• Title/Summary/Keyword: Media Flow

Search Result 944, Processing Time 0.029 seconds

Olfactory Interaction based on ISO/IEC 23005 Standard

  • Choi, Jang-Sik;Chang, Sung-June;Lee, Hae-Ryong;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.297-300
    • /
    • 2017
  • Realistic media comprised of metadata of the five senses to provide enhanced experiences by stimulating our memory and sensations have had an increasingly pervading effect in our daily lives. Many researchers and companies are in the process of developing their own authoring systems running on different platforms to serve realistic media, resulting in compatibility issues among the systems. To tackle these issues, the International Organization for Standardization have standardized the interface, data format, protocol, API, etc. required to provide the realistic media. In particular, the ISO/IEC 23005 standard, which is called MPEG-V in SC29/WG 11, has defined XML schemas for olfaction interaction based on electronic nose (E-Nose), and scent display. In this paper, the MPEG-V standard for olfaction interaction is reviewed, and a data flow diagram that can be used for olfactory interaction based on the MPEG-V standard was designed. In addition, the necessary schemas related to the E-Nose sensor for olfactory interaction was provided.

Biofiltration of Ammonia Gas from Composting Using Sawdust as Biofilter Media (퇴비화 암모니아 가스의 톱밥 바이오 필터 매체에 의한 생물학적 탈취)

  • Hong Ji Hyung;Park Keum Joo
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.107-115
    • /
    • 2003
  • Dairy manure amended with crop and forest residues (moisture 69% wet basis, C/N 22) was composted in a 605 L pilot-scale vessel using continuous air flow (56 L/min) for 19 days. Three pilot-scale sawdust biofilters (moisture 63%, pH 5.0) were built to clean biological waste gas from the composting process. For each methods, two replicated experiments were monitored over a period of three weeks. The system was evaluated to determine the biofilter media depth that would be adequate for compost odour reduction. The compost air cleaning was measured based on ammonia gas concentration before and after passing through the biofilter. Ammonia gas removal efficiency over 3 weeks was 42, 75 and 87% at sawdust biofilter media depth levels of 202, 400 and 600 mm, respectively. Each sawdust biofilter was operated at a moisture content in the range of 60~62% (wb), a temperature from 15 to $25^{\circ}C$, an average pressure drop from 240 to 340 Pa and a detention time from 60 to 180 seconds during the biofiltration process.

Basic Experiment on the Propagation Characteristics of Premixed Flames in Narrow Annular Coaxial Quartz Tubes (좁은 다중 동축 석영관 내부에서의 예혼합 화염의 전파 특성에 대한 기초 실험)

  • Cho, Moon Soo;Baek, Da Bin;Kim, Nam Il
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.2
    • /
    • pp.1-7
    • /
    • 2013
  • Flame stabilization characteristics of premixed flames in narrow annular coaxial tubes (NACT) were investigated experimentally. The NACT burner was proposed as a model of a cylindrical refractory burner, and it was made of quartz tubes. Flame stabilization conditions affected by the characteristic length of the burner was investigated with the variation of the equivalence ratio and the flow rates. Flame behaviors in narrow spaces could be directly observed. Conclusively, more wide flame stabilization conditions could be obtained at the case of the decreased channel scale. A flame instability, such as combustion noise was detected concerned with the flame oscillation observed at the surface of multi channel stage. Some flame propagation characteristics had complicated tendencies that may exist in practical porous-media combustors. Therefore, this NACT burner can be a basic configuration for the development of flame stabilization model in porous media combustor, and it will enhance our understanding about the behavior of flames in meso-scale combustion spaces.

