• Title/Summary/Keyword: Measuring methods

Search Result 4,472, Processing Time 0.035 seconds

Skeletal maturation associated with the fourth cervical vertebra and menarcheal timing (제4경추의 형태와 초경을 통한 성숙지표에 관한 연구)

  • Lee, Kyu-Hong;Hwang, Yong-In;Kim, Yoon-Ji;Baek, Seung-Hak;Cha, Kyung-Suk;Park, Yang-Ho
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.52-59
    • /
    • 2008
  • Objective: This study analyzed the morphologic changes of the fourth cervical vertebra body to determine the skeletal age of orthodontic patients during growth. Methods: Eighty-one female patients aged from 11 to 14 who had cephalograms taken on the same day were examined. The subjects were divided into three groups depending on the depth of the concavity of the lower border of the fourth cervical vertebra (Group A: less than 1.05 mm, Group B: 1.05 - 2.07 mm, Group C: greater than 2.07 mm). Menarcheal timing, SMI stage, length, width and ratio of length and width of the fourth cervical vertebra body were analyzed and the following results were obtained. Results: The average SMI stage of group A, B and C were $5.67{\pm}2.57,\;8.73{\pm}2.41,\;and\;10.00{\pm}1.47$, respectively. Length, width, ratio of length and width, and SMI stage were greater in group B than group A and in group C than group B. Mean menarcheal timing was $11.64{\pm}0.92$ years. Concavity depth, length, width, ratio of length and width showed a significant positive correlation with SMI stage, especially with the concavity depth. Conclusion: The results of this study propose a simple method for determining the timing of orthopedic treatment by measuring the concavity depth of the fourth cervical vertebra on the cephalogram.

A COMPARATIVE STUDY ON THE CHEMICAL COMPOSITION AND MECHANICAL PROPERTIES OF FOUR LOW-GOLD-CONTENT DENTAL CASTING ALLOYS MANUFACTURED IN KOREA (한국산(韓國産) 치과주조용(齒科鑄造用) 저금함유합금(低金含有合金)의 조성(組成) 및 기계적(機械的) 성질(性質)에 관(關)한 비교연구(比較硏究))

  • Chang, Ik-Tae;Yang, Jae-Ho;Kim, Chang-Whe;Kim, Kwang-Nam;Lee, Sun-Hyung;Kim, Yung-Soo;Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.17-27
    • /
    • 1981
  • This study was conducted to determine the chemical composition and the mechanical properties of four commercially available low gold-based crown and bridge alloy produced in Korea. Four dental casting gold-silver-palladium alloys, i.e., A, B, C and D (code of alloys) were selected for the evaluation of chemical composition, ultimate tensile strength, elongation. values and Vickers hardness. The chemical composition of test specimens was analyzed by both emission spectrography and wet gravitation method with a 1.5gm of low gold ingot. The tensile properties and Vickers hardness was determined with cast specimens treated in following three conditions; as-cast, softening heat treatment and hardening heat treatment. The tensile testing bars were cast in accordance with the model designed by Gettleman and Harrison (1969) which was modified from the A. D. A. Specification No. 14 for dental chromium-cobalt casting alloy. Nine tensile test specimens were made from a split silicone mold for each of the test alloys to the size of 2.5mm in diameter and a gauge length of 10mm. All four alloys were handled in accordance with conventional methods used in Type III gold alloys. Ultimate tensile strength and elongation were measured on an Instron Universal Tensile Testing Machine (Model 1125, Japan) operated at a crosshead rate of 0.1cm/min. Elongation values were measured using Digital Measuring Microscope (MS-152, FUSOH, Japan). Vickers hardness was determined with a Vickers Hardness Tester (Model VKH-l, Japan) at a 1.0kg load on a mounted tensile test specimen. The following results were obtained from this study; 1. All tested alloys were composed of Au, Ag, Pd, Cu, Zn and Fe in common. The composition rate of gold for all four alloys was found in the range of $42{\sim}47$ weight % as shown below. Alloy A; Au 45%, Ag 40.2%, Pd 5.76%, others 9.04%. Alloy B; Au 47.1%, Ag 29.03%, Pd 6.98%, others 16.92%. Alloy C; Au 45%, .Ag 26.9%, Pd 6.83%, others 21.07%. Alloy D; Au 41.8%, Ag 34.4%, Pd 6.95%, others 16.85%. 3. The ultimate tensile strength of the four alloys was in the range of $31{\sim}82kg/mm^2$. The test results were shown in the below order from the highest value; As-cast condition; D, B, C, A. Softening heat treament; B, C, D, A. Hardening heat treatment; D, B, C, A. 4. The test :results of the elongation rate for each alloy were in the range of $0.5{\sim}18%$. The test results were shown in the below order from the highest value; As-cast condition; A, D, B, C. Softening heat treatment; A, C, D, B. Hardening heat treatment; C, D, B, A. 5. Vickers hardness for each of the four alloys was in the range of $120{\sim}230$. The test results were shown in the below order from the highest value; As-cast condition; C, B, D, A Softening heat treatment; D, B, C, A. Hardening heat treatment; D, A, C, B. 6. There were no differences in the physical properties between as-cast condition and softening heat treatment.

