• Title/Summary/Keyword: Measurement principle

Search Result 553, Processing Time 0.027 seconds

Adiabatic Characteristics of Concrete Temperature with Economical Negative Temperature Coefficient Ceramics Sensor System (경제적인 NTC 세라믹스 온도센서 시스템을 이용한 콘크리트 수화열 계측에 관한 실험적 연구)

  • 김기수;김종우;전재홍;하재담;김태홍
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.391-396
    • /
    • 2001
  • In order to estimate thermal cracking in mass concrete and to decide the removal time of the forms outside the concrete structures in wintertime, temperature measurement is indispensible. Until now, the measurement system employs thermocouple type. In this paper, we introduce economical and accurate NTC(Negative Temperature Coefficient) ceramic type measurement system. In principle, NTC ceramic type sensor is very sensitive in the range -20~15$0^{\circ}C$. In this range, the signal change is so large that the sensor needs less amplification than thermocouple. Therefore, not only the sensor itself is inexpensive but also the system is too. In this experiments the temperature of the NTC system are identical to those of thermocouple. In conclusion, inexpensive NTC thermistor system is very adequate to the temperature measurement during concrete curing.

  • PDF

Static measurement of yield stress using a cylindrical penetrometer

  • Uhlherr, P.H.T.;Guo, J.;Fang, T.N.;Tiu, C.
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.1
    • /
    • pp.17-23
    • /
    • 2002
  • A novel and simple method using a cylindrical penetrometer is being developed for the measurement of yield stress. The principle of this technique is based on the measurement of the static equilibrium of a falling penetrometer in a yield stress fluid. The yield stress is simply determined by a balance of forces acting on the penetrometer. The yield stress of Carbopol gels and $TiO_2$ suspensions has been measured using this method. The results are in reasonable agreement with the values from conventional methods. The effects of the dimensions and weight of the penetrometer have been examined. The long-term behaviour was also observed. No measurable creep was seen and equilibrium was found to be very quickly established. The cylindrical penetrometer technique promises to be a simple, quick and reliable static method for the measurement of yield stress.

Case study of a low head & kaplan turbine efficiency measurement using ASFM (절대유량법(ASFM)을 이용한 저낙차.카플란 수차효율측정 적용사례 연구)

  • Lee, Yongjun;Oh, Suegyoung;Shin, Changshik;Hyun, Jungjae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.205.1-205.1
    • /
    • 2011
  • This study concerns a low head and kaplan turbine efficiency measurement using the acoustic scintillation flow meter(ASFM). The ASFM is one of absolute discharge measurement methods because it measures velocity-area of discharge with couples of transducers. This study shows that the highest efficiency of turbine is 87.7% and the efficiency is 85.8% in the rated output(600kW). The test result is reliable because the efficiency trend from this test is similar to the result of index test conducted in 1986. In this paper, the principle, measurement methods, application and test procedures of the test are discussed.

  • PDF

An Experimental Study on the Measurement of Soot Contamination in a Diesel Engine Oil (디젤 엔진오일 내 Soot 함량 증가에 따른 오염도 측정에 관한 실험적 고찰)

  • 공호성;조성용;윤의성;한흥구;정동윤
    • Tribology and Lubricants
    • /
    • v.19 no.5
    • /
    • pp.251-258
    • /
    • 2003
  • New method and device for the on-line measurement of soot concentration in a diesel engine oil are proposed, where the measurement principle is based mainly on attenuated internal total reflection. The detector were evaluated in various ranges of contaminated oils by carbon black particles. It was found that the proposed detector could be well used to monitor the oil deterioration due to soot contamination. Operational range of the detector was found from 0 to 5 mass percentage of soot content. Test results with water and fuel dilution showed that these effects were not remarkable. However, adsorption of carbon black particles onto the measurement surface was considered to be a critical problem of the detector. Effects of particle deposition on the interface was experimentally evaluated with the oil temperature and flow turbulence and discussed throughout this work.

A Study on Spacecraft Alignment Measurement with Theodolite (데오도라이트를 이용한 위성체 얼라인먼트 측정에 관한 연구)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.64-70
    • /
    • 2003
  • A measurement of spacecraft alignment is an important process of spacecraft assembly, integration and test because it is necessary that a ground station controls the precise positions of on-orbit spacecraft by using the alignment data of attitude orbit control sensors(AOCS) on spacecraft. In addition, accuracy of spacecraft alignment requirement is about $0.1^{\circ}$~$0.7^{\circ}$. The spacecraft alignment is measured by autocollimation of theodolite. This paper describes the measurement principle and method of spacecraft alignment. The result shows that all of the AOCS on the spacecraft are aligned within the tolerance required through the alignment measurement.

