• 제목/요약/키워드: Measuring device

검색결과 1,503건 처리시간 0.033초

A Study on Displacement Measurement Hardware of Retaining Walls based on Laser Sensor for Small and Medium-sized Urban Construction Sites

  • Kim, Jun-Sang;Kim, Jung-Yeol;Kim, Young-Suk
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.1250-1251
    • /
    • 2022
  • Measuring management is an important part of preventing the collapse of retaining walls in advance by evaluating their stability with a variety of measuring instruments. The current work of measuring management requires considerable human and material resources since measurement companies need to install measuring instruments at various places on the retaining wall and visit the construction site to collect measurement data and evaluate the stability of the retaining wall. It was investigated that the applicability of the current work of measuring management is poor at small and medium-sized urban construction sites(excavation depth<10m) where measuring management is not essential. Therefore, the purpose of this study is to develop a laser sensor-based hardware to support the wall displacement measurements and their control software applicable to small and medium-sized urban construction sites. The 2D lidar sensor, which is more economical than a 3D laser scanner, is applied as element technology. Additionally, the hardware is mounted on the corner strut of the retaining wall, and it collects point cloud data of the retaining wall by rotating the 2D lidar sensor 360° through a servo motor. Point cloud data collected from the hardware can be transmitted through Wi-Fi to a displacement analysis device (notebook). The hardware control software is designed to control the 2D lidar sensor and servo motor in the displacement analysis device by remote access. The process of analyzing the displacement of a retaining wall using the developed hardware and software is as follows: the construction site manager uses the displacement analysis device to 1)collect the initial point cloud data, and after a certain period 2)comparative point cloud data is collected, and 3)the distance between the initial point and comparison point cloud data is calculated in order. As a result of performing an indoor experiment, the analyses show that a displacement of approximately 15 mm can be identified. In the future, the integrated system of the hardware designed here, and the displacement analysis software to be developed can be applied to small and medium-sized urban construction sites through several field experiments. Therefore, effective management of the displacement of the retaining wall is possible in comparison with the current measuring management work in terms of ease of installation, dismantlement, displacement measurement, and economic feasibility.

  • PDF

3축 힘센서를 이용한 두 손가락 힘측정장치 개발 (Development of Force Measuring System using Three-axis Force Sensor for Measuring Two-finger Force)

  • 김현민;윤정원;신희석;김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.876-882
    • /
    • 2010
  • Stroke patients can't use their hands because of the paralysis their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by measuring the pressing force to be contacted with two fingers (thumb and first finger, thumb and middle finger, thumb and ring finger, thumb and little finger). But, at present, the grasping finger force of two-finger can't be accurately measured, because there is not a proper finger-force measuring system. Therefore, doctors can't correctly judge the rehabilitating extent. So, the finger-force measuring system which can measure the grasping force of two-finger must be developed. In this paper, the finger-force measuring system with a three-axis force sensor which can measure the pressing force was developed. The three-axis force sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP (Digital Signal Processing). Also, the grasping force test of men was performed using the developed finger-force measuring system, it was confirmed that the grasping forces of men were different according to grasping methods.

측면 에어 가이드 트랙을 이용한 새로운 운동마찰계수 측정 장치의 개발 (Development of New Measurement Device for the Coefficient of Kinetic Friction by Using Side Air-Guide Track)

  • 남형주
    • 공학교육연구
    • /
    • 제21권3호
    • /
    • pp.12-19
    • /
    • 2018
  • In this study, a new experimental device was developed for measurement of the coefficient of kinetic friction using a photo gate timer system which have advantages of easy and accurate detection of motion. This device, consisting of a side air-guide track and a side friction-free glider, forces a friction sample to move in a straight line without producing unnecessary friction. The new device is compared to two conventional measuring methods of friction for four different friction samples: one is using a camera system and the other is using a force sensor. It is demonstrated that the developed friction device in this study is easier to operate and produces the most accurate and the least deviating results among them. On the basis of these results, we propose that friction experiment using the new friction device is included in general physics experiment, so that engineering students should have a chance to get correct understanding of classical mechanics including friction phenomenon.

신발의 굽힘강성 측정 장비의 개발 (Development of Measurement Device for Bending Stiffness of Footwear)

  • 이종년
    • 한국산학기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.1078-1084
    • /
    • 2011
  • 스포츠화의 설계에서 신발 앞축 부분의 굽힘강성은 매우 중요한 설계인자이지만, 측정하기가 어렵다. 본 논문은 이러한 굽힘강성을 측정하는 장비를 소개한다. 장비는 알루미늄 프레임 구조와 AC 모터, 2개의 로드셀, 엔코더와 제어용 하드웨어로 구성되어있으며, 신발의 굽힘 모멘트를 측정하는 메카니즘을 소개하였다. 유용성을 입증하기 위하여, 신발의 소재와 디자인이 굽힘강성에 미치는 영향을 관찰하는데 사용되어 졌다. 실험을 위하여 신발 중창소재의 경도와 두께를 달리하여 완성신발 시편을 제작하였다. 이들 시편으로 굽힘실험을 수행하고, 최소자승법을 사용하여 굽힘강성을 구하였다. 실험결과 PU 중창으로 만든 신발이 PH 중창으로 만든 신발보다 굽힘강성이 높았으며, 중창의 두께가 중창의 경도보다 굽힘강성에 미치는 영향이 크다는 것을 알아낼 수 있었다. 따라서, 이러한 실험결과를 바탕으로, 본 측정장비는 유용한 실험결과를 도출할 수 있었으며, 이 장비를 통하여 측정된 신발의 굽힘강성은 신발 설계의 유용한 설계인자로 활용될 수 있다고 사료된다.

