• Title/Summary/Keyword: Measuring Sensor

Search Result 1,966, Processing Time 0.037 seconds

Development of the Sensor for Measuring the Electric Fields (전계 측정용 센서의 개발)

  • 백용현;이복희;안창환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.630-637
    • /
    • 1991
  • For the measurement of time-varying electric fields and related quantities, a field sensor should be sensitive to the field to be measured, and also designed having an accurate transfer function. In this paper, a theoretical model which adequately describes the operation principle and design of the sensor is presented. A calibration and/or correction technique of the sensor is also studied which enables a precise determination of the response of the sensor to an electric field. As a result, the developed electric field sensor and measuring system are known to be accurate within a bandwidth from a few Hz to 200 MHz. It is found that the sensor can be used directly in the measurement of very fast transient voltages and time-varying electric fields occurring during disconnector operations in a gas-insulated substation. It may be useful also for the study on the electromagnetic environmental parameters.

Development of a Non-contacting Capacitive Sensor for Measurement of ${\mu}{\textrm}{m}$-order Displacements (마이크로미터 변위 측정을 위한 비접촉식 전기용량 센서 개발)

  • 김한준;이래덕;강전홍;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.768-771
    • /
    • 2001
  • Non-contacting capacitive sensor, based on principle of the cross capacitor, for measuring of $\mu\textrm{m}$-order displacements have been fabricated and characterized. To overcome disadvantages of the existed capacitive sensors of parallel type with 2-electrodes and 3-electrodes, the developed new sensor was designed to have 4-electrodes, two of them used high and low electrode the other two used as guard electrodes, on a sapphire plate with diameter 17 mm and thickness 0.7 mm, and are symmetrically situated with a constant gap of 0.2 mm between the electrodes. This sensor can be used for measuring the distance between sensor and target not only the metallic but also non-metallic target without ground connection.

  • PDF

Experimental Study on a Micro Flow Sensor (미소 유량 센서에 관한 실험적 연구)

  • Kim, Tae-Hoon;Kim, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1783-1788
    • /
    • 2004
  • In the present paper, a micro flow sensor, which can be used at bio-delivery systems and micro heat pumps, is developed. For this, the micro flow sensor is integrated on a quartz wafer ($SiO_2$) and is manufactured by simple and convenient microfabrication processes. The micro flow sensor aims for measuring mass flow rates in the low range of about $0{\sim}20$ SCCM. The micro flow sensor is composed of temperature sensors, a heater, and a flow microchannel. The temperature sensors and the heater are manufactured by the sputtering processes in this study. In the microfabrication processes, stainless steel masks with different patterns are used to deposit alumel and chromel for temperature sensors and nichrome for the heater on the quartz wafer. The microchannel is made of Polydimethylsiloxane(PDMS) easily. A deposited quartz wafer is bonded to the PDMS microchannel by using the air plasma. Finally, we confirmed the good operation of the present micro flow sensor by measuring flow rate.

  • PDF

A Study on the Data Transmission of Multiple Sensor Using Code Division Multiple Access (코드분할다중접속을 이용한 다중센서 데이터 전송에 관한 연구)

  • Mun, Se-Sang;Park, Woo-Il;Kim, Woo-Shik;Cho, Hyang-Duck
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1093-1099
    • /
    • 2006
  • In general, a measuring instrument of sound noise use only one wired channel by one sensor. Therefor the measuring instrument use wired cables as the number of channels are provided by instrument. In a point of observed target it needs data from multiple sensors and In case of measured point is a large numbers the environment of constitution would be complicated because that is in need of channel and cable. So we need the method that can improve the existing transmission channel and cable environment even the measured point is increased. If we use the Code Division Multiple Access(CDMA) we transmit a large numbers of sensor data by using a common transmission channel. We present the method that transmits data of multiple sensor to wireless by using CDMA. This method can simplify the measurement environment dramatically when collecting data by using multiple sensor. We expect this study to contribute the part of multiple access technology and relation technologies on the measuring environment.

Development of PSD Sensor Based Distance Measuring System Using Linearizing Function of Voltage-Distance Conversion (선형화 전압-거리 변환함수를 이용한 PSD 센서기반 거리계측시스템의 개발)

  • Kim Yu-Chan;Ryoo Young-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.6
    • /
    • pp.668-672
    • /
    • 2005
  • In this paper, a distance measuring system using a PSD sensor in proposed, which in suitable for low-cost localization sensor of a mobile robot. Because the distance-voltage output of PSD sensor has a non-linear property, the linearizing function is proposed through the experimental characteristics of the sensor. And the characteristics are tested and the distance-voltage data are measured in various colors and materials of object. The parameters of the proposed function are extracted by using the measured data. Finally, the performance and the accuracy of the developed system are verified according to the comparison of the distance by the proposed function with the real distance.