A Study on Confocal Microscope for A Precise 3-Dimensional Surface Measurement (물체표면의 3차원 정밀형상측정을 위한 공초점 현미경에 관한 연구)

  • 송대호;안중근;강영준;채희창
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.233-236
    • /
    • 1997
  • In modem industry, the accuracy and the surface-finish requirements for machined parts have been becoming ever more stringent. Optical method in measurements is playing an important role in vibration measurement, crack and defect detection and surface topography with the advent of opto-mechatronics. In this study, the principle of the general confocal microscope is introduced for surface measurement, and the advanced confocal microscope that has better measuring speed than the traditional confocal microscope is developed. A study on improving the resolution of the advanced confocal microscope is followed. Finally, Software for data acquisition and analysis of various parameters in surface geometrical features has been developed.

  • PDF

NDIR Multi-Gas Measurement System for Air Quality based on Wireless Sensor Network (무선센서네트워크 기반 공기질 측정을 위한 비분산적외선 복합가스측정시스템)

  • Paik, Seung Hyun;Lee, Jun Yeong;Jung, Sang Woo;Park, Hong Bae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.5
    • /
    • pp.299-304
    • /
    • 2016
  • As public interest in air quality and environment problem is increasing, many researches are being carried out the gas measurement system. Especially, Non-dispersive infrared (NDIR) measurements using Beer-Lambert gas sensing principle with very high selectivity and long life time are noted for reliable method. It is possible to detect various gases such as carbon dioxide (CO2), carbon monoxide (CO), and nitrogen dioxide (NO2), but many researches are mostly concentrated on CO2 sensor. The multi-gas measuring instrument is high price and unwieldy, therefore it is not suitable for wide area required numerous instrument. So we study the NDIR multi-gas measurement system for air quality based on wireless sensor network, and experiment the realized measurement system.

SCRATCH TESTERS ON THE APPLICATION TO THE ADHESION MEASUREMENT OF THIN COATINGS

  • Takeshita, Kyo
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.691-694
    • /
    • 1996
  • Two models of scratch testers developed recently are applied to the adhesion measurement of thin coatings. In both models the critical load is determined from the frictional irregularity when coated surface is broken in the scratching process. One model is effective for coatings thicker than 1m and the other for thin coatings down to $0.1\mu\textrm{m}$. The mechanism and the measurement principle of these testers are described. High sensitivity and good reproducibility of the measurement are attained primarily by the employment of new detection devices. These testers are even more useful for the quality control and the inspection of commercial products of coatings because only a small area of specimen is required for the test.

  • PDF

Compensation On-line of Errors Caused by Rotor Centrifugal Deformation for a Magnetically Suspended Sensitive Gyroscope

  • Xin, Chao-Jun;Cai, Yuan-Wen;Ren, Yuan;Fan, Ya-Hong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.1030-1041
    • /
    • 2018
  • The aim of this paper is to design a centrifugal deformation error compensation method with guaranteed performance that allows angular velocity measurement of the magnetically suspended sensitive gyroscopes (MSSGs). The angular velocity measurement principle and the structure of the MSSG are described, and the analytical model of errors caused by MSSG rotor centrifugal deformation is established. Then, an on-line rotor centrifugal deformation error compensation method based on measurement of rotor spinning speed in real-time has been designed. The common issues caused by centrifugal deformation of spinning rotors can be effectively resolved by the proposed method. Comparative experimental results before and after compensation demonstrate the validity and superiority of the error compensation method.

Multi-function Wattmeter for Voltage, Current, and Power Measurement (정밀전압, 전류, 전력측정 다기능전력계)

  • Park, Yeong-Tae;Yu, Gwon-Sang;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.10
    • /
    • pp.568-572
    • /
    • 2002
  • High precision voltages, currents, and electrical power measurements in wide range of frequency can be achieved by using the thermo-elements(thermal converters). This paper describes a development wattmeter, based on a thermal principle. The instrument has been performed measurement in the range of currents from 0 to 50 A, voltages up to 480 V, power factor 0.5 (lag, lead), 1 and frequencies from 60 Hz to 3 KHz. It is intended to be used by electric utilities, standard laboratories, testing laboratories, and applications where high measurement accuracy are attractive consideration.