  • PDF

Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR (도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교)

  • Yuh, Chi-Sung;Kim, Jee-Hwan;Kim, Sun-Jai;Lee, Yong-Keun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.416-423
    • /
    • 2009
  • Statement of problem: The degree of light attenuation at the time of cementation of the PLV restoration depends on characteristics such as thickness, opacity and shade of the restorations, which interfere with light transmittance and, as a result, may decrease the total energy reaching the luting cement. Purpose: The purpose of this study was to compare the degree of conversion of light-cured resin cements measuring by FT-IR in regard to different thickness, light devices and curing time. Material and methods: In the control group, a clear slide glass (1.0 mm) was positioned between the light cured resin cement and light source. The specimens of ceramics were made with IPS Empress Esthetic. The ceramics were fabricated with varying thicknesses-0.5, 1.0, 1.5 mm with shade ETC1. Rely $X^{TM}$ Veneer with shade A3, light-cured resin cement, was used. Light-activation was conducted through the ceramic using a quartz tungsten halogen curing unit, a light emitting diode curing unit and a plasma arc curing unit. The degree of conversion of the light-cured resin cement was evaluated using FT-IR and OMNIC. One-way ANOVA and Tukey HSD test were used for statistical analysis ($\alpha$< .05). Results: The degree of conversion (DC) of photopolymerization using QTH and LED was higher than results of using PAC in the control group. After polymerization using QTH and LED, the DC results from the different ceramic thickness- 0.5 mm, 1.0 mm, 1.5 mm- did not show a significant difference when compared with those of control group. However, the DC for polymerization using PAC in the 1.5mm ceramic group showed significantly lower DC than those of the control group and 0.5 mm ceramic group (P<.05). At 80s and 160s, the DC of light-cured resin cement beneath 1.0 mm ceramic using LED was significantly higher than at 20s (P<.05). Conclusion: Within the limitation of this study, when adhering PLV to porcelain with a thickness between 0.5-1.5 mm, the use of PAC curing units were not considered however, light cured resin cements were effective when cured for over 40 seconds with QTH or LED curing units. Also, when curing the light cured resin cements with LED, the degree of polymerization was not proportional with the curing time. Curing exceeding a certain curing time, did not significantly affect the degree of polymerization.

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.

The influence of implant diameter, length and design changes on implant stability quotient (ISQ) value in artificial bone (임플란트의 직경, 길이 및 디자인변화가 임플란트 안정성지수(ISQ)에 미치는 영향)

  • Lee, Jeong-Yol;Lee, Won-Chang;Kim, Min-Soo;Kim, Jong-Eun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.292-298
    • /
    • 2012
  • Purpose: The purpose of this study is to ascertain the stability of the implant by comparing the effects of the change of implant diameter, length and design on implant stability quotient. Materials and methods: To remove the variable due to the difference of bone quality, the uniform density (0.48 g/$cm^3$) Polyuretane foam blocks (Sawbones$^{(R)}$, Pacific Research Laboratories Inc, Vashon, Washington) were used. Implants (Implantium$^{(R)}$, Dentium, Seoul, Korea) were placed with varying diameters (${\phi}3.8$, ${\phi}4.3$ and ${\phi}4.8$) and length (8 mm, 10 mm and 12 mm), to assess the effect on implant stability index (ISQ). Also the influence of the design of the submerged and the non-submerged (SimplelineII$^{(R)}$, Dentium, Seoul, Korea) on ISQ was evaluated. To exclude the influence of insertion torque, a total of 60 implants (n = 10) were placed with same torque to 35 N. Using Osstell$^{TM}$ mentor (Integration Diagnostic AB, Sweden) ISQ values were recorded after measuring the resonant frequency, one-way ANOVA and Tukey HSD test results were analyzed. (${\alpha}$=0.05). Results: 1. The change of the diameter of the implant did not affect the ISQ (P>.05), but the increase of implant length increased the ISQ(P<.001). 2. The change in implant design were correlated with the ISQ, and the ISQ of submerged design was significantly higher than that of the non-submerged design(P<.05). Conclusion: In order to increase implant stability, the longer implant is better to be selected, and on the same length of implant, submerged design is thought to be able to get a higher ISQ than the non-submerged.