A Study on the data transmission of multiple sensor using code division multiple access (코드분할다중접속을 이용한 다중센서 데이터 전송에 관한 연구)

  • Cho, Hyang-Duck;Mun, Se-Sang;Park, Woo-Il;Kim, Woo-Shik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.133-137
    • /
    • 2006
  • In general, a measuring instrument of sound noise use only one wired channel by one sensor. Therefor the measuring instrument use wired cables as the number of channels are provided by instrument. In a point of observed target it needs data from multiple sensors and In case of measured point is a large numbers the environment of constitution would be complicated because that is in need of channel and cable. So we need the method that can improve the existing transmission channel and cable environment even the measured point is increased. If we use the Code Division Multiple Access(CDMA) we transmit a large numbers of sensor data by using a common transmission channel. We present the method that transmits data of multiple sensor to wireless by using CDMA. This method can simplify the measurement environment dramatically when collecting data by using multiple sensor. We expect this study to contribute the part of multiple access technology and relation technologies on the measuring environment.

  • PDF

Design of a Two-Axis Force Sensor for Measuring Arm Force of an Upper-Limb Rehabilitation Robot (상지재활로봇의 팔힘측정용 2축 힘센서 설계)

  • Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.137-143
    • /
    • 2015
  • This paper describes the design of a two-axis force sensor with two step plate beams for measuring forces in an upper-limb rehabilitation robot. The two-axis force sensor is composed of a Fz force sensor and a Ty torque sensor. The Fz force sensor measures the force applied to a patient's arm pushed by a rehabilitation robot and the force of patient's arm. The Ty torque sensor measures the torque generated by a patient's arm motion in an emergency. The structure of sensor is composed of a force transmitting block, two step plate beams and two fixture blocks. The two-axis force sensor was designed using FEM (Finite Element Method), and manufactured using strain-gages. The characteristics test of the two-axis force sensor was carried out. as a test results, the interference error of the two-axis force sensor was less than 1.24%, the repeatability error of each sensor was less than 0.03%, and the non-linearity was less than 0.02%.

Experimental Study on the Rotational Speed Measuring Condition of a Gasoline Fuel Pump for a Small-Size Engine (소형엔진용 가솔린 연료펌프의 회전수 측정 조건에 대한 실험적 연구)

  • Lee, Jun-Sun;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3184-3189
    • /
    • 2010
  • To develop gasoline engine fuel pump, it is needed to measure the rotational speed of the pump. In general, because gasoline fuel pump is submerged in the fuel tank, it is difficult to measure the rotational speed directly. Currently, there are two popular methods measuring the rotational speed. One of them is using a piezoelectric accelerometer, and the other is using a current sensor. Originally, a piezoelectric accelerometer had been applied to measure the frequency of the motor vibration. A current sensor is measuring current frequency of the commutator slot. In this study, both the piezoelectric accelerometer and the current sensor have been applied on the fuel pump to calculate the rotational speed at the same time. As a result, the current sensor delivered highly accurate rotational speed information compared with that of the piezoelectric accelerometer. Especially, low rotational speed region, the current sensor shows very robust measuring characteristics. To measure the rotational speed within 1% error, the piezoelectric accelerometer needs to be set with less then 0.5Hz datum storage interval, and the current sensor needs to be set with less then 2.0Hz datum storage interval.

Development of ROM Measurement Device capable of IoT-based Real-time Monitoring for Rehabilitation Patients (재활환자를 위한 IoT 기반의 실시간 모니터링이 가능한 ROM 측정 장치 개발)

  • Kang, Min-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.111-116
    • /
    • 2018
  • In this thesis, the range of motion of the joint was measured using a flexible sensor without using a goniometer, and the measured values were transferred to a smart device. Current range of joint motion measurement is measured by a person using a goniometer. Since the method of measuring by a person is different according to the measuring method and position of the measuring person, it is difficult to make consistent measurement, and an error may occur. The sensor for measurement is a flexible sensor that measures the resistance value that changes according to the movement of the joint. The sensed value can be transmitted to the smart device wirelessly through the ROM sensor node. Also, the sensed analog values were converted to digital values using an ADC. The converted value can be transmitted to the smart device wirelessly through the sensor node. The developed ROM measuring device can perform more consistent measurement than the measurement using general articulator and real time monitoring by interlocking with smart device, so that rapid diagnosis according to the movement of the joint can help the patient's rapid treatment and rehabilitation medical advancement will be.