• 제목/요약/키워드: Med-infrared

검색결과 8건 처리시간 0.03초

적외선 체온의 진단 정확도 평가 연구: 체계적 문헌고찰 (Reliability and Accuracy of Infrared Temperature: A Systematic Review)

  • 박성희
    • 성인간호학회지
    • /
    • 제26권6호
    • /
    • pp.668-680
    • /
    • 2014
  • Purpose: The aim of this study was to investigate the accuracy of infrared temperature measurements compared to axillary temperature in order to detect fever in patients. Methods: Studies published between 1946 and 2012 from periodicals indexed in Ovid Medline, Embase, CINAHL, Cochrane, KoreaMed, NDSL, KERIS and other databases were selected using the following key words: "infrared thermometer". QUADAS-II was utilized to assess the internal validity of the diagnostic studies. Selected studies were analyzed through a meta-analysis using MetaDisc 1.4. Results: Twenty-one diagnostic studies with high methodological quality were included representing 3,623 subjects in total. Results of the meta-analysis showed that the pooled sensitivity, specificity, and area under the curve (AUC) of infrared tympanic thermometers were 0.73 (95% CI 0.70~0.75), 0.92 (95% CI 0.91~0.92), and 0.90, respectively. For axillary temperature readings, the pooled sensitivity was 0.67 (95% CI 0.62~0.73), the pooled specificity was 0.87 (95% CI 0.85~0.90), and the AUC was 0.80. Conclusion: Infrared tympanic temperature can predict axillary temperature in normothermic and in febrile patients with an acceptable level of diagnostic accuracy. However, further research is necessary to substantiate this finding in patients with hyperthermia.

아동에서의 적외선 체온 측정의 진단정확도 연구 : 체계적 문헌 고찰과 메타분석 (Systematic Review and Meta-Analyses of Diagnostic Accuracy of Infrared Thermometer when Identifying Fever in Children)

  • 박영주;박성희;강창범
    • 대한간호학회지
    • /
    • 제43권6호
    • /
    • pp.746-759
    • /
    • 2013
  • Purpose: Infrared thermometers are increasingly used as a convenient, non-invasive assessment method for febrile children. However, the diagnostic accuracy of the infrared thermometer for children has been questioned, particularly in relation to sensitivity and specificity. The aim of this study was to evaluate diagnostic accuracy of infrared thermometers in febrile children. Methods: Articles published between 1966 and 2012 from periodicals indexed in the Ovid Medline, Embase, CINAHL, Cochrane, KoreaMed, NDSL, KERIS and other databases were selected, using the following keywords: 'infrared thermometer'. The QUADAS-II was applied to assess the internal validity of the diagnostic studies. Selected studies were analyzed using meta-analysis with MetaDisc 1.4. Results: Nineteen diagnostic studies with high methodological quality, involving 4,304 children, were included. The results of meta-analysis showed that the pooled sensitivity, specificity and AUC (Area Under the Curve) of infrared tympanic thermometers in children over 1 year were 0.80 (95% CI 0.78, 0.81), 0.94 (95% CI 0.93, 0.95) and 0.95 respectively. However the diagnostic accuracy of infrared tympanic thermometers in children with hyperthermia was low. Conclusion: The diagnostic accuracy of infrared tympanic thermometer was similar to axillary and rectal thermometers indicating a need for further research to substantiate these findings in children with hyperthermia.

위상잠금 중파장 적외선 열화상 기법에 의한 결함 계측에서 측정 대상체의 재질에 따른 위상잠금 주파수 연구 (Determination of Lock-in Frequency in Accordance with Material of Target for Defect Measuring by Lock-in Mid-IR Thermography)

  • 박일철;김상채;이항서;김한섭;정현철;김경석
    • 한국기계가공학회지
    • /
    • 제18권9호
    • /
    • pp.44-51
    • /
    • 2019
  • Three types of samples with defects were measured by lock-in med-IR (infrared) thermography with various lock-in frequencies for different materials. The lock-in method can be used to detect defects when an external energy source is applied to the object, the non-uniformity of the incident thermal energy distribution is eliminated, and the camera's measurement cycle is synchronized with the load cycle of the incident energy source. For inspecting samples with defects, results of thermal images are analyzed when three types of materials, i.e., SM45C, STS316L, and AL6061 are tested and three lock-in frequencies, i.e., 0.08, 0.1, and 0.12 Hz are applied. In this study, the optimal lock-in frequencies were determined by comparing the results of each material and lock-in frequency measured using the mid-IR camera.

