• 제목/요약/키워드: Measurement point

검색결과 3,258건 처리시간 0.038초

사용자환경의 메타포가 스마트폰 애플리케이션 사용의도에 미치는 영향 (The Effects of Metaphors in the Interface of Smartphone Applications on Users' Intention to Use)

  • 정원진;홍석기
    • Asia pacific journal of information systems
    • /
    • 제24권3호
    • /
    • pp.255-279
    • /
    • 2014
  • It is not too much to say that smartphones have become an essential part of our lives due to their versatility. Nevertheless, they still have less overall capabilities than their desktop counterparts. Specifically, they have small screens and low resolutions, which make their applications difficult to have a usable interface. To account for these limitations, the interface of smartphone applications should be designed carefully and properly. Good interface design to any application is critical. However, a comprehensive information systems (IS) literature review found that there has been little research on the user interface design of smartphone applications. More specifically, there has been little empirical evidence and understanding about how metaphors, an imaginative way of describing objects and concepts, in the user interface of smartphone applications affect users' intention to use the applications. Thereby, the research goals of this study are to examine 1) the effects of the metaphors in the user interface of smartphone applications on the interaction between users and applications and 2) the effects of mediating variables including the interaction between users and applications, users' beliefs and attitudes, on users' intention to use the applications. A survey was conducted to collect data. University students and practitioners participated in the survey. A 24-item questionnaire was developed on a 5-point Likert-type scale. The measurement items were mostly adapted from the previous studies in the IS literature and modified to fit the context of this study. First, a principal component factor analysis was performed to explore the inter-relationships among a set of variables. The analysis showed that most of the items loaded quite strongly on the six components. The analysis also revealed the six components with eigenvalues exceeding 1, explaining a total of 70.7 per cent of the variance. The reliabilities of the items were also checked. Most Cronbach alpha values were above 0.8, so the scales were considered reliable. In sum, the results of the analysis support the decision to retain the six factors for further investigation. Next, the structural model was analyzed with AMOS structural equation modeling. The values of GFI, AGFI, NFI, TLI, CFI, and RMSEA were checked. The values showed that the research model considerably have a good fit in general. Next, the convergent and discriminant validities of all constructs were examined. The values for the standardized regression weights and critical ration (CR) indicated sufficient convergent validity for all constructs. In addition, the square root of the average variance extracted (AVE) of each construct was compared with its correlations with all other constructs. The results supported discriminant validity for all constructs. In sum, the results of analysis demonstrated adequate convergent and discriminant validities for all constructs. Finally, path coefficients between the variables were examined. Methphor was found to have an impact on interaction (${\beta}$ = .457, p = .000). There were also significant effects of the interaction on perceived usefulness (${\beta}$ = .273, p = .000) and ease of use (${\beta}$ = .405, p = .000). User attitude was significantly influenced by these two beliefs, perceived usefulness (${\beta}$ = .386, p = .000) and ease of use (${\beta}$ = .347, p = .000) respectively. Further, the results of analysis found that users' intention to use smartphone applications was significantly influenced by user attitude (${\beta}$ = .567, p = .000). Based upon the analyses, all hypotheses were supported. This study found that the metaphors used in the interface of smartphone applications affect not only the interaction between users and applications, but also users' intention to use the applications through the mediating variables, perceived usefulness and ease of use. These findings imply that if the metaphors used in the user interface of application are easy enough to understand for smartphone users, then the application can be perceived useful and easy to use, which in turn make users to have an intention to use the application. In conclusion, this study contributed not only to validate and extend Technology Acceptance Model (TAM) partially, but also to develop the construct of metaphor in smartphone settings. However, since a single empirical study cannot be enough to validate the findings, some limitations should be considered.

