• Title/Summary/Keyword: Mechanical test method

Search Result 3,144, Processing Time 0.037 seconds

An Estimation on the Applicability of Hollow FRP Soil Nailing System (중공식 FRP쏘일네일링 시스템의 적용성 평가)

  • Lee, Hyuk-Jin;Koh, Hyung-Seon;Han, Yong-Hee;Kim, Hong-Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6C
    • /
    • pp.385-393
    • /
    • 2006
  • Soil nailing is a reinforcement method used for stabilizing excavated walls or slopes. Due to its much advantages such as ease of construction and economical efficiency, use of soil nailing is increased. However, the soil nail has much disadvantages for use in urban area. The soil nail needs to be installed inevitably beyond private land boundary, which causes rent for use. For this reason, removable soil nailing system was developed. However, the removal rate of this system is just about 50¢¦70%. To resolve this problem, the Fiber Reinforced Plastic (FRP) soil nailing system which does not need to be removed and allows for the installation beyond private land, is developed. In this paper, through theoretical and experimental studies in laboratory and field such as prototype tests, pullout tests, we evaluate the stability and behavior characteristics of the FRP soil nailing system. And, numerical analyses using FLAC2D were performed with respect to various soil conditions, where prototype test for excavation wall and pullout tests were carried out. As a result of this study, the FRP soil nailing systems show similar behavior characteristics with those of removable soil nailing system. Finally, considering the serviceability and mechanical stability of FRP soil nailing systems, it is enough to be used as a good alternative of general soil nailing system.

The Application of Impulse Oscillometry(IOS) in the Detection of Smoking Induced Early Airway Obstruction (Impulse Oscillometry(IOS)를 이용한 흡연자에서의 조기 기도폐쇄의 연구)

  • Kim, Youn-Seup;Kweon, Suk-Hoe;Song, Mi-Young;Yoo, Sun-Mi;Park, Jae-Seuk;Jee, Young-Koo;Lee, Kye-Young;Kim, Keun-Youl
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1030-1039
    • /
    • 1997
  • Background : Impulse Oscillometry is a noninvasive and effort-independent test used to characterize the mechanical impedance of the respiratory system. The clinical potential of the IOS is rapid and demands only passive cooperation which makes it especially appealing for children, for epidemiologic surveys and for conditions in which quiet breathig instead of forced expiratory maneuvers are preferred. However, several studies have shown conflicting results that the role of IOS about detection of smoking induced small airway diseases or early airway obstruction Methods : Study was to evaluate the clinical ability of the IOS to detect about smoking induced early airway obstruction in persons with normal spirometry test. Respiratory asymptomatic study groups were formed that one is non-smoking group, another is smoking group. Results : The parameters of spirometry were not significantly differences between non-smoking group and smoking group. Among the parameters of IOS, total resistance(non-smoking group : smoking group=$2.22{\pm}1.20$ : $2.58{\pm}1.71$), peripheral resistance($1.25{\pm}0.62$ : $1.47{\pm}0.10$), bronchial compliance($0.44{\pm}0.12$ : $0.47{\pm}0.16$) were not statistically significant different (p<0.05), but central resistance and lung compliance were not statistically significant different (unit ; resistance=hPa/l/s, compliance=l/hPa). Resistance(Rrs) was not statistically significant different with changes of frequences(5, 10, 15, 20, 25, 30, 35Hz), but Reactance(Xrs) was statistically significant different with low frequences that X5(non-smoking group : smoking group=$-0.62{\pm}0.28$ : $-0.76{\pm}0.48$, p<0.001) and X10($-0.06{\pm}0.19$ : $-0.15{\pm}0.33$, p<0.013) (unit; hPall/s, $hPa{\cong}cmH_2O$). Conclusion : Impulse oocillometer(IOS) is clinically available method to detect about smoking induced early airway obstruction. And clinically potential parameters of IOS were considers that total resistance, peripheral resistance, bronchial resistance, and reactance of low frequency at 5Hz, 10Hz.