A comparative study of granular activated carbon and sand as water filtration media with estimation of model parameters

  • Chatterjee, Jaideep;A, Shajahan;Pratap, Shailendra;Gupta, Santosh Kumar
    • Advances in environmental research
    • /
    • v.6 no.1
    • /
    • pp.35-51
    • /
    • 2017
  • The use of Granular Activated Carbon (GAC) and naturally occurring silica (Sand) as filtration media in water and waste water treatment systems is very common. While GAC offers the additional functionality of being an "adsorptive" filter for dissolved organics it is also more expensive. In this paper we present an experimental evaluation of the performance of a bed of GAC for colloid removal and compare the same with that from an equivalent bed of Sand. The experiments are performed in an "intermittent" manner over extended time, to "simulate" performance over the life of the filter bed. The experiments were continued till a significant drop in water flow rate through the bed was observed. A novel "deposition" and "detachment" rate based transient mathematical model is developed. It is observed that the data from the experiments can be explained by the above model, for different aqueous phase electrolyte concentrations. The model "parameters", namely the "deposition" and "detachment" rates are evaluated for the 2 filter media studied. The model suggests that the significantly better performance of GAC in colloid filtration is probably due to significantly lower detachment of colloids from the same. While the "deposition" rates are higher for GAC, the "detachment" rates are significantly lower, which makes GAC more effective than sand for colloid removal by over an order of magnitude.

Development of an Evaluation Method for the Flow Rate Performance of Gas Sampling Pumps Using Adsorbent Tubes (흡착튜브를 이용한 가스상물질 채취용 펌프의 유량성능 평가방법)

  • Kim, Nam Hee;Song, Ho June;Kim, Ki Youn;Ma, Hye Lan;Yi, Gwang Yong;Jeong, Jee Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.201-207
    • /
    • 2014
  • Objectives: Flow rate stability is very important for obtaining reliable measurements. However there is no easily used method for checking whether the flow rate set at the initial stage is sustained during sampling. The purpose of this study was to develop a method to evaluate the flow rate performance of gas sampling pumps with adsorbents commonly used to sample gases. Materials and methods: We tested the back pressure of gas sampling pumps commonly used in Korea with adsorbents such as charcoal and silica tubes and attempted to discover the combination conditions of adsorbents in accordance with back pressure required by ISO standard 13137. Results: We found the combination of sampling adsorbents to be applicable to the pressure drop required by the ISO standard for evaluating flow rate stability under increasing pressure drop and long term (eight-hour) performance. Conclusions: This evaluation method of using a sampling media matrix for checking flow rate stability as proposed by this study could be a highly useful tool for determining the reliability of the performance pumps before sampling.

Filter- and Denuder-Based Organic Carbon Correction for Positive Sampling Artifacts

  • Hwang, InJo;Na, Kwangsam
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.107-113
    • /
    • 2017
  • This study describes (1) the impact of positive sampling artifacts caused by not only a filter-based sampling, but also a denuder-based sampling in the determination of particle-phase organic carbon (POC), (2) the effect of sample flow rate on positive artifacts, and (3) an optimum flow rate that provides a minimized negative sampling artifact for the denuder-based sampling method. To achieve the goals of this study, four different sampling media combinations were employed: (1) Quartz filter-alone (Q-alone), (2) quartz filter behind quartz-fiber filter (QBQ), (3) quartz filter and quartz filter behind Teflon filter (Q-QBT), and (4) quartz filter behind carbon-based denuder (Denuder-Q). The measurement of ambient POC was carried out in an urban area. In addition, to determine gas-phase OC (GOC) removal efficiency of the denuder, a Teflon filter and a quartz filter were deployed upstream and downstream of the denuder, respectively with varying sample flow rates: 5, 10, 20, and 30 LPM. It was found that Q-alone sampling configuration showed a higher POC than QBQ, Q-QBT, and Denuder-Q by 12%, 28%, and 23%, respectively at a sample flow rate of 20 LPM due to no correction for positive artifact caused by adsorption of GOC onto the filter. A lower quantity of GOC was collected from the backup quartz filter on QBQ than that from Q-QBT. This was because GOC was not in equilibrium with that adsorbed on the front quartz filter of QBQ during the sampling period. It is observed that the loss of particle number and mass across the denuder increases with decreasing sample flow rate. The contribution o f positive arti facts to POC decreased with increasing sample flow rate, showing 29%, 25%, and 22% for 10, 20, and 30 LPM, respectively. The 20 LPM turns out to be the optimum sample flow rate for both filter and denuder-based POC sampling.