MCF-7 세포에서 spermine에 의한 부착단백질 Integrin β1과 FAK, 세포골격 단백질 actin의 조절 (Modulation of Adhesion Proteins Integrin β1 and FAK, and Cytoskeletal Protein Actin by Spermine in MCF-7 Cells)

  • 지혜진;김병기
    • 생명과학회지
    • /
    • 제22권1호
    • /
    • pp.16-24
    • /
    • 2012
  • Polyamine은 모든 세포의 성장과 분화에 필수적인 요소지만 그 기작은 아직 정확하게 밝혀져 있지 않다. 본 논문에서는 MCF-7세포에서 spm의 세포독성 기작을 연구하였다. MTT assay 결과 저농도의 spm (<10 ${\mu}M$) 처리시 cell viability가 증가하는 반면 고농도의 spm 처리시 처리 시간과 처리 농도에 의존적으로 감소되었으며, 이는 고농도의 spm이 MCF-7 cell에 cytotoxic한 효과를 가지고 있는 것으로 사료된다. Cell cycle 분석 결과 spm 농도에 의존적으로 sub-G1 단계의 세포 양이 증가하는 것으로 나타났으며, 이는 spm이 세포분열을 억제함으로써 세포사를 유발하는 것으로 생각된다. 또한 고농도의 spm 처리 후 2시간이 지나자 cell 표면이 움츠려 들며 rounding되기 시작하여 하루가 지난 후 거의 모든 cell이 culture dish 에서 떨어진 것을 관찰할 수 있었다. 이는 spm이 세포부착에 관여하여 세포사를 유발하는 것이라 생각되며, 세포부착을 조절하는 Integrin ${\beta}1$은 저농도의 spm에선 별다른 차이를 보이지 않다가 농도가 높아질수록 조금씩 감소하였으며, cytoskeletal protein인 actin은 농도의존적으로 감소하였다. 반면 adhesion protein인 FAK는 저농도의 spm 처리시에도 급격히 감소하였다. 이는 spm이 adhesion 및 cytoskeletal proteins의 발현을 억제하는 것으로 보이며, 특히 Integrin ${\beta}1$과 actin에 비해 FAK에 더 많은 영향을 끼치는 것으로 사료된다. 단백질들의 세포막상의 분포에 관한 연구에서, membrane 상에 위치하던 Integrin ${\beta}1$은 10 ${\mu}M$의 spm 처리시 세포 내로 약간의 위치변동이 일어났으나 그 양에는 크게 차이가 없었으며, 반면에 actin은 위치상엔 큰 변화가 일어나지는 않았지만 농도에 따라 크게 감소하는 것으로 나타났다. 세포이동과 형태조절에서 중추적인 역할을 하는 FAK는 세포막 안쪽에 위치하고 있다가 spm 처리시 세포 가운데로 이동하는 모습이 관찰되었으며 그 양도 크게 감소하였다. 이상의 실험에서 세포 내 spm의 변화는 MCF-7 cell의 adhesion protein인 Integrin ${\beta}1$과 FAK, 그리고 cytoskeletal protein인 actin의 발현을 조절하여 cell attachment를 억제함으로써 세포분열과 생장을 억제하는 것으로 분석된다.

높은 LO-RF 격리 특성의 W-band MIMIC Single-balanced 믹서 (High LO-RF Isolation W-band MIMIC Single-balanced Mixer)

  • 안단;이복형;임병옥;이문교;이상진;진진만;고두현;김성찬;신동훈;박형무;박현창;김삼동;이진구
    • 대한전자공학회논문지TC
    • /
    • 제42권6호
    • /
    • pp.67-74
    • /
    • 2005
  • 본 논문에서는 branch line coupler과 $\lambda$/4 전송라인을 이용하여 W-band MIMIC(Millimeter-wave Monolithic Integrated Circuit) single-balanced 믹서를 설계 및 제작하였다. Single-balanced 믹서의 설계를 위해 branch line coupler와 $\lambda$/4 전송라인 이용한 94 GHz 발룬 회로를 설계하였으며, 시뮬레이션 결과 94 GHz에서 반사계수는 -27.9 dB를 얻었으며, coupling은 4.26 dB, thru 특성은 -3.77 dB의 결과를 얻었다. 격리도와 위상차는 94 GHz에서 각각 23.5 dB 및 $180.2^{\circ}$의 결과를 얻었다. MIMIC single-balanced 믹서는 0.1 $\mu$m InGaAs/InAlAs/GaAs Metamorphic HEMT (High Electron Mobility Transistor) 다이 오드를 이용하여 설계 및 제작되었다. 제작된 MHEMT는 fT는 189 GHz, fmax는 334 GHz의 양호한 성능을 나타내었다. 설계된 믹서는 본 연구에서 개발된 MHEMT MIMIC 공정을 이용해 제작되었다. 94 GHz MIMIC single-balanced 믹서의 측정결과 변환손실 특성은 94 GHz에서 23.1 dB의 특성을 나타내었으며, 입력 Pl dB는 10 dBm, 출력 Pl dB는 -13.9 dBm의 결과를 얻었다. Single-balanced 믹서의 LO-RF 격리도는 94.19 GHz에서 45.5 dB의 높은 LO-RF 격리도 특성을 나타내었다. 본 논문에서 설계 및 제작된 W-band MIMIC Single-balanced 믹서는 기존의 밀리미터파 대역 믹서와 비교하여 높은 LO-RF 격리도 특성을 나타내었다.

