• Title/Summary/Keyword: Measuring device

Search Result 1,510, Processing Time 0.029 seconds

A Design Experience of Propeller Open Water Testing Dynamometer (소형 프로펠러 단독시험기 설계)

  • J.S. Kim;M. Song;H. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.4
    • /
    • pp.48-54
    • /
    • 1995
  • A new propeller open water testing device is developed and tested in a tow tank. The devised dynamometer consists of a torque measuring part, a thrust measuring part and a driving motor with an RPM counter. Torque is designed to be measured directly from the torsion of the structure holding the motor by using strain gauges and, consequently, conventional slip ring is removed. Also, in order to make the device fit in relatively small model ships, the weight and the size of the whole integrated structure are reduced in various ways. The developed tester is proved to be easily utilized in small circulating water channel experiments and is believed to have provided us with essential information for future design of various types of conventional or object oriented force measuring device.

  • PDF

The Development of A Device to Measure the Ripeness and Internal Quality of Watermelons

  • Yshihide-Kouno;Toshihiro-Mizuno;Hiromu-Maeda;Akinaga, T-Akayoshi;Yoshihiro-Kohda
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1346-1353
    • /
    • 1993
  • Recently , it has been popular for family use to sell a watermelon by the piece such as a half or a quarter. Therefore, it has been necessary to detect and sort out hollow or overripened watermelons before they are shipped. Previously, inspection and rejection of hollow or overripened watermelons were carried out by skilled inspectors with their experience and intuition based on the traditional slapping method. In recent years many inspectors have became older and are going to retire. Thus automatic quality measuring devices have to be developed. There are many reports on the measurement of internal quality for watermelons with non-destructive methods. However, there is no online device to detect and measure both hollow and ripeness of watermelons until now. We have developed the model MWA-9002 online device to detect hollow and measuring the ripeness of watermelons by acoustic impulse. The developed of this devices has enables accurate distinction and rejection at the same level of the skilled inspectors, and also has saved labor. Nowadays nine automatic watermelon sorting and packing facilities applied this device have installed in Japan.

  • PDF

A Low-Power Design and Implementation of the Portable Device for Measuring Temperature and Humidity Based On Power Consumption Modeling (소비 전력 모델링에 입각한 휴대용 온습도 측정기의 저전력 설계 및 구현)

  • Lee, Chul-Ho;Hong, Youn-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1027-1035
    • /
    • 2014
  • The most important design factor for portable devices is power consumption. In this paper, in the early design stage of a mobile device which measures temperature and humidity a power consumption model will be proposed and then the overall power consumption will be estimated based on this model. We will verify previously the correctness of such estimated power consumption before implementation of the real device. That is our proposed design methodology based on power consumption model. An improved design method for efficiently reducing the current consumption in the idle mode is also presented. By implementing a real prototype of the mobile device for measuring temperature and humidity, the correctness of our proposed design methodology based on power consumption modeling will be verified.

Torque Profile Measuring and Sensibility Evaluation of a Haptic Device (햅틱 장치의 프로파일 측정 및 감성 평가)

  • Jun, Cha-Soo;Choo, Heon-Seong;Park, Se-Hyung;Kim, Lae-Hyun;Shin, Sang-Kyun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.3
    • /
    • pp.222-233
    • /
    • 2010
  • Developed in this research is a TP (tangible prototyping) system, which consists of two modules; (1) a virtual reality model to evaluate the functions and appearance of the product, and (2) a haptic device to emulate tactile and kinesthetic properties of mechanical dial knobs. As an example, a washing machine is modeled using a commercial CAD system and transformed in VRML and X3D formats. Some dynamic behaviors and kinematic characteristics are programmed using X3D script and Java. Various haptic behaviors of the dial are generated by modulating torque profile according to the rotation angle. A torque profile measuring system is developed to evaluate the behaviors of the haptic dial physically. Haptic sensibility evaluations are accomplished using the TP by semantic differential method.

