• 제목/요약/키워드: Mechanical Index

검색결과 1,373건 처리시간 0.028초

Efficacy of glycine powder air-polishing in supportive periodontal therapy: a systematic review and meta-analysis

  • Zhu, Mengyuan;Zhao, Meilin;Hu, Bo;Wang, Yunji;Li, Yao;Song, Jinlin
    • Journal of Periodontal and Implant Science
    • /
    • 제51권3호
    • /
    • pp.147-162
    • /
    • 2021
  • Purpose: This systematic review and meta-analysis was conducted to assess the effects of glycine powder air-polishing (GPAP) in patients during supportive periodontal therapy (SPT) compared to hand instrumentation and ultrasonic scaling. Methods: The authors searched for randomized clinical trials in 8 electronic databases for relevant studies through November 15, 2019. The eligibility criteria were as follows: population, patients with chronic periodontitis undergoing SPT; intervention and comparison, patients treated by GPAP with a standard/nozzle type jet or mechanical instrumentation; and outcomes, bleeding on probing (BOP), patient discomfort/pain (assessed by a visual analogue scale [VAS]), probing depth (PD), gingival recession (Rec), plaque index (PI), clinical attachment level (CAL), gingival epithelium score, and subgingival bacteria count. After extracting the data and assessing the risk of bias, the authors performed the meta-analysis. Results: In total, 17 studies were included in this study. The difference of means for BOP in patients who received GPAP was lower (difference of means: -8.02%; 95% confidence interval [CI], -12.10% to -3.95%; P<0.00001; I2=10%) than that in patients treated with hand instrumentation. The results of patient discomfort/pain measured by a VAS (difference of means: -1.48, 95% CI, -1.90 to -1.06; P<0.001; I2=83%) indicated that treatment with GPAP might be less painful than ultrasonic scaling. The results of PD, Rec, PI, and CAL showed that GPAP had no advantage over hand instrumentation or ultrasonic scaling. Conclusions: The findings of this study suggest that GPAP may alleviate gingival inflammation more effectively and be less painful than traditional methods, which makes it a promising alternative for dental clinical use. With regards to PD, Rec, PI, and CAL, there was insufficient evidence to support a difference among GPAP, hand instrumentation, and ultrasonic scaling. Higher-quality studies are still needed to assess the effects of GPAP.

실내 공간 내 지향성 마이크 어레이에서의 음성 명료도 개선을 위한 벽면 흡음 처리 방법 (A method of wall absorption treatment for enhancing the speech intelligibility at a directional microphone array in a room)

  • 고병윤;이정권;조완호
    • 한국음향학회지
    • /
    • 제40권6호
    • /
    • pp.649-659
    • /
    • 2021
  • 벽면 흡음 처리는 잔향의 제어에는 효과적이나, 잔향이 큰 공간의 경우에는 넓은 면적에 대한 적용이 필요하며, 각 벽면의 흡음은 음성 명료도에 다르게 영향을 미친다. 본 연구에서는 실내 음성 명료도의 관점에서 빔포밍 수음장치에 대한 잔향 제어를 위해 흡음 처리가 가장 효과적인 벽을 선택하는 모사 방법을 제안한다. 고정된 위치의 빔포밍 수음어레이에 대해, 화자 혹은 스피커에서 방출된 음향이 각 벽면과 충돌하는 변수를 이용해 벽면 중요도 계수를 정의하고, 이를 이용해 흡음 처리에 따른 수음부의 음성개선 효과를 예측하는 방법을 제시했다. 검증을 위해 체적이 107 m3, 잔향 시간이 1.1 s인 직육면체형 실내공간에 대해 모사 실험을 진행했다. 중요도 계수가 가장 높은 벽면에 헬름홀츠 흡음기를 적용할 때 수정된 음성 명료도는 500 Hz, 1 kHz에서 각각 5.1 dB와 4.8 dB, 또 음성전달 지수는 0.06만큼의 향상이 예측되었는데, 이는 상용코드의 계산 결과와 차이인지 역치(Just-Noticeable Difference, JND) 이내의 차이로 일치했다. 분석결과, 벽면 중요도가 가장 높은 곳에 흡음 처리한 결과는 면적이 가장 넓은 천장에 같은 흡음률을 적용할 때보다 음성 명료도 지수가 JND 이상으로 더 개선되는 것을 알 수 있었다.

