• 제목/요약/키워드: Measurement sensor

검색결과 3,929건 처리시간 0.03초

다중 렌즈 모듈의 기울기 측정 : 이론 및 응용 (Tilt Measurement of Lens Module with Multiple Lenses : Algorithm and Application)

  • 이승희;박종현
    • 대한기계학회논문집A
    • /
    • 제31권3호
    • /
    • pp.395-402
    • /
    • 2007
  • This paper considers about the tilt measurement of lens module with multiple lenses. The tilt between lenses in lens module and barrel or between image sensor and barrel can be measured precisely with the proposed algorithm. The magnitude and direction of the tilt vector of lens and image sensor can be measured from the best focal surface. The selecting and setting of image sensor, test chart, image sensor centering to lens module, axis align, focus measure method are also explained to get highly precise tilt results. The proposed algorithm is verified with the lens module inspection system we developed, and the experimental results show that the tilt measure proposed in this paper is robust and precise. With the proposed tilt measurement algorithm, the tilt of an image sensor and any other lens which intermediates light can be measured.

집중 소자를 이용한 표면 탄성파 장치 기반의 용량 성 센서 보정 및 이를 이용한 초정밀 간극 측정 (Calibration of SAW Based Capacitive Sensor Using Lumped Component and High Precision Gap Measurement)

  • 김재근;고병한;박영필;박노철
    • 정보저장시스템학회논문집
    • /
    • 제8권1호
    • /
    • pp.16-21
    • /
    • 2012
  • SAW device is widely used as filters, sensors, actuators in various technologies. And capacitive sensor is tremendously used to measure pressure, gap, etc. The application of SAW device as signal conditioner of capacitive sensor reduces noise level and enables high precision measurement. The response increase of SAW based capacitive sensor is produced just before the two capacitive electrode contacts by the existence of parasitic resistance of capacitive electrode. In this paper, we analyze the effects of parasitic resistance and propose the calibrating method using lumped component and execute the high precision gap measurement using calibrated system. And xx nm resolution and yy ${\mu}m$ stroke was attained.

대변위 측정을 위한 다중화된 광섬유 센서 (A multiplexed fiber-optic sensor for measuring large displacement)

  • 유정애;권일범;조재흥;서대철
    • 센서학회지
    • /
    • 제14권3호
    • /
    • pp.169-179
    • /
    • 2005
  • A multiplexed bend loss type single-mode fiber-optic sensor system was prepared to measure the displacement of several cm of the civil engineering structures such as many bridges, tunnels and various buildings. This bend loss type fiber-optic sensor used the signal difference between two reflection signals due to various bend losses generating at a pair of optical connectors by using OTDR (optical time domain reflectometer) for measuring displacements. And the experiments were conducted for showing the measurement feasibility on the range of 10 cm, and the multiplexing experiments were also performed to measure the displacements of 5 measuring positions of an object by setting these 5 fiber-optic sensors on a single mode fiber simultaneously.

Spectral-Domain 광 계측을 위한 CCD 이미지 센서 드라이버 제작 (Realization of CCD Image Sensor Driver for Spectral-Domain Optical Measurement System)

  • 김훈섭;이정렬;엄진섭
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.125-128
    • /
    • 2007
  • This paper presents Spectral-Domain optical measurement system using self-fabricated CCD sensor driver. The light source is a high brightness white LED and the detector is a 2048 array typed CCD image sensor. I have fabricated the CCD sensor driver to generate four pulse signals, which are the CCD-driving pulses. Using this Spectral Domain optical measurement system, the distance value between the reference mirror and the sample mirror can be obtained successfully.

  • PDF

센서용 세라믹 소체의 전기적 수명지수 산출 (Electrical Life Time Constant Estimation of Ceramic Element for Sensor)

  • 정주영;강동식;선종호;허종철;추영배;박정후
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1995-1999
    • /
    • 2009
  • A partial discharge(PD) measurement is a very effective method to assess the insulation condition of high-voltage machines. It is necessary that the life time of the on-line PD measurement sensor is assessed. Therefore, the electrical life time assessment method of ceramic element was reviewed in order to estimate the life time of the on-line PD measurement sensor. The samples were prepared according to the reviewed method and were tested at 8kV, 9kV and 10kV. Based on the obtained results, the life time constant is shown above 59. Also, it is assumed that the estimated life time constant can be used to anticipate the life time and to assess the conformity of the on-line PD measurement sensor.