  • PDF

Nondestructive Evaluation and Microfailure Mechanisms of Single Fibers/Brittle Cement Matrix Composites using Electro-Micromechanical Technique and Acoustic Emission (Electro-Micromechanical 시험법과 Acoustic Emission을 이용한 단섬유/시멘트 복합재료의 미세파괴 메커니즘과 비파괴적 평가)

  • 박종만;이상일;김진원;윤동진
    • Composites Research
    • /
    • v.14 no.3
    • /
    • pp.18-31
    • /
    • 2001
  • Interfacial and microfailure properties of the modified steel, carbon and glass fibers/cement composites were investigated using electro-pullout test under tensile and compressive tests with acoustic emission (AE). The hand-sanded steel composite exhibited higher interfacial shear strength (IFSS) than the untreated and even neoalkoxy zirconate (Zr) treated steel fiber composites. This might be due to the enhanced mechanical interlocking, compared to possible hydrogen or covalent bonds. During curing process, the contact resistivity decreased rapidly at the initial stage and then showed a level-off. Comparing to the untreated case, the contact resistivity of either Zr-treated or hand-sanded steel fiber composites increased to the infinity at latter stage. The number of AE signals of hand-sanded steel fiber composite was much more than those of the untreated and Zr-treated cases due to many interlayer failure signals. AE waveforms for pullout and frictional signals of the hand-sanded composite are larger than those of the untreated case. For dual matrix composite (DMC), AE energy and waveform under compressive loading were much higher and larger than those under tensile loading, due to brittle but well-enduring ceramic nature against compressive stress. Vertical multicrack exhibits fur glass fiber composite under tensile test, whereas buckling failure appeared under compressive loading. Electro-micromechanical technique with AE can be used as an efficient nondestructive (NDT) method to evaluate the interfacial and microfailure mechanisms for conductive fibers/brittle and nontransparent cement composites.

  • PDF

The Verification of Computer Simulation of Nitinol Wire Stent Using Finite Element Analysis (유한요소법을 이용한 나이티놀 와이어 스텐트의 전산모사 실험 데이터 검증)

  • Kim, Jin-Young;Jung, Won-Gyun;Jeon, Dong-Min;Shin, Il-Gyun;Kim, Han-Ki;Shin, Dong-Oh;Kim, Sang-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.139-144
    • /
    • 2009
  • Recently, the mathematical analysis of stent simulation has been improved, with the help of development of various tool which measure mechanical property and location of stent in artery. The most crucial part of the stent modeling is how to design ideal stent and to evaluate the interaction between stent and artery. While there has been great deal of researches on the evaluation of the expansion, stress distribution, deformation of the stent in terms of the various parameters, few verification through computer simulation has been performed about deformation and stress distribution of the stent. In this study, we have produced the corresponding results between experimental test using Universal Testing Machine and computer simulation for the ideal model of stent. Also, we have analyzed and compared stress distribution of stent in the cases of that with membrane and that without membrane. The results of this study would provide minimum change of plan and good quality for ideal stent replacing damaged artery through the analysis using computer simulation in the early stage of stent design.

  • PDF

Studies on the Mechanical Properties of Weathered Granitic Soil -On the Elements of Shear Strength and Hardness- (화강암질풍화토(花崗岩質風化土)의 역학적(力學的) 성질(性質)에 관(關)한 연구(硏究) -전단강도(剪斷强度)의 영향요소(影響要素)와 견밀도(堅密度)에 대(對)하여-)

