• 제목/요약/키워드: Measuring Tube

검색결과 343건 처리시간 0.028초

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

  • Kim, Sung-Chul
    • International Journal of Contents
    • /
    • 제9권1호
    • /
    • pp.38-41
    • /
    • 2013
  • The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

소형 코리올리 질량 유량계의 개발 (Development of Small Size Coriolis Mass Flowmeter)

  • 임기원;지정근
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

전파흡수체의 전자파적 특성측정기법 연구 (A Study on Measuring Technique of Characteristics for Electromagnetic Wave of Microwave Absorbers)

  • 김동일;정세모;안영섭
    • 한국항해학회지
    • /
    • 제16권4호
    • /
    • pp.25-34
    • /
    • 1992
  • As a method of measure the absorbing characteristics of microwave absorber, the various microwave measuring method can be used fundamentally. There is, however, a big problem in measuring errors, since the wavelength of microwave such as used for radar is very short. Therefore, this research aimed to design and fabricate a converting adaptor of $20mm^{\phi}$ coaxial tube from a Type-N connector to $20mm^{\phi}$ coaxial tube and to use it for evaluating absorption characteristics of microwave absorber. Furthermore, the measurements of absorbing characteristics and material constants have been performed and review, which were carried out by using the coaxial tube and by using rectangular waveguide, respective. As a result, the validity of the proposed measuring method has been confirmed.

  • PDF

모세관내 과도유동현상을 이용한 비뉴턴유체의 점도측정 (Viscosity Measurement of Non-Newtonian Fluids Using the Transient Flow Phenomena in the Capillary Tube)

  • 조민태;서상호;유상신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.738-741
    • /
    • 2001
  • The purpose of the present study is to measure the viscosity of liquid in the capillary tube viscometer using the unsteady flow concept. The capillary tube viscometer is consisted of a small cylindrical reservoir, capillary tubes, and the mass flow rate measuring system interfaced with computer. Two capillary tubes with 1.152 and 3.002 mm I.D. are used to determine the diameter effects on the viscosity measurements. The instantaneous shear rate and gravitational driving force in the capillary tube are determined by measuring the mass flow rate through the capillary tube instantaneously. The measured viscosities of water and aqueous Separan solution are in good agreement with the reported experimental data.

  • PDF

전파흡수체의 전파흡수특성측정기법에 관한 연구 (A Study on Measuring Technique of Electromagnetic Wave Absorbing Characteristics of Microwave Absorbers)

  • 김동일;안영섭;정세모
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1992년도 정기총회 및 추계학술발표회
    • /
    • pp.2-29
    • /
    • 1992
  • According to the increase of occupation density of microwave frequency band on use microwave environments have been congested extensively. For shielding unnecessary electromagnetic wave of preventing the electromagnetic wave reflection a good conductor a low resistive material or a lossy material is mainly used. As a method to measure the absorbing characteristics of microwave absorber the fundamental microwave measuring method can be used. There is however a big problem in measuring errors since the wavelength of microwave is very short especially as in the case as microwave absorber for RADAR. Therefore this research aimed to a converting adaptor of 20mm${\Phi}$ coaxial tube from a Type-N connector to 20mm${\Phi}$ coaxial tube and to use it for designing microwave absorber and evaluating absorbing characteristics. Furthermore the measurements of absorbing characteristics and material constants have performed and reviewed which were carried out by using the coaxial tube in the short type and by using rectangular waveguide respectively As a result the validity of the measured values have been confirmed.

  • PDF

가스보일러 배기통 이탈에 의한 CO가스 누출확산 실험 및 수치해석 (EXPERIMENTAL AND COMPUTATIONAL PREDICTION OF CONCENTRATION OF CARBON MONOXIDE GAS RELEASED FROM EXHAUST TUBE OF GAS BOILER)

  • 강승규;최경석;윤준용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.172-175
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

자기 변형 기술을 이용한 액체 밀도 측정의 보정 기술 (Calibration Technique of Liquid Density Measurement using Magnetostriction Technology)

