• Title/Summary/Keyword: Measuring Report

Search Result 445, Processing Time 0.026 seconds

Strain relaxed Co nanocrystals formation from thin films on sapphire substrate induced by nano-second laser irradiation

  • Seo, Ok-Gyun;Gang, Deok-Ho;Son, Jun-Gon;Choe, Jeong-Won;Ha, Seong-Su;Kim, Seon-Min;Gang, Hyeon-Cheol;No, Do-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.145.2-145.2
    • /
    • 2016
  • We report the phase transformation of Co thin films on a sapphire substrate induced by laser irradiation. As grown Co films were initially strained and tetragonally distorted. With low power laser irradiation, the surface was ruptured and irregular holes were formed. As the laser power was increased, the films changed into round shape Co nanocrystals with well-defined 6-fold structure. By measuring the XRD of Co nanostructure as a function of laser energy densities, we found that the change of morphological shapes from films to nanocrystals was accompanied with decrease of the tetragonal distortion as well as strain relaxation. By measuring the size distribution of nanocrystals as a function of film thickness, the average diameter is proportional to 1.7 power of the film thickness which was consistent with the prediction of thin film hydrodynamic (TFT) dwetting theory. Finally, we fabricated the formation of size controlling nanocrystals on the sapphire substrate without strain.

  • PDF

Measuring AGN Core-shift Effect by Extended KVN with Global Baselines

  • Jung, Taehyun;Dodson, Richard;Han, Seog-Tae;Byun, Do-Young;Sohn, Bong Won;Rioja, Maria J.;Honma, Mareki;Stevens, Jamie;de Vincente, Pablo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.43.3-44
    • /
    • 2015
  • Very Long Baseline Interferometry (VLBI) at millimeter wavelengths results in the highest angular resolutions achieved in astronomy and has a unique access to emission regions that are inaccessible with any other approach or at longer wavelengths. The simultaneous multi-frequency VLBI system in the Korean VLBI Network (KVN) is considered one of the most effective systems for compensating the atmospheric phase fluctuations, which is particularly bothersome at mm-VLBI. We have been demonstrating its performance and uniqueness at mm-VLBI observations. As a results, international VLBI partners from Japan, China, Australia and EU have expressed their interest on the KVN style simultaneous multi-frequency system. In this talk, we will report the activities for extending the simultaneous multi-frequency system to global VLBI network and introduce its science driver, measuring AGN core-shift effects.

  • PDF

Development and Application of TACT Management System (TACT 공정관리 시스템 개발 및 적용 사례)

  • Suh Sang-Wook;Kim Jae-Ho;Kim Sun-Kuk;Kim Chang-Duk;Lee Hyun-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.145-154
    • /
    • 2003
  • The change in environment of construction industry and the advancement of information technology require the improvement of construction project efficiency. However, construction industry still lacks performance-measuring tools that are the requirements of efficient project management system. In case of the schedule management system, schedule is usually being managed by result-oriented measurements such as completion time, spent cost, and progress rate, which are not good enough to control the overall continuity of work-flow. This research aimed to systemize the overall construction process and to develop the indicators for measuring performance of TACT activities during finishing work period that can contribute to the systemization of TACT management.

Development and Application of TACT Management System (TACT 공정관리 시스템 개발 및 적용 사례)

  • Kim Jea-Ho;Suh Sang-Wook;Kim Sun-Kuk;Kim Chang-Duk;Lee Hyun-Soo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.126-134
    • /
    • 2003
  • The change in environment of construction industry and the advancement of information technology require the improvement of construction project efficiency. However, construction industry still lacks performance-measuring tools that are the requirements of efficient project management system. In case of the schedule management system, schedule is usually being managed by result-oriented measurements such as completion time, spent cost, and progress rate, which are not good enough to control the overall continuity of work-flow. This research aimed to systemize the overall construction process and to develop the indicators for measuring performance of TACT activities during finishing work period that can contribute to the systemization of TACT management.

  • PDF

Development of UHF RFID Ceramic Antenna Using HFSS (HFSS를 이용한 UHF RFID 세라믹 안테나 개발)

  • Hwang, Gi-Hyun;Cha, Kyung-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.1
    • /
    • pp.193-198
    • /
    • 2009
  • In this paper, we report the design of UHF RFID ceramic antenna using HFSS, one of the widely used RFID design tools. Of the developed antenna system, we analyze its Return Loss using HFSS and its characteristics using Smith Chart methodology. We built the ceramic antenna system based on the HFSS design, and analyzed its performance by measuring the impedence matching and gains using Network Analyzer. We attach the developed prototype to UHF RFID portable terminal, and performed distance measuring for five widely used types of RFID tags to verify the performance of our proposed antenna system.

Ganglion of the Flexor Tendon Sheath between A1 Pulley and A2 Pulley

  • Jung, Kyu Hwa;Choi, Hwan Jun;Kim, Jun Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.23 no.1
    • /
    • pp.29-32
    • /
    • 2014
  • Few articles have been written about the flexor tendon sheath ganglion in the finger, especially, between A1 pulley and A2 pulley. We report on rare cases of flexor tendon sheath ganglion with one symptomatic and two asymptomatic. All masses were evaluated using real-time ultrasonography and well-defined anechoic cystic lesions with posterior enhancement were observed. A 17-year-old female had a small mass at the 4th metacarpophalageal joint of her right hand, with pain and triggering. The patient underwent simple excision and a ganglion measuring $1.0{\times}0.8$ cm in size was derived from Camper's chiasm, between A1 pulley and A2 pulley. In two asymptomatic cases, ganglia measuring less than 0.5 cm in size observed. Based on our experience, real-time ultrasonography would be an excellent diagnostic modality in determining the treatment method in flexor tendon sheath ganglia, and surgical excision is recommended in symptomatic, especially triggering patients.