A Study on the High-Accuracy Power Meter and Reliability Verification Plan (고정밀 전력미터의 개발과 신뢰성 확보 방안에 대한 연구)

  • Lee, Sanghun;LEE, Changhwa
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1046-1053
    • /
    • 2017
  • We propose a design method of high accuracy power measuring device and the method of securing the reliability of the measured data. As a design method for the development of the high accuracy power measuring device, the circuit was made by reflecting the high accuracy power measuring ICs and the CT (Current Transformer). To ensure the reliability of the power meter, we requested to the watt-hour meter certified testing organization to measure the error rate, and the error rate of active power based on the "Wattmeter Technical Standard(Revision notify 2014-283)" was measure, and the error rate was confirmed to be less than 0.1%.

The Study of reconstruction for 3D contact-measurement using TCP/IP communication (3차원 접촉식 측정기구의 네트웍을 통한 형상 복원에 관한 연구)

  • 고덕현;이순걸
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.3-7
    • /
    • 2000
  • The authors have realized reconstruction of 3D shape using contacting method with pins and TCP/IP communication. In this paper, the working principal of the mechanism is proposed and tested. A special sensor system is designed as 148 matrix form to measure 3D shape. When contact occurs between pin and the plate of the sensor matrix, the position information of pins is sent to computer and raised height data of the pin is obtained by counter which accumlates encoder signal. So, all datum which contain 3-dimensional coordinate, is transferred using TCP/IP communication. Finally, 3D shape is reconstructured by Web browser of remote computer. The measuring result shows that the proposed mechanism is reliable and promising as a remote measuring device through Internet.

  • PDF

Real-time High Resolution PM Monitoring in Seoul (서울지역 미세먼지의 실시간 고해상도 모니터링 방안)

  • Kang, Doo Soo;Bong, Choon Keun;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.67-78
    • /
    • 2019
  • Since existing measurement sites are required to construct a high-cost PM measuring device and a measuring site of a large area, there is a limit to the construction of a high-resolution measurement network. Therefore, it is necessary to develop a low-cost, high-performance PM measuring device (as an alternative technology) that can increase the resolution of PM measurement, and it is necessary to establish a base to provide real-time PM information for whole people. Therefore, in this study, the alternative technique (light scattering method) for achieving the above object was examined, performance evaluation was carried out, and it was verified that the light scattering method was usable. Various PM measurement results were compared and analyzed to find PM monitoring points and resolutions we would like to propose.

Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13) (상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정)

  • Kim, Ji-Hye;Baek, Tae-Hyeun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.2
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

Remote Impedance-based Loose Bolt Inspection Using a Radio-Frequency Active Sensing Node

  • Park, Seung-Hee;Yun, Chung-Bang;Inman, Daniel J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.217-223
    • /
    • 2007
  • This paper introduces an active sensing node using radio-frequency (RF) telemetry. This device has brought the traditional impedance-based structural health monitoring (SHM) technique to a new paradigm. The RF active sensing node consists of a miniaturized impedance measuring device (AD5933), a microcontroller (ATmega128L), and a radio frequency (RF) transmitter (XBee). A macro-fiber composite (MFC) patch interrogates a host structure by using a self-sensing technique of the miniaturized impedance measuring device. All the process including structural interrogation, data acquisition, signal processing, and damage diagnostic is being performed at the sensor location by the microcontroller. The RF transmitter is used to communicate the current status of the host structure. The feasibility of the proposed SHM strategy is verified through an experimental study inspecting loose bolts in a bolt-jointed aluminum structure.

The Development of Convenient RQ Measuring Device for Patients Real Time Monitoring (환자의 실시간 모니터링을 위한 간편한 RQ 측정기기의 개발)

  • Kim, Y.S.;Jeon, H.M.;Choi, S.W.;Shim, E.B.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1609-1612
    • /
    • 2008
  • RQ(Respiratory Quotient) value is obtained from the ratio of the consumed oxygen and the produced carbon dioxide during the patient's respiration. To investigate the efficacy of insulin and diagnosis the metabolic disorder in short time, the RQ value can be used as important parameter. The measurement of oxygen and carbon dioxide amounts is needed large chamber and complex sensors. But If the atmospheric oxygen and carbon dioxide concentrations do not change, the expiratory oxygen and carbon dioxide can be used to obtain RQ value. A convenient RQ measuring device has been developed by using two sensors for O2 and CO2. The estimation of RQ devices confirms that the RQ device can obtain accurate data by eliminating uncertain factor such as delay time and remaining gases.

  • PDF