• 제목/요약/키워드: Measuring methods

검색결과 4,442건 처리시간 0.033초

암환자의 수분 균형 상태 사정 방법 비교: 수분 섭취 및 배설량 측정법과 체중측정법 (Measuring Fluid Balance in Patients with Cancers: Comparison between Cumulative Intake and Output Records and Body Weight Change)

  • 이진홍;박희정;김정화;서은영
    • 종양간호연구
    • /
    • 제11권3호
    • /
    • pp.247-253
    • /
    • 2011
  • Purpose: The purpose of the study was to evaluate the accuracy of two different fluid intake measurement methods (fluid only vs. all dietary intake) in measuring fluid balance compared to body weight change among patients with cancers. Methods: A total of 60 cancer patients in an urban cancer center in South Korea participated in the study. Adult patients who were over 18 years old; having 24-hour I&O order; and taking either normal regular diet or soft blend diet were included. Demographic information and disease related information were also gathered. The data were analyzed using SPSS 18.0 program. Results: Measuring 'fluid only' for oral intake was a more accurate measure than measuring 'all dietary intake' (p=.026 vs. p=.094). Both methods had positive correlations with the amount of weight change (r=.329, p=.010; r=.303, p=.019). Measuring body weight was a more accurate and efficient way of evaluating the fluid balance than 24 hour cumulative I&O. Conclusion: Developing clinical manual for selecting proper patients who needs fluid balance monitoring is imperative. Administering weight check and/or 24 hour cumulative I&O should be considered thoroughly based on solid nursing evidence in future.

지능형 칼라 맞춤 및 조제 시스템 설계 (Design of Intelligent Type for Color Matching and Measuring Systems)

  • 류상문;한일석;박병준;안태천
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.156-156
    • /
    • 2000
  • In this paper, a new method for colour measuring is presented using fuzzy modeling technique. The fuzzy and polynomial inferences are used for obtaining RGB characteristic curve. The eight RGB real data from expert dye-stuff manufacturer, are simulated. The results show that the proposed method will is more excellent than other methods, in the colour measuring process of textile field.

  • PDF

퍼지 모델링 기법을 이용한 새로운 칼라 메저링 방법 (A New Method for Colour Measuring Using Fuzzy Modeling Technique)

  • 류상문;한일석;박병준;안태천
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2000년도 춘계학술대회 학술발표 논문집
    • /
    • pp.183-186
    • /
    • 2000
  • In this paper, a new method for colour measuring is presented using fuzzy modeling technique. The fuzzy and polynomial inferences are used for obtaining RGB characteristic curve. The eight RGB real data from expert dye-stuff manufacturer, are simulated. The results show that the proposed method will is more excellent than other methods, In the colour measuring process of textile field.

  • PDF

노년 여성 체형의 표준화된 3차원 측정 데이터 추출을 위한 기초 연구 (A Basic Study Contributes to Extract the Standardized 3D Body Data for Women Aged 60 and Older)

  • 이정임;주소령
    • 한국의류학회지
    • /
    • 제28권2호
    • /
    • pp.344-353
    • /
    • 2004
  • The purpose of this study was to offer the basis contributes to extract the standardized body data from 3D body measuring for women aged 60 and older. The WB4 of Cyberware was used, and the measuring program of 3D scanning data was 3DM. This study was focused to verify the reliability of 3D data and to offer the effective utilization of 3D measuring on the research for elderly women■s body. Subjects were 19 women aged 60 and older. And three women in late twenties and three dressforms for women were comparing subjects to analyze the signiscant difference by age or human body variable making error. First, 3D scanning was executed twice on each subject, but any significant difference was not appear between two scanning data. So we certifed we could get the consistent and reliable data from the 3D scanner used in this study. Second, the reliability of 3D measuring data was analyzed, and the error range which meant the difference between 3D data and traditional measuring data was analyzed. In elderly women, the significant difference between two data was appeared in 19 body parts. The 7 of 19 were concerned with armpit point. In young women, three significant difference were appeared, and in dressforms, any significant difference was not certified. From these results, we could certify that age or human body variable produced the difference between two data. Third, the data of elderly women from three measuring methods, 3D measuring, traditional measuring, and measuring on 2D photographs were compared. From the result, we found that the 3D measuring data was quite reliable for most body parts excluding some width parts. But in elderly women, there were some limitation to extract reliable data because of their unique body characteristics. In order to be a role of the effective measuring method, the 3D measuring protocol reflected the body characteristics of each age or gender had to be prepared.