5령유충의 배맥관운동에 대한 양이온의 영향에 관한 연구 (Studies on the Effect of Cation on the Activity at the 5th Instar Larvae of Bombyx mori)

  • 윤종관;사기언
    • 한국잠사곤충학회지
    • /
    • 제18권2호
    • /
    • pp.89-93
    • /
    • 1976
  • 동물에 대한 생리적 염류용액은 소위 링가씨액으로서 냉혈척추동물의 신경근육 심장등을 비교적 정상에 가까운 상태로 지속시키기 위한 용액으로 개구리 (Frog)의 심장의 관수실험을 하기 위하여 처방한 최초의 생리적 염류용액에 지나지 않았지만 현실에 있어서는 몇몇 동물은 물론 사람에 이르기까지 거의 완전한 생리적 용액으로 되어 있는데 가잠에 있어서는 몇가지 처방이 발표된 바는 있어도 아직 그 결과가 만족할 만한 정도에까지는 이르지 못하고 있다. 일반적으로 생리적 염류용액은 전술한 바와 같이 적출한 기관과 조직에 대하여 장시간에 걸친 정상적 기능을 유지시키기 위한 용액으로 사용되는 염류의 혼합용액이기 때문에 적당한 Ion조성 삼투압 PH를 갖도록 조제된다. 대개 생기내에서 이들의 기관과 조직을 적시는 혈청등 체액성분에 근사한 것을 사용한다. 용액의 Ion성분은 $Na^{+}$을 비롯하여 $K^{+}$, $Ca^{++}$, $Mg^{++}$ 등을 가하고 여기에 NaHCO$_3$, NaH$_2$PO$_4$등의 연형제를 첨가하므로서 PH를 조절한다. 생리적 염류용액중에 포함하여야 할 Cation의 최적농도 2종 이상의 Cation의 최적혼합비율등에 대하여 가잠유충의 배맥관 운동을 지표로 하여 이를 검토하였다. 각 Cation의 최적농도는 영점미만의 NaCl의 함유액을 기본으로 하고 여기에 각각 농도를 달리한 KCl, CaCl$_2$및 MgCl$_2$등을 조합하여 이들의 액체를 적하하므로서 5령유충의 배맥관 운동의 지속시간과 맥박수를 지표로 하여 이들 시험액의 효과를 검토한 바에 의하면 NaCl 단독일 경우에는 해부후 일시적으로 맥박수는 증가하지만 점차 정지되고 만다(일시간정도). 여기에 대하여 KCI를 가하면 일반적으로 박동시간이 연장되고 맥박수의 저하도 늦어지는 경향을 나타내고 있으며 여기에 다시 KCl와 CaCl$_2$를 가하면 그 지속시간은 더 한층 연장되었다. KCI와 CaC1$_2$의 가용은 효과가 있지만 이들의 농도와 배맥관의 활동에 있어서는 일정한 경향이 인정되지 않았고 $Ca^{++}$ 또는 $K^{+}$의 박동에 대한 작용은 이것을 분명히 할 수 없었고 $Mg^{++}$의 작용에 있어서는 배맥관에 이를 가하면 박동 지속시간에는 영향을 끼치지 않지만 맥박수는 크게 저하됨을 인정할 수 있었다.