A Study on Real-Time Slope Monitoring System using 3-axis Acceleration

  • Yoo, So-Wol;Bae, Sang-Hyun
    • 통합자연과학논문집
    • /
    • 제10권4호
    • /
    • pp.232-239
    • /
    • 2017
  • The researcher set up multiple sensor units on the road slope such as national highway and highway where there is a possibility of loss, and using the acceleration sensor built into the sensor unit the researcher will sense whether the inclination of the road slope occur in real time, and Based on the sensed data, the researcher tries to implement a system that detects collapse of road slope and dangerous situation. In the experiment of measuring the error between the actual measurement time and the judgment time of the monitoring system when judging the warning of the sensor and falling rock detection by using the acceleration sensor, the error between measurement time and the judgment time at the sensor warning was 0.34 seconds on average, and an error between measurement time and judgment time at falling rock detection was 0.21 seconds on average. The error is relatively small, the accuracy is high, and thus the change of the slope can be clearly judged.

Development of a measurement device of water level at the bottom of fuel tanks using an optical cable sensor

  • Kim, Hiesik;Lee, Byoungsuk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.95.1-95
    • /
    • 2002
  • <1. New level meter inside the fuel tank> Ultrasound level sensors are widely applied as level meters of liquid tank. Measurement instrument of level between water and fuel is developed. Since the fuel is inflammable, the sensor system doesn't allow to include any electric circuit inside the fuel tank. The optical cable sensor can satisfy this explosive condition. The measurement method with ultrasonic sensor is attached on the tank wall or tank manhole lid. The pressure sensor can't be applied inside the gasoline fuel tank. An ultra-sonic sensor doesn't detect a enough signal reflected from water level deep under gasoline fuel. The pressure sensor is difficult to measure the height o...

  • PDF

클램프 형 직교류 저 전류 측정 센서 (A Clamp Type Sensor for AC/DC Low Current Measurement)

  • 박영태;유광민
    • 한국전기전자재료학회논문지
    • /
    • 제15권12호
    • /
    • pp.1045-1053
    • /
    • 2002
  • This paper describes characteristics of the developed current sensor by means of two identically wound magnetic cores forming a clamp like for measurement of a low DC, or AC current. This sensor consists of peak value detectors, a sensor of an electrically compensated current transformer type, a reference alternating voltage, Precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC, or AC current. The current sensor shows a measurement accuracy of less than 0.3% in the frequency range 40 Hz - 10 HBz. The resolution and sensitivity of the sensor were evaluated 0.1 mA and 10 mV/mA, respectively.

헤마토크릿 영향을 최소화한 종이 혈당센서 개발 (Development of Paper Blood Glucose Sensor with Minimal Hematocrit Effect)

  • 이영태
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.116-120
    • /
    • 2022
  • In this paper, we developed a paper blood glucose sensor that can minimize the effect of hematocrit. The paper blood glucose sensor has the advantage of being very simple in its production process as it is manufactured with only three printing processes on the top of the paper substrate. This glucose sensor consists of a total of six electrodes, including blood glucose measurement electrodes, hematocrit measurement electrodes, strip detection electrodes, and blood detection electrodes. A paper blood glucose sensor measures hematocrit with electrodes formed on the same sensor substrate when measuring blood glucose concentration, and compensates for the effect of hematocrit in real time to enable accurate blood glucose measurement.

재활환자를 위한 IoT 기반의 실시간 모니터링이 가능한 ROM 측정 장치 개발 (Development of ROM Measurement Device capable of IoT-based Real-time Monitoring for Rehabilitation Patients)

  • 강민수
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.111-116
    • /
    • 2018
  • 본 논문에서는 관절 각도계를 사용하여 관절가동범위의 측정하던 것을 각도계를 사용하지 않고 플렉서블 센서를 이용하여 측정하고 측정된 값을 스마트 디바이스와 연동하여 실시간 모니터링이 가능하게 하였다. 현재의 관절가동 범위 측정은 관절 각도기를 활용하여 사람이 직접 측정하고 있다. 이러한 방법은 측정하는 사람의 측정 방법과 위치에 따른 오류로 일관성 있는 측정이 어려워 오차가 발생할 수 있다. 그래서 측정해야 할 관절에 센서를 부착하여 관절의 운동 범위를 측정하였다. 측정을 위한 센서는 플랙서블 형태로 관절의 움직임에 따라 변화되는 저항 값을 측정하는 센서로서 센싱 된 값을 ROM 센서노드를 통하여 무선으로 스마트 디바이스로 전송될 수 있도록 하였다. 개발 된 ROM 측정 장치는 일반적인 관절 각도기를 활용한 측정보다 일관성 있는 측정이 이루어 질 수 있고 스마트 디바이스와 연동하여 실시간 모니터링 함으로써 관절의 움직임에 따른 신속한 진단으로 환자의 빠른 치료와 재활의료 발전에 도움이 될 것이다.