• 제목/요약/키워드: Measurement position

검색결과 2,291건 처리시간 0.031초

악관절 방사선 촬영법에 따른 과두위 분석에 관한 비교 연구 (A COMPARATIVE STUDY ON ASSESSMENT OF CONDYLAR POSITION BY THE TMJ RADIOGRAPHY)

  • 이진홍;박창서
    • 치과방사선
    • /
    • 제16권1호
    • /
    • pp.81-91
    • /
    • 1986
  • The author obtained the trans cranial radiographs of right and left side and the individualized lateral tomograms of right and left side after the analysis of submental vertex view from 8 young adults of 25-32 years with normal occlusion. The condylar position from 32 radiographs of normal TMJs were assessed with each measurement methods. All datas from these analyses were recorded and statistically processed with CYBER computer system. The results were obtained as follows. 1. In each measurement methods, the area measurements using the midpoint fossa and the midpoint condyle revealed the hightest concordance rate between the radiographic pairs. 2. In the subjective evaluation, the qualitative concordance existed in 44% and the full concordance existed in 25%, so it was found that concordance rates were relatively low between the radiographic pairs. 3. In each measurement methods, the area measurement using the midpoint fossa revealed the strongest correlation between the radiographic pairs. 4. The correlations between the area measurement using the midpoint fossa and subjective valuation revealed relatively strong value which is 0.926 in the trans cranial radiographic series and the lowest value which is 0.743 in the tomographic series.

  • PDF

굴삭기의 정적/동적 응력 및 구동 특성 계측 (Measurement of Static and Dynamic Stress and Motion Characteristics of Excavators)

  • 김규성;정준모;장영식;최익흥;이준희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.473-478
    • /
    • 2003
  • This paper presents static and dynamic measurement of the stress and motion characteristics for crawler type excavators. Eight scenarios were prepared for static measurement based on two extreme digging positions, maximum digging reach position and maximum digging force position. The measured items for static motion included stress, cylinder pressure, cylinder stroke and digging force. The measured static stresses showed that asymmetric digging force acting on a bucket induced higher stress level than symmetric one. The measured static pressures and digging forces also agreed with design pressures and design digging forces, respectively. The dynamic measurement was performed for two types of motion, that is, simple reciprocation of each cylinder and actual digging motion. The measured items for dynamic motion were stroke and pressure of each cylinder, stresses on the working device and acceleration on the upper plate of an arm. The measured data showed that the natural frequency of the excavator highly depended on the hydraulic stiffness of cylinders. Digging motion tests revealed that digging motion was closer to static motion rather than dynamic one.

  • PDF

머리전달함수 측정시스템의 개발과 분석 (Newly Designed HRTF Measurement System and its Analysis)

  • 이윤재;박영진;박윤식
    • 제어로봇시스템학회논문지
    • /
    • 제16권2호
    • /
    • pp.202-205
    • /
    • 2010
  • When we render 3D sound images using headphones or speakers, the main key of this technology is the Head-related transfer function (HRTF) database. Even though there are various HRTF databases, they have some drawbacks such as detrimental effects caused by imperfect measuring environment and insufficient measurement points. Moreover there is no database with Korean subjects. We are planning to develop the HRTF database for Korean. As a first step to establish the HRTF database aimed at Korean, the new HRTF measurement system with minimized aforementioned drawbacks is designed. In this paper, the newly designed HRTF measurement system is introduced and the overall effects caused by the diffraction of the apparatus, especially the headrest and backrest of the chair, are analyzed. The backrest of the chair does not distort the HRTFs significantly while the headrest makes significant distortion on the HRTFs and it could have significant effects on directional perception. We determined acceptable head rotation angle and head position of the subject for accurate HRTF measurement based on the experiments with B&K HATS. We conclude that the 3 degrees of the head rotation and the 1.5cm front/back/left/right shift of the head do not distort the HRTFs significantly.

영상 크기 변환에서 화소들의 생략 및 추정 위치를 고려한 객관적 영상 화질 측정 (An Objective Image Quality Measurement Considering Skipped & Estimated Positions of Pixels in Image Scaling)

  • 김원희;문광석;김종남
    • 한국멀티미디어학회논문지
    • /
    • 제16권8호
    • /
    • pp.934-942
    • /
    • 2013
  • 영상 크기 변환은 응용 환경에서의 다양한 목적을 위하여 사용되며, 변환 함수의 성능을 평가하기 위하여 처리전과 후의 두 영상의 화질을 비교한다. 변환 함수의 객관적 성능 평가를 위하여 화질 비교의 정확한 지표가 요구되며, 실제 다양한 관점에서의 접근이 이루어졌다. 하지만 영상 크기 변환 과정에서 생략되거나 새롭게 생성되는 화소들의 위치를 고려한 화질 비교 척도에 관한 연구는 거의 이루어지지 않고 있다. 따라서 본 논문에서는 영상 크기 변환에서 발생하는 화소들의 생략 및 추정 위치를 고려한 객관적 영상 화질 측정방법을 제안한다. 제안하는 방법은 기존의 영상 화질 척도를 이용하여 위치 변화를 고려한 새로운 영상화질 측정 방법을 만들고, 위치 변화에 대한 민감도를 평가하였다. 실험을 통해서 기존에 널리 사용되는 영상 화질 측정 방법이 화소들의 생략 및 추정 위치의 변화에 많은 영향을 받는 것을 알 수 있었고, 제안하는 방법이 화소들의 생략 및 추정 위치 변화를 고려한 영상 화질 표현의 객관적 척도임을 확인하였다. 제안하는 방법은 영상 복원 및 개선 함수의 성능을 평가하는 척도로서 유용하게 사용될 수 있다.