Assessment of Nutrition Status and Quality of Life after Curative Resection in Patients with Upper Gastric Cancer: Comparison of Total Gastrectomy and Proximal Gastrectomy (상부 위암에 대한 근위부 위절제술 뜻 위전절제술을 시행한 환자의 영양상태와 삶의 질 비교)

  • Lee, Hyun-Soo;Park, Jong-Hyun;Choi, Hun;Kim, Jae-Hee;Min, Lac-Kee;Lee, Sang-Il;Noh, Seung-Moo
    • Journal of Gastric Cancer
    • /
    • v.5 no.3 s.19
    • /
    • pp.152-157
    • /
    • 2005
  • Purpose: A total gastrectomy is generally peformed for the treatment of upper third gastric cancer. However, the optimal extent of resection for early-stage upper third gastric cancer is still controversial. In this research, we compared the nutritional status and the quality of life in patients who underwent a total gastrectomy with uncut Roux en Y esophagojejunostomy with those in patients who underwent a proximal gastrectomy with esophagogastrostomy for treatment of upper third gastric cancer. Materials and Methods: We reviewed 50 patients with no evidence of recurrent disease following curative surgery for upper third gastric cancer. Among this group, 25 patients underwent a total gastrectomy (TG) and 25 patients a proximal gastrectomy (PG). 8 TG and 4 PG patients were excluded from this study because of death, refusal to interview etc. The nutritional status was assessed by measuring body weight, serum albumin, serum hemoglobin, and serum total protein. The gastrointestinal function and the quality of life were assessed by Cuschieri grading and modified Visick qrading. Results: In analysis of covariance of age and preoperative serum albumin, PG patients demonstrated lower weight loss (P=0.038), elevated serum albumin (P=0.049), and better outcome based on modified Visick grading (P=0.016) than TG, but there were no significant differences in the serum hemoglobin change (P=0.165), serum total protein change (P=0.435), and Cuschieri grading (P=0.064) between the preoperative and the postoperative data. Conclusion: In this study, a proximal gastrectomy led to a better nutritional status and quality of life than a total gastrectomy, as judged from the low weight loss, elevated serum albumin and better modified Visick grade.

  • PDF

Characteristics of Physiological Variables(EDR, EMG) in Biofeedback Treatment (바이오피이드백 치료에서 나타나는 신체변수(EDR, EMG)의 특성)

  • Seo, Man-Kil;Han, Woo-Sang;Lee, Kyung-Kyu;Yu, Bum-Hee;Lee, Yu-Ri;Kim, E-Yong;Kim, Hyun-Woo
    • Sleep Medicine and Psychophysiology
    • /
    • v.6 no.1
    • /
    • pp.38-45
    • /
    • 1999
  • Objectives: We explored the characteristics of physiological variables such as electrodermal response(EDR) and electromyography(EMG) in patients with insomnia, panic disorder, and other anxiety disorders. we aimed to decide the minimum sessions in biofeedback treatment to make the treatment effective and examine the effects of long-term biofeedback treatment by measuring the physiological variables. Methods: Thirty seven outpatients who received biofeedback treatment were divided into 3 groups according to the number of biofeedback sessions(patients who received 4-5 sessions, who received 6-9 sessions, and who received more than 10 sessions). We measured mean and delta values of EDR and EMG levels, and the Hamilton Anxiety Rating Scale(HARS), and Slef-Relaxation Inventory(SRI) in all patients. Data were analyzed by t-test and repeated measures analysis of variance. Results: The mean and delta values of EDR and EMG levels were not different among the 3 groups during the first 4 biofeedback sessions. However, patients who received more than 10 biofeedback sessions had higher baseline mean EDR value(F=2.233, p=0.036) in the first session, compared with other patients. In patients who received more than 10 biofeedback sessions, mean EDR was significantly reduced after $5^{th}$ session(F=10.41, p<0.01). They showed significant improvement in SRI scores at 12th biofeedback session(t=2.726, p<0.05) and in HARS scores at $6^{th}$(t=3.10, p<0.05) and $12^{th}$ biofeedback session(t=10.93, p<0.001). Conclusions: Wesuggest that patients should receive more than 5 biofeedback sessions to experience internal cues and get a good clinical response to biofeedback treatment.