  • Cho, Hi Doo
    • Journal of Korean Society of Forest Science
    • /
    • v.66 no.1
    • /
    • pp.16-36
    • /
    • 1984
  • It is very important in forestry to study the shear strength of weathered granitic soil, because the soil covers 66% of our country, and because the majority of land slides have been occured in the soil. In general, the causes of land slide can be classified both the external and internal factors. The external factors are known as vegetations, geography and climate, but internal factors are known as engineering properties originated from parent rocks and weathering. Soil engineering properties are controlled by the skeleton structure, texture, consistency, cohesion, permeability, water content, mineral components, porosity and density etc. of soils. And the effects of these internal factors on sliding down summarize as resistance, shear strength, against silding of soil mass. Shear strength basically depends upon effective stress, kinds of soils, density (void ratio), water content, the structure and arrangement of soil particles, among the properties. But these elements of shear strength work not all alone, but together. The purpose of this thesis is to clarify the characteristics of shear strength and the related elements, such as water content ($w_o$), void ratio($e_o$), dry density (${\gamma}_d$) and specific gravity ($G_s$), and the interrelationship among related elements in order to decide the dominant element chiefly influencing on shear strength in natural/undisturbed state of weathered granitic soil, in addition to the characteristics of soil hardness of weathered granitic soil and root distribution of Pinus rigida Mill and Pinus rigida ${\times}$ taeda planted in erosion-controlled lands. For the characteristics of shear strength of weathered granitic soil and the related elements of shear strength, three sites were selected from Kwangju district. The outlines of sampling sites in the district were: average specific gravity, 2.63 ~ 2.79; average natural water content, 24.3 ~ 28.3%; average dry density, $1.31{\sim}1.43g/cm^3$, average void ratio, 0.93 ~ 1.001 ; cohesion, $ 0.2{\sim}0.75kg/cm^2$ ; angle of internal friction, $29^{\circ}{\sim}45^{\circ}$ ; soil texture, SL. The shear strength of the soil in different sites was measured by a direct shear apparatus (type B; shear box size, $62.5{\times}20mm$; ${\sigma}$, $1.434kg/cm^2$; speed, 1/100mm/min.). For the related element analyses, water content was moderated through a series of drainage experiments with 4 levels of drainage period, specific gravity was measured by KS F 308, analysis of particle size distribution, by KS F 2302 and soil samples were dried at $110{\pm}5^{\circ}C$ for more than 12 hours in dry oven. Soil hardness represents physical properties, such as particle size distribution, porosity, bulk density and water content of soil, and test of the hardness by soil hardness tester is the simplest approach and totally indicative method to grasp the mechanical properties of soil. It is important to understand the mechanical properties of soil as well as the chemical in order to realize the fundamental phenomena in the growth and the distribution of tree roots. The writer intended to study the correlation between the soil hardness and the distribution of tree roots of Pinus rigida Mill. planted in 1966 and Pinus rigida ${\times}$ taeda in 199 to 1960 in the denuded forest lands with and after several erosion control works. The soil texture of the sites investigated was SL originated from weathered granitic soil. The former is situated at Py$\ddot{o}$ngchangri, Ky$\ddot{o}$m-my$\ddot{o}$n, Kogs$\ddot{o}$ng-gun, Ch$\ddot{o}$llanam-do (3.63 ha; slope, $17^{\circ}{\sim}41^{\circ}$ soil depth, thin or medium; humidity, dry or optimum; height, 5.66/3.73 ~ 7.63 m; D.B.H., 9.7/8.00 ~ 12.00 cm) and the Latter at changun-long Kwangju-shi (3.50 ha; slope, $12^{\circ}{\sim}23^{\circ}$; soil depth, thin; humidity, dry; height, 10.47/7.3 ~ 12.79 m; D.B.H., 16.94/14.3 ~ 19.4 cm).The sampling areas were 24quadrats ($10m{\times}10m$) in the former area and 12 in the latter expanding from summit to foot. Each sampling trees for hardness test and investigation of root distribution were selected by purposive selection and soil profiles of these trees were made at the downward distance of 50 cm from the trees, at each quadrat. Soil layers of the profile were separated by the distance of 10 cm from the surface (layer I, II, ... ...). Soil hardness was measured with Yamanaka soil hardness tester and indicated as indicated soil hardness at the different soil layers. The distribution of tree root number per unit area in different soil depth was investigated, and the relationship between the soil hardness and the number of tree roots was discussed. The results obtained from the experiments are summarized as follows. 1. Analyses of simple relationship between shear strength and elements of shear strength, water content ($w_o$), void ratio ($e_o$), dry density (${\gamma}_d$) and specific gravity ($G_s$). 1) Negative correlation coefficients were recognized between shear strength and water content. and shear strength and void ratio. 2) Positive correlation coefficients were recognized between shear strength and dry density. 3) The correlation coefficients between shear strength and specific gravity were not significant. 2. Analyses of partial and multiple correlation coefficients between shear strength and the related elements: 1) From the analyses of the partial correlation coefficients among water content ($x_1$), void ratio ($x_2$), and dry density ($x_3$), the direct effect of the water content on shear strength was the highest, and effect on shear strength was in order of void ratio and dry density. Similar trend was recognized from the results of multiple correlation coefficient analyses. 2) Multiple linear regression equations derived from two independent variables, water content ($x_1$ and dry density ($x_2$) were found to be ineffective in estimating shear strength ($\hat{Y}$). However, the simple linear regression equations with an independent variable, water content (x) were highly efficient to estimate shear strength ($\hat{Y}$) with relatively high fitness. 3. A relationship between soil hardness and the distribution of root number: 1) The soil hardness increased proportionally to the soil depth. Negative correlation coefficients were recognized between indicated soil hardness and the number of tree roots in both plantations. 2) The majority of tree roots of Pinus rigida Mill and Pinus rigida ${\times}$ taeda planted in erosion-controlled lands distributed at 20 cm deep from the surface. 3) Simple linear regression equations were derived from indicated hardness (x) and the number of tree roots (Y) to estimate root numbers in both plantations.

