• Title/Summary/Keyword: Mechanical recovery performance

Search Result 255, Processing Time 0.023 seconds

The performance of a heat pump with 3-piping system at various charging conditions (3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구)

  • Song, In-Sik;Choi, Jong-Min;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF

A Study on The Performance of a Heat Recovery Ventilator According to the Properties of Spacers (스페이서의 재질변화에 따른 전열교환기 성능변화에 관한 연구)

  • Lim, Tae-Kun;Jeon, Byung-Heon;Kim, Jong-Won;Jung, Sung-Hak;Lee, Seung-Kap;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.224-229
    • /
    • 2012
  • The importance of ventilation system is being emphasized by interest of indoor air quality. Especially, heat recovery ventilation system has attracted attention as most effective ventilation plan. Because it can reduce hazardous construction materials, indoor air pollutions, and also can reduce air conditioning energy cost. In heat recovery ventilator, the element core is the most important part. The element core is composed of liner and spacer. And liner and spacer are stacked alternately. On the Liner, heat and humidity transfer are made between supply and exhaust air. And spacer plays a role as a tunnel of exhaust and supply. In this study, we investigated and analyzed the efficiency of a heat recovery ventilator, when the spacer's properties are changed. As a result, difference spacer's properties affect an efficiency of heat recovery ventilator.

Light Source Target Detection Algorithm for Vision-based UAV Recovery

  • Won, Dae-Yeon;Tahk, Min-Jea;Roh, Eun-Jung;Shin, Sung-Sik
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.9 no.2
    • /
    • pp.114-120
    • /
    • 2008
  • In the vision-based recovery phase, a terminal guidance for the blended-wing UAV requires visual information of high accuracy. This paper presents the light source target design and detection algorithm for vision-based UAV recovery. We propose a recovery target design with red and green LEDs. This frame provides the relative position between the target and the UAV. The target detection algorithm includes HSV-based segmentation, morphology, and blob processing. These techniques are employed to give efficient detection results in day and night net recovery operations. The performance of the proposed target design and detection algorithm are evaluated through ground-based experiments.

Compliant Mechanism Topology Optimization of Metal O-Ring (금속오링씰의 컴플라이언트 메커니즘 위상최적설계)

  • Kim, Geun-Hong;Lee, Young-Shin;Yang, Hyung-Lyeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.4
    • /
    • pp.537-545
    • /
    • 2013
  • The elastic recovery of a metal seal is a factor that can be used to assess its sealing performance. In this study, a compliant mechanism topology optimization has been performed to find a structure of a metal O-ring seal that can maintain excellent sealing performance with a maximized elastic recovery over extended operation. An evolutionary structural optimization (ESO) was used as a topology optimization algorithm with two different types of objective functions considering both flexibility and stiffness. In particular, a circular design domain was adopted to consider the outer shape of the metal O-ring seal. The elastic recovery of the optimal topology was calculated and compared to that of a commercial product.

Performance Improvement of Cured-In-Place-Pipe(CIPP) Process by Boiler Waste Heat Recovery (보일러 폐열 회수를 통한 현장경화관(CIPP)공정 성능 향상)

  • Kim, Young-Jin;Jung, Chung Woo;Lee, Yoon Jung;Kim, Sung Soo;Kang, Yong Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.164-167
    • /
    • 2013
  • The objectives of this paper are to study the performance improvement of waste heat recovery from a boiler, by the Cured-In-Place-Pipe(CIPP) process. The conventional apparatus does not utilize the waste heat from the boiler during the process. However, the present apparatus recovers the waste heat from the boiler. When the new apparatus is used, the bending strength and modulus of the CIPP becomes double, and is over 45% stronger, than the required conditions, respectively. It is found that the energy consumption reduces to 50%, by recovering the waste heat from the boiler, and the oil consumption amount reduces to 1/3, compared to the conventional apparatus.

A Study on the Dew Condensation According to the Operational Conditions of a Heat-Recovery Ventilator (전열교환 환기시스템의 운전 상태에 따른 결로 발생에 관한 연구)

  • Jeon, Byung-Heon;Kim, Jong-Won;Lee, Seung-Kap;Lee, Young-Ju;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.10
    • /
    • pp.529-533
    • /
    • 2013
  • Heat-recovery ventilators are being adopted in most newly built apartment houses for energy reduction and indoor environment improvement. In winter, however, the dew condensation resulting from the difference between the indoor and outdoor temperatures may reduce the ventilator's performance and threaten the health of indoor residents. This study analyzes the occurrence of dew condensation according to the ventilator's operational conditions and the changes of temperature and products. The experimental results show that condensations is formed at $26^{\circ}C$ and 60%R.H, which is an unfavorable climatic condition, and when the damper is not closed tightly. Therefore it is important to ensure damper performance to prevent back flow.

