• Title/Summary/Keyword: Measuring device

Search Result 1,505, Processing Time 0.026 seconds

Measurement of the Underpipe Diameter by using Computer Vision (컴퓨터비전을 이용한 지중관로의 직경 측정)

  • Kim, Gibom;Cho, Sungman;Joo, Wonjong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.251-256
    • /
    • 2017
  • This study developed an image processing system for detecting damages on underground spiral PVC pipes. The detection method is simple-identifying damaged areas by measuring circularity along the pipeline. This uses the assumption that damage parts will not make a circular shape. Conventional devices check the circular shape of the pipe along the pipeline by measuring the angles between 6 spring-connected legs on the device. The conventional device, however, requires the insertion of 3 different wires (electrical, communication, and camera lines) along with a guide wire for pulling the device. The developed system presented here has simplified this system, requiring only a camera line while maintaining reasonable accuracy in damage detection.

Development of a Musculoskeletal Load Measuring Device for Construction Workers Based on Accelerometers and Gyro Sensors

  • Kim, Kyoon-Tai
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.6
    • /
    • pp.618-626
    • /
    • 2011
  • The characteristics of construction work cause excessive strain on specific body parts of the construction craft workers. However, there are few tools to mane an accurate measurement of the load on the musculoskeletal system, and the musculoskeletal disorders (MSDs) experienced by the workers have not been properly understood. So, there is an urgent need for development of a tool to measure the load on the musculoskeletal system. Therefore, this research aims to develop a musculoskeletal load measuring device for construction workers. In order to eliminate the noise and errors, an accelerometer, gyro sensors and the Kalman Filter are used in the device developed in this research.

Development of an Automatic Ophthalmological Outflow Facility Measuring Device (자동 안압 측정장치의 개발)

  • Kim, H.S.;Choi, Gi-S.;Lim, Y.A.;Ki, C.W.;Kim, W.K.;Hong, T.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.178-181
    • /
    • 1996
  • The Outflow facility of eye ball provides crucial informations in the diagnose of ophthalmological glaucoma. Tn this study an ophthalmic outflow facility measuring device is developed and experimentally tested. This system employs pressure sensors and linear positioning device to regulate solution reservoir height, the pressure of eye ball. The experimental result show that the system works well even in harsh environment so that it can be implemented in ophthalmic practice as well as in biomedical research.

  • PDF

Development of the Effective Clamping Force Measuring System for Spring Clamp (자동차용 스프링클램프 조임력 자동측정시스템의 개발)

  • O, Gi-Seok;Jo, Myeong-U;Seo, Tae-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.95-101
    • /
    • 2000
  • The purpose of this study is to develop an improved measuring system, which allows for effectively measure spring clamping forces. This system consists of eight or twelve measuring points in order to acquire the clamping force distribution of the whole range of spring clamp. Each measuring point consists of load cells equipped with 4 strain gauges. Using different bearings, we calibrate the roundness of the measuring points. For quality control and database construction, a software system is established. furthermore, uncertainty is calculated to validate the confidence of this system. Various experiments confirm the effectiveness of this measuring system.

  • PDF

Development of an Equilibrium Sensation Measuring System for Human Being (사람의 평형감각 측정시스템 개발)

  • Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.62-69
    • /
    • 2009
  • This paper describes the development of the new type equilibrium sensation measuring system for human with handicap in the equilibrium sensation. The medium and small hospital could not use the developed equilibrium sensation measuring system, because it is very high prices. Therefore, the new type system should be developed to measure the numerical value of the equilibrium sensation in human with handicap. In this paper, First, two 3-axis force/moment sensors which can measure force Fz, moments Mx and My simultaneous were designed and manufactured, second, the high speed measuring device which can acquire the output from two 3-axis force/moment sensors, third, the new type equilibrium sensation measuring system was developed, then the characteristic test of the developed equilibrium sensation measuring system carried out, it is confirmed that the system could measure the swing body of human with handicap.

Salinity and water level measuring device using fixed type buoyancy (고정식 부력을 이용한 염도 및 수위 측정 방식에 대한 연구)

  • Yang, Seung-Young;Byun, Kyung-Seok
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • To make an automated system for a salt field, it is necessary to measure the salinity and water level of the evaporation site. In this paper, a method to simultaneously measure the salinity and water level by measuring the buoyancy forces of two fixed buoyancy bodies is proposed. The proposed measurement method measures the buoyancy of the main part and reference part when the measuring device is immersed in the salty water, and simultaneously measures the salinity and water level through the sum and difference of the two buoyancy forces. Since there is no mechanical movement in the measurement of buoyancy, measurement errors and maintenance needs can be reduced in the mudy environment of salt field. By applying the proposed method, we developed a system that can simultaneously measure salinity and water level remotely at the evaporation site of a salt field. Through a measurement experiment using a reference salty water having various levels of salinity, the results of a salinity error of 0% and a water level error of 2mm were obtained, and the effectiveness of the proposed salinity and water level measuring device was verified. When an automated system is constructed using the developed salinity and water level measuring device, labor reduction, work environment improvement, and productivity improvement are expected.