  • PDF

청소년 약물사용 잠재군 선별척도(SPDA) 활용을 위한 타당화 연구 (A Validation Study for the Practical Use of Screening Scale for Potential Drug-use Adolescents(SPDA))

  • 이기영;김영미;임혁;박미진;박선희
    • 한국사회복지학
    • /
    • 제57권3호
    • /
    • pp.305-335
    • /
    • 2005
  • 이 논문은 2003년에 개발된 SPDA(A Screening Scale For Potential Drug-use Adolescents)의 타당성검증을 위한 2차년도 연구결과이다. SPDA는 청소년들의 약물사용에 대한 조기 예방적 개입을 위한 선별도구로서 활동을 그 목적으로 한다. 연구를 위한 조사대상자는 전국에 재학중인 중 고등학생(n=4,307)으로서 층화표집과 할당표집으로 선발되어 SPDA와 관련척도에 대하여 응답하였으며, 비교집단으로 전국 보호관찰청소년(n=305)들도 동일한 조사에 참여케 하였다. 타당화의 주요한 내용은 신뢰도, 내용타당도, 구성타당도, 기준관련타당도, 동시타당도 등을 검증하는 것이었다. 연구 결과, 척도의 신뢰도는 Cronbach 알파계수 0.914를 나타냈다. 구성타당성을 위한 탐색적 요인분석 결과 SPDA는 개인특성, 문제행동, 부모의 문제와 약물경험, 부모와의 관계, 음주환경과 태도, 약물사용환경과 태도 등 7가지 요인으로 나뉘었고, 확인적 요인분석결과는 모형적합도 지수, 요인부하량을 검토할 때 SPDA의 각 요인구조가 적합도가 높은 측정모델로 입증되었다. 그리고 기준관련 타당도를 검증하기 위한 판별분석에서는 본 척도의 분류 적중률이 86.6%(중학생 78.8%, 고등학생 87.4%)로 나타나 적절한 예측타당도를 가지고 있음을 확인할 수 있었다. 동시타당도에서는 "Hare Home Self-Esteem Scale", "Hare School Self-Esteem", "Zuckerman-Kuhlman Sensation-seeking scale" 세 척도와 모든 영역의 상관계수가 유의미한 값을 보여주었다. 또한 SPDA 총 약물사용에 대한 잠재군과 비잠재군(일반중고생)에 대해 유의미한 변별력을 가지고 있었다. 실제적 활용을 위해 잠재군을 분류할 수 있는 절단점으로 T-점수(+0.5SD)를 이용하였으며 잠재 약물사용군으로 분류될 수 있는 대상은 총 점수 77점 이상일 경우였다.

  • PDF

지역사회 말기질환자 가족 부담감에 관한 연구 (A Study of Family Caregiver's Burden for the Terminally III Patients)

  • 한성숙;노유자;양수;유양숙;김석일;황희경
    • 가정∙방문간호학회지
    • /
    • 제10권1호
    • /
    • pp.58-72
    • /
    • 2003
  • The purpose of this study was to describe the perceived burden of the terminally III patients's caregiver and to analyze relationship between the perceived burden and the various demographics, illness characteristics, family relationships, and economic factor of the family & patients. The sample of 132 caregivers who care for the terminally III patients Kyung-Gi province, Seoul, Korea. The period of this study was from August to September, 2002. The perceived burden of the family caregiver was measured by the burden scale(20 items, 4 point scale) developed by Montgomery et al. (1985). The Data was analyzed using SAS-program by t-test and ANOVA. The results were as follows; 1. The mean of the family caregiver's burden score was 3.02. The score showed that caregivers perceive severe the level of burden. The hight items of the family caregiver's burden were' I feel it is painful to watch patient's diseases'(3.77). 'I feel afraid for what the future holds for my patients'(3.66), 'I feel it reduced to amount of privacy time'(3.64). 2. The caregiver's burden was significantly related to patient's gender(F=3.17, p= 0.0020), patient's job(F=2.49, p=0.0476), caregiver's age(F=4.29, p=0.0030), and caregiver's job(F=2.49, p=0.0476). 3. The caregiver's burden according to illness characteristics showed no significant difference. 4. The caregiver's burden was significantly associated with patient's family relationship (F=4.05, p=0.0041), patient's care mean period in a day(F=47.18,

  • PDF

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

껌씹기가 저작근의 경도와 탄성도에 미치는 효과 (Muscle Stiffness and Elasticity of Masticatory Muscles on Gum Chewing)