단양 지질공원 내의 산사태 유형과 특징 (Types and Characteristics of Landslides in Danyang Geopark)

  • 문성우;김호근;서용석
    • 지질공학
    • /
    • 제33권3호
    • /
    • pp.427-438
    • /
    • 2023
  • 본 연구에서는 다양한 암종이 분포하는 단양 지질공원 내에서 발생한 산사태를 대상으로 야외지질조사를 통해 유형을 분류하고, 샘플링 및 실내 시험을 통해 산사태 구성 물질의 역학적‧수리학적 특성을 분석하였다. 토석류 산사태 유형은 석회암 및 대리암, 셰일, 반상변정질 편마암 지역에서 발생하였으며, 석회암 및 대리암 지역에서는 카렌지형의 영향을 받아 암반과 암반 사이의 토사가 붕괴되는 형태로 다른 두 지역의 산사태와 구분된다. 토질시험 결과에서는 조립질 함량이 많은 편마암 풍화토가 다른 두 지역의 풍화토에 비해 내부마찰각이 높고 점착력이 작으며 투수계수가 큰 특징을 보인다. 암반 산사태 유형은 천매암, 사암, 역암 지역에서 발생하였으며, 천매암 지역에서는 평면파괴 형태가, 사암 지역에서는 부석형 낙석 형태가, 역암 지역에서는 전석형 낙석 형태가 발달하고 있다. 천매암의 전단강도는 동일한 암질의 타 암종에 비해 훨씬 낮게 나타나며, 역암의 슬레이크 내구성 지수는 타 암종과 유사하나 시험 전‧후 시료의 상태를 비교하면 기질부의 차별풍화 및 이로 인한 역의 탈락 형태가 뚜렷이 관찰된다. 본 연구의 결과는 지질특성별 산사태 유형에 따른 적절한 보강방안 및 방재대책을 수립하는데 기여할 수 있을 것으로 기대된다.

축방향 서브 나이퀴스트 샘플링 기반의 횡탄성 영상 기법 (Shear-wave elasticity imaging with axial sub-Nyquist sampling)

  • 오우진;윤희철
    • 한국음향학회지
    • /
    • 제42권5호
    • /
    • pp.403-411
    • /
    • 2023
  • 탄성 영상과 미세 혈류 도플러 영상과 같은 기능성 초음파 영상은 조직의 기계적, 기능적 정보를 제공함으로써 진단 성능을 향상시킨다. 그러나 기능성 초음파 영상의 구현은 데이터 획득 및 처리 시 대용량 데이터 저장과 같은 한계를 야기한다. 본 논문에서는 효율적인 횡탄성 영상 기법을 위해 데이터 획득 양을 절감시키는 서브 나이퀴스트 접근법을 제안한다. 제안하는 방법은 기존 나이퀴스트 샘플링 속도보다 1/3배 낮은 샘플링 속도로 데이터를 획득하고, 주파수 스펙트럼의 주기성을 이용하여 대역 통과 필터링 기반의 보간을 통해 재구성된 Radio Frequency(RF) 신호를 사용하여 횡파 신호를 추적한다. 이때 RF 신호는 67 % 미만의 비대역폭으로 제한된다. 제안하는 접근법을 검증하기 위해 기존 샘플링 속도로 획득한 횡파 추적 데이터를 이용하여 서브 나이퀴스트 샘플링된 RF 신호를 재현하고, 기존 접근법과 횡파 속도 영상을 재구성한다. 정량적 평가를 위해 재구성한 횡파 속도 영상의 군속도, 대조도 잡음 비, 그리고 구조적 유사성 지수를 비교하였다. 우리는 서브 나이퀴스트 샘플링 기반 횡탄성 영상의 가능성을 정성적, 정량적으로 입증하였고, 향후 실시간 3차원 횡탄성 영상 기술에 유용하게 적용 가능할 것으로 기대된다.