  • PDF

Evaluation of Image Qualities for a Digital X-ray Imaging System Based on Gd$_2$O$_2$S(Tb) Scintillator and Photosensor Array by Using a Monte Carlo Imaging Simulation Code (몬테카를로 영상모의실험 코드를 이용한 Gd$_2$O$_2$S(Tb) 섬광체 및 광센서 어레이 기반 디지털 X-선 영상시스템의 화질평가)

  • Jung, Man-Hee;Jung, In-Bum;Park, Ju-Hee;Oh, Ji-Eun;Cho, Hyo-Sung;Han, Bong-Soo;Kim, Sin;Lee, Bong-Soo;Kim, Ho-Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.253-259
    • /
    • 2004
  • in this study, we developed a Monte Carlo imaging simulation code written by the visual C$\^$++/ programing language for design optimization of a digital X-ray imaging system. As a digital X-ray imaging system, we considered a Gd$_2$O$_2$S(Tb) scintillator and a photosensor array, and included a 2D parallel grid to simulate general test renditions. The interactions between X-ray beams and the system structure, the behavior of lights generated in the scintillator, and their collection in the photosensor array were simulated by using the Monte Carlo method. The scintillator thickness and the photosensor array pitch were assumed to 66$\mu\textrm{m}$ and 48$\mu\textrm{m}$, respertively, and the pixel format was set to 256 x 256. Using the code, we obtained X-ray images under various simulation conditions, and evaluated their image qualities through the calculations of SNR (signal-to-noise ratio), MTF (modulation transfer function), NPS (noise power spectrum), DQE (detective quantum efficiency). The image simulation code developed in this study can be applied effectively for a variety of digital X-ray imaging systems for their design optimization on various design parameters.

Antrum Formation and Growth of Mouse Pre-antral Follicles Cultured in Two Different Culture Media without Hormones

  • Kim, Ju-Hwan;Kim, Hwan-Tae;Park, Kee-Sang;Song, Hai-Bum;Chun, Sang-Sik
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.8-8
    • /
    • 2001
  • Mouse follicles require the addition of gonadotropins (Gns) to complete maturation and ovulation of oocyte and antrum formation of follicles in vitro. However, we tried examination of in vitro growth of mouse pre-antral follicles in medium without Gns and physiological factors. And also, pre-antral follicles were isolated from ovaries by mechanical method. Our present studies were conducted to evaluate on the growth of follicles and intra-follicular oocytes and antrum formation in vitro of mouse pre-antral follicles in two different media. Pre-antral follicles (91-120${\mu}{\textrm}{m}$) were isolated mechanically by fine 30G needles not using enzymes from ovary of 3-6 weeks old female ICR mice. Isolated pre-antral follicles were cultured in 20 ${mu}ell$ droplets of TCM (n=17; follicles: 107.8 $\pm$ 1.58 ${\mu}{\textrm}{m}$; oocytes: 59.9$\pm$1.2 ${\mu}{\textrm}{m}$) or MEM (n=12; follicles: 109.3$\pm$2.53 ${\mu}{\textrm}{m}$; oocytes: 55.4 $\pm$1.6${\mu}{\textrm}{m}$) under mineral oil on the 60mm culture dish. All experimental media was supplemented with 10% FBS but without Gns and/or physiological factors. Pre-antral follicles were individually cultured in drops for 8 days. Antrum formation and growth of pre-antral follicles and intra-follicular oocytes were evaluated using a precalibrated ocular micrometer at $\times$200 magnifications during in vitro culture. Results between different groups were analyzed using combination of Student's t-test and Chi-square, and considered statistically significant when P<0.05. Antrum formation of pre-antral follicles had started in two culture media on day-2. On day-8, antrum formation had occurred in 58.3%(7/12) of pre-antral follicles cultured in MEM, but only in 23.5% (4/17) of those cultured in TCM (P=0.0364). Growth of pre-antral follicles and intra-follicular oocytes were observed on day-4 and -8. On day-4, follicular diameters was similar (P=0.1338) in TCM (119.4$\pm$2.58 ${\mu}{\textrm}{m}$) and MEM (125.4$\pm$4.52 ${\mu}{\textrm}{m}$). However, on day-8, diameters of pre-antral follicles cultured in MEM (168.9$\pm$17.29 ${\mu}{\textrm}{m}$) was significantly (P=0.0248) bigger than that in TCM (126.7$\pm$4.28 ${\mu}{\textrm}{m}$). On day-4 and -8, diameters of intra-follicular oocytes were similar TCM (67.1$\pm$1.3 and 72.4$\pm$0.9${\mu}{\textrm}{m}$) and MEM (65.2$\pm$1.7 and 73.3$\pm$1.5 ${\mu}{\textrm}{m}$), respectively. We can conform that medium not supplemented with Gns and/or physiological factors can be used for in vitro antrum formation and growth of mouse pre-antral follicles and intra-follicular oocytes. In conclusion, MEM supplemented with FBS can be used for growth in vitro of mouse pre-antral follicles isolated mechanically.