Flow Lab. : Flow Visualization and Simulation (핵종이동 가시적 현상관찰및 수치모사)

  • Park Chung-Kyun;Cho Won-Jin;Hahn Pi1-Soo
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.134-142
    • /
    • 2005
  • The experimental setups for flow visualization and processes identification in laboratory scale (so cal led Flow Lab.) has developed to get ideas and answer fundamental questions of flow and migration in geologic media. The setup was made of a granite block of $50{\times}50cm$ scale and a transparent acrylate plate. The tracers used in this experiments were tritiated water, anions, and sorbing cations as well as an organic dye, eosine, to visualize migration paths. The migration plumes were taken with a digital camera as a function of time and stored as digital images. A migration model was also developed to describe and identify the transport processes. Computer simulation was carried out not only for the hydraulic behavior such as distributions of pressure and flow vectors in the fracture but also for the migration plume and the elution curves.

  • PDF

A study on determinants of flow status in smoking simulation game (흡연시뮬레이션 게임에서 몰입 결정요인에 대한 연구)

  • Jang, Han-Jin;Noh, Ghee-Young
    • Journal of Korea Game Society
    • /
    • v.17 no.2
    • /
    • pp.165-174
    • /
    • 2017
  • This research was conducted to find out determinant variables which can influence the degree of flow in smoking simulation game. We set up flow experience as a dependent variable. Several factors including empathy, health concern, and brainwave(${\alpha}$, ${\beta}$) EEG(Electroencephalogram) as a physiological indicator, which was expected to affect flow, were set up as independent variables to perform regression analysis. As a result, empathy, health consciousness, and ${\beta}$ wave had positive influences on flow in smoking simulation game but ${\alpha}$ wave had negative effect. This research empirically analyzed users' experience and neurophysiological changes which can influence on flow in serious game and contributed to theoretical and methodological development in health-related game research.

Expansion of the Darcy-Weisbach Relation for Porous Flow Analysis (다공질 유동해석을 위한 Darcy-Weisbach 관계식의 확장)

  • Shin, Chang Hoon;Park, Warn Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.4
    • /
    • pp.229-238
    • /
    • 2017
  • This study started to deduce a permeability relationship that can consider the geometric features of various porous media under different flow regimes. With reference to the previous works of Kozeny and Carman, the conventional Darcy-Weisbach relation (Darcy's friction flow equation) was reviewed and expanded for porous flow analysis. Based on the capillary model, this relation was transformed to the friction equivalent permeability (FEP) definition. The validity of the FEP definition was confirmed by means of comparison with the Kozeny-Carman equation. Hereby, it was shown that the FEP definition is the generalized form of the Kozeny-Carman equation, which is confined to laminar flow through a circular capillary. In conclusion, the FEP definition as a new permeability estimation method was successfully developed by expanding the Darcy-Weisbach relation for porous flow analyses.

Simulation of Groundwater Flow in Fractured Porous Media using a Discrete Fracture Model (불연속 파쇄모델을 이용한 파쇄 매질에서의 지하수 유동 시뮬레이션)

  • Park, Yu-Chul;Lee, Kang-Kun
    • Economic and Environmental Geology
    • /
    • v.28 no.5
    • /
    • pp.503-512
    • /
    • 1995
  • Groundwater flow in fracture networks is simulated using a discrete fracture (DF) model which assume that groundwater flows only through the fracture network. This assumption is available if the permeability of rock matrix is very low. It is almost impossible to describe fracture networks perfectly, so a stochastic approach is used. The stochastic approach assumes that the characteristic parameters in fracture network have special distribution patterns. The stochastic model generates fracture networks with some characteristic parameters. The finite element method is used to compute fracture flows. One-dimensional line element is the element type of the finite elements. The simulation results are shown by dominant flow paths in the fracture network. The dominant flow path can be found from the simulated groundwater flow field. The model developed in this study provides the tool to estimate the influences of characteristic parameters on groundwater flow in fracture networks. The influences of some characteristic parameters on the frcture flow are estimated by the Monte Carlo simulation based on 30 realizations.

  • PDF