늑골골절의 한의학적 치료에 대한 최신 연구동향: China National Knowledge Infrastructure (CNKI), PubMed를 중심으로 (The Latest Research Trend on Korean Medicine of Rib Fractures: Focused on China National Knowledge Infrastructure (CNKI), PubMed)

  • 박은상;황현호;박기현;김호걸;임지성;강준혁
    • 한방재활의학과학회지
    • /
    • 제32권4호
    • /
    • pp.47-60
    • /
    • 2022
  • Objectives The purpose of this study is to identify the latest research trends regarding the nonsurgical treatment of rib fractures and suggest the direction for future research. Methods We searched for papers published from January 1, 2015 to July 1, 2022 in PubMed and the China National Knowledge Infrastructure (CNKI) based on keywords 'rib fracture'. 'Korean medicine', 'oriental medicine', 'TCM', 'moxibustion', 'acupunture', 'cupping', 'electroacupuncture', 'pharmacopuncture', 'fire needling'. Results A total of 79 studies were searched at first research. Then the studies were screening according to criteria and Finally 20 studies were selected. The oriental medical interventions analyzed in this study were fumigation method, herbal medicine, external application, acupuncture, ointment, herb fomentation, Tending Diancibo Pu far-infrared therapy. Conclusions Various oriental medical interventions such as herbal medicine, acupuncture, fumigation, herb fomentation, ointment, and physical therapy are being studied abroad for the treatment of rib fractures. It is considered that additional research related to the nonsurgical treatment for rib fractures is needed in the future in korea.

Photobiomodulation Therapy in Recovery of Peripheral Facial Nerve Damage

  • Choi, Ji Eun
    • Medical Lasers
    • /
    • 제9권2호
    • /
    • pp.89-94
    • /
    • 2020
  • Photobiomodulation (PBM) therapy has been investigated to enhance and accelerate the recovery of injured peripheral nerves. Based on the wide range of benefits of PBM therapy and its clinical relevance, this study reviewed the efficacy of PBM in injured facial nerves. The search was performed in the PubMed database to find relevant articles published over the last 10 years. Four animal studies, two randomized controlled studies, one case series, and five case reports were reviewed. Despite the various parameters, functional analysis showed that PBM therapy using near-infrared irradiation has beneficial effects on the recovery of the acute phase of the damaged facial nerve, especially when related to faster functional improvement. There were no reported adverse effects of PBM therapy.

성장판의 성장에 저단계 레이저가 미치는 영향에 대한 고찰 (Review of Low Level Laser Therapy on The Growth of Epiphyseal Plate)

  • 최지원;장인수;정민정
    • 대한한방소아과학회지
    • /
    • 제29권4호
    • /
    • pp.29-38
    • /
    • 2015
  • Objectives We aimed to identify the effectiveness of photobiomodulation using low level laser therapy (LLLT), light emitting diode (LED) and others on the growth of the length of the growth plate by reviewing literatures. Methods We searched literatures using PubMed, Science Direct, CINAHL, Korea Traditional Knowledge Portal (KTKP), Oriental Medicine Advanced Searching Integrated System (OASIS), China Knowledge Resource Integrated Database (CNKI), Japan Science and Technology Information Aggregator, Electronic (J STAGE), and Japan National Institute of Informatics Scholarly and Academic Information Navigator (CiNii) using the keywords "Growth plate" "Epiphyseal growth" "Epiphyseal plate" and "Laser", "light emitting diode (LED)", "near-infrared light", and "photobiomodulation". Search range included only original article which provided English abstract were selected. The search strategy contained no language limitation. Results A total 556 studies were found. Then, 551 were excluded by scanning titles and abstracts and finally 5 articles were selected. Five articles were RCTs using rodents. Two of the 5 articles used InGaAlP Laser (630-685 nm), and the other 3 articles used GaAlAs Laser (780, 820, and 870 nm) to investigated the effects of LLLT on the growth of the length of the epiphyseal cartilage and the number of chondrocytes and thickness of each zone of the epiphyseal cartilage. Two articles concluded that LLLT had a beneficial effect on the longitudinal growth of the growth plate. In growth of the epiphyseal plate, there were no significant differences in others. Conclusions It is might that LLLT influenced on the growth of epiphyseal plate by positive affect. However, further rigorous RCTs are warranted.

