단층 촬영 (EBT)의 정확성)

  • 최병욱;박영환;최병인;최재영;김민정;유석종;이종균;설준희;이승규
    • Journal of Chest Surgery
    • /
    • v.33 no.4
    • /
    • pp.290-300
    • /
    • 2000
  • Background: To evaluate the diagnostic accuracy of EBT(Electron Beam Tomography) in the diagnosis of conotruncal anomaly and to determine whether it can be used as a substitute for cardiac angiography. Material and Method: 20 patients(11M & 9F) with TOF(n=7, pulmonary atresia 2), DORV(n=7), complete TGV(n=4), & corrected TGV(n=2) were included. The age ranged from 7 days to 26 years(median 60 days). We analyzed the sequential chamber localization, the main surgical concenrn in each disease category (PA size, LVED volume and coronary artery pattern for TOF & pulmonary atresia, the LV mass, LVOT obstruction, coronary artery pattern for complete TGV, and type of VSD and TV-PV distance for DORV, etc) and other associated anomalies(e.g., VSD, arch anomalies, tracheal stenosis, etc). Those were compared with the results of echocardiography(n=19), angiography (n=9), and surgery(n=11). The interval between EBT and echocardiography/angiography was within 20/11 days, respectively except for an angiography in a patient with corrected TGV (48 days). Result: EBT correctly diagnosed the basic components of conotruncal anomalies in all subjects, compared to echocardiography, angiography or surgery. These included the presence, type and size of VSD(n=20), pulmonic/LV outflow tract stenosis(n=15/2), relation of great arteries and the pattern of the proximal epicardial coronary arteries(16 out of 20). EBT proved to be accurate in quantitation of the intrapericardial and hilar pulmonary arterial dimension and showed high correlation and no difference compared with echocardiography, angiography, or surgery(p>0.05) except for left pulmonary arterial & ascending arterial dimension by echocardiography. LVED volume in seven TOF(no difference: p>0.05 & high correlation: r=0.996 with echocardiography), and LV mass in 4 complete TGV were obtained. Additionally, EBT enabled the cdiagnosis of subjlottic tracheal stenosis and tracheal bronchus in 1 respectively. Some peripheral PA stenosis were not detected by echocardiography, while echocardiography appeared to be slightly more accurate than EBT in detecing ASD or PDA. Conclusion: EBT can be a non-invasive and accurate modality of for the evaluation of most anatomical alteration including peripheral PS or interruption in patients with conotruncal anomalies. Combined with echocardiography, EBT study provides sufficient information for the palliative or total repair of anomalies.

  • PDF

Correction of Retracted Ala Using Spacer Graft in Secondary Cleft Lip and Nose Deformity (이차 구순비 변형 환자에서 Spacer Graft를 이용한 콧방울뒤당김(retracted ala)의 교정)

  • Han, Kyu-Seok;Choi, Hyun-Gon;Shin, Dong-Hyeok;Kim, Soon-Heum;Hwang, Eun-A;Uhm, Ki-Il
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.376-382
    • /
    • 2011
  • Purpose: In patients with unilateral cleft lip and nose deformity, alar retraction is commonly seen on the non-cleft side after cleft side is corrected. Spacer graft was used to drag down the inferior border of the alar cartilage of the non-cleft side so as to match the cleft side. By performing spacer graft and septal extension graft together, symmetry and cosmetic improvements were achieved. Methods: Seven unilateral cleft lip and nose deformity patients underwent surgery for alar retraction correction. The median age was 24 years (ranged from 15 to 34 years), and the median follow-up period was 7.4 months (ranged from 6 to 12 months). The perpendicular length from the longitudinal axis of the nostril to the alar rim, the nasolabial angle and the ala-labial angle were measured in the lateral view photo. The longest perpendicular length from the cephalic border of the alar rim to the parallel line of the alar base was measured in the frontal view photo. Results: Improvement in alar retraction was seen after the surgery. There were no specific complications during the follow-up and the symmetry of both nostrils was satisfactory. No increase in the nasolabial angle or exposure of the nostrils was seen after the tip projection via tip plasty. Conclusion: The fundamental factor in correcting alar retraction with secondary cleft lip and nose deformity is repositioning the alar rim with spacer graft, which seems to be more physiologic than other methods. The method combining spacer graft with septal extension graft will bring symmetry as well as more cosmetic improvement in correction of alar retraction with secondary cleft lip and nose deformity.

Repair of the Cleft Lip using Triangular Cheiloplasty-A Case Report (삼각피판법을 이용한 편측 불완전 구순열 환자의 구순 교정 수술-증례 보고)

  • Song, In-Seok;Hong, Jong-Rak;Choung, Pil-Hoon;Seo, Byoung-Moo
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.10 no.2
    • /
    • pp.67-74
    • /
    • 2007
  • After Tennison introduced a triangular flap method which, for the first time, preserved the Cupid's bow, Randall gave this method a sound mathematical basis. This method is also called as an inferior triangular cheiloplasty which is characterized by making a small triangular flap from the lateral border of cleft destined to be fitted into an incision on the medial side of cleft. He postulated that the height obtained was equal to the sum of the median of the two triangles used in the cheiloplasty. Using this technique, a 22 month-old male patient with incomplete unilateral cleft lip was corrected primarily. The deviation of the columella and flattening of the nostril on the cleft side were minimal. The operation was done under general anesthesia and patient was healed uneventfully. We tried to improve the symmetry and esthetic feature of philtrum, nostril sill, alar-facial groove, preventing the notch formation on the nostril floor, and to reconstruct the muscle sling in the upper part of lip. The shape of Cupid's bow was restored, and the symmetry of columella was regained as a result. In summary, the inferior triangular cheiloplasty is effective to correct the primary unilateral cleft lip, results in the restoration of favorable anatomy and function.

  • PDF

Document Image Layout Analysis Using Image Filters and Constrained Conditions (이미지 필터와 제한조건을 이용한 문서영상 구조분석)

  • Jang, Dae-Geun;Hwang, Chan-Sik
    • The KIPS Transactions:PartB
    • /
    • v.9B no.3
    • /
    • pp.311-318
    • /
    • 2002
  • Document image layout analysis contains the process to segment document image into detailed regions and the process to classify the segmented regions into text, picture, table or etc. In the region classification process, the size of a region, the density of black pixels, and the complexity of pixel distribution are the bases of region classification. But in case of picture, the ranges of these bases are so wide that it's difficult to decide the classification threshold between picture and others. As a result, the picture has a higher region classification error than others. In this paper, we propose document image layout analysis method which has a better performance for the picture and text region classification than that of previous methods including commercial softwares. In the picture and text region classification, median filter is used in order to reduce the influence of the size of a region, the density of black pixels, and the complexity of pixel distribution. Futhermore the classification error is corrected by the use of region expanding filter and constrained conditions.