$C_5$계 수소불화에테르를 기반으로 하는 배합 세정제의 CFC 대체세정제 적용 연구 (A Study on the Applicability of $C_5$ Hydrofluoroether-based Formulated Cleaning Agents as CFC-Alternatives)

  • 민혜진;배재흠;장윤상
    • 청정기술
    • /
    • 제16권3호
    • /
    • pp.172-181
    • /
    • 2010
  • CFC 세정제의 제3 세대 대체세정제로 평가되는 수소불화에테르(hydrofluoroether; HFE)는 불소분자를 함유하고 있어 표면장력이 낮고 습윤지수가 커서 미세입자제거와 불소계 오염물 제거에 우수하고 인화점이 없고 건조성이 뛰어난 물성을 가지고 있지만, 유기물의 용해력은 떨어져 유기 오염물 제거에는 효율적이지 못하다. 본 연구에서는 $C_5$계 HFE인 HFE-7100 [$CF_3CF_2CF_2CF_2OCH_3$]와 HFE-mec-f[$CF_3CHF=CF_2OCH_2CF_3$]에 유기물질의 용해력이 비교적으로 뛰어난 isopropyl alcohol (IPA), ethyleneglycol monoether (EG), propyleneglycol monoethylether (PM)를 인화점이 나타나지 않는 최대량을 각각 첨가하여 $C_5$계 HFE 기반의 배합세정제를 제조하여 물성과 여러 종류의 플럭스, 비수용성 절삭유, 불소계 오일에 대한 세정성 평가를 수행하였다. 실험 결과 $C_5$계 기반의 배합세정제는 단일 불소계 세정제의 여러 가지 물리적 성질의 장점을 가지는 것으로 나타났다. 그리고 $C_5$계 기반의 배합세정제는 첨가된 용제에 따라 약간의 차이는 있지만 대체적으로 플럭스, 비수용성 절삭유, 불소계 오일에 우수한 세정력을 나타내어 여러 산업세정 분야에 적용가능성을 보여주었다.

만성 족관절 불안정성을 가진 환자군에서 변형 브로스트롬 술식과 봉합 테이프를 추가한 술식 간의 결과 비교 (Comparison of the Modified Brostrom Repair Technique with and without Augmentation Using Suture Tape for Chronic Ankle Instability)

  • 곽희철;정수환;김정한;박대현;추혜정;김대유
    • 대한족부족관절학회지
    • /
    • 제26권1호
    • /
    • pp.40-47
    • /
    • 2022
  • Purpose: The modified Broström repair (BR) technique has yielded good outcomes in patients with chronic ankle instability. This study compared clinical and radiological outcomes between two groups of patients who underwent modified BR or lateral ligament augmentation using suture tapes (ST). Materials and Methods: Seventy-seven patients (ST group [n=47], BR group [n=30]; body mass index <26.61 kg/m2; mean age, 30.7±11.0 years [range, 17~39 years]; mean follow-up, 34.0±12.0 months [range, 24~59 months]) were retrospectively reviewed between January 2014 and July 2017. The Foot and Ankle Outcome Score (FAOS), American Orthopedic Foot and Ankle Score (AOFAS), Foot and Ankle Ability Measure (FAAM), visual analogue scale (VAS) score, and Sefton grading system were used for clinical assessment. The talar tilt angle and anterior talar translation were measured using the Telos stress device (Telos GmbH, Marburg, Germany) at 150 N for radiological evaluation. Results: FAOS, AOFAS, FAAM, and VAS scores improved in both groups at final follow-up (ST, 91.1±5.2, 93±2, 88.1±4.5, 1.5±0.7 vs. BR, 91.3±5.4, 93±3, 83.3±4.8, 1.2±0.7, respectively; p=0.854, 0.971, <0.001, 0.04, respectively). According to the FAOS, mean sports activity scores for the ST and BR groups at the final follow-up were 90.3±3.2 and 76.6±4.2, respectively, reflecting superior outcomes in the ST group (p<0.001). Sefton grading revealed satisfactory functional outcomes (ST, 91.5% vs. BR, 90.0%). There was significant improvement in the talar tilt angle and anterior talar translation in both the ST and BR groups (7.6°±1.2°, 10.5±1.8 mm vs. 4.9°±1.1°, 7.9±1.5 mm, respectively; p<0.001). Conclusion: The ST group demonstrated comparable clinical but better improvement in mechanical stability and FAOS sports scores than the BR group.

