• Title/Summary/Keyword: Mechanical Test

Search Result 11,494, Processing Time 0.047 seconds

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

Three point bending test of recycled Nickel-Titanium alloy wires (재생한 니켈 티타늄 호선의 3점 굴곡물성실험)

  • Lee, Sung-Ho;Chang, Young Il
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.731-738
    • /
    • 2000
  • The purpose of this study was to investigate the change of 3 point bending properties of various nickel titanium wires after recycling. Four Types of nickel-titanium (Align: martensitic type, NiTi, Optimalloy, Sentalloy: austenitic type) wires were divided to three groups: as-received condition (T0: control group), treated in artificial saliva for four weeks (T1) and autoclaved after being treated in artificial saliva (T2). Detrimental changes were observed for the selected mechanical properties in three point bending test. Loading force at 3mm deflection, unloading force at 3mm deflection, stress hysteresis, loading force at 1mm deflection, unloading force at 1mm deflection and stress hysteresis at 1mm deflection were calculated. The findings suggest that : 1. Align demonstrated statistically significant increase In loading force (p<0.05) and unloading force (p<0.01) at 3mm deflection after recycling(T2), but NiTi, Optimalloy and Sentalloy showed no statistically difference after recycling. 2. Align demonstrated statistically significant decrease in hysteresis(p<0.01) after recycling(T2) but NiTi, Optimalloy and Sentalloy showed no statistically significant difference after recycling. 3. All wires showed no statistically significant difference in loading force at 1mm deflection after recycling(T2). 4. Align demonstrated statistically significant decrease in unloading force in 1mm deflection (p<0.05) after recycling(T2) but NiTi, Optimalloy and Sentalloy showed no statistically difference after recycling 5. Loading force and unloading force of T1 showed no significant change compared with those of T0, but loading force and unloading force of T2 showed significant changes compared with those of T0(p<0.05, p<0.01 respectively). 6. Align demonstrated a tendency to lose some of this pseudoelasticity in T1 and pseudoplasticity and pseudoelasticity in T2.

  • PDF

Fundamental Studies on the Development of Axial-Flow Combine(I) -Evaluation of the Design Parameters of Grain-Straw Separator- (축류(軸流) 콤바인의 개발(開發)에 관(關)한 기초(基礎) 연구(硏究)(I) -조선별장치(粗選別裝置)의 설계변수(設計變數)의 평가(評價)-)

  • Lee, S.K.;Kim, S.T.;Choi, K.H.
    • Journal of Biosystems Engineering
    • /
    • v.11 no.2
    • /
    • pp.31-40
    • /
    • 1986
  • Cylindrical and conical types of grain-straw separation equipment which has a stationary crimped sieve drum with rotating inner rotor were constructed. The developed equipments were tested to investigate the characteristics of separating performance under various mechanical conditions and crop conditions. As increase of the inclination of equipment and decrease of pitch of cover vane, the grain recovery was increased while straw rejection was decreased. The grain recovery and overall efficiency were decreased as the rotor speed and feeding velocity were increased for both varieties of rice, moisture contents, and test equipments. Conical prototype equipment performed higher straw rejection, lower grain recovery, and lower power requirement. However, separation performance of conical type equipment was more widely varied with various test conditions compared to cylindrical one. The performance of both equipments showed relatively insensitive to crop feedrate and crop properties, such as variety, moisture content, and grain-to-straw ratio.