Analysis of Design and Part Load Performance for gas Turbine Cogeneration Systems (가스터빈 열병합발전 시스템의 설계점 설정 및 부분부하 성능해석)

  • 김동섭;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2167-2176
    • /
    • 1994
  • This paper presents some useful design criteria for the turbine cogeneration system through both the design and off-design analysis. Comparative analysis of the part load performance is carried out for several gas turbines which have different design parameters represented by the turbine inlet temperature and pressure ratio. It is shown that the variation in part load efficiency considerably depends on the design parameter. The off-design operation of the heat recovery steam generator is simulated by introducing adequate assumptions for the heat transfer process. It is turned out that the design parameters of heat recovery steam generator should be determined by considering the favorable operation at the off-design conditions.

Performance Evaluation and Numerical Calculation of Flows through a Vaned Diffuser for Centrifugal Compressor (원심압축기용 베인 디퓨저 내부유동의 수치해석 및 성능평가)

  • Choi, Yun-Ho;Kang, Shin-Hyoung;Lee, Jang-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1296-1309
    • /
    • 1999
  • A three dimensional compressible Navier-Stokes code is developed to analyze flowfields and performance of a vaned diffuser in a centrifugal compressor. It employs scalar implicit approximate factorization, finite volume formulation, second order upwind differencing and a two-equation $q-{\omega}$ turbulence model based on the integration to the wall. Pressure recovery and loss coefficients of a vaned diffuser are evaluated using a developed computer code. The simulated three dimensional flows show how through flow structure affects pressure recovery performance and loss coefficients of a vane for design and off-design inlet flow angles. Development of complex three dimensional flow over the inlet region and leading edge are very influential to the overall flow and performance.

Performance Characteristics and Efficiencies of Micro-Hydro Pelton Turbine with Nozzle Diameter Variation (노즐 구경에 따른 초소수력 펠턴 터빈의 효율 및 성능 특성)

  • Jo, In Chan;Park, Joo Hoon;Shin, Youhwan;Kim, Kwang Ho;Chung, Jin Taek;Kim, Dong Ik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.3
    • /
    • pp.60-65
    • /
    • 2015
  • This paper deals with performance characteristics and efficiencies of Pelton turbine can be applied as one of ERDs (Energy Recovery Devices) of PRO (Pressure Retarded Osmosis) system for desalination. The objective of this study is experimentally estimating the performance of micro-scale Pelton turbine for PRO pilot plant. Especially the performance characteristics with variations of jet nozzle diameter of Pelton turbine are discussed in detail. In order to do this, lab scale test rig of Pelton turbine was made for performance test, which includes water tank, Pelton wheel with buckets, jet nozzle and torque brake and so on. The parameter effects related on Pelton turbine's efficiency were investigated and discussed on the influence of the variations of load and speed ratio.

Effects of Warm-up Performance on SI Engine with Exhaust Heat Recovery System (배기열 회수장치 적용에 따른 SI 엔진의 웜업 성능에 미치는 영향)

  • Park, Kyoun-Suk;Suh, Ho-Cheol;Park, Sun-Hong;Kim, In-Tae;Jang, Sung-Wook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.53-60
    • /
    • 2011
  • The effect of exhaust heat recovery system can be evaluated by two well known method. First method is to measure the time duration from engine start under cold coolant temperature till coolant get warmed. By this methodology coolant warming duration can be index of warm-up effect. Second method is to analyze heat balance of the engine during warm-up phase under steady engine operation so that wasted energy by losses such as cooling and exhaust can be index of warm-up effect. This study focused on evaluation of warming-up effect by both methodology above mentioned using 2L SI engine under from idle to 2000rpm steady condition. Results, idle operation showed low heat recovery efficiency but under higher engine speed condition, remarkable heat recovery efficiency improvement was observed. In 2000rpm steady condition, warm-up duration of engine is decreased by exhaust heat recovery system.