  • PDF

Studies on the Packaging and Preservation of Kimchi (우리나라 김치의 포장과 저장방법에 관한 연구)

  • Lee, Yang-Hee;Yang, Ick-Whan
    • Applied Biological Chemistry
    • /
    • v.13 no.3
    • /
    • pp.207-218
    • /
    • 1970
  • Studies were carried out to develope the most economical and practical methods of packaging and preservation of kimchi, so commercialization of kimchi manufacture could proceed rapidly. The results obtained may be summarized as following. (1) It is generally established that the acceptable range of lactic acid content of kimchi is between 0.4% and 0.75%. Based on sensory evaluation, kimchi having lactic acid content below 0.4% and above 0.75% was not edible, and the time of optimum taste corresponded to the vicinity of 0.5% of lactic acid content. For the refrigeration storage with or without preservatives, the packaging kimchi in plastic film must be done at the lactic acid content of 0.45%, for lactic acid fermentation will continue slowly after the packaging. However, for the heat sterilized kimchi the packaging should be done at the 0.5% of lactic acid content for the best because lactic acid fermentation is completely stopped after the packaging. (2) Polyethylene, polypropylene, and polycello were chosen as suitable packaging materials. Polyethylene is cheapest among them but kimchi packaged in this film was damaged frequently in handling process and gave off kimchi flavor. On the other hand polypropylene also gave off kimchi flavor, but its higher mechanical strength gave better protection to kimchi and it had superior display effect due to the transparancy. Therefore polypropylene made much better packaging material. Polycello proved to be the best packaging material from the standpoint of physical characteristics but its price is higher than that of other plastic films. To be effective, the thickness of plastic films for packaging kimchi must exceed 0.08mm. (3) Keeping property of kimchi appeared to be excellent by means of freezing. However, by the time the frozen kimchi was thawed out at room temperature, moisture loss due to drip was extensive, rendering the kimchi too stringy. (4) Preservation of kimchi at refrigerated temperatures proved to be the best method and under the refrigerated condition the kimchi remained fresh as long as 3 months. The best results were obtained when kimchi was held at $0^{\circ}C$. (5) In general, preservatives alone were not too elective in preserving kimchi. Among them potassium sorbate appeared to be most effective with the four fold extension of self-life at $20^{\circ}C$ and two fold extension at $30^{\circ}C$. (6) In heat sterilization the thickness of packaged kimchi product had a geat effect upon the rate of heat penetration. When the thickness ranged from 1.5 to 1.8cm, the kimchi in such package could be sterilized at $65^{\circ}C$ for 20 minutes. Kimchi so heat treated could be kept at room temperature as long as one month without apparent changes in quality. (7) Among combination methods, preservation at refrigerated and heat sterilization could be favorably combined. When kimchi was stored at $4^{\circ}C$ after being sterilized at $65^{\circ}C$ for 20 minutes, it was possible to preserve the kimchi for more than 4 months.