Development of IoT-based PM2.5 Measuring Device (사물인터넷 기반 초미세먼지(PM2.5) 측정 장치 개발)

  • Loh, Byoung Gook;Choi, Gi Heung
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • An IoT-based particulate matter (PM2.5) sensing device (PSD) is developed. The PSD consists of a PM2.5 sensor, signal processing circuit, and wi-fi enabled-microprocessor along with temperature and humidity sensors. The PSD estimates PM2.5 density by measuring light scattered by PM2.5. To gauge performance of the PSD, PM2.5 density of open air was measured with the PSD and compared with that of the collocated-government-certified measuring station. Measurements were taken at a sampling frequency of 100 Hz and moving-averaged to remove measurement noise. When compared to the result of the measuring station, average percentile error of PM2.5 density from the PSD is found to be 31%. A correlation coefficient is found to be 0.72 which indicates a strong correlation. Instantaneous variation, however, may far exceed average errors, leading to a conclusion that the PSD is more suitable for estimating average trend of PM2.5 density variations than estimating instantaneous PM2.5 density.

Ultrasonic Bone Densitometer by Measuring the Speed of Sound (SOS를 이용한 초음파 골밀도 측정 장치)

  • Jung, Min-Sang;Hahn, Eun-Joo;Kim, Yeong-Sik
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.172-178
    • /
    • 2007
  • An ultrasonic bone densitometer has been developed by measuring speed of sound signal transmitted and received on the skin, not through the horizontal axis but through the vertical one in tissue. The SOS(speed of sound) method measuring the time difference between the ultrasound signals reflected from the both sides of surface of bone could produce more precise result compared with the BUA(broadband ultrasound attenuation) method measuring the frequency difference. Middle finger is selected to be the best measurement position in order to increase the accuracy, after due consideration that the thickness of flesh at the down part of thumb shows too much variation although the ratio of the receiving signal is higher than the other fingers. The measured value by using SOS method shows almost the same result as compared with the conventional DEXA method.

  • PDF

New Portable System for Measuring the Spasticity of Injury in Central Nervous System (중추신경계 손상에 의한 경직의 이동형 측정 시스템)

  • Song, Chul-Gyu;Seo, Jeong-Hwan;Han, Sang-Hyung;Kim, Keo-Sik;An, Yang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1180-1185
    • /
    • 2009
  • Spasticity is a velocity-dependent stretch reflex disorder of the body motor system developing after the injury of the central nervous system, in which certain muscles are continuously contracted involuntarily. Conventional methods such as the modified Ashworth scale, Spasm frequency scale, pendulum test and isokinetic dynamometer had some disadvantages: limitation in discriminating the increase of resistance, immovable and expensive device, not enough study parameters. Therefore, it is necessary to introduce clinically more useful instrument, which can produce objective data and are more convenient on spasticity measurement. Spasticity measuring methods were reviewed and a new measuring instrument was designed and introduced. The new measuring system is a portable spasticity-measurement system, which encompass various scopes of spasticity-related human signals such as electrophysiologic, kinematic and biomechanical data. Our device was designed in order to measure the joint angle, angular velocity, electromyographic signals and force. We suggest that this new system can diagnose the spasticity of the muscles, objectively.

Analysis of Master Dimensional Shape Error Rate According to Reverse Engineering Technique (역설계 방법에 의한 시편 치수 형상의 오차율 분석)

  • Jung, Hyun-Suk;Park, Su-Jung;Yoo, Joong-Hak
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.5
    • /
    • pp.393-399
    • /
    • 2016
  • In this study, an experiment was conducted using a 3D scanner, commonly used in reverse engineering techniques, and the newly introduced CT measuring machine. The hole, width, and angle of specimens having various shapes were designated, the error rates in dimensional modelling generated during scanning with each device were compared, and the models were printed using a 3D printer. A secondary comparative analysis of the two printed specimens was conducted; the causes of dimension errors that occur during the printing process after scanning with each device and the differences associated with variation in shape were also analyzed. Based on the analysis results, the featured shape for each scanning application method and issues to consider in reverse engineering were presented, and the use of the CT measuring machine was recommended as a method to minimize error rates in dimensions and ensure efficient reverse engineering.