  • PDF

Supplemental Value of the Wrist-Worn Actigraphy in Diagnosing the Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증 진단에서 손목부착형 활동기록기의 보조적 진단가치)

  • Im, Mee-Hyang;Shin, Hong-Beom;Lee, Yu-Jin;Lee, Seung-Hi;Won, Chang-Yeon;Lee, Myung-Hee;Lee, Soo-Young;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.12 no.1
    • /
    • pp.32-38
    • /
    • 2005
  • Objectives: Obstructive sleep apnea syndrome (OSAS) has drawn increasing attention as medical community has become to be aware of its co-morbidities and complications, especially cardiovascular complications and excessive daytime sleepiness with accident proneness. As of now, polysomnography is the standard tool to diagnose sleep apnea and estimate the treatment validity. However, its being rather expensive and inconvenient, alternate diagnostic tools have been proposed including wrist actigraphy. So far, actigraphies have been adopted usefully to field-survey sleep apnea prevalence. In this study, we attempted in a sleep laboratory setting to assess the supplemental value of actigraphy in diagnosing OSAS. Methods: This study was done at the Division of Sleep Studies, the Seoul National University Hospital. Thirty-seven clinically suspected cases of OSAS underwent the one-night polysomnography, simultaneously wearing an actigraphy on non-dominant wrist. We analyzed the data of 27 polysomnographically-proven OSAS patients (male:female 20: 7;age $47.6{\pm}12.9$ years old;age range 23 to 72 years) with no other sleep disorders. We calculated RDI (respiratory disturbance index) from the polysomnography data and FI (fragmentation index) from the actigraphy data. Pearson correlation was calculated in order to compare FI with RDI and to evaluate the supplemental diagnostic value of the actigraphy. Results: Mean total sleep time on polysomnography was $401.4{\pm}57.8\;min$ (range of 274.0 to 514.1 min). Mean RDI was $21.7{\pm}20.4/hour$. Mean FI was $21.9{\pm}13.0/hour$. RDI and FI showed significant correlation (r=0.55, p<0.01). Conclusions: Wrist actigraphy in OSAS patients generates a comparable outcome to polysomnography, in measuring the nocturnal sleep fragmentation. The actigraphy could be used supplementally in inpatients, outpatients, and field survey subjects, if polysomnography is unavailable or impossible. In follow-ups related with nasal CPAP (continuous positive airway pressure), upper airway surgery, and oral appliance in OSAS patients, the actigraphy might play a more dominant role in the future.

  • PDF

An Evaluation of the Accuracy of Mini-Wright Peak Flow Meter (mini-Wright Peak Flow Meter에 의한 PEFR 측정의 정확도)