  • PDF

A Study on the Lime Stabilization of Livestock Waste (축산폐기물의 안정화 처리에 대한 연구)

  • Kim, Hyun-Chul;Choi, Yong-Su
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.91-99
    • /
    • 1995
  • One of alternative conventional technologies used for treatment of livestock wastes is composting process, and recently some mechanical composting processes are being practiced. It is, however, recognized the composting process also has its own limitations such as longer time requirement, and difficulties to estimate the degree of decomposition, etc. The incomplete compost contains potentially harmful materials to crops and public health due to instabilized organic contents and pathogenic organisms. The purpose of this investigation is to develop an innovative system whereby anxious livestock wastes are thoroughly stabilized and disinfected. Thus the overall management scheme should meet the following requirements. 1. A system should be in a cost-effective and environmentally sound manner. 2. Sludges must be chemically stabilized and bacteriologically safe. 3. Odor-free by product should be applied to crop land. 4. Sludges are sources of fertilizer nutrients and/or soil amendments to enhance crop production. 5. And they can be used as potential pH adjusting agent of the acidified soils. Overall effectiveness of the developed system is experimentally tested to satisfy the preset criteria and requirements. Major experiments are divided into four categories: they are 1. chemical stability test, 2. optimal condition test of stabilization process, 3. bacteriological examination and disinfection tests, and 4. deodorization tests The stabilization process is consisted of the stabilizing reaction process and the drying process. Stabilized wastes is dried by both sun dryer and rotary dryer. It is shown that an additive dosage of about g/kg solid in wastes with a minimum of 5-minutes reaction would be necessary for effective stabilization reaction. The stabilization process is consisted of the stabilizing reaction process and drying process. Stabilized wastes are dried by both sun dryer and rotary dryer. It is shown that an additive dosage of about 300g/kg solid in wastes with a minimum of 5-minutes reaction would be necessary for effective stabilization reaction. In the stabilization reaction process, the pH of wastes is lowered from initial values of 12.3 to 8.6. High pH prevents odor production and kills pathogenic organisms. Organic matter contents in the stabilized wastes are about 50% and the sum of contents of fertilizer elements such as total nitrogen, $P_2O_5$ and $K_2O$ are about 5.3%. The livestock wastes that are stabilized chemically and hygienically can be used as a good soil conditioner and/or organic fertilizer.

  • PDF

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF

Improvement of Rotary Tine for Barley Seeder Attached to Rotary Tiller (로우터리 맥류파종기 경운날의 개량시험)