  • PDF

Clinical Analysis of 500 Cases of Coronary Artery Bypass Grafting (관상동맥 우회술 500례의 임상적 고찰)

  • Shin, Yoon-Cheol;Kim, Ki-Bong;Ahn, Hyuk;Chae, Hurn;Rho, Joon-Ryang;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.525-531
    • /
    • 1999
  • Background: We analyzed five hundred patients who underwent either isolated or concomitant coronary artery bypass grafting(CABG) between November 1981 and June 1997. Material and Method: There were 330 males and 170 females with a mean age of 57.4$\pm$8.9 years. To evaluate the preoperative status, we performed electrocardiograghy, echocardiography, MIBI scan, Duplex sonogram, common blood test including CK and LDH and coronary angiography. Result: Preoperative clinical diagnoses were unstable angina in 282 (56.4%), stable angina in 141 (28.2%), postinfarction angina in 58 (11.6%), acute myocardial infarction in 8 (1.6%), variant angina in 7 (1.4%) and failed percutaneous transluminal coronary angioplasty in 4 (0.8%) patients. Preoperative angiographic diagnoses were three-vessel disease in 263 (52.6%), two-vessel disease in 93 (18.6%), one-vessel disease in 71 (14.2%), left main disease in 68 (13.6%), and others in 5 (1.0%) patients. Patients had various risk factors for coronary disease, and the frequency of the risk factors such as hypertension, diabetes and smoking showed increasing tendency year by year. We used saphenous vein grafts in 1143, internal thoracic artery grafts in 442, radial artery graft in 17, and gastroepiploic artery graft in 1 anastomosis. The mean number of grafts was 3.2$\pm$1.2 per patient. Concomitant operations were prosthetic valve replacement or valvuloplasty in 31, coronary endarterectomy and angioplasty in 27, left main coronary angioplasty in 13, carotid endarterectomy in 5, and neurologic problems, bleeding, and perioperative myocardial infarction. The mean follow-up period was 25$\pm$23 months and there were 5 cases of reoperation. Conclusion: We hope that the surgical results would improve with the accumulation of experience, application of new myocardial protection technique, and timely intervention of mechanical assisted devices.

  • PDF

Biaxial Strain Analysis of Various Fixation Models in Porcine Aortic and Pulmonary Valves (돼지 대동맥 판막과 폐동맥 판막의 고정 방법에 따른 양방향 압력-신장도의 비교분석)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Choi, Seung-Hwa
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.566-575
    • /
    • 2009
  • Background: The function of a bioprosthetic heart valve is determined largely by the material properties of the valve cusps. The uniaxial tensile test has been studied extensively. This type of testing, however, does not replicate the natural biaxial loading condition. The objective of the present study was to investigate the regional variability of the biaxial strain versus pressure relationship based on the types of fixation liquid models. Material and Method: Porcine aortic valves and pulmonary valves were assigned to three groups: the untreated fresh group, the fixed with glutaraldehyde (GA) group, and the glutaraldehyde with solvent (e.g., ethanol) group. For each group we measured the radial and circumferential stretch characteristics of the valve as a function of pressure change. Result: Radial direction elasticity of porcine aortic and pulmonary valves were better than circumferential direction elasticity in fresh, GA fixed and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of pulmonary valves were better than aortic valves in GA fixed, and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of aortic valves were decreased after GA and GA+solvent fixation(p=0.00), except for circumferential elasticity of GA+solvent fixed valves (p=0.785). The radial (p=0.137) and circumferential (p=0.785) direction of elasticity of aortic valves were not significantly different between GA fixed. and GA+solvent fixed groups. Radial (p=0.910) and circumferential (p=0.718) direction of elasticity of pulmonary valve also showed no significant difference between GA fixed and GA+solvent fixed groups. Conclusion: When fixing porcine valves with GA, adding a solvent does not cause a loss of mechanical properties, but, does not improve elasticity either. Radial direction elasticity of porcine aortic and pulmonary valves was better than circumferential direction elasticity.