  • 원태희;김미은;김기석
    • Journal of Oral Medicine and Pain
    • /
    • 제32권4호
    • /
    • pp.421-429
    • /
    • 2007
  • 최근 tactile sensor 를 사용하여 근육의 경도와 탄성도를 조사하는 방법이 저작근의 새로운 평가방법으로 제시되고 있다. 본 연구의 목적은 촉각센서를 이용하여 일정시간 껌씹기를 시행전, 중, 후의 저작근의 경도와 탄성도를 조사하여 향후 턱관절 장애 환자의 저작근 평가를 위한 기초자료를 확보하는 데 있다. 건강한 성인 8명을 대상으로 양측 전측두근(anterior temporalis), 하교근(inferior masseter)의 경도와 탄성도를 촉각센서 (Venustron II, Axion Co., Japan)를 이용하여 다음과 같이 측정하였다. 피검자들을 unit-chair에 바로 앉힌 상태에서 양측 교근 및 측두근 부위를 촉진을 통해 전 측두근(temporalis anterior), 하 교근(masseter inferior) 두 부위를 펜으로 표시하였다. 실험의 재현성을 위하여 투명한 종이에 ala-tragus line을 표시한 후 두 부위를 투명종이 위에 표시하였다. 편안한 상태에서 촉각센서를 사용하여 양측 하 교근 및 전 측두근의 경도와 탄성도를 측정한 후, 껌(Excellent Breath, Taiyo Co., Japan)을 양측으로 씹게 하여 1초당 2회의 속도로 씹게 하였다. 껌을 40분동안 저작하는 동안 10분, 20분, 30분, 40분에 양측 하 교근 및 전 측두근의 경도와 탄성도를 측정하였다. 그 후 껌을 뱉게 하고 하악의 안정위 상태에서 10분, 20분, 30분, 40분 후 양측하 교근 및 전 측두근의 경도와 탄성도를 각각 측정하였다. 측정치들을 반복측정 이원분산분석과 다중비교를 통하여 비교하였다. 실험결과 측두근과 교근을 비교 시 탄성도, 경도 모두 교근의 변화가 유의하게 크다. 또한 저작하면 서서히 경도는 증가하며 탄성도는 반대로 감소한다. 탄성도 및 경도는 저작 시 신속히 증가하나 저작 종료 후에는 탄성도만 신속히 회복되나 경도는 약 10분 이상의 일정시간이 지나야 회복된다. 이상의 결과들을 보아 임상적으로 좀 더 다양한 연구와 기초자료가 확보된다면, 저작근의 근육 상태를 평가하는데, 근육의 탄성도와 경도를 조사하는 tactile sensor system은 유익한 기기로서 활용될 수 있을 것이다.

구면조화해석(球面調和解析)에 의(依)한 한반도내(韓半島內)의 지구자기장(地球磁氣場)의 분포(分布)에 관(關)한 연구(硏究) (Geomagnetic Field Distribution in the Korean Peninsula by Spherical Harmonic Analysis)