영상처리기법과 2축 스테이지를 이용한 미세부품의 추적 시스템 개발 (Development of Tracking System for Micro Mechanical Part Using Image Processing Technique and 2-Axis Stage)

  • 표창률;강성훈;전병희
    • 소성∙가공
    • /
    • 제13권3호
    • /
    • pp.273-278
    • /
    • 2004
  • This paper subscribes the measurement system that can position the target to measure by moving 2-axis stage, which is controlled by the data from image processing technique. The high resolution camera and lens are used in measurement of micro mechanical part, but the region of measurement is very small. It is necessary the re-positioning to measure several regions in one part. The system described in this paper has the accuracy with about $0.9\mu\textrm{m}$ resolution per one pixel and can be applied to measure micro mechanical part.

위치/힘 동시제어를 위한 F/T측정 기능을 갖는 6축 순응기구 설계 (Design of a 6-axis Compliance Device with F/T Sensing for Position/Force Control)

  • 김한성
    • 한국산업융합학회 논문집
    • /
    • 제21권2호
    • /
    • pp.63-70
    • /
    • 2018
  • In this paper, the design of a novel 6-axis compliance device with force/torque sensing capability and the experiment results on force measurement are presented. Unlike the traditional control methods using a force/torque sensor with very limited compliance, the force control method employs a compliant device to provide sufficient compliance between an industrial robot and a rigid environment for more stable force control. The proposed compliance device is designed to have a diagonal stiffness matrix at the tip and uses strain gauge measurement which is robust to dust and oil. The measurement circuit is designed with low-cost IC chips however the force resolution is 0.04N.

도플러방식과 헤테로다인 방식의 광간섭법을 병용한 절대높이 측정 정밀도 향상 (Improvement of Measurement Accuracy for Absolute Height by Using Two Types of Doppler and Heterodyne Optical Interferometry)

  • 안근식;장경영;문희관
    • 한국정밀공학회지
    • /
    • 제13권6호
    • /
    • pp.128-135
    • /
    • 1996
  • This paper proposes a high precision measurement technique to obtain the height of gage block with a few millimeter height. The proposed technique is consisted of two steps : In the first step, laser position transducer and electric micrometer are adopted to obtain a coarse value of the height of gage block, and then, in the second step, heterodyne laser interferometry is adopted to acquire the precision value. A new kind of phase detector is constructed in the low cost for the heterodyne interferometer and its linearity with ${\pm}1%$ is confirmed by experiment. Also measurement error factors due to enviroments are discussed and methodology to reduce such errors is proposed. Preliminary experiments are carried out for the gage blocks of as high as a few millimeter.

  • PDF

전자빔 가공 포커스 위치 보정용 측정기구에 관한 기초연구 (Study of measurement system for E-beam focus position compensation)

  • 하태호;송은지;이창우;송준엽
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.273-274
    • /
    • 2006
  • Fundamental research is conducted in order to develop measurement system for E-beam focus position compensation. In this paper, simulation results using Fresnel's formula shows effect of photoresist film thickness according to incident conditions. Also, electromagnetic simulator is developed based on Boundary Element method (BEM) and several results confirm the feasibility of the simulator.

  • PDF

Machine Vision을 이용한 기둥형 물체의 3차원 측정 (3-Dimensional Measurement of the Prismatic Polyhedral Object using Machine Vision.)

  • 조철규;이석희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.733-737
    • /
    • 1996
  • This paper presents a method to measure tile position and orientation of a prismatic polyhedral object (of unknown width, length, height, and number of vertices) using machine vision. The width, length, and origin of workplace where an object is lying are defined as Preliminary operation. The edges of an object are detected from captured image using least sum of square error. The information of an object is determined from the geometric relationships between edges. As an user interface, a versatile image processing program is developed in several modules, and renders a very useful 3D measurement at a limited constraints when adopted in automation of production process. The flexibility of camera position from the algorithm developrf can be used for automated pick and place operations and feeding workpiece u: ;ing assembly robot.

  • PDF

골밀도 측정의 올바른 임상 적용 (Clinical Application of Bone Mineral Density Measurement)

  • 김덕윤
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.275-281
    • /
    • 2004
  • Compared with the earlier technique of dual photon absorptiometry (DPA) using $^{153}Gd$ radionuclide source, dual energy X-ray absorptiometry (DXA) has advantages of higher precision, accuracy and shorter scanning time. Despite the change from DPA to DPX, the nuclear medicine physicians has remained one of major suplier of this service due to long-standing use of DPA. Among many kinds of bone densitometries, DXA is the "gold standard" for the noninvasive diagnosis of osteoporosis. Especially there is no role for peripheral devices in the monitoring of patients on therapy. But, there are some areas of controversy related to the application of DXA, such as proper site of measurement, accurate interpritation, appropriate use of T-score, and the reference population young database. And the accuracy, precision, and quality control issues relating to bone density measurement are important subjects. To address these issues, the International Society for Clinical Densitometry (ISCD) has convened two Position Development Conferences and addressed official positions. This review deals the key elements of ISCD position paper and other important issues on the management of bone densitometry.