ISO 방법론 및 1:10 축소잔향실을 이용한 확산률 측정 (Measuring Scattering Coefficient in 1:10 Reverberation Chamber Using the ISO Method)

  • 전진용;이병권;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.252-256
    • /
    • 2001
  • Scattering of surface materials has been known as one of the most important aspects in evaluating the acoustics of concert halls are designed. One of the methods that can reduce the errors in estimating the reverberation time and other acoustic parameters through computer modeling is to calculate scattering coefficient of surface materials. However. so far, no objective and reliable methods measuring scattering coefficient has been suggested. In this situation, ISO has suggested the method of measuring the random-incidence scattering coefficient on surfaces in diffuse field, whereas AES has introduced a method on directional-incidence in free field. In this study, the scattering coefficients of five kinds of hemispheres (1.5, 2.0. 2.5. 3.0. 3.5cm) were measured by using the ISO method in 1:10 reverberation chamber. It was found that 3.0cm hemisphere has the highest scattering coefficient satisfying 95% reliability.

  • PDF

공작기계의 오차요소 측정을 통한 3차원 위치정밀도 향상 (The enhancement of 3-dimensional positioning accuracy by measuring error factors for CNC machine tools)

  • 손진욱;서석환;정세용;이응석;위현곤
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.260-265
    • /
    • 1994
  • Efforts have been devoted to developing rapid and accurate methods for measuring the errors of machine tools. The method os measurement and calibration of machine tool errors should be general and efficient. The objective of this study is to show in detail the full sequence from the measurement of errors factors to the verification of the positioning accuracy after compensation for the volumetric error. In this paper, we described the steps in measuring the volumetric error parameters, a general error model composed of error parameters, temperature, and the desired position. The validity of the error calibration methods proposed in this paper was tested using a vertical 3-axis CNC machine with a laser interferometer and a ball bar.

  • PDF

PCM의 잠열측정을 위한 T-history법에 대한 고찰 (Consideration on the T-history Method for Measuring Heat of Fusion of Phase Change Materials)

  • 박창현;최주환;홍희기
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1223-1229
    • /
    • 2001
  • Though conventional calorimetry methods such as differential scanning calorimetry (DSC) and differential thermal analysis (DTA) are used generally in measuring heat of fusion, T-history method has the advantages of a simple experimental apparatus and no requirements of sampling process, which is particularly useful for measuring thermal properties of inhomogeneous phase change materials (PCMs) in sealed tubes. However, random criteria (a degree of supercooling) used in selecting the range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion. In the present study, it was shown that a 40% discrepancy exists between the original T-history and the present methods when analyzing the same experimental data. As a result, a reasonable modification to the original T-history method is proposed.

  • PDF

MEASUREMENT OF SIZE DISTRIBUTION OF DIESEL PARTICLES: EFFECTS OF INSTRUMENTS, DILUTION METHODS, AND MEASURING POSITIONS

  • KIM H.;LEE S.;KIM J.;CHO G.;SUNG N.;JEONG Y.
    • International Journal of Automotive Technology
    • /
    • 제6권2호
    • /
    • pp.119-124
    • /
    • 2005
  • Size distribution of diesel particles measured by ELPI and SMPS were compared. The results of ELPI and SMPS showed acceptable agreements in the qualitative comparison but showed differences in the quantitative comparison. In addition, the results of ELPI and SMPS showed a same trend about the change of engine loads. In this study, the effects of dilution methods and measuring positions on the measurement of PM size distribution were also studied by using the SMPS. As results, the decrease of large particles and the increase of small particles were observed when the dilution air was heated. It was also observed that the number concentration of the diesel particles was varied within 20$\%$ by the different measuring positions of 140 cm.