  • 민경덕;이선희
    • 자원환경지질
    • /
    • 제12권2호
    • /
    • pp.95-104
    • /
    • 1979
  • The position of any point on the earth's surface can be. represented in the spherical coordinates by surface spherical harmonics. Since geomagnetic field is a function of position on the earth, it can be also expressed by spherical harmonic analysis as spherical harmonics of trigonometric series of $a_m({\theta})$ cos $m{\phi}$ and $b_m({\theta})$ sin $m{\phi}$. Coefficients of surface spherical harmonics, $a_m({\theta})$ and $b_m({\theta})$, can be drawn from the components of the geomagnetic field, declination and inclination, and vice versa. In this paper, components of geomagnetic field, declination and inclination in the Korean peninsula are obtained by spherical harmonic analysis using the Gauss coefficients calculated from the world-wide magnetic charts of 1960. These components correspond to the values of normal geomagnetic field having no disturbances of subsurface mass, structure, and so on. The vertical and total components offer the zero level for the interpretation of geomagnetic data obtained by magnetic measurement in the Korean peninsula. Using this zero level, magnetic anomaly map is obtained from the data of airborne magnetic. prospecting carried out during 1958 to 1960. The conclusions of this study are as follows; (1) The intensity of horizontal component of normal geomagnetic field in Korean peninsula ranges from $2{\times}10^4$ gammas to $2.45{\times}10^4$ gammas. It decreases about 500 with the increment of $1^{\circ}$ in latitude. Along the same. latitude, it increases 250 gammas with the increment of $1^{\circ}$ in longitude. (2) Intensity of vertical component ranges from $3.85{\times}10^4$ gammas to $5.15{\times}10^4$ gammas. It increases. about 1000 gammas with the increment of $1^{\circ}$ in latitude. Along the same latitude, it decreases. 150~240 gammas with the increment of $1^{\circ}$ in longitude. Decreasing rate is considerably larger in higher latitude than in lower latitude. (3) Total intensity ranges from $4.55{\times}10^4$ gammas to $5.15{\times}10^4$ gammas. It increases 600~700 gammas with the increament of $1^{\circ}$ in latitude. Along the same latitude, it decreases 10~90 gammas. with the increment of $1^{\circ}$ in longitude. Decreasing rate is considerably larger in higher latitude as the case of vertical component. (4) The declination ranges from $-3.8^{\circ}$ to $-11.5^{\circ}$. It increases $0.6^{\circ}$ with the increment of $1^{\circ}$ in latitude. Along the same latutude, it increases $0.6^{\circ}$ with the increment of l O in longitude. Unlike the cases of vertical and total component, the rate of change is considerably larger in lower latitude than in higher latitude. (5) The inclination ranges from $57.8^{\circ}$ to $66.8^{\circ}$. It increases about $1^{\circ}$ with 'the increment of $1^{\circ}$ in latitude Along the same latitude, it dereases $0.4^{\circ}$ with the increment of $1^{\circ}$ in longitude. (6) The Boundaries of 5 anomaly zones classified on the basis of the trend and shape of anomaly curves correspond to the geologic boundaries. (7) The trend of anomaly curves in each anomaly zone is closely related to the geologic structure developed in the corresponding zone. That is, it relates to the fault in the 3rd zone, the intrusion. of granite in the 1st and 5th zones, and mountains in the 2nd and 4th zones.

  • PDF

배양세포에서 Semi-quantitative RT-PCR에 의한 조류인플루엔자 H9N2의 전사활성 분석 최적 시기 결정 및 전사체 분석 (Deterimination of an Optimal Time Point for Analyzing Transcriptional Activity and Analysis of Transcripts of Avian Influenza Virus H9N2 in Cultured Cell)

  • 나기윤;이영민;변승준;전익수;박종현;조인수;주이석;이윤정;권준헌;구용범
    • 미생물학회지
    • /
    • 제45권3호
    • /
    • pp.286-290
    • /
    • 2009
  • 조류인플루엔자 바이러스 mRNA의 전사는 감염 동안에 시간적으로 조절되어진다. 감염 후 세포 내에서 증식된 바이러스가 방출되어 세포를 다시 감염하게 되면 전사 수준 분석에 오차가 발생할 수 있으므로 바이러스가 방출 되기 이전에 전사 수준의 측정이 이루어져야 한다. 본 연구에서는 조류인플루엔자 H9N2를 감염시킨 닭의 섬유아세포주 UMNSAH/DF-1에서 바이러스 감염 후 증식된 바이러스의 방출까지의 시간을 측정하기 위하여 배양액 중에 방출되는 바이러스 RNA 게놈 수준을 semi-quantitative RT-PCR에 의해 측정하였다. 배양액 중의 바이러스 RNA 게놈의 분리 과정에서 발생할 수 있는 RNA 회수율의 오차를 보정하기 위해 mouse의 전체 RNA를 배양액 시료에 넣어서 바이러스 RNA 분리에 carrier로 사용하고 그 속에 포함된 mouse의 GAPDH를 RNA를 역전사 반응 및 PCR의 내부 대조 RNA로 사용하였다. 그 결과 감염 후 방출까지 16~20시간이 소요됨을 알 수 있었다. 따라서 감염 후 12시간 후에 세포 내에서 합성된 8종의 전사체의 수준을 측정하였다. 8종의 mRNA 중 PA를 제외한 7종의 mRNA (HA, NA, PB1, PB2, NP, M, NS를 암호화하는 mRNA)는 뚜렷한 증폭 band를 보였으며, 이것은 이들이 전사활성 측정에 사용될 수 있는 것으로 나타났다. 이상과 같은 전사수준의 측정 방법은 조류인플루엔자 바이러스의 RNA polymerase를 표적으로 한 항바이러스제의 검색에 사용할 수 있을 것으로 보인다.