Experimental and numerical study on the structural behavior of Multi-Cell Beams reinforced with metallic and non-metallic materials

  • Yousry B.I. Shaheen;Ghada M. Hekal;Ahmed K. Fadel;Ashraf M. Mahmoud
    • Structural Engineering and Mechanics
    • /
    • 제90권6호
    • /
    • pp.611-633
    • /
    • 2024
  • This study intends to investigate the response of multi-cell (MC) beams to flexural loads in which the primary reinforcement is composed of both metallic and non-metallic materials. "Multi-cell" describes beam sections with multiple longitudinal voids separated by thin webs. Seven reinforced concrete MC beams measuring 300×200×1800 mm were tested under flexural loadings until failure. Two series of beams are formed, depending on the type of main reinforcement that is being used. A control RC beam with no openings and six MC beams are found in these two series. Series one and two are reinforced with metallic and non-metallic main reinforcement, respectively, in order to maintain a constant reinforcement ratio. The first crack, ultimate load, deflection, ductility index, energy absorption, strain characteristics, crack pattern, and failure mode were among the structural parameters of the beams under investigation that were documented. The primary variables that vary are the kind of reinforcing materials that are utilized, as well as the kind and quantity of mesh layers. The outcomes of this study that looked at the experimental and numerical performance of ferrocement reinforced concrete MC beams are presented in this article. Nonlinear finite element analysis (NLFEA) was performed with ANSYS-16.0 software to demonstrate the behavior of composite MC beams with holes. A parametric study is also carried out to investigate the factors, such as opening size, that can most strongly affect the mechanical behavior of the suggested model. The experimental and numerical results obtained demonstrate that the FE simulations generated an acceptable degree of experimental value estimation. It's also important to demonstrate that, when compared to the control beam, the MC beam reinforced with geogrid mesh (MCGB) decreases its strength capacity by a maximum of 73.33%. In contrast, the minimum strength reduction value of 16.71% is observed in the MC beams reinforced with carbon reinforcing bars (MCCR). The findings of the experiments on MC beams with openings demonstrate that the presence of openings has a significant impact on the behavior of the beams, as there is a decrease in both the ultimate load and maximum deflection.

심장수술시 저체온 체외순환과 정상체온 체외순환의 전신 효과에 관한 연구 (The Systemic Effects of Hypothermic and Normothermic Cardiopulmonary Bypass in Cardiac Surgery)

  • 박재민;조용길;황윤호;이양행;윤영철;전희재;한일용;최석철;조광현
    • Journal of Chest Surgery
    • /
    • 제38권1호
    • /
    • pp.29-37
    • /
    • 2005
  • 저자득은 최근 논의되고 있는 정상체온 체외순환의 임상적 유용성과 생리학적 영향을 규명하기 위해 저체온 체외순환과의 비교 연구를 시행하게 되었다. 대상 및 방법: 심장수술이 계획된 36명의 성인 환자들을 연구목적에 따라 무작위로 중등도 저 체온 체외순환군(이하 저체온군, 비인두 온도$26\~28^{\circ}C,\;n=18)$과 정상체온 체외순환군(이하 정상체온군, 비인두 온도>,$35.5^{\circ}C,\;n=18)$으로 나누었다. 전체 환자들로부터 체외순환 전, 체외순환 중, 체외순환 종료 직후에 각각 혈액을 채취하여 총 백혈구 수, neuron-specific enolase 증가율(NSE), interleukin-6 증가율(IL-6), endothelin-1 (ET-1), cortisol 증가율, troponin I (TNI), aspartate aminotransferase (AST), alanine aminotransferase (ALT), creatinine, blood urea nitrogen (BUN)을 측정하였다. 그 외 수술 중 소변 배출량, 수술 후 페지수$(PaO_{2}/FiO_{2}),$ 기계호흡 보조시간, 중환자실 치료기간, 합병증, 재원일수 등을 조사하여 양 군 간에 비교 평가하였다 결과: 정상체온군이 저체온군에 비해 심장수술 동안 총 백혈구 수, NSE 증가율, IL-6 증가율, cortisol 증가율은 유의하게 더 높았으나 소변 배출량은 더 낮았다. 또한 기계 호흡 보조 시간, 중환자실 치료기간, 재원일수 역시 정상체온군이 저체온군보다 유의하게 더 길었다. 결론: 저자들의 연구 결과를 볼 때 정질 냉각 심정지액을 이용한 심장 수술 동안 정상체온 체외순환은 중등도저체온 체외순환보다 더 높은 염증 및 스트레스 반응을 유도하여 생리학적으로 유해할 것으로 생각된다. 그러나 좀더 많은 환자 수를 대상으로 한 추가적 연구가 필요할 것으로 판단된다.