  • 김성래;김문규;김기대;허윤근
    • Journal of Biosystems Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-23
    • /
    • 1979
  • The use of barley seeder attached to rotary tiller in the rural area has a significant meaning not only for the solution of labor peak season, but also for the increase of land utilization efficiency. The facts that presently being used barley seeders are all based on the mechanical principles of the reverse rotation, center drive and are all using forward rotating tine, which is used to be easily and heavily worn out when it rotates reversely, raise problem of recommending them to rural area in Korea. Therefore, the main objective of the study was to develop new type of rotary tine attachable to barley seeders. To attain the objective the following approaches were applied. (1) The kinematic analysis of reverse rotating barley seeders. (2) The studies on the soil bin and artificial soil. (3) The comparative experiment on the power requirement of prototype tine. The results obtained from the studies are summarized as follow: 1. The kinematic analysis of barley seeder attached to rotary tiller: The following results were obtained from the kinematic analysis for deriving general formulae of the motion and velocity characterizing the rotary tine of barley seeders presently being used by farmers. a) The position vector (P) of edge point (P) in the rotary tine of reverse rotating, center drive was obtained by the following formula. $$P=(vt+Rcos wt)i+Rsin wt j+ \{ Rcos \theta r sin \alpha cos (wt- \beta +\theta r) +Rsin \theta r sin \alpha sin (wt-\beta + \theta r) \} lk $$ b) The velocity of edge point $(P^')$ of reverse rotating, center drive rotary tine was obtained by the following formula. $$(P^')=(V-wR sin wt)i+(w\cdot Rcoswt)j + \{ -w\cdot Rcos \theta r\cdot sin \alpha \cdot sin (wt-\beta +\theta r) + w\cdot Rsin \theta r\cdot sin \alpha \cdot cos (wt- \beta + \theta r \} k $$ c) In order to reduce the power requirement of rotary tine, the angle between holder and edge point was desired to be reduced. d) In order to reduce the power requirement, the edge point of rotary tine should be moved from the angle at the begining of cutting to center line of machine, and the additional cutting width should be also reduced. 2. The studies on the soil bin and artificial soil: In order to measure the power requirement of various cutting tines under the same physical condition of soil, the indoor experiments Viere conducted by filling soil bin with artificially made soil similar to the common paddy soil and the results were as follows: a) When the rolling frequencies$(x)$ of the artificial soil were increased, the densIty$(Y)$ was also increased as follows: $$y=1.073200 +0.070780x - 0.002263x^2 (g/cm^3)$$ b) The absolute hardness $(Y)$ of soil had following relationship with the rolling frequencies$(x)$ and were increased as the rolling frequencies were increased. $$Y=37.74 - \frac {0.64 + 0.17x-0. 0054x^2} {(3.36-0.17x + 0.0054x^2)^3} (kg/cm^3)$$ c) The density of soil had significant effect on the cohesion and angle of internal friction of soil. For instance, the soil with density of 1.6 to 1.75 had equivalent density of sandy loam soil with 29.5% of natural soil moisture content. d) The coefficient of kinetiic friction of iron plate on artificial soil was 0.31 to 0.41 and was comparable with that of the natural soil. e) When the pulling speed of soil bin was the 2nd forward speed of power tiller, the rpm of driving shaft of rotary was similar to that of power tiller, soil bin apparatus is indicating the good indoor tester. 3. The comparative experiment on the power requirement of prototype tine of reverse rotating rotary: According to the preliminary test of rotary tine developed with various degrees of angle between holder and edge pcint due to the kinematic analysis, comparative test between prototype rotary tine with $30 ^\circ $ and $10 ^\circ$ of it and presently being used rotary tine was carried out 2nd the results were as follows: a) The total cutting torque was low when the angle between holder and edge point was reduced. b) $\theta r$ (angle between holder and edge point) of rotary tine seemed to be one: of the factors maximizing the increase of torque. c) As the angle between holder and edge point ($\theta r$) of rotary tine was $30 ^\circ $ rather than $45 ^\circ $, the angle of rotation during cutting soil was reduced and the total cutting torque was accordingly reduced about 10%, and the reduction efficiency of total cutting torque was low when the angle between holder and edge point ($\theta r$) of rotary tine was $10 ^\circ $, which indicates that the proper angle between holder and edge point of rotary tine should be larger than $10 ^\circ $ and smaller than $30 ^\circ $ . From above results, it could be concluded that the use of the prototype rotary tine which reduced the angle between holder and edge point to $30 ^\circ $, insted of $45 ^\circ $, is disirable not only decreasing the power requirements, but also increasing the durabie hour of it. Also forward researches are needed, WIlich determine the optimum tilted angle of rotary brocket, and rearrangement of the rotary tine on the rotary boss.

  • PDF

The Effect of Temperature and Concentration of Setting Solution on the Rheological Properties of Injectable Calcium Phosphate (경화액의 농도와 온도가 인산칼슘시멘트의 유변학적 성질에 미치는 영향에 관한 연구)

