• Title/Summary/Keyword: Measuring instrument

Search Result 851, Processing Time 0.031 seconds

Performance test of an electronic instrument transformer mounted an error compensating method for instrument transformer (변성기의 오차 보상 방법이 탑재된 전자식 변성기의 성능 평가)

  • Kang, Yong-Cheol;Park, Jong-Min;Jang, Sung-Il;Yun, Jae-Sung;Kim, Yong-Gyun;Lee, Byung-Sung;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.760-761
    • /
    • 2007
  • Instrument transformers provide the reproduction of the primary current or voltage to the measuring and protecting devices. The errors of an iron-cored transformer are caused by the difference between the primary and secondary currents due to the hysteresis characteristics of the iron-core. An error compensating algorithm for instrument transformer can improve the accuracy of conventional current and voltage transformers. This paper describes the performances of the electronic current and voltage transformers mounted an error compensating algorithm. The test results of the electronic transformers in Korea Electrotechnology Research Institute(KERI) are presented.

  • PDF

The Analysis for the Simulational Characteristics of the Electronic CT & PT using EMTP (EMTP를 이용한 전자식 CT, PT의 시뮬레이션 특성 분석)

  • Shin Jung Eun;Kim Jae Chul;Song Seung Youp;Kwon Young Mok;Kim On Suk;Choo Dong Wook
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.310-312
    • /
    • 2004
  • Generally, instrument transformer of the core type have been used for measuring current. Because instrument transformer has defects, electronic instrument was appeasred. This paper is introduced a basic concept and thoery of electronic instrument and described the the simulation of core type CT and no saturation CT. The evaluation of CT models implemented using EMTP(Electro Magnetic Transients Program) was carried out. The result of comparison both core type CT and no saturation CT are presented.

  • PDF

Validity and Reliability of the Nurses' Self-Concept Instrument (NSCI) for Registered Nurses in Long-term Care Hospitals (요양병원 간호사를 위한 전문직 자아개념 (Nurses' Self-Concept Instrument, NSCI) 도구의 타당도와 신뢰도)

  • Ryu, Jung Mi;Kim, Myoung Soo
    • Research in Community and Public Health Nursing
    • /
    • v.28 no.4
    • /
    • pp.366-374
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the validity and reliability of the Korean Version of the Nurses' Self-Concept Instrument (NSCI) geriatric hospital nurses in Korea. Methods: Bilingual nursing professionals performed translation and back-translation. Reliability and validity of the content and construction of the instrument were confirmed. Internal consistency reliability was determined. Construction and concurrent validity were verified using factor analysis and correlation coefficients. Results: The total 14 items for the Korean version of the Nurses' Self-Concept Instrument (NSCI) were retained through item analysis. In explanatory factor analysis, four subcategories were proposed with their names of each factor: 'Leadership', 'Staff relation', 'Knowledge', and 'Care'. The four factors accounted for 78.81% of the variances. The Cronbach's ${\alpha}$ regarding internal consistency were .77~.91 for the NSCI subscales. Correlation among four subcategories ranged .62~.84. Conclusion: The findings show that the Korean version of the Nurses' Self-Concept Instrument is reliable and valid for measuring professional Self-Concept of geriatric hospital nurses in Korea.

Evaluation of a Possibility of Estimation of Reaction Force of Surgical Robot Instrument using Sliding Perturbation Observer (슬라이딩 섭동 관측기를 이용한 수술용 로봇 인스트루먼트의 반력 추정 가능성 평가)

  • Yoon, Sung-Min;Lee, Min-Cheol;Kim, Chi-Yen;Kang, Byeong-Ho
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.1
    • /
    • pp.20-28
    • /
    • 2012
  • In spite of the difficulties and uncertain characteristic of cable driven method, surgical robot instrument has adopted it as driving mechanism for various reasons. To overcome the problem of cable system, previous research applied SMCSPO (sliding mode control with sliding perturbation observer) algorithm as robust controller to control the instrument and found that the value of SPO (sliding perturbation observer) followed force disturbance, reaction force loaded on the tip very similarly. Thus, this paper confirms that the perturbation observer is sufficient estimator which finds out the mount of loaded force on the surgical robot instrument. To prove the proposition, simulation using the similar model with an actual instrument and experimental evaluation are performed. The results show that it is possible to substitute SPO for sensors to measure the reaction force. This estimated reaction force will be used to realize haptic function by sending the reaction force to a master device for a surgeon. The results will contribute to create surgical benefit such as shortening the practice time of a surgeon and giving haptic information to surgeon by using it as haptic signal to protect an organ by making force boundary.

Development of a Questionnaire to Measure Family Stress among Married Working Women (가족스트레스 측정 도구 개발 - 기혼 여성근로자를 대상으로 -)

  • Kim Gwang-Suk;Cho Won-Jung
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.5
    • /
    • pp.761-769
    • /
    • 2006
  • Purpose: Even though a number of studies have suggested that appropriate measuring instruments of family stress for working women have to be developed, the validity and reliability of the instruments used have not been consistently examined. The purpose of the present study was to develop a sensitive instrument to measure family stress for married working women, and to test the validity and reliability of the instrument. Method: The items generated for this instrument were drawn from a comprehensive literature review Twenty four items were developed through evaluation by 10 experts and twenty one items were finally confirmed through item analysis. Psychometric testing was preformed and confirmed with a convenient sample of 240 women employed in the industrial sector. Result: Four factors evolved by factor analysis, which explained 50.5% of the total variance. The first factor 'Cooperation' explained 28.1%, 2nd factor 'Satisfaction with relationships' 10.6%, 3rd factor 'Democratic and comfortable environment' 6.3%, and 4th factor 'Disturbance of own living' 5.5%, Cronbach's coefficient of this instrument was 0.86. Conclusion: The study supports the validity and reliability of the instrument.