기계적 환기 요법을 시행 받은 미숙아에서 고탄산혈증과 뇌실내 출혈의 발생과의 관계 (Association of Hypercapnia in the First Week of Life with Severe Intraventricular Hemorrhage in the Ventilated Preterm Infants)

  • 김정은;남궁란;박민수;박국인;이철;김명준
    • Neonatal Medicine
    • /
    • 제17권1호
    • /
    • pp.34-43
    • /
    • 2010
  • 목 적 : 기계적 환기요법을 시행 받은 미숙아에서 생후 첫 7일 동안 고탄산혈증과 중증 뇌실내 출혈의 발생과의 연관성을 알아보고자 본 연구를 시행하였다. 방 법:출생 후 7일 이상 기계적 환기 요법을 받은 재태주령 37주 미만의 미숙아를 대상으로 하여, 3단계 이상의 뇌실내 출혈로 진단받은 경우 IVH 군(n=19)으로, 정상 또는 1단계 뇌실내 출혈을 보인 경우, 출생 체중과 주수를 대응하여 대조군(n=38)으로 선정하였다. 두 군간의 생후 첫 7일 동안 혈중 이산화탄소 분압($PaCO_2$)의 최대값, 최소값, 평균값과 변화 정도(fluctuation)를 측정하기 위한 지표로 혈중 이산화탄소 분압의 최대값과 최소값의 차이(maximum-minimum)와 평균값의 표준편차를 비교 분석하였다. 결 과:재태주령과 출생체중은 IVH 군은 26.9$\pm$1.7주, 975.3$\pm$262.5g이었고, 대조군은 26.8$\pm$1.5주, 915.6$\pm$198.2 g이었다. IVH 군에서 생후 7일 동안 혈중 이산화탄소 분압의 최대값(IVH 군 vs. 대조군, 86.1$\pm$ 18.4 mmHg vs. 60.1$\pm$11.6mmHg, P <0.001), 평균값 (47.5$\pm$5.6 mmHg vs. 41.2$\pm$6.3mmHg, P=0.004), 최대값과 최소값의 차이(60.3$\pm$20.9 mmHg vs. 35.5$\pm$ 11.8 mmHg, P < 0.001), 평균값의 표준편차(14.0$\pm$4.4mmHg vs. 9.0$\pm$2.4 mmHg, P <0.001)는 유의하게 높았으나 최소값은 두 군 간의 차이가 없었다. 또한 IVH군에서 파종성혈관내응고[11 (57.9%):9 (23.7%), P=0.011], 폐출혈[12 (63.2%):10 (26.3%), P=0.007], 공기누출 증후군[4 (21.1%):1 (2.6%), P=0.021]의 빈도가 많았고, 생후 7일 동안 인공 호흡기 지수의 최대값이 통계적으로 유의하게 높았다. 출혈성 경향, 공기누출증후군, 인공 호흡기 지수의 영향력을 통제한 후에는 혈중 이산화탄소 분압의 최대값이 odds ratio 1.324 (95%CI: 1.011-1.733, P=0.041)로 중증 뇌실내 출혈과 통계적으로 유의한 연관성을 보였다. 결 론 : 기계적 환기 요법을 시행 받은 미숙아에서 출생 후 첫 7일 동안 극심한 고탄산혈증은 뇌출혈의 다른 위험 인자의 영향을 배제한 후에도 중증 뇌실내 출혈의 발생과 연관성을 보였다. 따라서 생후 초기에 호흡기 유발 폐손상을 막기 위해 고탄산혈증을 허용하는 시도는 중요하지만, 과도한 고탄산혈증과 심한 이산화탄소 분압의 변화를 피하고 적절한 이산화탄소 분압을 유지하는 노력이 필요할 것으로 생각된다.