  • Yoo, Hyun-Mi;Chang, Seok-Woo;Park, Dong-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.73-82
    • /
    • 2009
  • Injectable calcium phosphate cement (CPC) has been used as bone substitute successfully due to good biocompatibility and osteoconductivity. One of the important mechanical characteristics of CPC is flowablility, which can be evaluated by measuring rheological parameters. However, there have been few studies that measured rheological properties of CPC. The purpose of this study was to evaluate the effects of temperature and concentrations of 2 kinds of setting solutions, hydroxyprophyl methylcellulose (HPMC) and polyacrylic acid (PAA), on rheological properties of CPC. The CPC used was dicalcium phosphate dihydrate (DCPD). Rheological properties of CPC paste were measured using rheometer. The effect of concentrations of each solution (2% and 1% HPMC and 35% and 17.5% PAA) was evaluated. The effect of temperature ($25^{\circ}C$ and $37^{\circ}C$) on the rheological properties of CPC was also investigated. The statistical analysis was carried out with Mann-whitney test with Bonferronis collection. CPC with both setting solutions showed shear thinning behavior. Higher concentrations of setting solution (2% HPMC and 35% PAA) produced significantly higher viscosity than lower concentrations of setting solution (1% HPMC and 17.5% PAA). CPC with HPMC showed significantly higher viscosity at $37^{\circ}C$ that at $25^{\circ}C$. CPC with PAA showed lower viscosity at $37^{\circ}C$ than at $25^{\circ}C$, although the difference was not statistically significant. The results showed that CPC with HPMC or PAA solutions are pseudoplastic and the concentrations of setting solutions and temperature may have an effect on the rheological properties of CPC paste. These results showed that the flowability of injectable CPC could be improved by use of increasing frequency of oscillation. In clinical practice, the use of ultrasonic vibration would be helpful in application of injectable CPC. CPC with HPMC could be more easily applicated at $25^{\circ}C$ than $37^{\circ}C$. The use of lower concentrations of HPMC and PAA solution would be beneficial in terms of flowability.

Financial Fraud Detection using Text Mining Analysis against Municipal Cybercriminality (지자체 사이버 공간 안전을 위한 금융사기 탐지 텍스트 마이닝 방법)

  • Choi, Sukjae;Lee, Jungwon;Kwon, Ohbyung
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.3
    • /
    • pp.119-138
    • /
    • 2017
  • Recently, SNS has become an important channel for marketing as well as personal communication. However, cybercrime has also evolved with the development of information and communication technology, and illegal advertising is distributed to SNS in large quantity. As a result, personal information is lost and even monetary damages occur more frequently. In this study, we propose a method to analyze which sentences and documents, which have been sent to the SNS, are related to financial fraud. First of all, as a conceptual framework, we developed a matrix of conceptual characteristics of cybercriminality on SNS and emergency management. We also suggested emergency management process which consists of Pre-Cybercriminality (e.g. risk identification) and Post-Cybercriminality steps. Among those we focused on risk identification in this paper. The main process consists of data collection, preprocessing and analysis. First, we selected two words 'daechul(loan)' and 'sachae(private loan)' as seed words and collected data with this word from SNS such as twitter. The collected data are given to the two researchers to decide whether they are related to the cybercriminality, particularly financial fraud, or not. Then we selected some of them as keywords if the vocabularies are related to the nominals and symbols. With the selected keywords, we searched and collected data from web materials such as twitter, news, blog, and more than 820,000 articles collected. The collected articles were refined through preprocessing and made into learning data. The preprocessing process is divided into performing morphological analysis step, removing stop words step, and selecting valid part-of-speech step. In the morphological analysis step, a complex sentence is transformed into some morpheme units to enable mechanical analysis. In the removing stop words step, non-lexical elements such as numbers, punctuation marks, and double spaces are removed from the text. In the step of selecting valid part-of-speech, only two kinds of nouns and symbols are considered. Since nouns could refer to things, the intent of message is expressed better than the other part-of-speech. Moreover, the more illegal the text is, the more frequently symbols are used. The selected data is given 'legal' or 'illegal'. To make the selected data as learning data through the preprocessing process, it is necessary to classify whether each data is legitimate or not. The processed data is then converted into Corpus type and Document-Term Matrix. Finally, the two types of 'legal' and 'illegal' files were mixed and randomly divided into learning data set and test data set. In this study, we set the learning data as 70% and the test data as 30%. SVM was used as the discrimination algorithm. Since SVM requires gamma and cost values as the main parameters, we set gamma as 0.5 and cost as 10, based on the optimal value function. The cost is set higher than general cases. To show the feasibility of the idea proposed in this paper, we compared the proposed method with MLE (Maximum Likelihood Estimation), Term Frequency, and Collective Intelligence method. Overall accuracy and was used as the metric. As a result, the overall accuracy of the proposed method was 92.41% of illegal loan advertisement and 77.75% of illegal visit sales, which is apparently superior to that of the Term Frequency, MLE, etc. Hence, the result suggests that the proposed method is valid and usable practically. In this paper, we propose a framework for crisis management caused by abnormalities of unstructured data sources such as SNS. We hope this study will contribute to the academia by identifying what to consider when applying the SVM-like discrimination algorithm to text analysis. Moreover, the study will also contribute to the practitioners in the field of brand management and opinion mining.