조직 재생을 위한 Poly (D, L-lactide-co-glycolide) 표면에 $(1{\to}3)(1{\to}6)-{\beta}-glucan$ 고정에 대한 세포 점착 및 성장 효과 (Surface Immobilization of $(1{\to}3)(1{\to}6)-{\beta}-glucan$ onto Biodegradable Polymer for Tissue Regeneration)

  • 이상길;이정복;유성미;박종철;최재봉;김정구
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권5호
    • /
    • pp.218-223
    • /
    • 2006
  • We examined the effects of ${\beta}$-glucan-reinforced PLGA film and scaffold on HDFs (human dermal fibroblast) attachment and proliferation. The PLGA films were prepared by simple solvent-casting method. The prepared films were grafted with $(1{\to}3)(1{\to}6)-{\beta}-glucan$ in various ratios after plasma treatment on surface. The surface of the film was characterized by contact angle measurement, scanning electron microscope (SEM), and Fourier-transform infrared spectrophotometer (FT-IR). The amount of $(1{\to}3)(1{\to}6)-{\beta}-glucan$ in the prepared film was indirectly determined by phenol-sulfuric acid method. The HDFs (Human dermal fibroblasts) were used to evaluate the cell attachment and proliferation on PLGA specimens before and after plasma/${\beta}-glucan$ treatment. The result showed that the plasma treated groups exhibited more mont of ${\beta}-glucan$ might be grafted than the non plasma treated groups. Cell attachment was significantly enhanced in the plasma/${\beta}-glucan$ grafted group after 4 hours incubation (p<0.05) due to the improved hydrophilicity and cytoactivity effect of the ${\beta}-glucan$. The cell proliferation of plasma/${\beta}-glucan$ (2mg/ml) grafted group was the highest rate among the groups (p<0.05).

흉요추 압박 골절의 한의학적 치료에 대한 국내 임상 근거 : 체계적 문헌 고찰 (Korean Medicine for Thoracolumbar Compression Fracture in Korean Literature : a Systematic Review)

  • 배지민;김대훈;김재규;이병렬;양기영;김건형
    • Journal of Acupuncture Research
    • /
    • 제32권4호
    • /
    • pp.147-156
    • /
    • 2015
  • Objectives : This study aims to evaluate the effectiveness and safety of Korean medicine for a thoracolumbar compression fracture. Methods : We searched six Korean databases (DBPIA, Korean Studies Information Service System, Oriental Medicine Advanced Searching Integrated System, National Digital Science Library, Research Information Sharing Service, KoreaMed) (up to June 2015) and the Journal of Korean Acupuncture and Moxibustion Society. Unpublished studies were also searched. Clinical research, other than case reports involving less than 10 patients, were eligible. The effectiveness and safety of Korean Medicine was analyzed. The 'Risk of Bias' was assessed using the 'Risk of Bias' assessment tool for non-randomized studies as well as the Cochrane Collaboration's 'Risk of Bias' tool. Results : We found 12 before-after studies (374 patients). There was no randomized trial. All studies combined at least three different types of Korean medicine treatments. The period of treatment varied between less a week and 154 days. All the included studies reported improvements in pain, functional disability related to lower back pain, global assessment, and benefits in the compression ratio of a fractured vertebrae and skin temperature measured by digital infrared thermal imaging in comparison with the baseline. However, all studies had a high risk of bias and three studies reported mild adverse events. Conclusions : There is no randomized trial for the role of Korean medicine for patients with a thoracolumbar compression fracture. The effectiveness and safety of Korean medicine for this population remains unclear. Findings in this review are seriously biased due to observational design and a high risk of bias included in the studies. Future high-quality randomized trials are warranted.