  • 서무교;홍영호;최인섭
    • 전자공학회논문지
    • /
    • 제51권8호
    • /
    • pp.178-184
    • /
    • 2014
  • 자기 변형 기술의 거리 측정을 응용하여, 중력과 액체 밀도에 대응하는 부력의 평형 위치를 측정하는 액체 밀도 센서를 개발하였다. 이 시스템의 정밀도 향상을 위해, 액체 밀도변화에 따른 밀도 센서의 이동거리 사이의 관계식을 유도하고, 이를 이용하여, 액체 밀도 센서의 2 점 보정 방법을 마련하였다. 제작된 액체 밀도 센서 시스템과 유도된 관계식을 사용하여 액체의 밀도들을 측정하였다. 측정된 결과들을 U-tube 진동주기 측정방식의 고 정밀 밀도 측정기(Oscillating U-tube density meter: 분해능 0.000001 g/cc)의 측정결과와 비교하였다. 그 결과 두 액체 밀도 측정 시스템간의 측정 편차가 0.001 g/cc 미만임을 확인하였다.

전파흡수체의 전파흡수특성 측정기법에 관한 연구 (A Study on Measuring Technique of Electromagnetic Wave Absorbing Characteristics of Microwave Absorbers)

  • 김동일;안영섭;정세모
    • 한국전자파학회지:전자파기술
    • /
    • 제4권1호
    • /
    • pp.10-19
    • /
    • 1993
  • 전파홉수체의 전파홉수능 측정방법은 기본적으로 다양한 마이크로파 측정법이 이용될 수 있지만, 레이다용전파홉수체의 경우, 전파의 주파수가높기 때문에 파장이 짧아서 측정오차가큰문제점이 있다. 따라서 본 연구에서는 전파홉수체의 전파홉수능을 실험적으로 간단히 측정할 수 있게 하기 위한 2 20rnrn¢동축관 생플흘더 및 Type-N connector로 부터 $20mm\phi$동축관으로의 변환Adaptor를 제작하여 전파홉수체의 설계 및 특성(전파홉수능) 평가에 사용할 수 있게 하였다. 또 구형도파관을 이용한 재료정수 측정법을 채용하여 시료의 형상동의 영향을 적게 받는 실측 방법에 관하여 검토하였다. 나아가서, 구형도파관을 이용한 재료정수 측정치를 반사감쇠량으로 환산한 전파홉수능파 동축관으로 측정한 전파흡수능의 주파수 특성을 구하여 거의 일치함을 밝히고 있다.

  • PDF

고고도환경을 고려한 SRM 압력계측배관에 관한 연구 (Study of a Pressure Tube for Measuring pressure of a Solid Rocket Motor at High Altitude Environment)

  • 이동원;이원복;고현석;길경섭
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.53-56
    • /
    • 2008
  • 일반적으로, 고체로켓모타에 대한 지상연소시험을 실시할 경우, 연소관 내부의 압력을 계측하기 위해 압력 계측용 배관에 기름을 채우고 그 끝에 압력센서를 연결하여 사용한다. 통상적으로 사용되어지는 이 방법은 지상연소시험을 실시할 경우에는 특별한 문제가 되지 않으나, 고고도 환경에서 점화되는 고체로켓모타의 압력계측은 배관 기름의 누출로 인한 점화성능 저하가 문제시된다. 이는 배관의 부착 위치가 통상적으로 전방 점화기 부위인 것에 기인한 것이며, 이러한 문제를 해결하기 위하여 본 논문에서는 기름을 사용하지 않는 압력배관을 어떻게 설계하고 검증하였는지에 대해 기술하도록 하겠다.

  • PDF

핀-관 열교환기에서의 접촉열저항 평가에 관한 연구 (A Study on the Thermal Contact Resistance Evaluation for Fin-Tube Heat Exchangers)

  • 정진;김창녕;윤백;길성호;양진승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.291-296
    • /
    • 2000
  • Usually the contact between fin collar and tube surface for fin-tube heat exchanger is secured by mechanical expansion of the tubes. The objective of the present study is to develop a method of measuring the thermal contact resistance between fin collar and tube surface for fin-tube heat exchanger. Also an experimental work has been performed to evaluate the thermal contact resistance, and a rigorous numerical analysis has been employed to calculate the contact resistance from the measured data. The experiments have been conducted fur the fin-tube heat exchangers with the tube of outer diameters 7 and 9.52 mm.

  • PDF