• 제목/요약/키워드: Measuring System

검색결과 6,778건 처리시간 0.038초

2차원 프로브에 의한 NC공작기계의 운동 정밀도 측정 -제2보 직선운동 정밀도 측정- (Measurement of Motion Accuracy by Two-dimensional Probe on NC Machine Tools -2nd Report, Measurement of the Linear Motion Accuracy-)

  • 전언찬;소산전중덕;제정신;각전윤일랑
    • 한국정밀공학회지
    • /
    • 제14권7호
    • /
    • pp.15-21
    • /
    • 1997
  • This paper presented a linear motion accuracy by using two-dimensional probe with the master block and the square for NC machine tools. This measuring system could be measured motion error due to numerical control system. The results of measurement and simulation for motion error were similar, and so, this system had enough accuracy to measure a linear motion accuracy for NC machine tools. The experimental results are as follows. 1. This measuring system could be measured motion error due to mumerical control system. 2. The results of measurement and simulation for motion error were similar. 3. This measuring system had enough accuracy to measure a linear motion accuracy for NC machine tools.

  • PDF

Implementing a Dielectric Recovery Strength Measuring System for Molded Case Circuit Breakers

  • Cho, Young-Maan;Rhee, Jae-ho;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1752-1758
    • /
    • 2018
  • In a low-voltage distribution system, the molded case circuit breaker (MCCB) is a widely used device to protect loads by interrupting over-current; however the hot gas generated from the arc discharge in the interrupting process depletes the dielectric recovery strength between electrodes and leads to re-ignition after current-zero. Even though the circuit breaker is ordinarily tripped and successfully interrupts the over-current, the re-ignition causes the over-current to flow to the load again, which carries over the failure interruption. Therefore, it is necessary to understand the dielectric recovery process and the dielectric recovery voltage of the MCCB. To determine these characteristics, a measuring system comprised of the experimental circuit and source is implemented to apply controllable recovery voltage and over-current. By changing the controllable recovery voltage, in this work, re-ignition is driven repeatedly to obtain the dielectric recovery voltage V-t curve, which is used to analyze the dielectric recovery strength of the MCCB. A measuring system and an evaluation technique for the dielectric recovery strength of the MCCB are described. By using this system and method, the measurement to find out the dielectric recovery characteristics after current-zero for ready-made products is done and it is confirmed that which internal structure of the MCCB affects the dielectric recovery characteristics.

전기철도의 전차선로 형상검측을 위한 광학기반 검측 장치 구현 (Implementation of Optical-based Measuring Instrument for Contact Wire Geometry in Electric Railway)

  • 박영;조용현;정호성;이기원;김형철;권삼영;박현준;김원하
    • 한국전기전자재료학회논문지
    • /
    • 제21권9호
    • /
    • pp.868-871
    • /
    • 2008
  • We propose an optical-based measuring instrument of catenary system in electric railway. This system was made to utilize line scan camera as inspecting system to measure the stagger and height of overhead contact wire in railway and composed with optical type source and FPGA-based image acquisition system with PCI slot. Vision acquisition software has been used for the application to programming interface for image acquisition, display, and storage with a frequency of sampling. To check the validity of our approach for the intended application, we monitored height and stagger in the overhead wire of a high-speed catenary system in Korea. The proposed optical-based measuring instrument to measure the contact wire geometry such as the hight and stagger shows promising on-field applications for online condition motoring. We expect that a new generation of real-time instruments with demanding various conditions motoring requirement in railway can be easily integrated into optical-based measuring instrument system.

복부초음파를 이용한 상완혈(上脘穴)-췌장 수직거리 측정시스템의 재현성 반복성 평가실험-A Pilot Study- (Gage R&R Study on Abdominal Sonography for Measuring Distance from Sangwan (CV13) to Pancreas - A Pilot Study -)

  • 남동현
    • 대한한의진단학회지
    • /
    • 제14권2호
    • /
    • pp.75-84
    • /
    • 2010
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from Sangwan (CV13) to pancreas. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from CV13 to pancreas with a ultrasound device three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from CV13 to pancreas was 6.29. So we concluded that repeatability and reproducibility of the ultrasound device system for measuring distance from CV13 to pancreas was acceptable.

정재파측정법과 Time Domain법에 의한 전파흡수능측정법의 비교 연구 (A Comparative Study on Measuring Methods of Absorption Characteristics for Electromagnetic Wave Using Standing Wave Measurement Method and Time Domain Method.)

  • 김동일;김상태;박지용;정세모
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1994년도 추계학술발표회
    • /
    • pp.79-90
    • /
    • 1994
  • The goal of this research is to get a measuring system for absorption characteristics of electromagnetic wave absorbers in ferrite type which are lat grid-type special type etc. It is however very difficult to measure the absorption characteristics as in low frequency as in 30 MHz, To solve the problem therefore we propose a standing wave method and a measurement method in time domain using parallel striplines construct the measuring system and measure the characteristics of ferrite microwave absorbers in grid type using the proposed measuring system.