K-DEV: A Borehole Deviation Logging Probe Applicable to Steel-cased Holes (철재 케이싱이 설치된 시추공에서도 적용가능한 공곡검층기 K-DEV)

  • Yoonho, Song;Yeonguk, Jo;Seungdo, Kim;Tae Jong, Lee;Myungsun, Kim;In-Hwa, Park;Heuisoon, Lee
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.4
    • /
    • pp.167-176
    • /
    • 2022
  • We designed a borehole deviation survey tool applicable for steel-cased holes, K-DEV, and developed a prototype for a depth of 500 m aiming to development of own equipment required to secure deep subsurface characterization technologies. K-DEV is equipped with sensors that provide digital output with verified high performance; moreover, it is also compatible with logging winch systems used in Korea. The K-DEV prototype has a nonmagnetic stainless steel housing with an outer diameter of 48.3 mm, which has been tested in the laboratory for water resistance up to 20 MPa and for durability by running into a 1-km deep borehole. We confirmed the operational stability and data repeatability of the prototype by constantly logging up and down to the depth of 600 m. A high-precision micro-electro-mechanical system (MEMS) gyroscope was used for the K-DEV prototype as the gyro sensor, which is crucial for azimuth determination in cased holes. Additionally, we devised an accurate trajectory survey algorithm by employing Unscented Kalman filtering and data fusion for optimization. The borehole test with K-DEV and a commercial logging tool produced sufficiently similar results. Furthermore, the issue of error accumulation due to drift over time of the MEMS gyro was successfully overcome by compensating with stationary measurements for the same attitude at the wellhead before and after logging, as demonstrated by the nearly identical result to the open hole. We believe that the methodology of K-DEV development and operational stability, as well as the data reliability of the prototype, were confirmed through these test applications.

The nanoleakage patterns of experimental hydrophobic adhesives after load cycling (Load cycling에 따른 소수성 실험용 상아질 접착제의 nanoleakage 양상)

  • Sohn, Suh-Jin;Chang, Ju-Hae;Kang, Suk-Ho;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.9-19
    • /
    • 2008
  • The purpose of this study was: (1) to compare nanoleakage patterns of a conventional 3-step etch and rinse adhesive system and two experimental hydrophobic adhesive systems and (2) to investigate the change of the nanoleakage patterns after load cycling. Two kinds of hydrophobic experimental adhesives, ethanol containing adhesive (EA) and methanol containing adhesive (MA), were prepared. Thirty extracted human molars were embedded in resin blocks and occlusal thirds of the crowns were removed. The polished dentin surfaces were etched with a 35 % phosphoric acid etching gel and rinsed with water. Scotchbond Multi-Purpose (MP), EA and MA were used for bonding procedure. Z-250 composite resin was built-up on the adhesive-treated surfaces. Five teeth of each dentin adhesive group were subjected to mechanical load cycling. The teeth were sectioned into 2 mm thick slabs and then stained with 50 % ammoniacal silver nitrate. Ten specimens for each group were examined under scanning electron microscope in backscattering electron mode. All photographs were analyzed using image analysis software. Three regions of each specimen were used for evaluation of the silver uptake within the hybrid layer. The area of silver deposition was calculated and expressed in gray value. Data were statistically analyzed by two-way ANOVA and post-hoc testing of multiple comparisons was done with the Scheffe's test. Silver particles were observed in all the groups. However, silver particles were more sparsely distributed in the EA group and the MA group than in the MP group (p < .0001). There were no changes in nanoleakage patterns after load cycling.