• Title/Summary/Keyword: Measuring device

Search Result 1,512, Processing Time 0.028 seconds

An Introduction of Myo Armband and Its Comparison with Motion Capture Systems

  • Cho, Junghun;Lee, Jang Hyung;Kim, Kwang Gi
    • Journal of Multimedia Information System
    • /
    • v.5 no.2
    • /
    • pp.115-120
    • /
    • 2018
  • Recently, ways for accurately measuring the three dimensional movements of hand are actively researched so as to utilize the measurement data for therapeutic and rehabilitation programs. This research paper aims to introduce a product called Myo Armband, a wearable device comprised of a 3-axis accelerometer, a 3 axis gyroscope, and electromyographic sensors. We compare Armband's performance with that of the Motion Capture System, which is known as a device for providing fairly accurate measurements for angular movements of objects. Dart throwing and wrist winding motions comprised movement scenarios. This paper also discusses one of Armband's advantages - portability, and suggests its potential as a substitute for previously used devices. Decent levels of measurement accuracy were obtained which were comparable to that of three dimensional measurement device.

Measurement of Gas Concentration and flow Rate Using Hot Wire (열선을 이용한 혼합기체의 농도와 유량의 측정)

  • Kim, Young-Han;Park, Jong-Jueng
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.5
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

A Study on LED Lighting Control according to Sleep Stage using PPG Sensor of Wearable Device

  • Song, Jeong Sang;Kim, Tae Yeun;Bae, Sang Hyun
    • Journal of Integrative Natural Science
    • /
    • v.12 no.1
    • /
    • pp.9-13
    • /
    • 2019
  • Recently, as the sleep disorder problem of modern people deepens, the interest towards quality of sleep is increasing. To increase the quality of modern people's sleep. This paper has suggested an LED lighting control system according to the sleep stage using PPG sensors of wearable devices. The pulse of the wrist radial artery was measured using a wearable device mounted with PPG sensor, which enables heart rate-measuring, and by using the point that heart rate lowers during stable sleep than non-sleeping, the LED lighting of indoors was controlled, which is the disturbing element when sleeping. For the performance evaluation, a 10-Fold cross analysis was conducted for performance evaluation, and a result of an average accuracy 87.02% was obtained as a result. Therefore, the LED lighting control system according to the sleep stage using a wearable device of this paper is expected to contribute to raise the quality of the user's life.

Design of 850 nm Near Infrared and Galvanic Current Based Eyeglass-Type Device for Periorbital Wrinkle Treatment and Verification of Treatment Performance through Image Analysis (850 nm 파장대 근적외선과 갈바닉 전류기반의 눈가 주름 치료기 개발 및 영상 분석을 통한 치료성능 검증)

  • Ahn, Sung Su;Kwon, Ki Jin
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.12
    • /
    • pp.1379-1386
    • /
    • 2018
  • In this paper, we proposed eyeglass type periorbital wrinkle treatment device for reducing and improving periorbital wrinkles using near infrared LED of 850nm wavelength and galvanic current. The proposed periorbital wrinkle treatment device is equipped with a control system based on F-PCB. It consists of eight near-infrared LEDs and four indicator LEDs for treatment of right and left periorbital wrinkles. The eyeglass frame is coated with conductive material, so galvanic current can flow to the skin of periorbital wrinkle contacted to it. One male adult in the mid-40s was allowed to use the device for 10 minutes every day for 4 weeks. After 4 weeks, image analysis using optical equipment for measuring wrinkles indicated that wrinkle indexes were reduced.

Design and implement of patch type wireless skin temperature measuring system (패치형 무선 피부 온도 측정 시스템의 설계 및 구현)

  • Woo, S.H.;Park, S.Y.;Din, Z. Mohy Ud;Won, C.H.;Lee, J.H.;Park, H.J.;Lee, J.W.;Hong, Y.G.;Suh, J.H.;Youm, Y.G.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.350-360
    • /
    • 2008
  • In every large hospital, nurses must perform simple repetitive tasks such as measuring body temperature. Such tedious work reduces nurses' motivation to provide quality medical care, which is an important element of the medical services provided by a hospital. If a device were available to measure body temperature, nurses could focus on the more important aspects of providing quality medical care to the patients. However, body temperature is generally measured from the throat, anus, tympanum or armpit, where it is difficult to affix a patch type device. In addition, general body temperature measuring points shows moving artifact error; therefore, it is not good point to continually measure the temperature. In this paper, a patch type skin temperature measuring system was developed. To appropriately measure the skin temperature, a thermal transducer was implemented with a thin (0.5 mm) temperature sensor. The system is small and thin ($H6.6{\sim}5.3{\times}L35{\times}W24\;mm$), and weighs only 5 g including a battery, case and circuit; therefore, it is small and light enough to function as a patch type device. Moreover, the system worked for 5 days. To investigate differences between the experimental and conventional thermometer, simple clinical experiments were performed with 17 volunteers, and the result showed some correlation between the implemented system and conventional thermometer (Correlation coefficient = 0.647, P<0.1).