Development of an Instrument to Assess the Nursing Professional Pride (간호 전문직 자부심 측정도구 개발)

  • Jeon, JaeHee;Lee, EunHee;Kim, EunJoo
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.2
    • /
    • pp.228-241
    • /
    • 2020
  • Purpose: The purpose of this study was to develop an instrument to assess nursing professional pride. Methods: Fifty-six preliminary items were identified through literature review and focus group interview of nurses working in a hospital. Of these, 45 preliminary instruments were completed over 0.80 of content validity index. To verify the reliability and validity of the preliminary instrument, data were collected from 294 nurses. The data were analyzed using factor analysis and multidimensional scaling analysis. Results: From the factor analysis, 27 significant items were divided into 5 subscales. These subscales were as follows: feeling of vocation, role satisfaction, role of problem solver, self-achievement, and willingness to stay. The nursing professional pride also established criterion-related validity, discriminant validity, and group validity. Cronbach's α of the instrument was .92, and the subscales ranged from .74 to .85. Conclusion: The developed scale for nursing professional pride shows validity and reliability. The significance of this study is the development of an instrument capable of measuring nursing professional pride. To verify the relevance of this instrument, conducting comparative studies is suggested.

Ideal Topographic Simulations for Null Measurement Data

  • Su, Yan-Jen;Tung, Chi-Hong;Chang, Leh-Rong;Chen, Jin-Liang;Chang, Calvin
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.79-82
    • /
    • 2008
  • A method is described for ideally reconstructing the profile from a surface profiling measurement containing a reasonable amount of null measurement data. The proposed method can conjecture lost information and rectify irregular data that result due to bad measuring environments, signal transmission noise, or instrument-induced errors, The method adopts the concept of computer graphics and consists of several processing steps. First, a search for valid data in the neighborhood of the null data is performed. The valid data are then grouped and their contours are extracted. By analyzing these contours, a bounding box can be obtained and the general distribution of the entire area encompassing the valid and null data is determined Finally, an ideal surface model is overlaid onto the measurement results based on the bounding box, generating a complete reconstruction of the calculations, A surface-profiling task on a liquid crystal display photo spacer is used to verify the proposed method. The results are compared to those obtained through the use of a scanning electron microscope to demonstrate the accuracy of the proposed method.

Development and Validation of ESI iDART Instrument Measuring Organizational Values: An Empirical Study in Malaysia

  • OTHMAN, Abdul Kadir;HITAM, Mizan;ZAKARIA, Zuhaina;RAHMAD, Mohd Rafizi;MOHD SANUSI, Zuraidah
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.9 no.9
    • /
    • pp.157-166
    • /
    • 2022
  • The purpose of this paper is to explain the process of developing and validating the instrument to measure the university's organizational core values and sub-values known as ESI iDART. The three core values are excellence, synergy, and integrity, while the five sub-values comprise knowledge, discipline, trustworthiness, diligence, and responsibility that all staff should understand and practice. These values must be measured to examine the extent to which the staff has practiced them in their work life. With regard to methodology, the research instrument used in the study was developed using a focus group study involving 39 university staff from various departments and campuses. The instrument was later refined and validated by a group of experts from the university. In the main study, the instrument was distributed to all 17,969 university staff from all over the country. After one month, a total of 11,688 university staff participated in the survey indicating a 66% response rate. Using descriptive analysis, reliability analysis, and ANOVA, the results indicate that instrument is considered valid and reliable to be used. The major findings from the study show that organizational values increase over time. Some theoretical and managerial implications are also discussed.

System Requirement Review of Lunar Surface magnetometer on the CLPS program

  • Jin, Ho;Kim, Khan-Hyuk;Lee, Seongwhan;Lee, Hyojeong;Seon, Daerac;Jung, Byungwook;Jang, Yunho;Park, Hyeonhu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.40.1-40.1
    • /
    • 2020
  • The Korea Astronomy and Space Science Institute is participating as a South Korean partner in the Commercial Lunar Payload Services (CLPS)of NASA. In response, the Korea Astronomy and Space Science Institute is currently conducting basic research for the development of four candidate instrument payloads. The magnetic field instrument is one of them and it's scientific mission objective is the moon's surface magnetic field investigation. Therefore, the development requirement of the lunar surface magnetic field instrument were derived and the initial conceptual design was started. The magnetic field instrument has a 1.2 meter boom which has two three-axis fluxgate magnetometer sensors and one gyro sensor to get a attitude information of the boom. The concept of measuring the lunar surface magnetic field will carry out using multiple sensors by placing semiconductor type magnetic field sensors inside the electric box including boom mounted fluxgate sensors. In order to overcome the very short development period, we will use the KPLO (Korean Lunar Pathfinder Orbiter) magnetometer design and parts to improve reliabilities for this instrument. In this presentation, we introduce the instrument requirements and conceptual design for the Lunar surface magnetic field instruments.

  • PDF

Solar Radiation Measurement and Data Quality Management (태양자원 측정 및 데이터 품질관리)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.63.2-63.2
    • /
    • 2010
  • Solar radiation data are used in several forms and for a variety of purposes. The most detailed information we have is beam and diffuse solar radiation on a horizontal surface, by hours, which is useful in simulations of solar processes. Daily data are more often available and monthly total solar radiation on horizontal surface can be used in some process design methods. However, as performance is generally not linear with solar radiation, the use of average may lead to serious errors if non-linearities ara not taken into account. It is also possible to reduce radiation data to more manageable forms by statistical methods. The control of the quality of most measurements is relegated to the control of the measuring instruments and measuring processes themselves. An accurate measurement will usually result from the use of a high-quality instrument that has been accurately calibrated and is properly used by a qualified individual.

  • PDF