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

  • Kim, Sung-Chul
    • International Journal of Contents
    • /
    • 제9권1호
    • /
    • pp.38-41
    • /
    • 2013
  • The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

자동 형상제어용 측정롤의 특성에 관한 연구 (A Study on Characteristics of Measuring Roll for Automatic Flatness Control)

  • 김순경;전언찬;김중완;김문경;이승수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.551-555
    • /
    • 1996
  • The continuing demand for quality products requires better understanding and improved control of the production process. And, in recent year requirements for flatness control in strip rolling have become increasinglysevere because of the control for flatness of cold rolled strip is essential for further down stream processing. Also a speeds of rolling mills to meet productivity requirements puts a demanding requirement on the control of flatness of rolled strip. The demands on a total flatness control system therefore are a measuring and indication system consisting of a measuring roll that is robust, accurate, reliable and require a minimum of maintenance. The critical prt of any control system is the quality of the information being provided by the measurement instrument or device. It is therfore of utmost importance to have an accurate, repeatable and reliable measuring system. So, in this paper, The measuring roll for automatic flatness control system of contact type has been investigated.

  • PDF

3차원 좌표측정기의 기어측정능력평가를 위한 실험적 연구 (A Study on the Evaluation of the Gear Measurement Capability of a 3 Dimensional Coordinate Measuring Machine)

  • 심창건;변재현
    • 산업공학
    • /
    • 제12권2호
    • /
    • pp.180-192
    • /
    • 1999
  • A coordinate measuring machine (CMM) is a computer-controlled measuring device that uses a probe to obtain measurements on a manufactured part's surface. CMM's have been very popular over traditional hard gauges due to their flexibility, accuracy, and ease of automated inspection. This paper considers the use of a CMM for the inspection of gears. We compare the inspection capability of a CMM and that of a gear-specific measuring machine. The result of this paper may benefit gear manufacturing companies in their dimensional quality assurance activities, especially for special type gears and for large-scale gears which are not measurable by gear-specific measuring machines.

  • PDF

Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study

  • Lee, Jungwon;Pyo, Se-Wook;Cho, Hyun-Jae;An, Jung-Sub;Lee, Jae-Hyun;Koo, Ki-Tae;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • 제50권1호
    • /
    • pp.56-66
    • /
    • 2020
  • Purpose: A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Methods: Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six pork ribs and 216 bone-level implants measuring 10 mm in height were used. The implant beds were prepared using 1 of the following 3 drilling protocols: 10-mm drilling depth with a 3.5-mm-diameter twist drill, 5-mm drilling depth with a 4.0-mm-diameter twist drill, and 10-mm drilling depth with a 4.0-mm-diameter twist drill. The first 108 implants were external-connection implants 4.0 mm in diameter, while the other 108 implants were internal-connection implants 4.3 mm in diameter. The peak insertion torque (PIT) during implant placement, the stability values obtained with DCA and RFA devices after implant placement, and the peak removal torque (PRT) during implant removal were measured. Results: The intraclass correlation coefficients (ICCs) of the implant stability quotient (ISQ) results obtained using the RFA device at the medial, distal, ventral, and dorsal points were 0.997, 0.994, 0.994, and 0.998, respectively. The ICCs of the implant stability test (IST) results obtained using the DCA device at the corresponding locations were 0.972, 0.975, 0.974, and 0.976, respectively. Logarithmic relationships between PIT and IST, PIT and ISQ, PRT and IST, and PRT and ISQ were observed. The mean absolute difference between the ISQ and IST values on a Bland-Altman plot was -6.76 (-25.05 to 11.53, P<0.05). Conclusions: Within the limits of ex vivo studies, measurements made using the RFA and DCA devices were found to be correlated under a variety of stability conditions.

Ne-Ne 레이저의 간섭을 이용한 고정밀 리니어 스케일의 제작에 관한 연구

  • 전병욱;박두원;이명호;한응교
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1991년도 춘계학술대회 논문집
    • /
    • pp.176-194
    • /
    • 1991
  • A study on the Manufactiring of High-Precision Linear Scale by the Use of He-Ne Laser Interference Of late, along with the advancement of procision machining technology, the reauirement of super-precision measurement increases as time goes on, and the precision and accuracy of standard scale which is a basis of procision measurement has been cognized as a oriterion of industrial development in a nation. Up to now, mechanical and chemical methods have been widely employed to carve scale lines on linear scale, and it is impossible for the linear scale manufactured by means of those methods to guarantee the measurement with sub-micron level owing to errors attended with various problems. And the measuring length also bears errors subjected to the influence of surroundings condition, and shows inefficient circumstances in measurement on the ground of the complexity of measuring procedure as well as massive measuring apparatus. Hence in this paper, we described on technology by which we can carve scale lines thru optical method under the condition of laboratory by using rhcoherence of He-Ne two-mode stabilized laser and in turn, put it to practical use as linear scale for the measurment of lengrh. In this researchin the case of setting scale interval to 20 .mu. m, we employed super-precision scale-carving device associated by Ar larser and acoustic optical modulator in lieu of flsahing lamp scale-carving device, and we consequently obtained superior linear scales carved with precision and accuracy of .+-. 0.3 .mu. m.

원호검사법을 이용한 진원도 측정 방법의 개선에 관한 연구 (A Study on the Improvement of Circularity Measurement Using Circular Test Method)

  • 이승수;김민주;전언찬
    • 한국공작기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.24-29
    • /
    • 2002
  • A study for the circularity of machine tool is classified into two ways. One is to measure the circularity of machine tool by a existing measuring device. The other is to measure the circularity by remodeling the existing measuring device. We will improve on measurement of circularity using circular test method by a two-dimensional probe and a master ring for machining tools and investigate influence of trigger method, acceleration data sampling.