The effect of plasma treatment to improve adhesion strength of parylene-C coated medical grade SUS304 (Parylene-C 코팅된 의료용 SUS304 소재의 결합력 향상을 위한 플라즈마 처리 효과)

  • Kim, Dong-Guk;Song, Tae-Ha;Jeong, Yong-Hoon;Kang, Kwan-Su;Yoon, Deok-kyu;Kim, Min-Uk;Woo, Young-Jae;Seo, Yo-Han;Kim, Kyung-Ah;Roh, Ji-hyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.390-397
    • /
    • 2022
  • Parylene-C which was mainly used for industries such as electronics, machinery and semiconductors has recently been in the spotlight in the medical field due to its properties such as corrosion resistance and biocompatibility. In this study we intend to derive a plan to improve the bonding strength of Parylene-C coating with the SUS304 base material for medical use which can be applied to various medical fields such as needles, micro needles and in vitro diagnostic device sensors. Through plasma pretreatment the bonding strength between Parylene-C and metal materials was improved. It was confirmed that the coated surface was hydrophobic by measuring the contact angle and the improvement of the surface roughness of the sample manufactured through CNC machining was confirmed by measuring the surface roughness with SEM. Through the above results, it is thought that it will be effective in increasing usability and reducing pain in patients by minimizing friction when inserting medical devices and in contact with skin. In addition it can be applied to various application fields such as human implantable stents and catheters, and is expected to improve the performance and lifespan of medical parts.

Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature (손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정)

  • Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.141-147
    • /
    • 2017
  • A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperature sensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuring pulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at $35^{\circ}C$ (the maximum wrist temperature), the device was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sensor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during temperature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect to thickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the compensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.

Development of Automatic Hole Position Measurement System using the CCD-camera (CCD-카메라를 이용한 홀 변위 자동측정시스템 개발)

  • 김병규;최재영;강희준;노영식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.127-130
    • /
    • 2004
  • For the quality control of the industrial products, an automatic hole measuring system has been developed. The measurement device allows X-Y movement due to contact forces between a hole and its own circular cone and the device is attached to an industrial robot. Its measurement accuracy is about 0.04mm. This movement of the plate is measured by two LVDT sensor system. But this system using the LVDT sensors is restricted by high cost and precision of measurement and correspondence of environment so particularly, a vision system with CCD-Camera is discussed in this paper for the above mentioned purpose. The device consists of two of two links jointed with hinge pins basically and, they guarantee free movement of the touch prove attached on the second link in the same plane. These links are returned to home position by the spring plungers automatically after each process for the next one. On the surface of the touch prove, it has a circular white mark for camera recognition. The system detect and notify the center coordinate of capture mark image through the image processing. Its measuring accuracy has been proved to be about $\pm$0.01mm through the repeated implementation over 200 times. This technique will shows the advantage of touch-indirect image capture idea using cone-shaped touch prove in various symmetrical shaped holes particulary, like tapped holes, chamfered holes, etc As a result, we attained our object in a view of the accuracy, economical efficiency, and functionality

  • PDF

A Study on the Test Method of RLC Parallel Circuits on the Device-Mounted Electronic Circuit Board (부품이 실장된 전자회로보드의 RLC 병렬회로 검사기법에 대한 연구)

  • Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.8
    • /
    • pp.475-481
    • /
    • 2005
  • In the existing ICT technique, the mounted electronic devices on the printed circuit board are tested whether the devices are good or not by comparing and measuring the value of the devices after separating the devices to be tested from around it based on the guarding method. But, in case that resistance, inductor and capacitor are configured as a parallel circuit on the circuit pattern, values for each device can not be measured because the total impedance value of the parallel circuit is measured. Accordingly, it is impossible to test whether the parallel circuit is good or not in case that the measured impedance value is within the tolerance error. Also, it is difficult to identify that which device among R, L and C of the parallel circuit is bad in case that the measured impedance value is out of the tolerance error. Accordingly, this paper proposes a test method which can enhance the quality and productivity by separating and measuring accurately R, L and C components from the RLC parallel circuits on the device-mounted printed circuit board. First, the RLC parallel circuit to be test is separated electrically from around it using three-terminal guarding technique. And then R, L and C values are computed based on the total impedance values and phase angles between voltage and current of the parallel circuit measured from two AC input signals with other frequency, Finally, the availability and accuracy of the proposed test method is verified by reviewing the simulation results.

Development and usability evaluation of EEG measurement device for detect the driver's drowsiness (운전자의 졸음지표 감지를 위한 뇌파측정 장치 개발 및 유용성 평가)

  • Park, Mun-kyu;Lee, Chung-heon;An, Young-jun;Ji, Hoon;Lee, Dong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.947-950
    • /
    • 2015
  • In the cause of car accidents in Korea, drowsy driving has shown that it is larger fctors than drunk driving. Therefore, in order to prevent drowsy driving accidents, drowsiness detection and warning system for drivers has recently become a very important issue. Furthermore, Many researches have been published that measuring alpha wave of EEG signals is the effective way in order to be aware of drowsiness of drivers. In this study, we have developed EEG measuring device that applies a signal processing algorithm using the LabView program for detecting drowsiness. According to results of drowsiness inducement experiments for small test subjects, it was able to detect the pattern of EEG, which means drowsy state based on the changing of power spectrum, counterpart of alpha wave. After all, Comparing to the results of drowsiness pattern between commercial equipments and developed device, we could confirm acquiring similar pattern to drowsiness pattern. With this results, the driver's drowsiness prevention system expect that it will be able to contribute to lowering the death rate caused by drowsy driving accidents.

  • PDF