  • PDF

냉각탑용 축류팬 형상 정밀도 측정 시스템 (Surface Profile Measuring System for Axial Fan of Cooling Towers)

  • 강재관;이광일
    • 한국정밀공학회지
    • /
    • 제22권4호
    • /
    • pp.151-158
    • /
    • 2005
  • An important component of a cooling tower is an axial fan, and there happens distortion in its shape which brings significant loss of efficiency. In this paper, a surface profile measuring system for large size axial fan of cooling towers is developed. A laser sensor is used as a measuring device and aluminum profiles and stepping motors are engaged into the system as frame structure and driving devices respectively. The measuring data are compared to the design data to compute the distortion of the axial fans. Two types of errors, axial and twist errors, are used to represent the precision of axial fan distortion. Genetic algorithm is used to solve the optimization problem during computing the precision. Results are displayed three dimensionally in a solid-modeler as well as 2-D drawings to help users find it with ease.

Standardization of Critical Temperature Measurement based on IEC International Standard

  • Lee, Kyu-Won;Kim, Kyu-Tae
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.123-127
    • /
    • 2003
  • For disseminating a ney IEC international standard of critical trmperature of NbTi,Nb$_3$Sn and Bi-2223 Composite Suterconductors, we develpted a measuring system and studied standardization of test method. The measuring system consisted of cryogenic reservoir, base plate, thermometer, voltmeter and current source. Various specimens of the Nbti, Nb$_3$Sn and Bi-2223 composite superconductors were tested using this system for measuring their critical temperatures. After measuring the resistance-temperature relation, the data were compensated with thermoelectric voltages for NbTi Nb$_3$Sn specimens. NbTi specimens showed 9.2 K ~ 9.5 K of transition temperature and Nb$_3$Sn specimen showed about 18 K. Bi-2223 specimens showed 104 K ~ 107 K of transition temperature.

Time Domain법에 의한 전파흡수체의 흡수능 측정법의 비교연구 (A Comparative Study on Measuring Methods of Absorption Characteristics for Electromagnetic Wave Absorber Using Time Domain Method)

  • 김동일;김상태;박지용;정세모
    • 한국전자파학회지:전자파기술
    • /
    • 제6권2호
    • /
    • pp.11-18
    • /
    • 1995
  • 본 연구는 평판형, 그리드형, 특수형상 등의 페라이트 전파흡스체의 흡수능 측정시스템을 구축하는 데에 목적이 있다. 그러나 30MHz와 같이 낮은 주파수에서 흡수능을 측정하느 것은 대단히 곤란 . 이와같은 문제를 해결하기 위하여 평행평판 스 라인을 사용하여 정재파측정법 및 시간영역법을 제안하였으며, 실제 측정시스템을 구성하요 제안한 측정볍으로 그리드형 페라이트 전자파흡수체의 특성을 측정. 평가하였다.특성을 측정. 평가하였다.

  • PDF

Measuring Performance in Egyptian Construction Firms Applying Quality Management Systems

  • Abd Elhamid, Manal S.;Ghareeb, Sahar.Sh.
    • Journal of Construction Engineering and Project Management
    • /
    • 제1권2호
    • /
    • pp.18-27
    • /
    • 2011
  • Egyptian construction firms (ECF) started recently to adopt quality management system (QMS) as a way to develop and improve their performance as previous studies have shown. However, considering all the firm's aspects in a competitive way is a crucial process for the ECF's culture. This research is trying to indicate the role of the QMS implementation in measuring performance (MP) through developing a model for measuring performance at the organizational level, and to explore its impact on the organizations that adopt QMS. This model is based on specific elements and their related indicators which have been derived from national approaches and models of MP. This model determines the performance level (PL) of the organization that is measured by means of a point system. Weights of the elements in the point system considered both the elements' importance in the international models and its real practice in the ECFs. This model has been validated using another questionnaire and the majority of surveyed experts agreed that the proposed model can be applied effectively.

송신 신호의 도달 시간차(TDOA)를 이용한 위치 측정 시스템의 구현 (Position Measuring System Design using Time Difference of Arrival)

  • 김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.394-397
    • /
    • 2001
  • There are several methods of measuring position. For example GPS, AOA, TDOA and using radio camera. In this Paper I used TDOA method in position measuring system. TDOA method uses arrival time difference. In position measuring system, three transfers which is placed in different position transfer signal to receiver in fixed time interval and receiver records arrival time of signal. Because receiver knows idle signal's arrival time, receiver can calculate the difference of the signal's arrival time between idle and real. When we obtain time difference we can know the receiver position by Newton Raphson method.

  • PDF