MEASURING THE CORE SHIFT EFFECT IN AGN JETS WITH THE EXTENDED KOREAN VLBI NETWORK

  • JUNG, TAEHYUN;DODSON, RICHARD;HAN, SEOG-TAE;RIOJA, MARIA J.;BYUN, DO-YOUNG;HONMA, MAREKI;STEVENS, JAMIE;VICENTE, PABLO DE;SOHN, BONG WON
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.5
    • /
    • pp.277-284
    • /
    • 2015
  • We present our efforts for extending the simultaneous multi-frequency receiver system of the Korean Very Long Baseline Interferometry (VLBI) Network (KVN) to global baselines in order to measure the frequency-dependent position shifts in Active Galactic Nuclei (AGN) jets, the so called core shift effect, with an unprecedented accuracy (a few micro-arcseconds). Millimeter VLBI observations with simultaneous multi-frequency receiver systems, like those of the KVN, enable us to explore the innermost regions of AGN and high precision astrometry. Such a system is capable of locating the frequency dependent opacity changes accurately. We have conducted the feasibility test-observations with the interested partners by implementing the KVN-compatible systems. Here we describe the science case for measuring the core shift effect in the AGN jet and report progress and future plans on extending the simultaneous multi-frequency system to global baselines.

Development of a Measurement of Intellectual Capital for Hospital Nursing Organizations (병원 간호조직의 지적자본 측정도구 개발)

  • Kim, Eun-A;Jang, Keum-Seong
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.1
    • /
    • pp.129-140
    • /
    • 2011
  • Purpose: This study was done to develop an instrument for measuring intellectual capital and assess its validity and reliability in identifying the components, human capital, structure capital and customer capital of intellectual capital in hospital nursing organizations. Methods: The participants were 950 regular clinical nurses who had worked for over 13 months in 7 medical hospitals including 4 national university hospitals and 3 private university hospitals. The data were collected through a questionnaire survey done from July 2 to August 25, 2009. Data from 906 nurses were used for the final analysis. Data were analyzed using descriptive statistics, Cronbach's alpha coefficients, item analysis, factor analysis (principal component analysis, Varimax rotation) with the SPSS $PC^+$ 17.0 for Windows program. Results: Developing the instrument for measuring intellectual capital in hospital nursing organizations involved a literature review, development of preliminary items, and verification of validity and reliability. The final instrument was in a self-report form on a 5-point Likert scale. There were 29 items on human capital (5 domains), 21 items on customer capital (4 domains), 26 items on structure capital (4 domains). Conclusion: The results of this study may be useful to assess the levels of intellectual capital of hospital nursing organizations.

Comparison of Chord method with Surveying in Track irregularity Measurement (측량과 현방식 궤도틀림 측정 비교)

  • Lee, Jee-Ha;Lee, Sang-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1647-1652
    • /
    • 2008
  • Track geometry consists of tangent and curved lines, which caused undesirable changes in initial track geometry by traffic loads. The bigger the changes are, the worse the riding comfort and running stability of train. This is so-called track irregularity and is the most important quality parameters of ballasted track. To be able to objectively assess track irregularity, track geometry should be able to be measured. Practically, railway companies use moving chord method, this method determine versine values via a chord. The versine is the vertical distance to curve measured in the middle of the chord. This type of method measures only versine of track irregularity curve by transfer function from specific property of measuring tool. In this report, review the characteristics of two types of measuring tools by comparing the measurements. The one is GRP-1000 system, optical surveying system with Total station and lazar prism trolly. This calculates track geometry by surveying absolute coordinates of two points each on both rail heads. The other is Trackmaster, measures versine with 2m of chord length.

  • PDF

Quantity of Ascorbic Acid in the Parts of Vegetable and Its variation by Cooking Method (상용채소의 부위에 따른 환원형 Ascorbic acid량과 조리방법에 따른 C량의 변화)

  • 강신주
    • Journal of the Korean Home Economics Association
    • /
    • v.4 no.1
    • /
    • pp.589-594
    • /
    • 1963
  • Ascorbic acid has a strong power to reduce other materials, so by using this reducing power we can analise many materials quantitatively. Dihydro-ascorbic acid is quantitatively changed into ascorbic acid under a certain condition, if reduced by hydrogen-sulfide. Dihydro-ascorbic acid also has physiolosical effect, but less effect than ascorbic acid. The effect of dihydro-ascorbic acid is regarded as a half of that of ascorbic acid. Among the analytical methods applying this theory the method using 2.6 dichlorophenol indophenol what called the method of Indophenol is used most widely; so does Hydrazine-method. But comparing these two methods the former shows a little higher rate in analytical value. Vegetable are vital sources for vitamin C. According to the report of the commitee of FAO Korean branch the amount of daily per head average intake of vitamin C is about 70mg in raw materials. Since vitamin C is easily affected by heating or oxidation in Cooking the loss is not a little. Consequntly it is regarded that the actual amount of intake will be much less than basic amount. It is therefore very important to find out that how much percent of the loss there will be in case of cooking, in order to dicide the actual amount of in take as proper nutrition for a person. Therefore this paper intended to give some help in setting a standard amount of V.C intake, by measuring the change of the V.C amount using the general cooking method and by measuring amount of V.C contained in the part of vegetable, used in Korea abundantly.

  • PDF