관상동맥-폐동맥 이상 기시증에 대한 수술의 조기 결과 (Early Result of Surgical Management of the Anomalous Origin of the Left Coronary Artery from the Pulmonary Artery)

  • 윤유상;박정준;윤태진;김영휘;고재곤;박인숙;서동만
    • Journal of Chest Surgery
    • /
    • 제39권1호
    • /
    • pp.18-27
    • /
    • 2006
  • 배경: 관상동맥 폐동맥 이상 기시증(Anomalous origin of the left coronary artery from the pulmonary artery; ALCAPA)은 드문 선천성 심장병으로, 아이들에게 있어 심근경색 및 허혈성 심장병의 가장 흔한 원인 중 하나이다. 치료하지 않을 경우 출생 1년 내에 높은 사망률을 보이며, 진단 즉시 이중관상동맥 체계로 수술적 교정을 해주는 것이 치료 원칙이다. 아직 국내의 임상 경험 및 결과에 대한 보고가 드물어 본원의 경험을 공유하고자 한다. 대상 및 방법: 서울아산병원에서는 1989년 6월부터 2003년 7월까지 수술을 시행한 6예의 좌관상동맥 폐동맥 이상 기시증과 1예의 우관상동맥 폐동맥이상 기시증 환아를 대상으로 하여 심전도, 단순흉부촬영 및 심초음파 소견 등을 후향적으로 검토하였다. 결과: 환아들 중 남아는 3명이고, 여아는 4명이었으며, 수술 당시 환아의 연령은 중앙값 5.4개월(3$\∼$33개월)이였다. 환아의 몸무게는 평균 6.7$\pm$2.6 kg (3.7$\∼$11.3 kg)이었고, 진단은 3명만이 초기에 좌 관상동맥 폐동맥 이상 연결증으로 정확히 진단되었고, 4명은 다른 진단으로 입원하였다. 수술은 이중관상동맥 체계의 형성을 원칙으로 직접 좌관상동맥-대동맥 이식술을 시행하였다. 체외순환 시간은 114$\pm$37분, 대동맥차단 시간은 55$\pm$22분이었다. 이차성 심방중격결손의 단순 봉합이 1예, 승모판 성형술이 2예에서 동반 시술되었다. 중환자실 재원일은 평균 5일, 인공호흡기 보조시간은 평균 38시간이며, 술 후 입원기간은 평균 12일이었다. 심전도와 흘부 단순 촬영 소견은 만기 사망한 한 예를 제외하고 모두 호전되었으며, 좌심실 기능의 회복도 거의 정상적으로 회복되어, 수술 후 1년 내에 실시한 심초음파 검사에서 좌심실 박출률(EF: Ejection fraction)은 평균 41.2$\pm$10.3$\%$에서 평균 $59.8{\pm}13.9\%$로, 좌심실 수축률(Shortening Fraction)은 평균 23.6$\pm$4.7$\%$에서 37.4$\pm$7.9$\%$로 호전되었고, 좌심실의 수축기말의 용적지수(LVEDDI: Left ventricular end-diastolic dimension index to body surface area)는 수술 전100.8$\pm$25.6 mm/$m^{2}$에서 79.3$\pm$ 15.8 mm/$m^{2}$로 감소한 소견을 보였다. 승모판 성형술은 전 승모판엽 탈출증이 있는 두 환아에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.