  • Koh, Young-Il;Choi, In-Seon;Na, Hyun-Ju;Park, Seok-Chae;Jang, An-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.298-308
    • /
    • 1997
  • Background : Portable devices for measuring peak expiratory flow(PEF) are now of proved value in the diagnosis and management of asthma and many lightweight PEF meters have become available. However, it is necessary to determine whether peak expiratory flow rate(PEFR) measurements measured with peak flowmeters is accurate and reproducible for clinical application. The aim of the present study is to define accuracy, agreement, and precision of mini-Wright peak flow meter(MPFM) against standard pneumotachygraph. Methods : The lung function tests by standard pneumotachygraph and PEFR measurement by MPFM were performed in a random order for 2 hours in 22 normal and 17 asthmatic subjects and also were performed for 3 successive days in 22 normals. Results : The PEFR measured with MPFM was significantly related to the PEFR and $FEV_1$ measured with standard pneumotachygraph in normal and asthmatics(for PEFR, r = 0.92 ; p < 0.001 ; for $FEV_1$, r = 0.78 ; p < 0.001). The accuracy of MPFM was within 100(limits of accuracy recommeded by NAEP) in all the subjects or 22 normal, mean difference from standard pneumotachygraph being 16.5L/min(percentage of difference being 2.90%) or 10.6L/min(percentage of difference being 1.75%), respectively. According to the method proposed by Bland and Altman, the 95% limits of the distribution of differences between MPFM and standard pneumotachygraph after correction of PEFR using our regression equation were +38.2 and -71.5L/min in all the subjects or 20.49~+9.49L/min in 22 normal and was similar to the intraindividual agreements for 3 successive days in normal. There was no statistically significant difference of PEFR measured with MPFM and standard pneumotachygraph among three days(p > 0.05) and the coefficient of variation($2.4{\pm}1.2%$) of PEFR measured with MPFM was significantly lower than that($5.2{\pm}3.5%$) with standard pneumotachygraph in normal (p < 0.05). Conclusion : This results suggest that the MPFM was as accurate and reproducible as standard pneumotachygraph for monitoring of PEFR in the asthmatic subjects.

  • PDF

Effect of the Inhibition of PLA2 and PAF on the Neutrophilic Respiratory Burst and Apoptosis (호중구의 Respiratory Burst에 미치는 PLA2 및 PAF와 영향 : In vitro에서의 호중구의 산소기 생성 및 Apoptosis에 관한 연구)

  • Lee, Young-Man;Kim, Sang-Gyung;Park, Yoon-Yub
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.887-897
    • /
    • 2000
  • Background : Since the exact pathogenesis of sepsis-induced ARDS has not been elucidated, the mechanisms of enhanced neutrophilic respiratory burst were probed in endotoxin primed neutrophils associated with the roles of phospholipase A2(PLA2), platelet activating factor(PAF) and apoptosis. Methods : In isolated fresh human neutrophils, effects of the inhibition of PLA2 and PAF on the apoptosis were examined by the method of Annexin-FITC/dual PIflow cytometry. The roles of PLA2 and PAF on the neutrophilic respiratory burst were also examined by measuring oxidant generation in cytochrome-c reduction assay. Activities of the PLA2 and lysoPAF acetyltransferase (lysoPAF AT) of the neutrophils were determined to understand the effect of endotoxin on these enzymatic activities which may be related to the neutrophilic respiratory burst and apoptosis. In addition, the role roles of PLA2 and PAF in neutrophilic adhesion to bovine endothelial cells were examined in vitro by neutrophil adhesion assay. To investigate the effect of oxidants on pulmonary surfactant, cytochemical ultrastructural microscopy was performed. To inhibit PLA2 and PAF, non-specific PLA2 inhibitor mepacrine (100 nM) and WEB 2086 (100 nM) or ketotifen fumarate (10 ${\mu}g$/ml) were used respectively in all in vitro experimental sets. WEB 2086 is PAF receptor antagonist, and ketotifen fumarate is a lyso PAF AT inhibitor. Results: The mapacrine treatment, provided and the endotoxin (ETX) treatment, resulted in increased apoptosis of neutrophils (p<0.001) while treatments of WEB 2086 and ketotifen did not. The inhibition of PLA2 and PAF decreased (p<0.001) production of oxidants from PMA-stimulated neutrophils. While endotoxin increased the PLA2 activity of neutrophils (p<0.01), mepacrine supressed (p<0.001) the activity, provided after treatment of ETX. The lyso PAF actyltransferase activity (lyso PAF AT) increased (p<0.01) after treatment of ETX. In contrast, mepacrine, WEB 2086 and ketotifen showed a tendency of decreasing the activity after treatment of ETX. The treatment of ETX incresed (p<0.001) neutrophil adhesion to endothelial cells, which was reversed by inhibition of PLA2 and PAF (p<0.01). The binding of oxidants to pu1monary surfactant was identified histologically. Conclusions : The enhanced neutrophilic respiratory burst by ETX plays a pivotal role in the pathogenesis of ARDS in terms of oxidayive oxidative stress. Increased production of oxidants from neutrophils is mediated by the activations of PLA2 and lyso PAF AT.

  • PDF